Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC 10 A FRIENDS COLONY PATIALA 147001 | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC L-1 Bidder |
Tender Value
₹15.1 L
EMD Value
₹30,500
Closing Date
27 Jul 2021, 5:00 pmClosed
Executive Engineer
EE WSS DIVN. No. 1 Amritsar
Providing Improved access to water through Household Connection in existing Water Supply Scheme Adliwal Block Harsha Chhina Distt. Amritsar. UNDER JJM NABARD XXVI
2021_WSS_66864_1
Adiwal letter no. 3012 dated 10-06-2021
Open Tender
Civil Works
Item Wise
90 days
Amritsar
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
₹30,500
17 Dec 2021
14 Jun 2021
28 Jul 2021
14 Jun 2021
27 Jul 2021
14 Jun 2021
Amount
Cost of Repair of Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications.
Repair of Pump Chamber
12.5mm thick cement plaster 1:4
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
White washing 3 coats inside of pump chamber complete in all respects
Finishing wall with water soloble exterior paint cement based paint such as snowcem robbiacem etc. on old work in two coats to give even shade.
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point without fan box
Wiring light point
Wiring 6 Amp. Plug control comprising wall socket point.
Wiring 16/20 amp. power plug control point.
Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent
Providing and fixing of electric tube set of reputed make
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete.
C.I Double air valve (Size 40mm)
Hollock wood doors shutter windows including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position (panelled, glazed or glazed and panelled)
40mm thick Door
Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them)
REPAIR OF OHSR
Providing & Fixing Jali, Gauge 15cm width & lightning conductor of GI 7/10” SWG (10mm) dia. standard wire with lightning rod of 25mm. Dia 0.9 m. Long with earth electrode 25mm dia. 2.75mtrs. long GI pipe from ground level connecting 50mm dia 1.40 m long perforated GI pipe including fixing of clamps as per IS:2309-1969 Complete in all respects.
Providing & Fixing Aluminium Ladder Inside the tank shall be 60cm wide made from Aluminium section LS 974 size, 66.68x31.75x4mm, weight 1.27 kg/m with steps made out of Aluminium section H, SP 3024 size 35x16.70x1.60mm, weight 0.362kg/m to be fixed on side in the top dome and other side in the bottome dome
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Including cost of specials (such as Tees, bends, sockets, elbows etc.) painting with anti corrosive bitumastic paint, testing, cutting threading inside building/railing for staircase (OHSR) (15 mm i/d)
Repair of Sluice Valve Complete in all respects
150 mm i/d Sluice Valves flanged
Repair of Expansion joint(6") at 6th Brace including shuttering & Centering Complete in all respects
REPAIR OF WATER WORKS
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing.
PROVIDING AND FIXING ANGLE IRON PICKETS WITH ANGLE 40MM X 40MM X 6MM INCLUDING COST OF CONCRETE BLOCK AND PAINTING COMPLETE IN ALL RESPECTS
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing.
Painting & Printing of MS Sign board complete as per standard size of DWSS complete in all respects.
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3.
Providing & Fixing (Replacement) C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI
80 mm i/d Sluice Valves flanged
100 mm i/d Sluice Valves flanged
150 mm i/d Sluice Valves flanged
Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSS standard specifations.
Minor Repair & replacement of pipe associated with repair complete in all respects (90 mm pvc pipe)
Minor Repair & replacement of pipe associated with repair complete in all respects (110 mm pvc pipe)
Minor Repair & replacement of pipe associated with repair complete in all respects (160 mm pvc pipe)
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
Providing and fixing in position CI Bib Cock(tap)(15 mm i/d)as per IS:210 with stainless steel spindle of approved make and Fixng of Nozzle to contro flow of water(to the approval of Enginer-in-charge Complete in all respect
Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. . (Connection at Existing pipe line)
Providing, Laying , fixing & jointing of P.V.C. Pipes including specials as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications (Mechanically Excavation and Including specials) PVC Pipe 63 mm o/d pipe of 6 Kgf. / sqcm
P/F & Jointing and ISI Marked gun-metal peet valve (heavy pattern) as per IS-778 with hand wheels on G.I. Pipe lines laid in the ground or inside building including all carriage complete. 50mm Size
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. (a) 63mm
Dismantling and restoration of Cement Concrete Flooring comlete in all respects.
Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. . (Connection at New pipe line)
Carriage for Sand
Carriage for Bajri
Credit for Replacement of Old S.V. (-)
CONDITIONS :-
Item for which no rate or price has been entered in will not be paid for the Employer when execut6ed and shall be deemed covered by the other rates and prices in the Bill of Quantities.
Unit rates and prices shall be quated by the bidder in indian ruppees.
Where there is a discrepancy between the rate in figures and words, the rates in words will govern.
Where there is a discrepancy between the rate and the line total resulting from muluplying the unit rate by quantity the unit rate quoted shall govern.
Any item of work not included in the above contract schedule of rates and got done at the site of work; the same will be paid according to CSR-2010 subject to the premium or discount tendered by the contractor. In the case of non-schedule items, the decision of the Engineer-in-charge will be final and binding upon the contractor. In case any item which is a part of lump-sum rate is be deducted @CSR rates + Ceiling premium prevailing on the date of tender
The work will be carried out in accordance with PWD Book of specifications - 1963 edition with upto date amendments.
Approximate quantities are given in the contract schedule of rates and these can vary at the time of execution of the work. The payment will be made according to the actual work done by the contractor.
All amendments issued on the common schedule of rates 2010. up to the date of opening of tenders will be applicable on the contract schedule of rates.
Contractor should clearly quote his rates in figures & words. Conditional tender will be rejected.
All items and rates provided in the DNIT are subject to the footnotes give in CSR-2010
The Engineer-in-charge will have full powers to change the layout of the work covered in this contract if considered necessary.
No claim will be entertained form the contractor in case, any mistake in description rates or unit occurs in any item taken in this schedule while preparing this DNIT or on account of typing or comparison or over writing. The same will be rectified at any time as per common schedule of rates 2010 along with upto date amendments.
The arrangements of bricks at site of work would be done by the contractor at his own level from his own source.
For any other non-schedule items, the contractor will submit through Engineer-in-charge, the analysis of rates in triplicate based on purchased vouchers. A margin of 10% shall be allowed for material components and 21.5% on labour components and contractor shall produce photo stat copies of the purchase vouchers in support of his claim. The decision of the Engineer-in-charge/Competent authority in the matter shall be final and binding on the contractor.
All the extra items will be got approved from the competent authority and no premium will be allowed on non schedule item
Pavement for the carriage of material shall be paid as per the rates quoted by the tenderer.
Time period allowed for completion of work in 3 months.
If contractor allowed for completion of work within 7 days from the date of allotment, DWSS reserve the right to impose penalty or withdraw the work and propose action for debarring in future tendering or both; decision of Chief Engineer (North) shall be binding.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .