Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1 BAMANAI LUHETA HATHRAS HATHRAS UTTAR PRADESH 204101 | HATHRAS | UTTAR PRADESH | 204101 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 01 NAUJARPUR BASAI KAJI SASNI HATHRAS UTTAR PRADESH 202150 | ALIGARH | UTTAR PRADESH | 202150 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
4 Sept 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
se edc hathras
se edc hathras
Work
2024_DVVNL_949412_1
EDCH-10/2024-25
Open Tender
Electrical Works
Item Rate
120 days
se edc hathras
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
DVVNL
₹42,000
9 Oct 2024
25 Aug 2024
4 Sept 2024
25 Aug 2024
4 Sept 2024
25 Aug 2024
Amount
Supply of Following Matarial as per relevent ISS
Stone Pad
Suspension Clamp With Nut & Bolt
Distribution Box with clamp
Dead end Clamp With Nut & Bolt
Copper L-piece
Danger Board
Holding Clamp With Nut & Bolt
Barbed Wire
Aluminium Lug
Pearcing Connector
X-Arm Clamp with Nut & Bolt
F Bracket
Earthing Set Complete
Transformer bus complete with structure
4x2.5 sqmm control cable
2x2.5 sqmm control cable
90 lbs rail pieces
Safe Carriage of following material from Electricty store center Hts to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.)
STP Pole 11 Mtr. Long
PCC Pole 8.5 Mtr. Long
Stay Set Complete
11 KV Pin Insulator with Pin
11 KV X-arm
ACSR weasel Conductor
3x185 Sqmm 11 kv XLPE Cable
3x300 sqmm 11 kv XLPE Cable
3x120 sqmm 11 kv XLPE Cable
LT AB Cable
LT PVC Cable
11 KV Fuse Set
11 KV TPMO
11 KV Disc Insulator with Fitting
Top Channel
Dropper Channel
250 KVA 11/0.4 KV T/F
11 kv Cable Jointing Kit
33 KV Bus Isolator
33 KV Post Insulator
33 KV Lightening arrestor
33 KV/ VCB with Double T/F control pannel and CT 200/100/1A
11 KV VCB Incoming
11 KV VCB Outgoing
Bus Coupler
Errection of following Poles with grouting including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
STP Pole 11 Mtr. Long
PCC Pole 8.5 Mtr. Long
Fixing/ Errection of following item, cost of labor, material and T&P which required for completion of work
Stone Pad
X-Arm Clamp
F Bracket
11 KV Pin Insulator with Pin
11 KV X-arm
11 kv Cable Jointing Kit
33 KV Bus Isolator With Structure
33 KV Post Insulator With Structure
33 KV Lightening arrestor With Structure
33 KV/ VCB with Double T/F control pannel and CT 200/100/1A With Structure
11 KV VCB Incoming
11 KV VCB Outgoing
Bus Coupler
90 lbs rail pieces
Suspension Clamp
Distribution Box
Dead end Clamp
Copper L-piece
Danger Board
Holding Clamp
Barbed Wire
Aluminium Lug
Pearcing Connector
11 KV Fuse Set
11 KV TPMO
11 KV Disc Insulator with Fitting
Top Channel
Dropper Channel
Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer.
Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
ACSR weasel Conductor
3x185 Sqmm 11 kv XLPE Cable
3x300 sqmm 11 kv XLPE Cable
3x120 Sqmm 11 kv XLPE Cable
LT AB Cable
LT PVC Cable
4x2.5 sqmm control cable
2x2.5 sqmm control cable
Underground Laying of 11 KV XLPE Cable as per RESPO manual and as per direction of supervising engineer.
Underground Laying of 11 kv XLPE cable including cost of bricks and sand as per RESPO manual and as per direction of supervising engineer.
Safe Dismenteling of old 5 MVA T/F from Foundation with opening of all HT Jumpers, opening of radiators, draining of oil all works which required for dismentling of power T/F and carriage it from switch yard to out side boundary all cost of labour and T&P which required for completion of work
Construction of Plinth and foundation of Power T/F above ground level 0.4 Mtr & below the ground level of 0.5 Mtr After Exavation of 4 "earth brick ballast shall be provided and remaining will be done properly After ballast shall be provided a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
Earthing of power T/F
Road Restoration XLPE Cable
Installation of following T/F on Old/New constructed double pole in proper alignment direction & making HT/LT connection.
250 KVA 11/0.4 KV T/F
Construction of plinth of size 2*2*1.5 mtr above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and rammering will be done properly After ballast shall be provided and rammering will be done properly After that a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
Pipe earthing of 250 KVA medium Power Transformers
Net Fencing of Medium Power Transformer
Safe Dismenteling of old and used following T/F from Double Pole with opening of all HT/LT Jumpers, all works which required for dismentling of T/F and carriage it up to Store Hathras/ J.E Store all cost of labour and T&P which required for completion of work
100 KVA 11/0.4 KV T/F
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer
Resagging of Existing line by stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
ACSR Weasal/Dog conductor
Fabrication and erection of neutral earthing L Type support with structure.
Fabrication and erection of Cable support with structure.
Plinth & Foundation for VCB
Making of 11 KV cable boxes mounted with Switchgears and transformers (kit)
Painting of indoor equipments
sundries
Back Cartage of Following Matarial
PVC Cable
ACSR Conductor SCRAP
Bobby Electricals
P K ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .