Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹63.9 LAccepted-AOC | 1st | Accepted-AOC Resposive Bidder | |
| 2 | 2nd₹70.9 L+₹7.0 L (10.9%)Rejected-Finance | 2nd | Rejected-Finance Rates are higher than lowest bidder | |
| 3 | Rejected-Technical NOT AVAILABLE | NEW DELHI | DELHI | 110001 | - | Rejected-Technical Bidder has not fulfill the DNIT Clause 3 (g) |
Tender Value
₹65.5 L
EMD Value
₹1.3 L
Closing Date
16 Jul 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer DWSS Moga
Room No. 313 3rd Floor Jhelum Chenab Complex DAC Moga
Augmentation of WSS Bijapur and Gatti Kamal Ke
2021_WB_66709_1
2021/WB/BijapurGattiKamalKe
Open Tender
Civil Works - Water Works
Item Rate
300 days
Village Bijapur
Please refer Tender documents.
9 documents required · 9 mandatory
₹1
₹1.3 L
29 Nov 2021
9 Jun 2021
16 Jul 2021
9 Jun 2021
16 Jul 2021
9 Jun 2021
90 days
Amount
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
(b) Boring with 200mm I/d Housing Pipe
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore.
150mm Steel Strainer (slot size 0.15/0.20mm) 5.0 mm thickness
Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect.
150 mm internal dia meter
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
150 mm internal diameter
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.
150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
150 mm internal diameter
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-incharge
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical analysis).
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Provision for Uranium in water testing
Construction of New RCC OHSR of 25 KL (25000 litres) capacitiy with sill level not less than 15.50m height upto FSL 17.20 mtr from ground level, complete with external R.C.C. stair case with landing slabs at each staging, R.C.C. roof, ventilator, Automatic Water level control device, single manhole cover, lightening conductor, plinth protection, water level indicator, providing, fixing and laying of rising main and delivery main to be connected to existing pipeline network etc. complete, duly tested and handed over in proper working order to the Engineer. The construction shall be as per standard drawing of DWSS. Cost of conducting soil bearing capacity test shall be borne by the bidder. The lump sum rates should also include the cost of all materials like cement, steel, fine aggregate, coarse aggregate, scaffolding, shuttering, labour etc. whatsoever, providing and installing inlet, outlet scour and over flow double flanged D.I. pipe as per (IS 8329 with latest amendments), including cost of D.I. specials like Double flanged Expansion joints Bell mouth and flanged puddle collars, duck foot bends, D.I. Double sluice valves one each with inlet, outlet and scour pipes along with construction of suitable size Haudis. The lump sum rates shall also include lightning conductor, aluminum and steel ladder GI Railings, nuts & Bolts and all others specials and accessories whatsoever, complete in all respects to the entire satisfaction of the Engineer-in-charge.
Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with the prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. For more than 3 mtr. Street width Complete in all respect. (Mechanically ) (10kgf/ cm2) Pressure
Ref. CSR item 28.13 (iv)+ 28.1 (a) + 28.18
90 mm o/d PVC Pipe 10kg/cm2
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete.(with the approval of Engineer - in – charge)
(CSR item No. 28.27 A(a)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department size 0.90m x 0.90m
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mannual Earth work).
PVC pipe 63mm o/d 6kg/cm2
PVC pipe 90mm o/d 6kg/cm2
PVC pipe 110mm o/d 6kg/cm2
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mech. Earth work).
PVC pipe 63mm o/d 6kg/cm2
PVC pipe 90mm o/d 6kg/cm2
PVC pipe 110mm o/d 6kg/cm2
Providing, Stringing out, cutting, Jointing andtesting of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring.
D.I. Pipe as per IS 8329 DI-K7
100mm i/d pipe lines laid complete
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous course 50 to 75mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects. Note:-Contractor shall quote rates only for dismentling of matelled road and back filling with excavated earth , fully compacted. the restoration of the metalled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/ Panchayati Raj.
PVC pipe 63mm o/d
PVC pipe 90mm o/d
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
80 mm I/d sluice valve flanged
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete 9 No. with Each 3kg I.e (3 x 3 = 9kg)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 3No. With each of Size 0.6m x 0.6m
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVCclamp complete. Providing, fixing and jointing water meter.
Prov. & Fixing Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
Construction of brick masonry pump chamber of size 2.20 x 2.20 mtr. under the OHSR with toilet complete in all respect as per W/S & Sanitation Deptt. standard design & drawings including cost of material such as bricks, cement, Bajri & TMT steel, internal wiring etc. complete at Water Works site.
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of 5.00 BHP capable of delivering 157 LPM against a head of 52 mtr along with electric panel board consisting of electrical appliances such as automatic D.O.L. starter, Main Switch,VM,AMpere Meter,ELCB,Shunt capacitor.Single phase,preventer,Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class size 50mm and Length 29 mtr.(in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 80 Mtr. Length and 2.50mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
Providing and installing 80mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 1 & Drawings D-12 & D-17.
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 complete in all respects
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7.
Providing & fixing MS Sign Board as per standard size of DWSS
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
Operation & Maintenance of Water Supply Scheme after its completion and commissioning under the supervision of the DWSS/GPWSC during the O&M period of 3 months. , bidder shall: (i) Salary pay to staff (Pump Operator-cum-Chowkidar) for operate and maintain of WS Scheme; and (ii) Pay the power consumption charges during the O&M period (1/4th on direct electricity and 3/4th on solar system)
Planting ground covers (ordinary) includingdigging of beds to 15 cm depth and mixingFYM, fertilizer and nsecticides, planting of sapling at 25cm distance from plant to plant and row to row.
Planting ground covers (special) includingdigging of beds to 15 cm depth and mixingFYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.
Supplying and planting permanent trees in prepared pits and watering
Provision for one way stand post with khura complete in all respects.
JASBIR SINGH GOVT CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .