Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹44.5 L+₹1.7 L (4.01%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST TENDERER | |
| 3 | L3₹45.4 L+₹2.6 L (6.19%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST TENDERER |
Tender Value
₹49.9 L
EMD Value
₹99,700
Closing Date
28 Feb 2025, 6:00 pmClosed
VIPIN CHANDRA RAI
GARRISON ENGINEER UTILITY BATHINDA
REPAIR/MAINT UPS/SVRS AND APFC PANEL AND CONNECTED ACCESSORIES UNDER GE UTILITY BATHINDA
2025_MES_695879_1
8865/2024-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER UTILITY BATHINDA
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER UTILITY BATHINDA
₹99,700
Yes
20 Mar 2025
31 Jan 2025
3 Mar 2025
31 Jan 2025
28 Feb 2025
14 Feb 2025
Amount
M&L for servicing and cleaning of any capacity of UPS and transporting to workshop if neccessory, checking , testing and locating faults including repairing to same by replacing new spares at work site, working electrical connection complete. (Note: Major Spare parts replaced shall be measured and paid separately as supply only item)
Supply only in replacement of PCB suitable for 20 to 30 KVA UPS all as specified & directed by Engr-in- charge
Supply only in replacement of PCB suitable for 2 to 15 KVA UPS all as specified & directed by Engr-in- charge
Supply only in replacement of Transformer suitable for 10 to 30 KVA UPS all as specified & directed by Engr-in- charge
Supply only in replacement of IGBT suitable for 2 to 30 KVA UPS all as specified & directed by Engr-in- charge
Supply only in replacement of capacitor suitable for 2 to 30 KVA UPS all as specified & directed by Engr-in- charge
Supply only in replacement of lead acid battery 12volt 42AH all as specified and directed by Engr-in charge
Repair and Maintenance of APFC panel upto 300 KVAR rating by replacing defective parts i.e contactors, MCB, MCCBs, capacitors, relay, indication lamps, auto manual switch, push button, cooling fan, SMPS, CTs, relay junction point/ connector etc. and blowing of dust by air blower, repair of panel doors by providing hinges, locking arrangement or fixing of new door of existing size including checking the wiring of panel and connection of capacitor if found faulty replace with existing size of copper wire with complete testing of APFC relay including necessary setting with CTs load adjustment to match the power factor in range between 0.96 to 0.99.complete all as directed as specified by Engr in Charge.Note:- All unserveciable Items replaced under repair and servicing of APFC panel shall be measured and paid separately as "supply only" as described hereinafter in respective items
Supply only of capacitor duty contactor heavy duty type 3 pole AC of capcity of 10 KVAR along with 1 No + 1 NC auxilary contact as directed
Supply only of capacitor duty contactor heavy duty type AC of capcity of 15KVAR along with 1 No + 1 NC auxilary contact as directed
Supply only capacitor duty contactor heavy duty type AC of capcity of 20 KVAR along with 1 No + 1 NC auxilary contact as directed
Supply only of capacitor duty contactor heavy duty type AC of capcity of 25KVAR along with 1 No + 1 NC auxilary contact as directed
Supply only of capacitor duty contactor heavy duty type AC of capcity of 5 KVAR along with 1 No + 1 NC auxilary contact as directed
Supply only APFC relay/PLC source type with protection device intelligent automatic processor has on electric controller unit up to 12 stage for contactor type APFC panel and thyristor based APFC panel with 3 CT input all as specified and directed by engr-in charge
Supply only cast resin type CT coil suitable for amp meter 200/5 amp ratio complete all as directed
Supply only cast resin type CT coil suitable for amp meter 800/5 amp ratio complete all as directed
Supply only cast resin type CT coil suitable for amp meter 400/5 amp ratio complete all as directed
Supply only of MPP capacitor 440 volts 50 HZ electric complete of capacity 10 KVAR cyllindrical type gas filled as directed
As per item no. 18 above but for rating 15KVAR.
As per item no. 18 above but for rating 20KVAR.
As per item no. 18 above but for rating 25KVAR.
As per item no. 18 above but for rating 5KVAR.
Supply only of indicating lamp RYB including connection for capacitors as directed
Supply onlyof Auto manual switch for APFC panel as directed
Supply only in replacement of MCCB 63Amp 3Pole, 415volt, 50 Hz 36ka adjustable type complete all as specified and directed by Engr-in charge
Supply only in replacement of MCCB 100Amp 3Pole, 415volt, 50 Hz 36ka adjustable type complete all as specified and directed by Engr-in charge
Supply only in replacement of MCCB 400Amp 4Pole, 415volt, 50 Hz 36ka adjustable type complete all as specified and directed by Engr-in charge
Material and Labour for repairing the LT panel board body by replacing with new CRCA sheet of existing gauge size and shape for door / body of Pane/feeder pillar box, with hinjes and door lock should be well welded complete all as specified and as directed.
Material and Labour for Preparation of old painted surfaces of feeder piller box / panel of any size any description and in any position including removel of faded & deteriorated paint either by hand scrubbing or by blow lamps , applying necessary filler coat and scrapping as required and applying two coats of synthetic enamelled paint (grey in colour) inside and outside of panel with using spray machine over a coat of primer complete all as specified and as directed.
Supply, fixing, connecting and testing in replacement of APFC Panel of capacity 125 KVAR (Output) @ 440Vac. The stage ratings shall be 1x2 KVAR + 1x3 KVAR + 2X 5KVAR + 1X 10KVAR+ 2x25kvar + 1 x50 KVAR .The degree of protection of enclosures system of the APFC Panel shall be min. IP54. The APFC Panel shall be OEM made , machine pressed , dust and vermin proof , indoor type , Panel internally and externally shall be painted with expoxy powder coating paint & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading.The panel mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer , As equipment shall be comprising of the following:- Make:- Havells, Legrand, L&T
Insulated bus bar pan assembly made from Copper suitably rated capacity.
The incomer of the APFC Panel shall be a suitable rated, MCCB.
Capacitor Units: The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of: 2.5 In, operating losses less than 0.5W/KVAR and peak inrush current shall be <200x In.
Short-circuit and Overload Protection: Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 36kA.
PF Regulator/ APFC Relay: Advanced Range PF Regulator / micro-processor based APFC relay having 12 steps with a LCD Display, Voltage Range: 90V - 550V, 50 / 60Hz, CT Input: 1A/5A with a built in RS 485 communication port.
Stage Contactor: The capacitor duty contactors shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks.
Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, contactors, breakers etc.
Indication Lamp, Push button (Start and Stop) and Auto/Manual switch to be install for each stage of capacitor on Panel.
As per item no. 30 above but for rating 100KVAR of stage 1x2 KVAR + 1x3 KVAR + 1X 5KVAR + 1X 10KVAR+ 4x20kvar
As per item no. 30 above but for rating 75KVAR of stage 1x2 KVAR + 1x3 KVAR + 2X 5KVAR + 2X 10KVAR+ 2x20kvar
As per item no. 30 above but for rating 50KVAR of stage 1x2 KVAR + 1x3 KVAR + 1X 7.5KVAR + 3X 12.5KVAR
As per item no. 30 above but for rating 30KVAR of stage 1x2 KVAR + 1x3 KVAR + 3X 5KVAR + 1X 10KVAR
Supply,Laying and testing in replacement of XLPE LT Cable of size 240 Sqmm, 3.5 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge.
As per item no 35 but for cable size 185 Sqmm 3.5 core.
Note: The contractor shall deposited the old material retrieved to AGE EM store yard by his own arrangement without any financial benefit and shall maintain the record for the same as specified by Engr-In-Charge and GE.
AJ. Owners (BID ID -3243834)
PREM ENTERPRISES (BID ID -3245397)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .