Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC NO 111 BHARATH NAGAR M S PALYA VIDYARANYAPURA VIDYARANYAPURA BANGALORE KARNATAKA 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC deduct credit | |
| 2 | L2₹49.4 L+₹1.5 L (3.17%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹49.8 L+₹1.9 L (3.98%)Rejected-Finance | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹49.8 L+₹1.9 L (3.99%)Rejected-Finance | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹49.9 L+₹2.0 L (4.17%)Rejected-Finance | L5 | Rejected-Finance rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
7 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D East Bangalore
GE RD East Bangalore 93
ADDITION ALTERATION TO BLDG NOS P 13 AND MES22 AT DFRL MYSORE ROOM NO 04 AT GROUND FLOOR OF PFG BUILDING GTRE AND PROVISION MS STAIR FOR EMERGENCY FIRE EXIT IN CAD FACILITY IN STRUCTURE I AND MAV BLDG AT ADE UNDER GE I RD EAST BANGALORE
2020_MES_387356_1
8980
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D East Bangalore
D a (i) b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹88,000
Yes
22 Dec 2020
17 Oct 2020
12 Nov 2020
17 Oct 2020
7 Nov 2020
1 Nov 2020
18 Oct 2020 - 30 Oct 2020
60 days
Amount
Taking down cement or cement lime plaster of any description from walls, including racking out joints hacking for key scrubbing down with water etc , complete all as specified.
Demolition of cement concrete in ground floor and pavings n.exc 15 cm thickness (below or above ground level).
M&L PCC 1:2:4, type B-1(using 20 mm graded stone aggregate) 40 mm thick as in flooring complete all as directed
Material and labour complete removal of existing treatment on walls and applying two coats of plastic emulsion paint over a coat of primer including preparation complete all as specified and as directed
Material and labour for applying two coats of plastic emulsion paint over a coat of primer on newly plastered wall surfaces including preparation complete all as specified and as directed
M&L for applying Exterior wall putty as per manufactures instruction and applying two coats of exterior emulsion paint (weather proof) over a coat of primer including removal of existing treatment on wall/ceiling surfaces including cornices, plasters etc by scrapping down with wire brushes and washing down and removing existing loose finishes particles etc all as specified and directed. Make/Brand Name : Asian Paints/Apex ultima, Berger Paints/Weather coat All Guard, Jenson /Nicholson/Safe Guard
Material and labour complete removal oe existing wall surfaces and applying two coats of oil emulsion distemper over a coat of primer over 3mm thick wall care putty complete all as specified and as directed
M&L applying one coat of synthetic enamel paint on old steel surfaces including necessary preparation complete all as specified and as directed
M&L applying one coat of synthetic enamel paint on old wooden surfaces including necessary preparation complete all as specified and as directed
Material and labour for brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement 1:6 complete all as specified and as directed.
M&L rendering 15mm thick on stone masonry surfaces or surfaces other than fair face of brickwork or on one side of lathing complete all as specified and as directed.
Material and labour for hardcore of guage exceeding 63mm but not exceeding 100 mm, broken stone or boulders deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed.
M&L PCC 1:2:4, type B-1(using 20 mm graded stone aggregate) 100 mm thick as in ramp complete all as directed
M&L reinforced cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in drain cover slab complete all as specified and as directed.
M&L form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick, complete all as specified and as directed.
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Dismantling floor, hearth or wall tiling or mosiac tiles including cement mortar bedding (but not backing), rmoving servicable tiles to store and rubbish off the premises
M&L for 40 mm thick PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in floors/paving finishing the surface even and smooth without using extra cement concrete complete all as specified and directed.
M & L for vitrified ceramic tiles dark colour 10 mm thick (square/rectangular) polished, area of each tile exc 0.42 sqm and not exceeding 1.00m each in floor and skirting etc set and jointed in neat cement slurry and pointed in white or colour cement to match over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. (double charged/ultra charged)
Demolition of brick work or stone masonary/boulder masonary, built in cement mortar including all quions, arches,pillars etc but excluding ashar facings, dressed stone work and precast article etc and depositing of debris out side MD Land all as specified and directed.
M&L 10 mm thick internal plaster in CM 1:6 on faces of walls , finishing the surfaces even and smooth without using extra cement.
M&L 5 mm thick rendering in CM 1:4 , as in ceiling, finishing the surfaces even and smooth without using extra cement.
M&L preparing new plastered surfaces of ceiling and applying two coats of oil bound distemper complete all as specified.
M&L 3 mm thick wall care putty on wall
Taking down chowkhats or frame not exceeding 1.5 Sq.m each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified.
Taking down chowkhats or frame exceeding 1.5 Sq.m but n.exc 4 sqm each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified.
Taking down shutters any description area n exc. 1.0 Sqm complete
S&F in repairs aluminium body door closer hydraulically regulated designation No 2, universal type suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as directed
S&F in repairs floor door stopper (double headed) of aluminium body and toungue, anodized with hard drawn steel spring 150mm complete all as directed
S & F 4 mm sheet glass, ordinary quality with Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers and glazing with aluminium beads in square exc 0.5 sq.m in each pane
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aparture 1.40mm and fixed with aluminium wire snaples, complete.
S&F pinhead sheet glass 4.8 mm thick, ordinary quality and glazing with rubber beadings suitable for aluminium frame work, in square n.exc. 0.5 sqm in each pane complete all as directed
S&F 9 mm thick pre laminated particle boards exterior grade, prelaminated both sides with decorative chocie laminations fixed in aluminium partions/doors with rubber beadings complete all as directed
S & F sheet glass ordinary quality for 5.50 mm thick and glazing with oil putty in sqm exc 0.50 sqm in each pane complete all as directed
Preparation of old painted steel surfaces of any description over 10 cm girth or width and applying two coat of synthetic enamel paint all as directed by Engineer-in-charge
Providing and fixing of false ceiling system with fine fissured edge tiles having humidity resistance(RH) of 95% NRC 0.34, light reflectance approx 84%, Thermal conductivity K=0.052- 0.057 W/MK, colour white, fire performance of class-I as per BS 476 part 6&7 in module size 600x600x16 mm thick suitable for green building application with recycled content of 38-41% with Armstrong silhoette profile exposed grid system with 15 mm white flanges incorporting a 6 mm central reveal in white/black colour. Silhoutte, main runners & cross Tees to have mitred ends & "birdsmouth" notches to provide mitred cruciform junctions. The Tee sections have a galvanizing of 170 grms per m2 & passed through 500 hrs of salt Test.The main runner spaced at 1200 mm c/c should be securely fixed to the structural soffit using Armstrong suspension system at 1200 mm maximum c/c. The first/last Armstrong suspension system at the end of each main runner should not be greater than 450 mm from adjacent wall Make :Armstrong/Saint Gobain or equivalent
S & F anodised aluminium frame/shutters (powder coated) for doors, windows ventilators with one or more rebates including joining cleat, rubber gaskets, locking arrangement for sliding window etc., for fixing complete all as specified.
Anodised aluminium anodised (powder coated) door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door,aluminum hinges, anodised aluminum snap beading screws etc. complete all as specified.
Anodised aluminium anodised (powder coated) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 No.) suitable handle (1No.) complete all as specified
S&F for venetian blinds, vertical type, 100 mm slot width of approved fabric and powder coated aluminium top railsetc complete all as specified, including dismantlilng old damaged one completecomplete all as specified and as directed. Note:The colour,design and shade shall be as approved by GE Make Vista/Amar
S &F powder coated aluminium grills of approved pattern with aluminium channel/angle frame work weight exc 3.5 Kg/Sqm but n exc 4 Kg/Sqm fixed on windows complete all as directed
M & L for forming toothings for and bonding new work in CM 1:4 including cutting out concrete blocks, slabs, brickwork or stone, masonry (in alternate course), forming toothings for and bonding new work of appropriate material or PCC 1:2:4 type B1 using 20 mm graded stone aggregate set in mortar as specified above into old work, including new materials entering old wall
M&L precast cement concrete 1:2:4, Type B1 in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match
M & L for forming jambs in CM 1:4, etc., to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete
S & F for anodised aluminium frame for doors, window, ventilators with powder coated with one or more rebats including jointing, cleats for fixing extra complete all as specified.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or glazing pin in squares not exceeding 0.50 Sqm in each pane complete all as specified.
Supply and fix for heat absorbing glass of 3 mm thick of any size complete all as specified
S & F Aluminium anodised barrel tower bolts 150 mm length of extruded section complete all as directed
S & F Butt hinges,100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21 complete all as directed
S & F Aluminium handles, cast type anodised oval or 'D' type of size 100mm complete all as directed
M & L 12 mm th prelaminated exterior grade both sides laminated to be fixed in aluminium doors etc.,complete all as directed
M&L lock four lever for aluminium foor grade I, size 75 mm complete all as directed
M & L steel rolling shutters lath thickness 1.25 mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type complete all as specified and directed
M&L for safety lever locks mild steel with 4 leavers for rolling shutters complete
M & L applying two coat of aluminium paint over a coat of newly primed surfaces of rolling shutter including necessary preparation complete all as directed
M&L mild steel stairs (framed) including stringers, treads, landing, balusters, hand rails etc, including cleats, brackets, etc. complete all as directed
S&F Pre-painted galvalume aluminium zinc coating curved shaped GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as directed
M&L preparing new steel surfaces and applying applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
M & L Plain cement concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified and as directed
M&L compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and as directed
M&L Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed
Material and labour for Point wiring complete with mulistranded copper condutors size 1.5 sqmm single core PVC insulated, unsheathed , FRLS cable, 1100 Volts grade conforming to ISI 694, multistrand drawn through and including Rigid PVC non metalic surface / concealed type /casing and caping of suitable size in wall/ceiling, including provision of MS box of suitable size with 3mm thick laminated hylam sheet cover for housing switch, socket, etc including taking down old existing point wiring any type and making good the surfaces complete with provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for the following:-
a) One light point controlled by one way switch 5/6 Amps switch
b) One ceiling fan/exhaust fan controlled by one 5/6 Amps switch
© one light point controlled by Two Nos of 2way switch 6 amps
d) One 3 Pin scoket out lets 5/6 Amps on the same board with other switches switch socket combination 5 Amps on same board
e) One 3 Pin scoket out lets 5/6 Amps on the indepent Board
All as per item No 62 here in before, but for one socket out let 2 in 1, 5 and 15 Amps with 4 Sqmm PVC copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor.
Supply & Fixing switch piano 5/6 Amps one way
Supply and fixing switch piano Type 5/6 Amps two way
S & F socket out let 2 in 1, 3 pin 5 amps
S & F switch socket combination 2 in one, 5 and 15 Amps
Supply and fix ceiling rose surface bakelite two to three terminal .
supply and fixing stepped electronic fan regulator 100 watts ,230 volts
Taking down old unserviceable aluminium sub main wiring & material and labour for sub main wiring complete with 2 runs of 4 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including stove enemelled metalic conduit of suitable size and conduit accessories run on surface of wall/ceiling etc and connecting terminal ends including 1 run of 2.5 sqmm PVC insulated un-sheathed copper conductor cable green colour as contineous earth continuity conductor and connecting to earth dolly complete all as directed. Note : 2 runs of 4 sqmm PVC insulated unsheathed copper conductor and 1 run of 4 sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
Taking down old unserviceable aluminium sub main wiring & material and labour for sub main wiring complete with 4 runs of 6 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including stove enemelled metalic conduit of suitable size and conduit accessories run on surface of wall/ceiling etc and connecting terminal ends including 1 run of 4 sqmm PVC insulated un-sheathed copper conductor cable green colour as contineous earth continuity conductor and connecting to earth dolly complete all as directed. Note : 4 runs of 6 sqmm PVC insulated unsheathed copper conductor and 1 run of 4 sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
Taking down old unserviceable aluminium sub main wiring & material and labour for sub main wiring complete with 4 runs of 10 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including stove enamelled metalic conduit of suitable size and conduit accessories run on surface of wall/ceiling etc and connecting terminal ends including 1 run of 6 sqmm PVC insulated un-sheathed copper conductor cable green colour as contineous earth continuity conductor and connecting to earth dolly complete all as directed. Note : 4 runs of 10 sqmm PVC insulated unsheathed copper conductor and 1 run of 6 sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
Supply and fix in replacement LED fittings Suspended linear in sleek design is suitable for all commercial spaces. Capacity :40W Ca ref LCLP75-40-CDL of CG or equivalent in Bajaj/ Philips.
Supply and fix in replacement LED fittings Recessed/Surface 2X2 Tile design is suitable in all spaces. Capacity :36 W Cat ref LCTLSN-36-CDL of CG or equivalent in Bajaj/ Philips.
Supply and fix in replacement LED tube fitting 20 Watts Make Havells Cat Ref LUMILINEPLUSBS20WLED865SPCWH or equivalent in Bajaj/ Philips.
Supply and fixing of switch modular 1 way 6 amps, 1 module with frame and cover 230 volts complete all as specified
Supply and fixing of switch modular 1 way 16 amps, 1 module with frame and cover 230 volts complete all as specified
Supply & fix ceiling rose surface backlite three terminal complete all as directed
Supply and fixing of socket modular 6 Amps 2/3 pin combined 2 module with frame and cover 230 volts grade complete all as specified
Supply and fixing of socket modular 6/16 Amps 2/3 pin combined 2 module with frame and cover 230 volts grade complete all as specified
M & L for taking down existing old/existing ceiling fan any sweep from the ceiling and kept in safe custody and making good the disturbed surfaces of ceiling etc complete all as specified and as directed
Supply and fixing of 20 amps socket Residual current Device Pootrctrd Socket With Plastic Envclosure for surface mounting for Split AC complete all as specified and as directed Make: Havells/ Legrand
Supply and Efficient LED recessed 2x2 luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free soft ilumnation comlete all as specified and directed by Engr- in -charge Make: Bajaj or equivalent in Cromton/ Philips.
Supply & fix LED battan 4ft 18 watts CDL Compleate fitting complete all as specified and direted by Engr-in -Charge Make ; Bajaj or equivalent in crompton/ philips.
Supply & fix Wall mounting fan 400mm sweep RPM 1320 air delivery 70mm.full copper motor & over thermal protection complete all as specified and directed by Engr- in -charge Make :Bajaj or equivalent Havells,Turbo Force
Supply and fixing Distribution board VTPN MCB Double door DB with IP43 Protection metal door 415 Volts 8 way +18 module compact with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete including comprising the following all as specified and as directed (a) MCB TPN 63 Amps -01 Nos ( incomming) (b)MCB SP 20 Amps - 04-Nos (out Going) (c ) MCB SP 10 Amps 02-Nos (out going) (d) MCB SP 6 Amps-8 Nos ( Out going) blank Cap -08 Nos Make :INDOASIAN/ABB /L&T/Legrand
Taking down MCB DB TPN/SPN and making good to the disturbed wall of any Type complete all as specified and directed.
Taking down old light fitting and making good to the disturbed wall of any Type complete all as specified and directed.
Taking down old Sub main wiring 2 run/4 run with earth cable and and making good to the disturbed area complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity of 2 TR and 220 to 250 volt 50 Hz all as spcified and directed (including copper pipe and refrigerant gas). Make of Split type AC - Blue star /Voltas/LG
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity of 1.5 TR and 220 to 250 volt 50 Hz all as spcified and directed (including copper pipe and refrigerant gas). Make of Split type AC - Blue star /Voltas/LG
S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity 5 KVA. Make-V Gaurd/Oricon/Orient
S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity 4 KVA. Make-V Gaurd/Oricon/Orient
M&L for MS stand duly painted suitable for fixing 1.5 TR and 2 TR AC outdoor unit and fixed complete all as directed.
M & L for HDPE pipe 20 mm dia fixed to wall on roof complete all as directed.
Making opening/drilling of size 65 mm dia, using heavy duty stone driller/cutter machine in the stone machinry wall for installing spilit type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface all as directed.
Taking down / removing of unsericeable main switches /MCB DB / MCB's and supply and fixing of following including making good the disturbed surface to match the existing wall and making necessary connection with suitable size copper wire complete all as specified and as directed.
(a) Supply and Fixing in replacement MCB SP 10 Amps, 10 KA, 250 Volts "C" Curve
(b) Supply and Fixing in replacement MCB SP 20 Amps, 10 KA, 250 Volts "C" Curve
(c) Supply and Fixing in replacement MCB SP 32 Amps, 10 KA, 250 Volts "C" Curve
(d) Supply and Fixing in replacement MCB SPN 32 Amps, 250 Volts "C" Curve
(e) Supply and Fixing in replacement MCB TP 16 Amps, 415 Volts "C" Curve
(f) Supply and Fixing in replacement MCB TP 32 Amps, 415 Volts "C" Curve
(g) Supply and Fixing in replacement MCB TP 40 Amps, 415 Volts "C" Curve
(h) Supply and Fixing in replacement MCB TPN 16 Amps, 415 Volts "C" Curve
(i) Supply and Fixing in replacement MCB TPN 32 Amps, 415 Volts "C" Curve
(j) Supply and Fixing in replacement MCB TPN 40 Amps, 415 Volts "C" Curve
(k) Supply and Fixing in replacement MCB TPN 63 Amps, 415 Volts "C" Curve
Supply and fixing in replacement of MCB DB 2 way Single door type single phase 230 volts
Supply and Fixing in Replacement MCB DB double door type 4 Way with common earth and neutral bus and 200 amps copper bus bars complete, 240 volts
Supply and Fixing in Replacement MCB DB double door type 8 Way with common earth and neutral bus and 200 amps copper bus bars complete, 240 volts
Supply and Fixing in Replacement MCB DB double door type TPN 8way with common earth and neutral bus and 200 amps copper bus bars complete, 415 olts
Supply and Fixing in Replacement MCB DB double door type TPN 4way with common earth and neutral bus and 200 amps copper bus bars complete, 415 olts
Taking down/removing of unserviceable MCB DB TPN, supply and fixing of MCB DB vertical type TPN with MCCB-160 Amps 25 KA 3 pole, 8Way, as incomer with sheet metal enclosure double door type,complete with neutral , earth bus of Make: Legrand cat No.507752,ip 54-IK 09 DPX3 160+24 or equivalent in CG/INDOASIAN
S & F Industrial socket single pole and enclosure with a two pin and earth plug complete with one single pole MCB 20A
Earthing complete with GI earth plate electrode 60cm x 60cm x 6mm size buried directly in ground with bottom edge of the plate not less than 2.25 meters below normal ground level and connected to GI earth lead of size 4mm dia as earth lead by means of nuts bolts etc with and including earth lead upto 7.5RM including necessary excavation, earth chamber with plain cement concrete 1:3:6 type C-1, necessary reinforced cement concrete chamber cover in cement concrete 1:2:4 with nominal reinforcement, funnel etc., all as shown in electrical plate No.3 of SSR Part I, including excavation in any type of strata and connected to earthing test point including testing on completion all as specified and as directed.
Kaveri Enterprise
SAI CONSTRUCTIONS
SREE BUILDERS
ARATHEERTHA CONCEPTS
R R Constructions
Lucky Enterprises
Moulya Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .