| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC L-1 | |
| 2 | L2₹27.1 L+₹11,030 (0.41%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹27.9 L+₹86,819.50 (3.22%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹32.8 L+₹5.8 L (21.6%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹33.0 L+₹6.0 L (22.1%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L5 | Rejected-Finance L5 |
Tender Value
₹47.2 L
Closing Date
8 Jul 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
SPECIAL REPAIR TO CONFERENCE HALL OF ADVENTURE CELL AT NARAINA HILL TOP UNDER AOR OF GE (AF) FARIDABAD
2024_MES_659314_1
GE (FBD)/AF-11/2024-2025
Open Tender
Civil Works
Item Rate
180 days
NARAINA
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
5 Dec 2024
12 Jun 2024
10 Jul 2024
12 Jun 2024
8 Jul 2024
26 Jun 2024
12 Jun 2024 - 19 Jun 2024
Amount
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engineer-in-Charge. (Payment for providing grooves shall be made separately).
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engineer-in-Charge.
Supply only liquid WPC complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plastered surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface on walls/ceiling, roof boarder, drops, fins, chajja / roof facia, column surface obtain smooth finish using sand paper and applying two coats of exterior emulsion paint over a coat of acrylic primer as per manufacturers instruction complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge.
M& L for Glazed ceramic jointless light/coloured group of size 300/350mmx450/600mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by GE
M&L for vitrified tiles light shade /dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm , in floors, dado , skirting etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
Taking down existing roof treatment of any description and any type complete all as specified and directed by Engineer-in-Charge.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, incl Brushing neat cement slurry with 3.0kg of cement per sq. metre etc complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish even and smooth (w/o using extra cement) excluding WPC as per user manual at any height etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) nominal mix, type B-0, using 12.5mm graded stone aggregate in roof padding and surface finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for Making benching with PCC (1:2:4) type B0 using 12.5mm graded stone aggregate mixed with WPC along side wall adjoining to roof in concave shape complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete tiles of size 25 cm x 25 cm x 22 mm thick, machine pressed, set, jointed and pointed in neat cement slurry with grey cement and no pigment in roofs, floors over and including screed bed or bedding layer of cement mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge. Note : It is normal PCC Tile and used for Accessible roof surface.
Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters not exc. 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters exc 1.5 Sqm but not exc. 4 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
M&L for factory made extruded WPC (Wood polymer composite) solid door/window/ceosetory windows & other Frames/chowkhat of size 45mm X 85mm Rebate comprising of virgin PVC polymer of K Value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750kg/cum screw withdrawal strength of 2200N (face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, wate/moisture proof and fore retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engr-in-charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note : For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
M&L for factory made extruded WPC (Wood polymer composite) solid door/window/ceosetory windows & other Frames/chowkhat of size 65x100mm Rebate comprising of virgin PVC polymer of K Value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750kg/cum screw withdrawal strength of 2200N (face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, wate/moisture proof and fore retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engr-in-charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note : For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F in repair for factory made 30mm Thick MOLDED WPC with decorative surface 2m thk Moulded wood grain printed Prelam PVC sheet on front face and 2mm thk PVC sheet on back side, 100 % Solid door ( Conforming As Per IS : 4020 ) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood Grain Texture and back side palin with density not less than 600 kg/cum. Manufactured by an ISO: 9001-2015 certified company. The door should be Water Proof , Termite Proof , Fire Retardent and having screw holding capasity.Fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screwsi ncl Aluminum Jali and Stainless wiremess and other assories as per required. Material test certificate and authentication should be compulsory provided by the manufacturing company, complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium framed work for door, window / vent (powder coated) aluminium with one or more rebated incl jointed cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium powder coated door shutter , aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm th sheet glass ordinary quality / frosted glass or ACP sheet incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts,1xdoor stoper,1xHydralic door closer with each shutter any type incl taking down complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium powder coated window and ventilator shutters, aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm th sheet glass ordinary quality glass/ frosted incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium Anodized powder coated fixed frame of partiton or fixed window / ventilator , aluminium section weighting not less than 0.55kg/RM excl 4.8mm thick sheet glass oridinary quality ' frosted glass or ACP sheet joining with rubber beading , aluminium snap beading complete all as specified and directed by Engineer-in-Charge.
S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed by Engineer-in-Charge.
M&L for 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S & F for 10 -12 mm thick glass door, frosted with certain logo, fixed with floor spring, fixed on floor with two nos stainless steel handle of 300mm on each leaf and fixed partition arrangement incl necessary provision to lock the door complete all as specified and directed by Engineer-in-Charge.
S&F double action floor spring hydrolically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed by Engineer-in-Charge.
S & F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F of door closer hydraulically regulated design No 3, universal type, suitable for door shutters of 851 to 1000m in width and weifht between 61 to 80 kg etc complete all as specified and directed by Engineer-in-Charge.
S&F of Mortice lock brass vertical type 4 lever etc complete all as specified and directed by Engineer-in-Charge.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface Surfaces plain or moulded, n exc 10cm width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed by Engineer-in-Charge.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed by Engineer-in-Charge.
M&L in repair of one piece closet with bowl for coupled WC with PP soft seat cover , hinges fixing accessories and accessories set of size 360x640x680 mm, strap 220 mm withsyphonic flushing cistern with necessary fittings complete all as specified and directed by Engineer-in-Charge.
S&F in repair wash hand basin table top of size 600x400x175 mm vitrous China including , waste coupling & PVC waste pipe of 32 mm dia etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-Charge.
S & F in repair Bib tap Chromium plated fancy type long body 15 mm bore with crutch or butterfly handle screwed down screwed to iron pipe complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F in repair Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed by Engineer-in-Charge.
S&F for CP brass Centre hole mixer without pop up waste system with 450 mm long braided hoses, 20mm cartridge size for mixing hot and cold water screwed down for iron pipe for WHB, in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repair for CP telephonic jet with all fitting and fixture for EWCs with 8 mm Dia 1.2mt length long flexible tube of Make- Jaquar or equvelent complete all as specified and directed by Engineer-in-Charge.
S&F for 5 mm thick looking mirror with magnetic looking arrangements fixed with and including chromium plated brass screws and PVC rawl plugs complete all as specified and directed by Engineer-in-Charge.
S & F for vitreousChina ceramic urinals sensor based automatic flush wall mounted (size-485x300x740) mm including all necessary fittings etc complete all as specified and directed by Engineer-in-Charge.
S & F for 8 mm thick toughened frosted glass urinal partitions modular typerectangular/chamfer shape (900x450)mm including all necessary stainless steel fitting using 304 heavy “L” Bracket with insert etc complete all as specified and directed by Engineer-in-Charge.
S&F for Soap tray brass chromium plated and fixed to plugs on wall with brass screws, complete all as specified and directed by Engineer-in-Charge.
S&F for Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed by Engineer-in-Charge.
S&F for Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified and directed by Engineer-in-Charge.
S&F for PVC connections 45/60cm long superior quality with PTMT nut on both side complete all as specified and directed by Engineer-in-Charge.
S&F in repair grating round 100 mm size of CP complete all as specified and directed by Engineer-in-Charge.
S & F in repair for CP towel racks with lower hanger complete all as specified and directed by Engineer-in-Charge.
S&F for tripple layered rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed repair in position including 20 mm dia float valve with aluminium fitting, dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F for tripple layered rotational molded polyethylene water storage tanks 3 layered, ISI marked (cylindrical vertical with threaded lid) hoisted and fixed in position all as specified in SSR Part-I of Capacity 500 litres with GI Tank Nipple inlet and outlet 20mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 20mm dia Nipple suitable for HDPE water tank.(Minimum weight 20mm 45gms) complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm dia Unions brass to connect iron to polyethylene and fixed complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel pegset of six suitable size of length etc complete all as specified and directed by Engineer-in-Charge.
S&F ventian blind for window including necessary items required for fix to wall complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed by Engineer-in-Charge.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10cm girht but not exc 20 cm girth complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints,laid in trenches or in floors etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S& F for 75 Cast Iron Cowl complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
M&L in repair for Soul wood WPC Exterior wall panelling size (2900x219x26) mm any colour/design approved by Engr-in-charge, inclusive of fixing on to wall incl L Corner, moulding end caps and necessary frame work for fixed and screws as required at site complete all as specified and directed by Engineer-in-Charge.
S&F Acrylic letters (English/Hindi) 300 mm high, 50 mm width and 3 mm depth hollow wall fixed on surfaces incl 3mm ACP sheets board of any description using stainless steel screws of suitable size or best quality adhesive including LED module rain proof lights fittings in each letters complete all as specified and as directedby Engineer-in-Charge. Note : The rate of ACP Sheet will not be paid separately.
Dismantling wall ceiling and boards, (fibere pulp, insulation etc.0 or insulation boards abdy thickness including cover fitllets complete all as specified and directed by Engineer-in-Charge.
M&L for PVC hollow panelling 5 to 8 mm thick on ceilling with necessary frame work in Design POPUP pattern and any colour approved by engr-in-charge, inclusive of fixing on to ceiling incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed by Engineer-in-Charge.
M&L in repair for PVC hollow wall panelling 5 to 8mm thick any colour/design approved by Engr-in-Charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bars, barred iron doors, ladders, frame work of watertanks and and similar works incl necessary welding confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone agg. ) as in plinth protection / path/ any paved area and finish the surface fair & even, laid in panels complete all as specified and directed by Engineer -in-Charge.
M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any colour as approved by GE complete all as specified and directed by Engineer-in-Charge.
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazing approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directedby Engineer-in-Charge. (Note : Glazed Tile are required.)
M & L for treating the soil under floor/wall at the rate of 5 litres of emulsion per Sqm of surface area, (with 20% EC) complete all as specified and directed by Engr-in-charge.
Removing/getting out of excavated material/spoils/debbries dumped at site to a distance exceeding 500 m but n exc 1.5 km and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed by Engineer-in-Charge.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators complete all as specified and directed by Engineer-in-Charge. Note-After rewiring cutting chasing portion should be matched with existing finishes of walls..
All as per item No 102 above but 5 Amp socket outlet, independent.
All as per item No 102 above but on the same board.
All as per item No 102 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable.
All as per item No 102 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly.
S&F modular white cover plate with frame, 1 module complete all as specified and directed by Engineer-in-Charge.
S&F modular white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge.
S&F modular white cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge.
S&F modular white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge.
S&F Metal Flush boxes 1/2 module complete all as specified and directed by Engineer-in-Charge.
S&F Metal Flush boxes 3 module complete all as specified and directed by Engineer-in-Charge.
S&F Metal Flush boxes 6 module complete all as specified and directed by Engineer-in-Charge.
S&F Metal Flush boxes 8 module complete all as specified and directed by Engineer-in-Charge.
M&L modular switch 1 way 6 A, 1 module complete all as specified and directed by Engineer-in-Charge.
M&L modular bell push switch, 6 A, 1 module complete all as specified and directed by Engineer-in-Charge.
M&L modular socket, 6A-2/3 pin combined, 2 module complete all as specified and directed by Engineer-in-Charge.
M&L modular Switch 16A, 6 pin, 3 module complete all as specified and directed by Engineer-in-Charge.
M&L modular Socket 16A, 6 pin, 3 module complete all as specified and directed by Engineer-in-Charge.
S&F modular fan step regulator, 120W -2 module complete all as specified and directed by Engineer-in-Charge.
S&F bell Multi music AC 230Volts single pole complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose,3 phase/PVC/Polycarbonate,isolated body after dismantling old one complete all as specified and directed by Engineer-in-Charge.
M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed by Engineer-in-Charge.
Supply and install in replacement SPN enclosure including plug And socket with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan sweep 250 mm in replacement made up of sturdy engineering plastic complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Taking down existing split AC and re-installation with gas charging,cleaning and minor repair complete all as specified and directed by Engineer-in-Charge.
M & L for Taking out unserviceable indoor unit and supply and fix the new indoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper condensor coil and evaporator coil for split AC 1.5 TR complete all as specified and directed by Engineer-in-Charge.
M&L for Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and Fix new inverter type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge.
S&Fix in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB SP 6 t0 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB SPN 32 Amps 230 Volts complete all as specified and directed by Engineer-in-Charge.
Taking down Old UNSV ceiling fan of any capcity from the installed area with all nuts/washers and downroad/canopy etc safely deposit to mes store complete all as specified and directed by Engineer-in-Charge.
Supply and fix BLDC fan Energy Efficicent ceiling fan Sweep size 1200mm with speed 350 RPM motor air delivery 220 CMM input power 28W-32W and having remote control complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supplying and fixing PVC conduit 20 MM dia medium grade (ISI) along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed by Engineer-in-Charge.
S&F LED flood light luminarie 30 W 5000 K with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge.
Supply and installation of PVC Duct For AC copper pipes and insulation complete all as specified and directed by Engineer-in-Charge.
S&F in replacement wall mounting box type LED tube light fitting , extruded aluminium heat sink provided for efficient heat dissipation & Integrated electronic driver 1x20 watt comprising of strong jointless CRCA body with all accessories complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacement copper tubing 15mm outer dia complete all as specified and directed by Engineer-in-Charge.
RRR CONSTRUCTIONS
SAGAR ENTERPRISES
Shiv Shakti Builders
M/S Rohit Enterprises
Singh Associates
M/S BHARAT BUILDERS
M/S Yamin
ETERNITY PROJECT
imran construction company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .