Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹21.0 L+₹2.0 L (10.3%)Rejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | L3₹22.0 L+₹3.0 L (15.5%)Rejected-Finance NO 3 JANI JAN KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-Finance Not being the lowest tenderer | |
| 4 | L4₹22.7 L+₹3.7 L (19.4%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L4 | Rejected-Finance Not being the lowest tenderer | |
| 5 | L5₹23.4 L+₹4.3 L (22.8%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L5 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER, GE CHENNAI
GARRISON ENGINEER, FORT ST GEORGE CHENNAI
REPAIR/ MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY AND ITS ALLIED WORKS AT ZONE A B AND D AREA UNDER GE CHENNAI
2020_MES_364166_1
8440/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Chennai
As per tender document
7 documents required · 7 mandatory
₹500
GE Chennai
₹70,000
Yes
12 Oct 2020
25 Jul 2020
28 Aug 2020
25 Jul 2020
24 Aug 2020
3 Aug 2020
60 days
Amount
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for taking out/ laying cables, CI/ GI/ DI/ HDPE pipe line and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, laying/ spreading in trenches clean dry sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and directed. Note: Punned thickness only will be considered or payment.
Supply and laying burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and directed.
Laying only old size burnt bricks, laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and as directed. Note: Old re-useable bricks obtained during taking out of cable shall be re-used.
Taking out existing PVC/ XLPE cable 1100 volts grade LT cable of size 6 sqmm 2 core with glands, bricks/ cable protection pipe, cable route indicators etc. from the trench/ fixed along wall or passing through pipes/ in floor, removing the unserviceable/ faulty cable and stacking serviceable cable for re-use complete all as specified and directed. Note: Excavation and earthwork will be measured and paid separately under appropriate items.
All as per item No. 7.00 above but cable size 10 sqmm 2 core.
All as per item No. 7.00 above but cable size 16 sqmm 4 core.
All as per item No. 7.00 above but cable of size 25 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 240 sqmm 3½ core.
Laying only old serviceable cable of size 25 sqmm 3½ core including jointing, testing and commissioning complete all as specified and directed. Note: Old serviceable cable as obtained from taking down shall be re-used after testing as directed by Engineer-in-Charge.
All as per item No. 17.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 17.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 17.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 17.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 17.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 17.00 above but cable of size 240 sqmm 3½ core.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and directed.
All as per item No. 24.00 above but cable size 10 sqmm 2 core.
All as per item No. 24.00 above but cable size 16 sqmm 4 core.
All as per item No. 24.00 above but cable of size 25 sqmm 3½ core.
All as per item No. 24.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 24.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 24.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 24.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 24.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 24.00 above but cable of size 240 sqmm 3½ core.
M&L cable jointing kit for 1100 volts grade cable for straight through heat shrink type joints complete with jointing material and accessories suitable for 25 sqmm 3½ core XLPE armoured aluminium conductor cable complete all as specified and directed.
All as per item No. 34.00 above but for 35 sqmm 3½ core cable.
All as per item No. 34.00 above but for 50 sqmm 3½ core cable.
All as per item No. 34.00 above but for 95 sqmm 3½ core cable.
All as per item No. 34.00 above but for 150 sqmm 3½ core cable.
All as per item No. 34.00 above but for 185 sqmm 3½ core cable.
All as per item No. 34.00 above but for 240 sqmm 3½ core cable.
Supply and laying GI tube light grade 50mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 80mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 100mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
M&L for taking down the transformer 315/ 400 KVA from existing position with the help of chain pulley and proper arrangement after disconnecting the connections, taking out core, draining out the old transformer oil and carrying out visual inspection including disconnected core winding, bus chamber and insulation of winding, cleaning, meggering for insulation test, carrying the transformer to the workshop for repairing, varnishing the winding, heat testing and bracing the winding terminal properly, bringing back the transformer to site and re-fixing the same in existing location including making electric connections complete all as specified and directed. Note: Filteration of transformer oil will be measured and paid separately.
M&L for filteration of transformer oil using steam line type machine at site to achieve BDV not less than 40KV at the gap of 2.5mm for 1 minute as specificied and directed.
M&L for taking down the transformer 120/ 160 KVA from existing position with the help of chain pulley and proper arrangement after disconnecting the connections, taking out core, draining out the old transformer oil and carrying out visual inspection including disconnected core winding, bus chamber and insulation of winding, cleaning, meggering for insulation test, carrying the transformer to the workshop for repairing, varnishing the winding, heat testing and bracing the winding terminal properly, bringing back the transformer to site and re-fixing the same in existing location including making electric connections complete all as specified and directed. Note: Filteration of transformer oil will be measured and paid separately.
Supply and pouring of tested transformer oil for topping up of transformer all as specified and directed.
Supply and filling silica gel including taking out old silica gel complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 125 Amps, 415 volts breaking capacity, 16kA with adjustable thermal setting conforming to IS: 13947-II including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 160 Amps, 415 volts breaking capacity, 16kA with adjustable thermal setting conforming to IS: 13947-II including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 200 Amps, 415 volts breaking capacity, 36kA with adjustable thermal magnetic range conforming to IS: 13947-II including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 250 Amps, 415 volts breaking capacity, 36kA with adjustable thermal magnetic range conforming to IS: 13947-II including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 400 Amps, 415 volts breaking capacity, 50kA with adjustable thermal magnetic range conforming to IS: 13947-II including taking down the existing one complete all as specified and directed.
M&L for painting of 315/ 400 KVA transformer indoor type with two coats of synthetic enamel grey colour paint after throughly scrapping/ cleaning the rushed portion and cleaning other surface complete all as specified and directed.
M&L for painting of 160/ 260 KVA transformer indoor type with two coats of synthetic enamel grey colour paint after throughly scrapping/cleaning the rushed portion and cleaning other surface complete all as specified and directed.
S&F ON-LOAD change over switch in sheet steel enclosure change over switch 4 pole, compact design type 415V AC, 50 Hz, 200 Amps, 4 pole conforming to IS 13947-3 including taking down the old change over switch complete all as specified and directed.
S&F ON-LOAD change over switch in sheet steel enclosure change over switch 4 pole, compact design type 415V AC, 50 Hz, 100 Amps, 4 pole conforming to IS 13947-3 including taking down the old change over switch complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to ganvanised iron strip of size 32 x 6mm as earth lead by means of bolts, nuts and washers of galvanised iron, protected by means of 40mm dia light grade GI pipe all as specified and shown in MES schedule electrical plate No -3 of SSR Part-I including necessary excavation and earth work in soft/ loose soil, PCC (1:3:6) type C-1 in chamber, 50mm thick RCC (1:2:4) type B-1 cover slab with 8mm dia MS bars at 100mm centre to centre both ways and MS 6mm dia hook, charcoal dust, salt, funnel for watering complete and testing the earth resistance and writing on the chamber by paint including demolition of existing earthing complete all as specified and as directed.
M&L for opening LT, 1100V, ACB front and back side complete after taking shutdown, cleaning, dusting inside & outside of ACB, greasing, oiling the mechanical parts of ACB and complete servicing including the following:- (a) Replacement of tripping coil 440V. (b) Replacement of contacts. (c) Replacement of wiring for tripping coil. (d) Replacement of indicating lamps. (e) Replacement of internal wiring for indicating lamps.
M&L for opening HT, 11KV, VCB front and back side complete after taking shutdown, cleaning the dusting inside & outside of VCB, greasing, oiling the mechanical parts of VCB and complete servicing including the following :- (a) Replacement of indicating lamps. (b) Replacement of internal wiring for indicating lamps. (c) Replacement of wiring for tripping coil (No volt coil), tripping switch set. (d) Replacement of No Volt coil of suitable capacity. (e) Complete servicing and testing of earth fault relay, over load relay, digital voltmeter, digital ammeter and all the protective equipment inside the VCB to be serviced and made working properly with replacement of defective equipments complete all as specified and directed by Engineer-in-Charge.
M&L for prepairing old painted steel surface (LT panel of any size and type) of any description over 10cm width or girth and applying two coats of synthetic enamel grey colour paint after throughly burning the existing paint including repairing the LT panel door by tack welding as required complete all as specified and directed.
Supply and spreading 40mm to 80mm graded stone aggreate in the sub station installation area all as specified and directed by the Engineer-in-Charge.
Supply and replacement of synthetic insulating rubber mat of size 2m x 1m x 2mm ISI marked in E/M installations all as specified and directed.
M&L for opening of HT 11KV compact substation consisting of HT breaker, LT breaker, 120/ 160 KVA transformer front and back side complete after taking shutdown, cleaning the dusting inside & outside of HT/ LT breaker and decarbonising the contact and greasing/ oiling the mechanical parts including the following:- (a) Replacement of indicating lamps. (b) Replacement of internal wiring for indicating lamps. (c) Replacement of wiring for tripping coil (No volt coil), tripping switch set. (d) Replacement of No Volt coil. (e) Complete servicing and testing of earth fault relay, over load relay, digital voltmeter, digital ammeter, indication lamps and all the protective equipment inside the compact substation to be serviced and made working properly with necessary replacement of defective equipments complete all as specified and directed by Engineer-in-Charge. (f) Cleaning systhetic rubber boot if damaged change the boot.
Supply and fix in replacement switch fuse unit rewireable type in sheet metal enclosure with fuse carrier of TPN 32A, 415V all as specified and directed.
Supply and fix in replacement switch fuse unit rewireable type in sheet metal enclosure with fuse carrier of TPN 100A, 415V all as specified and directed.
Supply and fix in replacement switch fuse unit rewireable type in sheet metal enclosure with fuse carrier of TPN 63A, 415V all as specified and directed.
M&L for providing cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate in any location complete all as specified and directed.
M&L for brick work built in cement mortar (1:6) using old size fly ash bricks straight or curved on plan exceeding 6 metre mean radius complete all as specified and as directed.
M&L for rendering 15mm thick in two coats i.e. 1st coat 10mm thick in cement mortar (1:6) and 5mm thick finishing coat in cement mortar (1:4) and finishing the surface even and smooth without using extra cement complete all as specified and directed.
S&F in replacement air break switch (GOD), 11KV triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps complete all as specified and directed.
S&F in replacement outdoor air break (switch) insulator for 11000 volts suitable for 200 Amp current rating complete all as specified and directed.
S&F in replacement 11KV lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
S&F in replacement junction box made out of one piece mould SMC base SMC door with hinged cover suitable for and including provn of 10mm thick hylum sheet connector block for incomming and out going cable for connecting with bolts and nuts including provn of one cut out 16 amps with neutral link for street light fixed on steel/ RCC poles with suitable clamps made out 15mm x 6mm flat iron including bolts, nuts and washers etc. complete as specified and directed.
M&L bracket fabricated out of 40mm dia GI light grade pipe 2 metre long bent to shape as directed and fixing to pole with brackets of suitable size complete all as specified and directed.
M&L painting to LT steel tubular poles 8.5/ 9Mtr long including all fittings and fixtures complete, fixed with poles with one coat of aluminium paint after scrapping of rust and preparation of surfaces complete all as specified and directed.
S&F in replacement electronic driver assembly for LED street light fitting of 40/ 50watt all as specified and directed.
M&L for writing letters and figures in white enamel in black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats and white circular border over steel/RCC surfaces of electric poles complete all as specified and directed.
S&F LED street light luminaire outdoor type 48 watts new generation energy saving and environment friendly long life versatile pressure die cast aluminium IP66 roadway luminaire with high power LEDs as high light source and electronic driver suitable for operation on AC single phase 220-240 volts, 50 Hz supply, including provision of two single core 4 sqmm copper conductor PVC insulated, 1100 volts cable not less than 8 metre long and making connection from junction box of pole including taking down old fitting complete all as specified and directed. Make: Havells Cat Part No. INDURAPEARLLEOSL48WLED 787SASYTOPC 9405 or equivalent of other specified makes.
S&F LED street light luminaire outdoor type 20 watts new generation energy saving and environment friendly long life versatile pressure die cast aluminium IP66 roadway luminaire with high power LEDs as high light source and electronic driver suitable for operation on AC single phase 220-240 volts, 50 Hz supply, including provision of two single core 4 sqmm copper conductor PVC insulated, 1100 volts cable not less than 8 metre long and making connection from junction box of pole including taking down old fitting complete all as specified and directed. Make: Havells Cat Part No. INDURAPEARLLEOSL20WLED 787SASYTOPC 9405 or equivalent of other specified makes.
Supply, install, test & commissioning LT panel outdoor, floor mounted/ pedestal type, cubical, self supported, CPRI approved make,front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, fabricated out of 3mm CRCA sheet duly powdercoated,mounted/ fixed on and including MS angle iron stand of 50cm height above ground, fabricated out of 50mm x 50mm x 6mm thick MS anglesduly painted with black enamel synthetic paintover a red oxide primer duly grouted in PCC (1:3:6) type C-2 using graded stone aggregate as in foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5sqmm, interconnection of suitable size/ capacity of copper strips for switch gear connection from main bus bar four run inculding earth bus strip of 300A capacity for entire length of panel, suitable size of MS glandwith gland plate and alluminium lugs/ thimbles for all incoming/ out going cables etc. complete and including taking down the old panel and accommodating the followings:
Supply, install, test & commissioning LT panel outdoor, floor mounted/ pedestal type, cubical, self supported, CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, fabricated out of 3mm CRCA sheet duly powdercoated,mounted/ fixed on and including MS angle iron stand of 50cm height above ground, fabricated out of 50mm x 50mm x 6 mm thick MS anglesduly painted with black enamel synthetic paintover a red oxide primer duly grouted in PCC (1:3:6) type C-2 using graded stone aggregate as in foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, interconnection of suitable size/ capacity of copper strips for switch gear connection from main bus bar four run inculding earth bus strip of 200A capacity for entire length of panel, suitable size of MS glandwith gland plate and alluminium lugs/ thimbles for all incoming/ out going cables etc.complete including taking down the old panel and accommodating the followings:
Banyan Engineers and Contractors
SRI LAKSHMI ASSOCIATES
RK ENTERPRISES
PSK Enterprises
EVEREST ENGINEERING WORKS
diesel power services (a.p)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .