| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹49.8 L+₹2.4 L (5.16%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹53.8 L+₹6.4 L (13.5%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹54.8 L+₹7.4 L (15.5%)Rejected-Finance NO 3 KEMPANNA ROAD MARUTHI SEVA NAGAR POST BANGALORE 560 033 BANGALORE KARNATAKA | BENGALURU URBAN | KARNATAKA | 560033 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹55.9 L+₹8.5 L (18.0%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
12 Jun 2023, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
COMPREHENSIVE MAINT OF AIR COMPRESSOR, SERVO VOLTAGE STABILIZERS FOR BALANCED/ UNBALANCED LOADS, LIFT, FIRE FIGHTING SYSTEM/ FIRE ALARM SYSTEM, EOT CRANE, UPS AND OTHER MISC ITEMS AT AFS SULUR
2023_MES_597214_1
8592/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
26 Jun 2023
22 May 2023
13 Jun 2023
22 May 2023
12 Jun 2023
5 Jun 2023
22 May 2023 - 31 May 2023
Amount
SCHEDULE A BOQ
Comprehensive maintenance of 25KVA true online UPS system with SMF batteries,20 KW with input supply of 3 phase 415V, 50HZ of Make Aplab including attending day to day complaints , isolating UPS from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Location - Instrument Rotable, generator set room.
Note For item No 2 :- (a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers on quarterly basis. Each inspection per location shall be considered as one Job
(b) Cost of any minor items to be replaced is included in the item quoted rate.
(c) Payment shall be made thrice for the period of 11 months proportionately, for comprehensive maintenance.
(d) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate.
(e) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Supply only Cooling fan suitable for 25KVA to 50KVA true online UPS of Make - Aplab all as specified and directed.
Supply only IGBT suitable for 25KVA to 50KVA true online UPS of Make - Aplab all as specified and directed.
Supply only DC Capacitor suitable for 25KVA to 50KVA true online UPS of Make - Aplab all as specified and directed.
Note for item No 8 to 10 :- Cost of labour for fixing and taking down old defective parts with respect to above items has already included in unit rate quoted for comprehensive maintenance.
Comprehensive maintenance of Air compressor 5 HP of Make Shakti 3 Phase including ,checking of airflow line ,oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed. Location - 33 Sqn New Hangar-01 No
Comprehensive maintenance of Electric Powered Screw Air Compressor (EPSAC) Part No : E110-11AC, Free air delivery 16.9 cum/min, working pressure : 10.2 Kg/sqcm, Compressor drive motor -110 KW/ 147.5 HP, RPM-1485 of Make ELGI 3 phase including checking of airflow line, oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/ oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed. Location - LCA ETB Bldg-01 No.
Comprehensive maintenance of Air compressor 5 HP of Make ELGI 3 Phase including checking of airflow line ,oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed. Location - AVRO Hangar-2 Nos.
Comprehensive maintenance of Screw Air compressor (ATLAS) Part No GA110-10, compressor drive motor-110 KW, 10 bar Make : Atlas Copco, 3 phase assembled with Air filter, compressor element, air receiver/ oil separator, air cooler, oil cooler, drive motor, gear casing, unloader, Elektronikon control system, air dryer with bypass valves etc including checking of airflow line, oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/ oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed. Location – LCA ETB Bldg-01 No.
Note for Item No 12 to 15 :- (a) The above comprehensive maintenance shall be done through authorised person of OEM on quarterly basis. Each inspection per location shall be considered as one Job
(b) The contractor shall make AMC contract with the original manufacturer of Air compressor and the repairs/maintenance shall be carried out through the original manufacturers only.
(c) The rate quoted shall be deemed to include to carried out all repairs to air compressor noticed during the period 11 months by providing materials and labour. Interim payments if required shall be made thrice for the period of 11months proportionately.
(d) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate.
(e) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Comprehensive maintenance of goods lift to carry goods of 2000 kg capacity with a speed of 0.5 metre/sec, of Make : Johnson to serve ground floor and three upper floors with AC variable voltage & variable frequency drive(VVVF DRIVE) system, microprocessor based control system all as per IS 14665 with car position indicators on all floors, car position indicators in cabin, battery operated alarm bell and emergency lights ,cabin light & fan over load switch, auto revelling, intercom facility with centre opening, stainless steel power operated sliding doors, including checking the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell , etc. complete all as specified and as directed. Machine No of Lift (L-H8229), Location : DWR Building - 01 No.
Note for Item No 21 : (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only.
(b) The rate quoted shall be deemed to include for carrying out all repairs to lift noticed during the period by providing materials and labour.
(c) Authorized rep of OEM will visit the lift and check it on monthly basis.
Comprehensive maintenance passengers lift to carry 10 passengers (680 Kg) capacity of Make: Johnson to serve ground floor plus four floors, including checking the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc complete all as specified and directed. Machine No of Lift - L/C 7489, Location : SRE Building - 01 No.
Note for Item No 25:- (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only.
(b) The rate quoted shall be deemed to include for carrying out all repairs to lift noticed during the period by providing materials and labour.
(c) Authorized rep of OEM will visit the lift and check it on monthly basis.
Comprehensive maintenance of passengers lift to carry 8 passengers (544 Kgs) capacity with a speed of 1 metre/ sec, of Make: OTIS to serve ground floor and 4 upper floors with AC variable voltage and variable frequency drive (VVVF DRIVE) system, micro processor based controol system all as per IS 14665 hall position indicators on all floors, car position indicators in cabin, battery operated alarm bell and emergency lights including cabin light and fan over load switch, auto revelling, intercom facility with centre opening, stainless steel power operated sliding doors, including examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/ replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc. complete all as specified and directed. Machine No of Lift (MG055702), Location : New ATC Building - 02 Nos.
Note for Item No 29: (a) The contractor shall make AMC contract with the authorised service agency of lift and the repairs/ maintenance shall be carried out through the authorised service agency only. The quoted rate in deemed to be inclusive for comprehensive maintenance of 02 lifts at ATC Building per month
(b) The rate quoted shall be deemed to include for carrying out all repairs to lift noticed during the period by providing materials and labour.
(c) Authorized rep of OEM will visit the lift and check it on monthly basis.
Comprehensive maintenance of goods lift to carry goods of 1000 kg capacity with a speed of 0.5 metre/sec, of Make : KONE to serve ground floor and three upper floors with AC variable voltage & variable frequency drive(VVVF DRIVE) system, microprocessor based control system all as per IS 14665 with car position indicators on all floors, car position indicators in cabin, battery operated alarm bell and emergency lights including cabin light & fan, over load switch, auto revelling, intercom facility with centre opening, stainless steel power operated sliding doors, including Examining the operation, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell , etc. complete all as specified and directed. Location : FMS - 01 No.
Note for Item No 33:- (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only.
(b) The rate quoted shall be deemed to include for carrying out all repairs to lift noticed during the period by providing materials and labour.
(c) Authorized rep of OEM will visit the lift and check it on monthly basis.
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 7.5AH, suitable for passenger/ goods lift as required at location SRE/ DWR/ ATC bldg including initial charging complete with inbuilt charger ,electrolyte/ distilled water etc including taking down of old unserviceable battery and shifting to MES store yard for deposit all as directed by Engineer in Charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron
Note for Item No 37:- (i) The contractor shall submit full replacement warranty certificate for minimum period of 02 years from the date of installation.
(ii) The contractor shall supply SMF battery as and when demanded by Engineer-in-Charge during the currency of contract.
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : Vinitec with input variation between 340V to 470V with output stabilized at 415 Volts of capacity 650KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : MAFI Sub Stn - No 1
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : Vinitec with input variation between 340V to 470V with output stabilized at 415 Volts of capacity 250KVA with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : MAFI Sub Stn - No II
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 75KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location - ATC, TRCD(2 Nos), 152 Radar site, Transmitter, CRRW
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : Vinitec with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 100 KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location - Signal centre
Comprehensive maintenance of 3 phase oil cooled servostabilizer of Make - BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 250KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location - Rubber store
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 15KVA Make-RDC with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : RT Cabin
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 125KVA Make-Power one with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : SRE
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 150KVA Make-BEC with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : DWR
Comprehensive maintenance of 3 phase oil cooled servo stabilizer of Make : BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 50KVA Make-BEC with all spares including isolating stabilizer from system, opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location : T/51 Avionics Lab.
Note for Item Nos 40 to 48 :- The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers on quarterly basis. Each inspection per location shall be considered as one Job
(b) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only.
(c) The rate quoted shall be deemed to include for carried out all repairs to servo stabilizer noticed during the period 11 months.Payment shall be made thrice for the period of 11 months proportionately, for comprehensive maintenance.
(d) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate.
(e) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Supply only Microprocessor board of servo stablizer of capacity 50KVA to 250KVA all as specified and as directed.
Supply only Servo motor suitable for 50KVA to 250KVA all as specified and directed.
Supply only Buck Boost transformer of servo stablizer of capacity 50KVA to 250KVA all as specified and directed..
Supply only Bypass switch of servo stabilizer of capacity 50 KVA to 250KVA all as specified and directed.
Note for item No 54 to 57 :- Cost of labour for fixing and taking down old defective parts with respect to above items has already included in unit rate quoted for comprehensive maintenance.
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 100AH, suitable for existing 3 phase online UPS as required at location including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron
Note for Item No 59:- (i) The contractor shall submit full replacement warranty certificate for minimum period of 02 years from the date of installation.
(ii) The contractor shall supply SMF battery as and when demanded by Engineer-in-Charge during the currency of contract.
Periodical Examination, normal and routine maintenance ,as per manufacturer’s instructions, Repair and periodical maintenance of indoor ,single Girder heavy duty electrically operated travelling (EOT) over head crane capable of handling 3.0 Tonnes capacity – 01 No, suitable for 415 volts, 50 Hz 3 phase, 4 wire, AC supply with clear hook height of 3.5 Mtrs from FFL including floor operated movable pendent control by means of push buttons independent of crab trolley position with protective panel with down shop lead (DSL) trailing cables and earthing etc, complete comprising of (a) class of Duty-CLII as per IS 807 & IS 3938 indoor, (b) Crane span-8.38Mts (c) Longitudinal travel shall be limited to 1.0 m away from the walls on both ends. (d) EOT crane shall be provided with the following electrically controlled. (i) Longitudinal Travel speed-20mpm (100%)-2mpm (10%), (ii) Cross travel speed -12 mpm (100%)-1.20mpm (10%), (iii) Hoisting speed – 6 mpm(100%) – 0.60 mpm (10%), (iv) Longitudinal Travel motor – 2X0.75 HP (SQC), (v) Cross travel motor – 0.5 HP (SQC), (vi) Hoisting motor – 5 HP (SQC) installed at Location – LCA ETB bldg. Make :- Stanmek Ingenieurs
Periodical Examination, normal and routine maintenance ,as per manufacturer’s instructions, Repair and periodical maintenance of indoor ,single Girder heavy duty electrically operated travelling (EOT) over head crane capable of handling 3.0 Tonnes capacity, suitable for 415 volts, 50 Hz 3 phase, 4 wire, AC supply with clear hook height of 5.1 Mtrs from FFL including floor operated movable pendent control by means of push buttons independent of crab trolley position with protective panel with down shop lead (DSL) trailing cables and earthing etc, complete comprise of (a) class of Duty-CLII as per IS 807 & IS 3938 indoor, (b) Crane span-8.38Mts (c) Longitudinal travel shall be limited to 1.0 m away from the walls on both ends. (d) EOT crane shall be provided with the following electrically controlled. (i) Longitudinal Travel speed-20mpm (100%)-2mpm (10%), (ii) Cross travel speed -12 mpm (100%)-1.20mpm (10%), (iii) Hoisting speed – 6 mpm(100%) – 0.60 mpm (10%), (iv) Longitudinal Travel motor – 2X0.75 HP (SQC), (v) Cross travel motor – 0.5 HP (SQC), (vi) Hoisting motor – 5 HP (SQC) Make : ROCKWELL installed at Location – FADEC bldg-2 Nos.
Periodical Examination, normal and routine maintenance ,as per manufacturer’s instructions, Repair and periodical maintenance of indoor, single Girder heavy duty electrically operated travelling (EOT) over head crane capable of handling 2.0 Tonnes capacity – 03 Nos, suitable for 415 volts, 50 Hz 3 phase, 4 wire, AC supply with clear hook height of 3.5 Mtrs from FFL including floor operated movable pendent control by means of push buttons independent of crab trolley position with protective panel with down shop lead (DSL) trailing cables and earthing etc, complete comprising of (a) class of Duty-CLII as per IS 807 & IS 3938 indoor, (b) Crane span-8.10Mts (c) Longitudinal travel shall be limited to 1.0 m away from the walls on both ends. (d) EOT crane shall be provided with the following electrically controlled. (i) Longitudinal Travel speed-20mpm (100%)-2mpm (10%), (ii) Cross travel speed -12 mpm (100%)-1.20mpm (10%), (iii) Hoisting speed – 6 mpm(100%) – 0.60 mpm (10%), (iv) Longitudinal Travel motor – 2X0.5 HP (SQC), (v) Cross travel motor – 0.33 HP (SQC), (vi) Hoisting motor – 4 HP (SQC) installed at Location – FADEC, LCA ETB & FMS Bldg. Make :- ROCKWELL/ Stanmek Ingenieurs/RANK
Note For item No 62 to 64 :- (i) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers on quarterly basis. Each inspection per location shall be considered as one Job
(ii) Any minor items to be replaced is deemed to be included in the unit rate quoted.
(iii) The contractor shall provide visit/inspection of service engineer of authorised dealer for servicing of the eqpt in each quarter i.e on quarterly basis and on phone call for attending emergency brake downs during the entire contract period.
Comprehensive maintenance of 40KVA static frequency converter with input supply of 3 phase 415V,50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Location - Generator Room.
Comprehensive maintenance of 30KVA static frequency converter with input supply of 3 phase 415V, 50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system, Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Location - Generator Room.
Comprehensive maintenance of 20KVA static frequency converter with input supply of 3 phase 415V, 50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system, Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Location - CRRW.
Comprehensive maintenance of 25KVA static frequency converter with input supply of 3 phase 415V, 50HZ with output of 115 V, 400HZ. of Make Aplab including attending day to day complaints, isolating converter from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Location - Generator Room
Comprehensive maintenance of DC power supply (Rectifier)28 Volts DC Output, 20 KW with input supply of 3 phase 415V, 50HZ of Make Aplab including attending day to day complaints, isolating converter from system, Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Location - Generator Room.
Comprehensive maintenance of DC power supply (Rectifier)28 Volts DC Output, 15 KW with input supply of 3 phase 415V, 50HZ of Make Aplab including attending day to day complaints, isolating converter from system, Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Location - Generator Room, Instrument Rotable section.
Note for Item No 68 to 73 :- (a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers on quarterly basis. Each inspection per location shall be considered as one Job .
(b) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carried out through the original manufacturers only.
(c) Cost of any minor items to be replaced is included in the item quoted rate.
(d) Payment shall be made thrice for the period of 11 months proportionately, for comprehensive maintenance.
(e) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate.
(f) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Supply only Cooling fan suitable for 5KVA to 40KVA Frequency converter of Make - Aplab all as specified and directed.
Supply only DC Capacitor suitable for 5KVA to 40KVA Frequency converter of Make - Aplab all as specified and directed.
Supply only IGBT suitable for 5KVA to 40KVA Frequency converter of Make - Aplab all as specified and directed.
Note for Item No 80 to 82 :- Cost of labour for fixing above items has already included in unit rate quoted for comprehensive maintenance.
M&L Calibration of load testing with certification through Govt authorised dealer for Electrically operated single girded EOT Crane 3.0 Ton capacity with power supply of 3 phase 415V, 50 Hz suitable for 8.38 Mtr span and 3.5 Mtr height of lift hooks, pendent type operation Make-Stanmek Ingenieurs as directed by Engineer-in-Charge.
Note for Item No 84 : Quoted rate is deemed to be inclusive of T&P items and Dummy loads as required at site for load testing.
M&L Calibration of load testing with certification through Govt authorised dealer for Electrically operated single girded EOT Crane 2.0 Ton capacity with power supply of 3 phase 415V, 50 Hz suitable for 8.10 Mtr span and 3.5 Mtr height of lift hooks, pendent type operation Make- Stanmek Ingenieurs/ RANK as directed by Engineer-in-Charge.
Note for Item No 86 : Quoted rate is deemed to be inclusive of T&P items and Dummy loads as required at site for load testing.
Supply and replacement of defective Rotary upper limit switch suitable for EOT Crane 3 ton capacity of Make STAN MEK installed at LCA ETB bldg complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of defective wire rope of size 10mm dia, 32 mtrs length, constructed as 6 x 36 cons, FMC, 180 Kg/ Sqmm, FIBRE CORE, suitable for 3 ton EOT Crane complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of defective Rotary upper limit switch suitable for EOT Crane 2 ton capacity of Make STAN MEK/ RANK installed at LCA ETB bldg complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of defective wire rope of size 8mm dia, 25 mtrs length, constructed as 6 x 36 cons, FMC, 180 Kg/ Sqmm, FIBRE CORE, suitable for 2 ton EOT Crane complete all as specified and directed by Engineer-in-Charge.
Periodical servicing and maint of electric operated hanger door comprising of 3 phase, 415V, 5.5 KW/ 7 HP capacity induction motor of Make - Siemens, 7HP VFD panel, chain pulley arrangement, push button for forwarding/ reverse movement of the doors, relays, limit switches, contactors, gear wheels, siren, ammeter and voltmeter, indicating lamps, MCB SP/ SPN of various capacities and suitable connecting cable etc. complete all as specified and directed by Engineer-in-Charge. Location - LCA Hangers - 03 Nos, GHE-02 Nos (Total- 05 Nos)
Note for Item No 92 :- (a) Each hanger consists of 04 Nos of electric operated door. Periodical servicing for each hangar door shall be considered as one Job
(b) Preventive maintenance of each hanger door i.e greasing, reallignment, welding will be done by Service engineer from M/s Siemens on quarterly basis.
(c) The unit quoted rate shall deemed to be included to carried out all repairs noticed.
(d) Repairs/ maintenance shall be carried out through the experinced service agency only.
(e) The service agency must be attended as and when called for urgent nature of repair of hanger door irrespective of number of visit.
(f) Replacement of minor items shall be included in the unit quoted rate.
(g) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding whether the defective item is major or minor in nature.
M&L for rewinding of burnt electric induction motor of 3 phase, 415 volts, 5.5 KW/ 7 HP Make - Siemens including disconnecting electric connections/ taking down and shifting to local workshop and brought back to site and re-assembling, connecting, testing complete all as directed by Engineer-in-Charge.
Supply only air compressor lubricating oil suitable for air compressors of make ELGI/Ingersoll/Shakti complete all as specified and directed.
Lucky Enterprises
devan enterprises
M AND V ENTERPRISES
D.R ASSOCIATES
rvelectricals
LAKSHMI ELECTRICAL ENTERPRISES
S.RAMACHANDRAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .