Re-Configuration of Existing Terminal Building at Raja Bhoj Airport, Bhopal (Phase-2). SH- HVAC Work.
2026_AAI_295696_1
AAI/BPL/ENGG(E)/NIT-08/2026-27
Open Tender
Electrical Works
Works
Raja Bhoj Airport
Please refer Tender Document.
20 documents required · 20 mandatory
₹1,120
₹3.7 L
27 Oct 2026
27 Oct 2026
19 Nov 2026
27 Oct 2026
18 Nov 2026
27 Oct 2026
27 Oct 2026 - 6 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, installation, testing and commissioning of factory built, of double skin Horizontal floor mounted double skin type Air Handling Units with Chilled Water coil. The AHU housing shall be made of 48±2mm thick panels consisting of 0.8 mm thick galvanized pre- plasticised/powder coated sheet on outside and 0.63 mm thick plain GI sheet inside with polyurethane foam (PUF) 45±2 kg/m3 density insulation factory injected between them by injection moulding machine. AHU housing framing structure shall be thermal break structure type. The AHU shall have a fan section with Plug Fan, TEFC drive, IE-3 motor suitable for 215/415+ 10% volts, 1/3 phase 50 Hz AC supply, motor mounting arrangement inside the casings, stainless steel (18G) drain pan with PUF insulation, Coil section with ARI 410A compliant Cu Tube / Al finned 6 Row deep -12 FPI CHW coil, suitable for Chilled Water application, aluminium damper on the outlet of AHU, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, double fire retardant canvas connections and access doors to attend the motor/fan, etc. complete as per drawings and specifications. Filters shall have efficiency of 90 % down to 10 micron as per ASHRAE standard. AHU should be designed in such a way considering 20 to 30% clogged filters. The AHU without mixing box shall be complete in all respects .The motor shall be suitable for operation with VFD. | |||||
| 1.01 | 40000 CFM, 6RD Cooling Coil, Plug Fan, 65 mm SP | 1 | Each | - | - |
| 1.02 | 35000 CFM, 6RD Cooling Coil, Plug Fan, 65 mm SP | 2 | Each | - | - |
| 1.03 | 23000 CFM, 6RD Cooling Coil, Plug Fan, 65 mm SP | 1 | Each | - | - |
| 1.04 | 6200 CFM, 6RD Cooling Coil, Plug Fan, 65 mm SP | 1 | Each | - | - |
| 2Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cum density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including canvas cloth & Star Bond 30 - 36 complete and repairing of damage to building etc. required complete in all respect. as directed by EIC Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Neccesary MS support as per the CPWD norms, shall be provided to cater the load of chilled water piping including all accessopries like walls, flanges etc | |||||
| 2.01 | 200 mm dia. (32 mm thick insulation) including 7ml with star bond | 120 | Meter | - | - |
| 2.02 | 125 mm dia. (32 mm thick insulation) including 7ml with star bond | 120 | Meter | - | - |
| 2.03 | 65 mm dia. (32 mm thick insulation) including 7ml with star bond | 70 | Meter | - | - |
| 3Supply, installation, testing and commissioning U-PVC pipe with fittings of 10 kg /cm3. with 6mm thick Nitrile rubber of Class "1" including all fittings and jointing with solvent cement and , including cutting chieseling / holes in walls ,wherever required and making good the same, complete as directed by the Engineer in charge. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.89 MB
tenderdocument.pdf
Tender Documents • 11.59 MB
BOQ_344719.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .