Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹33.9 L+₹2.0 L (6.33%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹36.7 L+₹4.9 L (15.2%)Rejected-Finance 05 MR PRASHANT DESHMUKH PLOT NO 05 SHUBHALAKSHMI APARTMENT ADHYAPAK LAYOUT HINGNA T POINT NAGPUR 440036 MH NAGPUR | NAGPUR | MAHARASHTRA | 440036 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹36.8 L+₹4.9 L (15.5%)Rejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹38.6 L+₹6.7 L (21.0%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | Bharat Trading Company L1 | Diamond Electric Co. L9 | K R GUPTA AND SONS L8 | M/S VIJAY SINGH L5 | Vijaypower Generators Limited L7 | Success PEB and Infra Consultants L2 | Charan sales and Service L4 | GLOBAL POWER SYSTEMS L3 | M/S SHIV BALLABH MISHRA L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches , not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed. | 80 | Cum | 60 ₹4,800 Lowest | 200 ₹16,000 | 120 ₹9,600 | 80 ₹6,400 | 399 ₹31,920 | 150 ₹12,000 | 250 ₹20,000 | 185 ₹14,800 | 140 ₹11,200 |
| 2.00 | Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed. | 50 | Cum | 10 ₹500 Lowest | 75 ₹3,750 | 50 ₹2,500 | 40 ₹2,000 | 21 ₹1,050 | 120 ₹6,000 | 250 ₹12,500 | 50 ₹2,500 | 40 ₹2,000 |
| 3.00 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 30 | Cum | 20 ₹600 Lowest | 75 ₹2,250 | 50 ₹1,500 | 30 ₹900 | 21 ₹630 | 350 ₹10,500 | 250 ₹7,500 | 50 ₹1,500 | 50 ₹1,500 |
| 4.00 | M&L for natural river sand as cushioning of cables including spreading and punning down complete all as specified and as directed.
Note : Punned thickness shall be measured for payment purpose | 24 | Cum | 450 ₹10,800 | 525 ₹12,600 | 500 ₹12,000 | 525 ₹12,600 | 700 ₹16,800 | 2,000 ₹48,000 | 250 ₹6,000 Lowest | 550 ₹13,200 | 600 ₹14,400 |
| 5.00 | Supply , laying, jointing and testing of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 240 | RM | 590 ₹1,41,600 Lowest | 775 ₹1,86,000 | 670 ₹1,60,800 | 618 ₹1,48,320 | 814 ₹1,95,360 | 1,250 ₹3,00,000 | 700 ₹1,68,000 | 800 ₹1,92,000 | 650 ₹1,56,000 |
| 6.00 | Supply , laying, jointing and testing of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 130 | RM | 750 ₹97,500 | 1,015 ₹1,31,950 | 850 ₹1,10,500 | 718 ₹93,340 Lowest | 1,037 ₹1,34,810 | 1,500 ₹1,95,000 | 1,000 ₹1,30,000 | 1,000 ₹1,30,000 | 850 ₹1,10,500 |
| 7.00 | M&L 80 mm bore galvanised iron pipe, light grade with all fittings, laid in trenches,under roads, drain paths, fixed to poles/walls with mild steel clamps, bolts, nuts and washers complete all as specified and as directed. | 10 | RM | 280 ₹2,800 | 450 ₹4,500 | 250 ₹2,500 Lowest | 330 ₹3,300 | 816 ₹8,160 | 1,200 ₹12,000 | 1,000 ₹10,000 | 800 ₹8,000 | 250 ₹2,500 Lowest |
| 8.00 | Supply and laying sub class 'B' bricks old size designation 75 as in cable protection complete all as specified and directed. | 2.4 | 1000 Nos | 3,500 ₹8,400 Lowest | 6,500 ₹15,600 | 5,000 ₹12,000 | 4,500 ₹10,800 | 7,200 ₹17,280 | 7,800 ₹18,720 | 15,000 ₹36,000 | 8,500 ₹20,400 | 4,500 ₹10,800 |
| 9.00 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine of dia 150mm complete all as specified and as directed. | 6 | RM | 200 ₹1,200 | 1,750 ₹10,500 | 100 ₹600 Lowest | 350 ₹2,100 | 900 ₹5,400 | 2,000 ₹12,000 | 1,000 ₹6,000 | 1,500 ₹9,000 | 300 ₹1,800 |
| 10.00 | Supply, commissioning erecting and testing complete of manufacturer or OEM manufactured, static silient (sound proof enclosure) Diesel Engine driven Generating set of capacity 250 KVA, water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz,348 Amp current rating at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Bamrauli (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height), anti-vibration pads complete all as specified and directed, including all feature to comply with latest CPCB-IV guidelines and comprising of followings:-
(A) DIESEL ENGINE :- Diesel engine 1500 RPM, direct injection,06 cylinder, four stroke, conforming to conforming to IS:100001/ISO 3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 250 KVA at outdoor atmospheric conditions at Bamrauli ( Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:- | 1 | Each Job | 26,50,000 ₹26,50,000 | 39,20,000 ₹39,20,000 | 34,20,000 ₹34,20,000 | 33,60,000 ₹33,60,000 | 32,90,100 ₹32,90,100 | 24,64,000 ₹24,64,000 Lowest | 31,00,000 ₹31,00,000 | 29,75,000 ₹29,75,000 | 33,60,000 ₹33,60,000 |
Tender Value
₹43.8 L
EMD Value
₹87,600
Closing Date
9 Apr 2026, 6:00 pmClosed
CWE(AF) Bamrauli
HQ CWE(AF) Bamrauli Prayagraj 211012
PROVN OF DG SET ALONGWITH ASSOCIATED WORKS AT PHAPHAMAU AIRFIELD UNDER GE (AF) BAMRAULI
2026_MES_756771_1
87590/C/E8
Open Tender
Civil Works
Item Rate
182 days
BAMRAULI
MES Enlisted Contractor of Class D category b i
8 documents required · 8 mandatory
₹500
GE(AF) BAMRAULI
₹87,600
Yes
15 May 2026
18 Mar 2026
16 Apr 2026
18 Mar 2026
9 Apr 2026
2 Apr 2026
18 Mar 2026 - 25 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches , not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed. | 70 | Cum | 1.25 | ₹87.5 |
| 2 | Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed. | 52 | Cum | - | - |
| 3 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. | 18 | Cum | 100 | ₹1,800 |
| 4 | M&L for natural river sand as cushioning of cables including spreading and punning down complete all as specified and as directed.
Note : Punned thickness shall be measured for payment purpose | 21 | Cum | 53 | ₹1,113 |
| 5 | Supply , laying, jointing and testing of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 240 | RM | 10 | ₹2,400 |
| 6 | Supply , laying, jointing and testing of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 130 | RM | 11 | ₹1,430 |
| 7 | M&L 80 mm bore galvanised iron pipe, light grade with all fittings, laid in trenches,under roads, drain paths, fixed to poles/walls with mild steel clamps, bolts, nuts and washers complete all as specified and as directed. | 10 | RM | 11 | ₹110 |
| 8 | Supply and laying sub class 'B' bricks old size designation 75 as in cable protection complete all as specified and directed. | 3 | 1000 Nos | 53 | ₹159 |
| 9 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine of dia 150mm complete all as specified and as directed. | 6 | RM | 10 | ₹60 |
| 10 | Supply, commissioning erecting and testing complete of manufacturer or OEM manufactured, static silient (sound proof enclosure) Diesel Engine driven Generating set of capacity 250 KVA, water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Bamrauli (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height), anti-vibration pads complete all as specified and directed, including all feature to comply with latest CPCB-IV guidelines and comprising of followings:-
(A) DIESEL ENGINE :- Diesel engine 1500 RPM, direct injection,06 cylinder, four stroke, conforming to conforming to IS:100001/ISO 3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 250 KVA at outdoor atmospheric conditions at Bamrauli ( Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:- | 1 | Each Job | 11 | ₹11 |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
87590TENDERDOCUMENTS.pdf
Tender Documents • 1.08 MB
BOQ_847691.xls
BOQ • 1.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .