| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹28.0 L+₹2.1 L (8.32%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹28.0 L+₹2.2 L (8.48%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹28.4 L+₹2.6 L (10.0%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹28.6 L+₹2.8 L (10.8%)Rejected-Finance NEAR G E COLLEGE RASHOOLPUR MAHARAJPUR GWALIOR MP 475110 | GWALIOR | MADHYA PRADESH | 475110 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹30.4 L
EMD Value
₹60,800
Closing Date
8 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF ADM AREA
GE AF ADM AREA GWALIOR-474020
ADDN/ALTN TO EMERGENCY ROOM AT SMC, S/R TO DINNING HALL OF OFFICERS MESS AND PROVN OF GEYSER IN CERTAIN SMQ OF NCS AT AF STN GWALIOR
2023_MES_625624_1
8364/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF ADM AREA GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF ADM AREA
₹60,800
Yes
10 Feb 2024
30 Oct 2023
16 Dec 2023
30 Oct 2023
8 Dec 2023
13 Nov 2023
Amount
Excavation in trenches n exc 1.5 mtr wide and not exc1.5 mtr depth for foundation and laying of cable, erection of RCC poles and getting out in soft /loose soil complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding & removing serviceable material to store and rubbish off the premises complete all as specified and directed.
Demolition of brick work built in cement mortar or cement line motar as in pillars, brick wall, quoins, arches etc.
M&L for brick work with sub class 'B' bricks old size, straight or curved on plan exc 6M mean radius built in CM 1:6 complete all as specified and directed by the Engineer-in-Charge.
M & L for rendering 15 mm thick on fair faces of brick wall finished fair & smooth in CM 1:6 complete all as specified and directed.
M&L for preparation of old/new painted surfaces of steel/iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed.
S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290 Gde-E-165 complete all as specified and directed.
M&L for two coat of synthetic enamel paint over one coat of red oxide primer on new steel surface of any description not other wise described over 10 cm width or girth complete all as specified and directed.
Taking down old Aluminium work as in windows,frames,ventilators and door shutters n exc 1.5 Sqm and removing to store complete all as specified and directed
Taking down old Aluminium work as in windows,frames,ventilators and door shutters exc 1.5 Sqm but n.exc 4 sqm and removing to store complete all as specified and directed
M&L for plain cement concrete1:2:4 type B2 (using 40mm graded crushed stone aggregates) as in foundaion filling etc, complete all as specified & directed
Removing excavated material n exc 50 m and depositing where directed at level n exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm.Complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix using 20 mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for reinforced cement concrete M-25 design mix using 20 mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and mass concrete complete all as specified and directed
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. Note: All props should be made of steel and necessary arrangments must be made as per site requirement
M&L for Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. Note: All props should be made of steel and necessary arrangments must be made as per site requirement
S&F TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F TMT bars but 6 to 8 mm dia as in stirrups cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L rendering 10mm thick in CM (1:4) on surfaces of brick work or concrete surfaces of wall etc. complete all as specified and as directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,including rolling and movable partitions complete fitting and fixtures as per site requirements all complete as per architectural drawings and the directions of Engineer-in-Charge and as per site requirement.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws including rolling and movable partitions complete fitting and fixtures as per site requirements all complete as per architectural drawings and the directions of Engineer-in-charge and as per site requirement.
S&F powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge
Taking down old ceiling boarding of any type and any size complete all as specified and directed as per site requirements
M&L for POP ceiling by 15mm thick plaster of paris finishing 10mm thick lathing and 5mm thick finishing on ceiling,0.56 thick nominal dia and aperture 1.18mm of wire mesh including dome or one step inside the ceiling design approved by the GE on GI frame work of grid size 605X605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermidiate channel 0.9mm thick having two equal flanges of 15mm each and and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.20m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermidiate channel with connecting clips across the intermidiate channel at 457mm centre to centre including hangers 6mm dia. GI (up to 1200mm length) adusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including white cement putty and two coats of plastic emulsion paint over a coat of primer complete all as specified.complete all as specified and directed and as per site requirements
M& L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including screed bed in C:M (1:6) screed bed grinding and polishing complete
S&F 5.0 mm thick Figured glass, n exc 0.5 sq. m in each pane all as per specified and as directed by Engineer-in-charge.
S&F 5.0 mm thick Figured glass, exc 0.5 sq. m in each pane all as per specified and as directed by Engineer-in-charge.
S&F 5 to 6 mm thick aluminium composite panel fixed to aluminium frame work with aluminium beading. The joints of all panels around the frame work shall be made seamless from all side with the use of silicon or as per manufacturers instructions complete all as specified and directed.
Supply and fixing 5.5 mm thick Sheet Glass ordinary quality and to be fixed with aluminium glazing clip and router beads in square or rectagular, area not exc. 0.50 Sqm in each pane, complete all as specified and as directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty etc, complete all as specified and directed.
S&F Plate girder or single stanchions, built up of one beam (ISMB 300) or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections complete all as specified and directed including all necessary props of steel and as per site requirement
M&L for preparation of new plastered wall surfaces and applying two coat of Oil based distemper over a coat of primer and one coat of 1 mm thick birla putty of same make on walls complete all as specified and directed
M&L for fixing 3-D Wall paper colored and designed as per approved on walls by E-I-C/GE etc. complete all as specified and directed.
Taking down carefully existing unserviceable copper/ aluminium point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators light fittings etc found in serviceable condition shall be removed carefully for reuse in the work and rate for the same is deemed to be included in quoted rated under this iterm . However new fittings/fixtures/accessories shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ.
Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed /Surface PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switchws, sockets, regulators etc including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
Description same as per Srl item No 36.00 here-in-before but, point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board
Description same as per Srl item No 36.00 but point wiring for one 5 pin socket outlet, on same board .
Description same as per Srl item No 36.00 above but, point wiring for one six pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor and 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
M & L for Modular switch flush type single pole one way 6 Amps, 240 volts, 1 Module complete all as specified and directed.
M&L for Modular socket outlet 6 Amps 2/3 Pin comboned two module complete all as specified and directed.
S&F switch Modular socket 6/16 amps, 2/3 Pin combined two module complete all as specified and directed.
S&F Modular switch 1 way 16 amps,1 module complete all as specified and directed.
S&F modular white cover plate with frame 3 module including brass screw complete all as specified and directed.
M&L for modular metal flush box white cover plate with frame 3 module including brass screw complete all as specified and directed.
M & L for switch flush type single pole one way 5/6 Amps, 240 volts, white ivory finish complete all as approved
M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specified and as approved
S&F switch socket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specified and as approved
S&F switch socket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed.
M&L for ceiling rose surface Bakelite two to three terminal, 18 x 50 mm complete all as specified and directed.
Dismaintling & taking out MCB DBs VTPN any size , any type and capacity complete all as specified and directed.
Supply and fixing of sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
Supply and fixing of sheet metal enclosure Double door for DB’s 4 way 415 volts with 200 Amps rated bus bar for Triple pole and neutral l supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
Dismaintling & taking out MCB's/Isolator & metal clade box any size , any type and capacity complete all as specified and directed.
S&F MCB single pole 6 to 32 Amps, 'B' series10 KA ,240 Volts complete all as specified and directed.
S&F MCB Single pole and neutral 40 to 63 Amps, 'B' Series 240 Volts complete all as specified and directed.
S&F 415 volt 10 KA 'C' Curve MCB TPN 40 to 100 Amps complete all as specified and directed.
Disconnecting & taking up or down unserviceable sub main wiring of aluminium/Copper conductor with two run of single core cable and one run of single core earth cable of any description, any size & in any position including taking out existing conduits of any description and making good the disturbed surfaces to the existing surfaces all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit
M&L for surface/concealed sub main wiring as required with two single core FR PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of copper stranded conductor of size 6 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed. Note :- Note Two single core cable and one run of earth copper conductor and conduit shall be measured as one unit
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers including taking down of AC box complete all as specified and directed.
M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed. Note: (i)Excavation/Earth work is deemed to be inclusive in quoted rate. (ii) Cost of r Protection pipe and earth lead upto 7.5mtr in deemed to included in quoted rate.
S&F 3 W LED Warm White recess softline luminaire suitable for ceiling with high brightness LEDs and complete with LED tube with driver and all accessories specified and directed.
S&F12 W LED Warm White recess softline luminaire suitable for ceiling with high brightness LEDs and complete with LED tube with driver and all accessories specified and directed.
Supply & Fix for decorative slim linear LED tube light fitting Warm White 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories including 01 No 20 watt tube rod and connecting the same to ceiling rose with using copper conductor 50/0.020 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed by Engineer in-charge
Supply & Fixing ceilling fans comlete with blades,downrod, electronic regulator and accessories ,230 V ,1200mm Sweep Min air delivery 210 CEM with service value 6.00 BEE .Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply, Laying,jointing & testing cable 1100 Volts grade, stranded aluminum conductor, screened, XLPE insulated, armoured heavy duty laid in trenches /ducs ,floor fixed to wall etc complete all as specified and directed (a) 16sqmm 4 core
M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming all as specified and directed. Note: Punned thickness shall be measured for payment.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Supplying & fixing/lalying 40mm dia GI pipe medium grade for road crossing of cable and on pole and DB cable as in cable protection complete all as specified and directed.
Supplying & fixing/laying 50mm dia GI Pipe, medium grade, for fixing of ceilling fan complete all as specified and directed.
Taking down carefully from existing place ceiling fan and removing to MES store yard Scraping,cleaning & painting with two coats of super enamelled paints (as approved by GE) greasing/oiling and refixing at site complete incl electric connection with three core flxible wire 1.5 sqmm all as specified and directed by Engineer-in-Charge.
Supplying , Fixing & Install hi wall mounted split unit indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR complete all as specified and directed..
Supplying & Fixing voltage stabilizer for automatic opration ,single phase naturally aircooled indoor type & designed for input variation between 170V to 250V with outputvoltage stabilizer at 230V with accuracy of + 2.5-5% and of capacity 5.0 KVA complete.
Supply and fix electric water heater storage type steel body with copper inner tank nd heating element upto 2 KW capacity 25 litre ,BEE 5 star rated complete with all accessories such as ssfty valve ,termostste ,NRV, connection Pipes etc complete all as approved, specified and directed.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 20 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor cable FR all as specified and directed Note: Two run of single core cable with one run of earth wire and conduit shall be measured as one unit.
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as specified.
S&F PVC connections (Heavy Duty),15mm size, 450mm long with brass nuts and washers at ends, suitable for hot and cold water complete all as specified and directed.
Supplying, fixing & grouting new mild steel fastner / bolts with screwed end 14 mm dia & 150 mm long along with one washers and one hexagonal nut at screwed end for mounting the geyser on wall and making good the disturbed surfaces to match with the existing surface & finishes all as directed.
S&F GI tubing 15mm bore medium grade with and including all GI fittings (ISI marked) and fixed to wall, floor and ceiling etc complete all as specified and as directed.
Supplying and fixing stop valve/ angle valve , cast copper alloy, 15mm bore, ISI marked, screwed down high pressure,( Fancy type ) with crutch or butter fly handle and fixed complete all as specified & directed.
Supplying and fixing bib taps, cast copper alloy, 15mm bore, ISI marked, screwed down, (Fancy type ) with crutch or butter fly handle and fixed complete all as specified & directed.
Sunil Traders
m/s vikash Engineers
Lall Electronics
KISHAN CONSTRUCTION COMPANY
M/S YOGANSH CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .