Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹51.5 L+₹89,030 (1.76%)Rejected-Finance | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹52.1 L+₹1.5 L (2.92%)Rejected-Finance | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹52.2 L+₹1.5 L (3.06%)Rejected-Finance | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹53.0 L+₹2.4 L (4.69%)Rejected-Finance | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
29 Sept 2023, 5:00 pmClosed
LT COL BIRENDRA SINGH
GE 859 EWS PIN- 913859 C/O 99 APO
PROVISION OF WATER STORAGE TANK IN QUARTER GUARD AND MT AREA FOR WATER STORAGE, STAINLESS STEEL RAILING AND CHEQUERED TILES AND SPECIAL REPAIR REPLACEMENT OF OLD U S UNDERGROUND CABLE, SECURITY LIGHTS STEEL TUBULAR POLES CONTROL PANELS AND CONNECTED
2023_MES_617712_1
8452/E8
Open Tender
Civil Works
Item Rate
270 days
BAISAKHI
pl refer tender documents
7 documents required · 7 mandatory
₹500
GE 859 EWS
₹99,000
Yes
29 Nov 2023
8 Sept 2023
30 Sept 2023
8 Sept 2023
29 Sept 2023
22 Sept 2023
Amount
S&F & testing commissioning of outdoor type bus bar panel pedestal type weather proof CPRI approved MS cubical panel board outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 300 Amp capacity & MCCB 160 Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. The panel shall be fixed over Angle iron frame (50 x 50 mm) of minimum height 75 cm Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 8.5 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with two coats of aluminium paint over one coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately.
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 16 sqmm 4 core including taking down of old unserviceable UG cable/service wires.
Description all as per item No 3 above but of size 16 Sqmm 2 core
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard & densile soil complete all as specified and as directed.
Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete casted with PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregateall as specified and directed
M&L PCC in mix 1:4:8 type D2 with 40 mm graded aggregate for poles / stays foundation and fitting in mass concrete
M&L for PCC 1:3:6 Type C2 for erection of pole in base, foundation, mass concrete with 40 mm gradede coarse agreegete complete all as specified and as directed.
Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity including replacement of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to LED light throgh copper connectos all as specified and directed. Make: Havells/Bajaj/Philips
S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 40 mm dia, medium grade, 1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed.
S&F in replacement of PVC insulated copper cable 2.5 Sqmm 3 core from junction box to security light all as specified & directed.
S&F in replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacitywith 6 Amp MCB single pole , of minimum size 250x200x100mm, IP 66 fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
S&F 3 layer 50 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F 3 layer 40 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F 3 layer 25 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
S&F PVC water storage tanks of 5000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed.
S&F PVC water storage tanks of 2000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed.
Supply and fix 50 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 40 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 25 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Ball brass valves, high pressure, with polythene float and flynut complete of PPR pipe of size 50 mm dia, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Ball brass valves, high pressure, with polythene float and flynut complete of PPR pipe of size 25 mm dia, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting existing 50 mm PPR pipe and making fusion joint etc.
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting existing 40 mm PPR pipe and making fusion joint etc.
S&F Bib tap cast copper alloy with crutch or butterfly handle, fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge.
M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete.
M & L for 15mm thick rendering on fair faces of brick,stone work/concrete surfaces of wall in CM (1:4), finished surface even and smooth without using extra cement complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in any type of soil.
M&L for PCC type B-2, 1:2:4 (40mm graded agg) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases).
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
Surface dressing n exc 15 cm deep in hard/dense soil complete all as specified and directed.
M&L for Hard core, broken to gauge n exc 63 mm using broken stone or boulders complete all as specified and directed.
M&L for Sub base Cement concrete type D-2, 1:4:8 (40mm graded aggregate) 75 mm thick complete all as secified and directed by Engr-In-Charge.
M&L for 20mm thick Screed bed or bedding layer of cement mortar 1:6 for laying floor finishes complete all as specifie as directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment comlete all as secified and directed by Engr-In-Charge.
M&L for Providing, cement concrete type B1 (1:2:4) using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges comlete all as secified and directed by Engr-In-Charge.
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete.
M/S DKT CONSTRUCTION
M/S Karkies Construction & Co.
M/S SM ANSARI
M/S ASHOK CONSTRUCTION
M/s Roltso Enterprises
M/S SUNRISE CONSTRUCTION AND CO
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .