Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC N S T COLONY CIRCULAR ROAD HOUSE NO 04 DMC DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.0 L+₹80,380 (8.71%)Rejected-Finance NEAR RAM JANAKI HIGHER SECONDARY SCHOOL H NO 03 THAKURBAR DIMAPUR NAGALAND 797112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹10.6 L+₹1.4 L (15.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
3 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Zakhama
AGE (I) Zakhama C/o 792 FPO PIN-900792 C/O 99 APO
REPAIR AND REPLACEMENT OF VARIUOS TYPES OF STREET LIGHTS AND CONNECTED WORKS AT ZAKHAMA MILITARY STATION UNDER AGE(I) ZAKHAMA.
2025_MES_706746_1
8420/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Zakhama
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
AGE (I) Zakhama
₹18,400
25 Jun 2025
6 May 2025
6 Jun 2025
6 May 2025
3 Jun 2025
20 May 2025
Amount
S & F in repair LED street light of capacity 90 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95, CCT≥5500, IP66, impact resistance IK 07, inbuilt protection against lightning , over voltage, short circuit and surge/spike protection device upto 10kV complete complete all as specified and as directed. all as specified and as directed.
S & F in repair LED street light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95, CCT≥5500, IP66, impact resistance IK 07, inbuilt protection against lightning , over voltage, short circuit and surge/spike protection device upto 10kV complete complete all as specified and as directed. all as specified and as directed.
S & F in repair LED flood light of capacity 70 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95, CCT≥5500, IP66, impact resistance IK 07, inbuilt protection against lightning , over voltage, short circuit and surge/spike protection device upto 10kV, complete all as specified and as directed. all as specified and as directed.
S & F in repair LED flood light of capacity 120 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95, CCT≥5500, IP66, impact resistance IK 07, inbuilt protection against lightning , over voltage, short circuit and surge/spike protection device upto 10kV, complete all as specified and as directed. all as specified and as directed.
S & F in repairs post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lampcomplete all as specified and as directed. all as specified and as directed. Note: For item No 1 to 5 Contractor have to write date of changing in bold letter using permanent marker and submit minimum two years manufacturer warrantee certificate with purchase voucher on completion of work.
S & F in repairs junction box suitable for 3 phase/4 core made out of FRP sheet with weather proof canopy and locking screw fitted with and incl 6 Amps, MCB SP - 1 No, 20 Amps rated 4 Way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel tubular /rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolts complete all as specified and as directed.
S & F in repairs sheet metal enclosure when MCB to be used 2 way, Single pole & neutral without bus bar complete all as specified and asdirected.
S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F in repairs, multicore PVC 1.5sqmm 3 core copper cable for connection of street lights, complete all as specified and as directed.
S & F in repairs street light bracket made of GI pipe 40 mm bore light grade(bend to shape) , 1.2 metre long and fixed with Ms flat iron clamp(clamp shall be 40 X 5mm ), nuts, bolts and washers on pole complete all as specified and as directed.
Taking down defective street/ flood light fittings of any wattage from height upto 11metre pole for repairs and refixing the same,after removing the carbon/ deposit forein materials to make fuctional, replacing defective accessories like LED driver, SPD, PVC insluted sheathed copper conductor etc if required complete all as specified and as directed. (Note :For New spare parts/components of street light fittings shall be measured and paid separately under respective items as supply only however, screws, insulation sleeves, nuts, bolts, washers and PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmm X 3 core from light fitting to Street light feeder (max 1.5 metre ) deemed to be included in quoted rate.)
Supply only constant current LED driver suitable for LED luminaries of wattage of 90 Watt complete all as specified and as directed
Supply only constant current LED driver suitable for LED luminaries of wattage of 60/70 Watt complete all as specified and as directed
S&F in repairs, timer switch analouge type along with power contactors and relay with 230V coil and handle manual override for test and repair function, carried out via the handle paramanent "ON" or "OFF" without automatic closing of the contactor of 63Amps with inbuilt fuction for switching on/off street light according to the complete with all connection to existing panel, complete all as specified and directed. Make : Legrand, Cat NO. 4127 and Contactor 4125 47/48 or equivalent make of Havells / L&T/ ABB / Schneider as approved by AGE(I)
SHRIi Bachulal shah (BID ID -3305706)
Rameshwar Prasad (BID ID -3310682)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .