| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.9 LAccepted-AOC | 1 | Accepted-AOC Lowest tender | |
| 2 | 2₹32.6 L+₹79,756 (2.51%)Rejected-AOC A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | 2 | Rejected-AOC 2nd | |
| 3 | 3₹33.6 L+₹1.8 L (5.73%)Rejected-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 3 | Rejected-AOC 3rd | |
| 4 | 4₹46.9 L+₹15.1 L (47.6%)Rejected-AOC 137 D6 ARAVALI HEIGHTS DPL DWARIKADISH ROAD DHARUHERA REWARI HARYANA 123106 | REWARI | HARYANA | 123106 | 4 | Rejected-AOC 4th |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
28 Nov 2022, 6:00 pmClosed
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
SPECIAL REPAIRS TO E/M, LT PANELS, UG CABLES AND CERTAIN OTHER RELATED WORKS, ADDN/ALTN/REPLACEMENT OF CERTAIN EARTHING PITS IN TECH AREA AT 12 BRD AND PROVN OF AIR CONDITIONER AT AF NET ROOM AT 12 BRD UNDER GE (AF) TUGHLAKABAD
2022_MES_553708_1
GE/TKD-45/2022-23
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹95,000
Yes
7 Mar 2023
31 Oct 2022
30 Nov 2022
7 Nov 2022
28 Nov 2022
14 Nov 2022
Amount
Special repair of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortar (1:3) where required all as required at site and directed by the Engineer-in-Charge at Tech area and Vayusena Vihar for Sewage tanks. Note: The rate quoted by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Cantonment Board/MCD (c) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
Special repairs of sludge holding tank of Sewage treatment plant and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortar (1:3) where required all as required at site and directed by the Engineer-in-Charge at Tech area and Vayusena Vihar for Sewage tanks. Note: The rate quoted by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Cantonment Board/MCD (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
Cleaning of Fab-1 and Fab-2 of Sewage treatment plant and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortar (1:3) where required all as required at site and directed by the Engineer-in-Charge at Tech area and Vayusena Vihar for Sewage tanks. Note: The rate quoted by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Cantonment Board/MCD (c) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
Cleaning of Tube settler of Sewage treatment plant and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortar (1:3) where required all as required at site and directed by the Engineer-in-Charge at Tech area and Vayusena Vihar for Sewage tanks. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the Delhi Cantonment Board/MCD (c) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge.
Cleaning of Treated water tank with chemical contact tank of STP by removing of all deposited sludge, scale or other unwanted materials from the tank by any means and removing the same away from site not less than 5 KM from the Cantt area and after cleaning, washing and scraping the wall with complete all as specified and directed by Engr-in-Charge.
Cleaning of filter medial tank (ACF & DMF), pumping out all sludge and foreign material including washing the entire tank and scraping the walls with wire brushes and making good the patches on walls internally or externally where required complete all as specified and directed by Engr-in-Charge.
Supply and pouring Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR complete all as specified and directed by Engr-in-Charge.
S&F in replacement of CI butterfly valve of following sizes, stainless steel disc, gear mountable as per IS 13095 class PN-1.0 complete with nuts, bolts, washer and rubber gasket including taking out old unserviceable butterfly valve complete all as specified and directed by Engr-in-Charge.
50 mm bore
80 mm bore
100 mm bore
M&L for DWPE chemical for sewage treatment plant complete all as specified and directed by Engr-in-Charge.
M&L for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge.
M&L for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge.
M&L for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge.
M&L for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge.
M&L for replacement of activated carbon IV 1000 complete all as specified and directed by Engr-in-charge.
Taking out complete pebbles from the filter and refilling the same pebbles after washing /cleaning thoroughly complete all as specified and directed by Engr-in-charge.
S&F in repairs of sluice valve flanged end drilled type with steel spindle including nuts, bolts and jointing material of class PN-1.6 ISI marked of size 100 mm bore complete all as specified and directed by Engr-in-charge. Make:- Kirloskar/Kartar/Zoloto
S&F in replacement of MS pipe ( Heavy duty Class 'c') including fitting as required of following sizes laid in trenches or laying oe floor for connecting to various STP accessories and to connect outgoing water main all as directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item
100 mm bore
80 mm bore
40 mm bore
Supply and mixing of Sodium hypo chloride having 10% chlorine content complete all as specified and directed by Engr-in-charge.
Supply and mixing of Poly aluminium chloride 100% purity complete all as specified and directed by Engr-in-charge.
Supply and mixing of poly Electrolyte 100% Purity complete all as specified and directed by Engr-in-charge.
Supply and mixing of Dewatering Poly Electrolyte 100 % Purity complete all as specified and directed by Engr-in-charge.
Overhauling of air compressor coupled with blower motor 5 HP capacity Installed at Sewage treatment plant including necessary arrangement to transporting to workshop for re-grinding of shaft, oiling, greasing etc and necessary replacement of wornout bolts, nuts, washers, silencer, belt drivers, pressure gauge, air-filter, bearing, shaft, rings etc. Re-assembling the compressor with blower motor, commissioning and testing to the entire satisfaction of Engineer-in-charge. Note :- Spare parts required for overhauling shall be measured and paid separately under relevant Item.
M&L in replacement of compressor oil complete all as specified and directed by Engr-in-charge.
Disconnecting the existing defective electric motor of any make 1 to 3 HP from electric mains by isolating the naked connections, removing from foundation by unscrewing the nuts, bolts etc, dis-couple from pump etc opening of motor for inspection in presence of Engr-in-Charge & carry out minor repairs at site re-assembling the motor after repair, re-fixing in position re-connecting same as prior to removing from foundation including replacement of nuts, bolts washers if necessitates of suitable size, testing and commissioning complete all as specified and directed by Engr-in-charge. Note:- (a) Replacement of defective parts shall be measured and paid separately as S&F here after. (b) In case of major repairs not possible at site, the motor shall be shifted to contractor’s wksp and cost of shifting to wksp and back to site included in the item rates.
Taking out old unserviceable/burnt copper winding of motors capacity 1 to 3HP (defective motor taken out in item No. 1above) and material and labour for rewinding of electric motor of capacity 1 to 3 HP , 3 Phase with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge, complete all as specified and directed by Engr-in-charge.
M&L for replacement of Ball bearing of the electric motor upto 1 HP 3 phase / single phase complete all as specified and directed by Engr-in-charge. Make: SKF/TATA/NBC.
M&L for replacement of MS Shaft of the electric motor upto 1 HP 440 Volts in repairs complete all as specified and directed by Engr-in-charge.
Taking out defective pump set of any type, any make (including Sewage Pumps or filter pump installed at STP) of capacity up to 1 to 3 HP by unscrewing the foundation bolts, disconnecting from water connection, and disconnecting from electric motor, opening for inspection in presence of Engr-in-Charge and carry out minor repair at site, in case major repair/replacement of parts not possible at site, the pump shall be shifted to contractor's workshop on his own cost, and re-fixing, re-connecting in position, testing and commissioning complete including replacement of nuts bolts washers complete all as specified and directed by Engr-in-charge. (single/3 phase upto 1 HP) Note:- Replacement of defective part by new one shall be measured and paid separately under respective items.
M&L for replacement of unserviceable/defective mild steel shaft upto 1 HP centrifugal pump set of any make complete all as specified and directed by Engr-in-charge.
All as per item No 29 above here in before but Gland packing, CI Check Nut, Gland Cover with Nut and Bolts complete all as specified and directed by Engr-in-charge.
All as per items No 29 above here in before but ball bearing including greasing etc. complete all as specified and directed by Engr-in-charge.
All as per items No 29 above here in before but impeller bronze/brass complete all as specified and directed by Engr-in-charge.
All as per items No 29 above here in before but neck ring complete all as specified and directed by Engr-in-charge.
Supply fixing, testing and commissioning in-replacement of decline dozing pump model No 96 NGQ 51 high pressure single head gear motored adjustable dosing pump with accessories including lead tubing , connecting nuts injection check valve , clay weight and ferrules with altoch dosing system model ADS -1 consisting of 40 ltr -100 ltr PE/FRP tank with PE/FRP lid and level gauges along with agitator with shaft and blade in plastic, mounted on tank complete all as specified and directed by Engr-in-charge. Make: Declibac / Chlorotech
Surface dressing in hard/dense soil, not exceeding 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area of installation/around the valve pit chamber/along the pipeline routes if required etc all as specified and directed by Engr-in-charge.
M&L for painting to exposed CI/GI/MS pipe lines of header/ suction/delivery of pumps any type/make/size including sluice valves, fittings and non return valves at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete all as specified and directed by Engr-in-charge.
M&L for painting to exposed Filter media tank (ACF and DMF) at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete all as specified and directed by Engr-in-charge.
M&L for submain/panel wiring with two single core 2.5 Sq mm PVC insulated FRLS multistrand PVC fitting conductor cable drawing into and including PVC casing and caping of suitable size ISI marked with all conduit fitting and S&F accessories and one single core 2.5 Sqmm FRLS multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engr-in-charge.
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead of size 100 mm bore dia complete all as specified and directed by Engr-in-charge.
Refixing old 100 mm bore dia CI/DI pipes in new or old position after cleaning thoroughly and removal of all blockages by using splitted bamboo/steel rod effectively of pipe including rubber titan/gasket joint etc. complete all as specified and directed by Engr-in-charge. Note : Excavation, lead joint, CI fitting etc shall be measured and paid separately.
Supply and fixing CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs 100mm bore complete all as specified and directed by Engr-in-charge.
M&L for run lead joints for CI pipe 100 mm bore dia including all jointing material required at site complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of valve pit cover made out of MS frame 40x40x6mm thick angle iron with and including 3mm thick MS top cover with locking arrangement and painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed by Engineer-in-charge.
M&L for Construction of valve pit chamber having internal dimension 120 cm x 120 cm x 120 cm (internal height) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick, 23 cm thick in CM (1:4), 10 mm thick rendering all around the brick work in cm (1:6) PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with locking arrangement with and including 50 mm pad lock with double key arrangement, MS frame made out of 40 x 40 x 6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismantling of existing valve chamber complete all as specified and directed by Engr-in-charge.
Excavation in trenches in soft/loose soil, n.exc 1.5 mtr wide and n.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning in trenches for protection of LT underground cable including watering and consolidation complete all as specified and directed by Engr-in-charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available of size 23x11.5x7.5 CM (+8% tolerance) in trenches for protection of underground cable complete all as specified and directed by Engr-in-Charge.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specified and directed by Engr-in-Charge.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr-in-Charge.
M&L complete for drilling hole under hard standing /road for laying of pipe for protection of cable etc by means of manual buckle and without disturbing the top surface and making good the disturbed surface if any complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of GI tube light grade 40 mm bore complete all as specified and directed by Engr-in-charge.
Supply and laying in replacement of GI tube light grade 80 mm bore complete all as specified and directed by Engr-in-charge.
Taking out old serviceable / unserviceable underground cable of any size from excavated trenches /pipes complete all as specified and directed by Engr-in-charge. Note: Earth work, segregating cable cover measured separately.
Supply and lay or fixing or passing in replacement through pipe cable XLPE (FRLS) with aluminium conductor with heavy duty stranded 1100 volts size of 35 Sqmm 4 Core. Note:- XLPE insulated PVC sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS-7098 (Part-I) for PVC insulated cables with following features (a) Cable shall have fire retarded low smoke (FRLS) compound added to it in the out sheathing as per IEC 754(part-I) IEC-60332 part-2 IFEE 383 ASTM 2x43 and ASTM 2X63 flame retardant compound (PR) as per EIC specification. (b) Inner sheathing shall be of extruded PVC. (c) Heat resisting PVC shall also be added to extrude inner and outer sheathing (d) Cable shall also be supplied with sequences hall marking at every meter as the outer sheathing. (e) Ultra violet radiation resistances compounded comprising ton ASTMG-53. (f) Anti rodent and ant termite compound added (g) PVC compounds of various grades as IS-5831 (h) compaction conductors shall be shaped and arrangement for the same with be on the cable. Note:- (i) Each cable shall be tested for all applicable routine tests as per IS-5831,IS-7098 BS-6746,BS-5467 and IEC 60502 and test reports shall be provided to GE. (ii) Type test as per relevant specification shall produce to GE. Make: Universal/Cable Corporation of India/Havell,s/Polycab /Nicco
All as per item No. 54 here-in-above but size 4 Sqmm, 2 Core complete all as specified and directed by Engr-in-charge.
All as per item No. 54 here-in-above but size 50 Sqmm, 4 Core complete all as specified and directed by Engr-in-charge.
All as per item No. 54 here-in-before but size 70 Sqmm, 4 Core complete all as specified and directed by Engr-in-charge.
All as per item No. 54 here-in-before but size 95 Sqmm, 4 Core complete all as specified and directed by Engr-in-charge.
All as per item No. 54 here-in-before but size 185 Sqmm, 4 Core complete all as specified and directed by Engr-in-charge.
S&F in replacement of MCCB 4 Pole, 415 V, with Microprocessor release including necessary fitting arrangement & testing complete of following sizes:-
63 Amps 4 Pole breaking capacity 16 KA complete all as specified and directed by Engr-in-charge. Make: Legrand /Schiender/Siemens
125 Amps 4 Pole breaking capacity 16 KA complete all as specified and directed by Engr-in-charge. Make: Legrand /Schiender/Siemens
Supply and fixing in replacement of power contactor 3 pole, 265 Amp 415 volt, 50 Hz with control rated operational current AC1, 415 V, type - HGS 65 and including taking down old complete all as specified and directed by Engr-in-Charge. Make : Havells, Cat No.IHPHA065300* /L&T /Schiender
M&L in replacement of timer switch single phase inbuilt over-ride facility, high switching capacity, tamper proof sealing, analog & digital version daily /weekly programming, supply voltage 240 VAC, frequency 50/60 Hz and electrical connection including taking down old one complete all as specified and directed by Engr-in-Charge. Make : L&T, Cat Part No. J648F1 / Havells/Legrand
Supply, install, testing and commissioning in replacement of LT Panel board outdoor type, double door, fabricated from quality 3.15 mm thick CRCA sheet and angle iron including powder coated, making earth connections etc. The panel should be dust and vermin proof factory fabricated, CPRI approved totally enclosed free standing/wall mounting type extendable from both sides, suitable for 415 volts, 50 Hz 3 phase 4 wire system complete in all respect and confirming to latest relevant of ISI specifications including necessary connections, inter connections with copper conductor cable of required size cable tray gear mounted including MS Angle Frame of size 40x40x5 mm structure at bottom, PCC foundation 1:2:4 for foundation etc complete suitable to AC 23 duty confirming to IS-4064 and with and including the following accessories :- (Make: Tricolite/ Adlec/ Universal Switch Gear Control/ Siemens/ L&T/Schneider/Jakson & Co.Note: The contractor shall submit detail Schematic Layout of the Panel Board for approval from Engr-in-Charge before procurement. (a) Bus bar chamber of 3 phase 4 strip 415 volts with 400 Amps main and 250 amps Neutral, Alu strip 1 set Supported on insulated plate form,interconnection of all incomings & outgoings. (b) MCCB 4 pole in coming 350 Amp 35/36 KA with earth fault relay - 01 Nos (c) MCCB 4 pole out going 200 Amp 25 KA - 01 Nos (d) MCCB 4 pole out going 160 Amp 25 KA - 02 Nos (e) Power contactor 3 pole, 150 amp, 415 Volts 50 Hz, - 01 Nos (f) Spare Pocket for Mounting MCCB - 01 Nos (g) Digital Voltmeter 0-500W Volt - 01 (h) Digital Amp meter 0 -400 Amp - 01 (j) Indicator lamp yellow , Red , blue (k) Complete wiring of the panel board. (l) CT ratio 350/5 amps (m) Timer Switch sigle phase, Tamper proof, analog version = 01 Nos
M&L in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type410 SP-31 (9.0 metres long) including fixing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of non transparent looping SMC kiosks pole box 3 phase of size 310 x 210 x 120 mm made out of engineering plastic one piece moulding Siemens grey colour with hold fast including 4 Nos of aluminium strips 60 amp of required size fixed on unbreakable insulator and one No of single pole MCB 1 to 6 Amp, C curve including taking out of old unserviceable complete all as specified and directed by Engr-in-charge. Make: Legrand/Universal switch gear control
Supply and fixing in replacement of LED Solar street light fitting 40 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed by Engr-in-charge. Note: Excavation & earth work shall be measured separately. The old unserviceable solar collector plates, tubular batteries and battery boxes of solar are deposited in E/M store yard. Make: CG/Bajaj/Havells
S&F in replacement of LED security/street light fitting 1 X 60 W LED 5700K energy saving & environmental friendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LEDs as light source and electronic driver suitable for pole dia 40 mm including 45 mm dia light grade tube bracket, bend to shape 1.80 mtr length with two Nos clamp of size 50mm x 6 mm with nut, bolts, washers etc including connection with 1.5 Sqmm two single core PVC insulated and PVC sheathed cable stranded Copper conductor upto ceiling rose and fixing on walls/pole complete all as specified and directed by Engr-in-charge. Make: Havells Cat Part No. ENDURACITYLITEPLATPLUSSL 30WLED757SASYBOPC or equivalent in CG/Halonix
Supply, fixing and testing in replacement of submersible electric driven pump and motor capacity 5 HP 3 phase 415 volts, 50 HZ with outer dia of pump not exceeding 150 mm having discharge capacity 5 lps at 90 Meter head (operating head range -113-74 mtr) or as per ground sample of same head complete all as specified and directed by Engr-in-charge. Make :- KSB / Kirloskar / Crompton.
S&F in replacement of 3 phase DOL starter suitable for 5 HP submersible pumps with voltage range 275 - 475 Volts, 50 Hz, relay range 9-14 amp, including necessary connections complete all as speicified and directed by Engr-in-Charge. Make: CG / Kirloskar / L&T
S&F in replacement of Submersible cable PVC insulated copper conductor flat 3 core 4.0 Sqmm 1100 volt complete all as specified and directed by Engr-in-charge. Make- Havells or equivalent ISI Marked.
S&F in replacement of water pressure booster multi stage centrifugal pump 1 HP of 25 mm X 25 mm suction/delivery sides, auto pressure control, AC supply with pressure gauge, pressure switch, brass NRV, brass five way connector, SS diffuser impeller, noiseless, SS shaft, high start / stop per hour (75/Hr), thermal cut out relay, ‘F’ class insulation, IP 44, prevents dust & spillage of water, vertical tank with auto ON/OFF pressure switch, liquid temperature 20 degree C - 120 degree C including necessary connections complete all as specified and directed by Engr-in-Charge. Make: Volvo pumps / CG or its equivalent
M&L complete for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2x04sq mm and 1x 4.00 sq mm as in continuous earth wire drawn in to & including PVC casing caping not less than 25mm dia ISI marked complete with fittings and fixings accessories laid complete all as specified and directed by Engr-in-charge.
Supply and fix air cooled split unit air conditioner electric driven (single phase) cooling capacity 1.5 Ton split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 complete all as specified and directed by Engr-in-charge. Make: Voltas / LLYOD/Hitachi
S&F in complete for sheet metal enclosure with two pin socket, chain plug cover with one MCB SP of 32 Amp capacity with alignment 10 KA ‘C’ series including electric connection complete all as specified and directed by Engr-in-charge.
S&F MS stand factory made suitable for condensing unit of split type AC duly powder coated complete all as specified and directed by Engr-in-charge. Make- ISI marked
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, and designed for input variation betwwen 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity 4 KVA including necessary connections complete all as specified and directed by Engr-in-charge. Make: V-Guard / Microtek / Everest
M&L for providing Chemical Earthing with copper earth plate 900mm x600mm x 5mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc complete with alternate layer of salt crystal and charcoal and Magnesium sulphate crystal as specified below:- (a) The earth pit should be of minimum 12 ft depth and 4 ft width (b) The copper plate should be of 900mm x600mm x 5mm thick. (c) The copper strip should be of 32mmx6mm dimensions (cross section) up to 7.5 mtr (d) The quantity used should be:- (i) Charcoal - 250 Kg (ii) Salt crystal - 200 Kg (iii) Magnesium sulphate crystal - 100 Kg (e) 3/4 inch dia GI pipe of enough length to reach just above copper plate fitted with funnel, meshed along with cap and running water should be provided for keeping the soil wet approx one mtr GI pipe be kept out side for connection of running water. (f) The pit shall be constructed in PCC (1:2:4) type B1 using (using 20mm grade stone aggregate) RCC slab shall be provided in RCC (1:2:4) type B-1 using 20mm grade stone aggregate, 50 mm thick pit cover reinforced with 8mm dia TMT bars, 75mm c/o both ways MS handle 12mm dia, PGI funnel wire mesh and GI watering pipe of 20mm bore (light grade) and earth lead protection pipe up to 7.5 mtr of 50 mm bore (light grade) shall be including the item.
M&L complete for Earthing with galvanized mild steel earth plate electrode of size 600 mm X 600 mm X 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr deep below the normal ground level with the top edge of the earth plate not less than 1.5 m (B.G.L.) and connected to GI earth strip 25X4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron including PCC (1:2:4) type B-1, precast RCC cover slab with suitable handle made of 12 mm round bar including necessary excavation & earth work in any type of soil, 20 mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40mm bore light grade galvanised steel tubing upto 7.5 mtr length for drawing earth lead wire protection common salt, charcoal etc complete all as shown in EP No 3 of SSR Part-I 2009 and testing on completion complete all as specified and directed by Engr-in-charge.
M&L for earth continuity conductor or copper main earthing lead fixed to wall or bottom on porcelain insulator or recess on chases or buried in ground or drawn in conduit/pipe of size 20mm x 3 mm strip completion complete all as specified and directed by Engr-in-charge.
M&L for earth continuity conductor or main earthing lead fixed to wall or bottom on porcelain insulator or recess on chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated of size 20mm x 4 mm galvanised iron strip completion complete all as specified and directed by Engr-in-charge.
S&F porcelain insulator on angle iron frame for mounting of strip heater all as required complete all as specified and directed by Engr-in-charge.
Deepak Electricals
Shiv Enterprises
Shrikanth Solutions
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .