Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | L1 | Accepted-AOC AOC issued | |
| 2 | L2₹1.2 L+₹9,786 (8.79%)Rejected-Finance 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L2 | Rejected-Finance That the Bid is not L1 | |
| 3 | L3₹1.3 L+₹22,902.97 (20.6%)Rejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L3 | Rejected-Finance That the Bid is not L1 | |
| 4 | L4₹1.4 L+₹25,963 (23.3%)Rejected-Finance NICHUPATTY BOLPUR BIRBHUM | BIRBHUM | WEST BENGAL | 713129 | L4 | Rejected-Finance That the Bid is not L1 |
| Sl No | Description | Qty | Unit | MAA TARA ENTERPRISE L3 | A.K.ENTERPRISE L2 | MOON LIGHT L4 | DIAMOND ELECTRIC SALE AND SERVICE L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | EI work:--
Dismantling the existing E.I. work by Co's own tools & tackles and take unnecessary items away from site by maintening normalcy as far as possible as per direction of EIC . | 1 | Item | 2,000 ₹2,000 | 900 ₹900 | 1,000 ₹1,000 | 500 ₹500 Lowest |
| 2.00 | A. Distribution wiring:---
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 12 mtr. | 10 | Pt | 1,261.54 ₹12,615.4 | 1,400 ₹14,000 | 1,500 ₹15,000 | 1,000 ₹10,000 Lowest |
| 3.00Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works | |||||||
| 3.10 | 19 mm dia 3 mm thick polythene pipe without earth continuity wire. [3(a)/E-2] | 35 | Mtr | 67.58 ₹2,365.3 Lowest | 90 ₹3,150 | 100 ₹3,500 | 80 ₹2,800 |
| 4.00Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works | |||||||
| 4.10 | 25 mm dia 3 mm thick polythene pipe without earth
continuity wire | 30 | Mtr | 68.6 ₹2,058 Lowest | 100 ₹3,000 | 120 ₹3,600 | 80 ₹2,400 |
| 5.00Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: R.R Kable / Havells/Glostar/KEI) of the following sizes in the prelaid polythene pipe as per GS. | |||||||
| 5.10 | 3 x (1.5 sqmm) [1(b) / E- 9 ] | 20 | Mtr | 111.61 ₹2,232.2 | 100 ₹2,000 | 120 ₹2,400 | 90 ₹1,800 Lowest |
| 5.20 | 2x(2.5 sqmm)+1x(1.5 sqmm) For computer board & power plag [ 1(s) / E-9 ] | 48 | Mtr | 135.63 ₹6,510.24 | 120 ₹5,760 | 150 ₹7,200 | 110 ₹5,280 Lowest |
| 5.30 | 2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ] | 60 | Mtr | 175.53 ₹10,531.8 | 150 ₹9,000 | 170 ₹10,200 | 140 ₹8,400 Lowest |
Tender Value
Refer Docs
EMD Value
₹2,749
Closing Date
4 Feb 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Necessary repair renovation work at Doctors duty room at MCH Building 1st Floor Under Kolkata Medical College - Part I E.I Work
2025_WBPWD_797229_1
WBPWD/AE/KMCESD/NIQ-129/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,749
15 Oct 2025
8 Jan 2025
6 Feb 2025
14 Jan 2025
4 Feb 2025
14 Jan 2025
Amount
EI work:-- Dismantling the existing E.I. work by Co's own tools & tackles and take unnecessary items away from site by maintening normalcy as far as possible as per direction of EIC .
A. Distribution wiring:--- Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Havells/Glostar/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 12 mtr.
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire. [3(a)/E-2]
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: R.R Kable / Havells/Glostar/KEI) of the following sizes in the prelaid polythene pipe as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) For computer board & power plag [ 1(s) / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Havells/Glostar/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2x(4 sqmm)+1x (2.5 sqmm)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes .vide pg no F-5 item no. 9
B. BDB, PDB, VTPN etc:--- Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.(Make-Legrand/LK/Schneider/ABB/Siemens)
4 way Enclosure [ 14 / D- 10 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS (Make-Legrand/LK/Schneider/ABB/Siemens)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS (Make-Legrand/LK/Schneider/ABB/Siemens)
C. Plug & Sockets:--- Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: R.R Kable / Havells/Glostar/KEI) to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin type plug socket & switch (Anchor) as per GS
On Board
Supply & Fixing 240V, 2 nos. 6A Piano Key socket and switch (MK: Anchor) on sheet metal switch board concealed in wall incl. S & F 175 x 100 x 65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover, incl. Ph, N, E Cu Bar and making necessary connections as required as to GS.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket (MK: Anchor) with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A sp MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240V, 20A, 1 no plug socket with separate 20 A Piano key type switch (Anchor) and 1 no. 6A Piano Key socket with switch on sheet metal switch board concealed in wall incl. S & F 200 x 150 x 65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover, incl. Ph, N, E Cu Bar and making necessary connections as required as to GS.
D. Supply of cables :--- Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (make-- Havells/Gloster/KEI/RR kable) as mentioned below :
4 core 35 sqmm (from VTPNDB to PDB)
E. Laying of cables :--- Laying of 4 core 35 sqmm Al. armoured PVC/XLPE cable (Havells/ Glostar /KEI) with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below : (from VTPNDB to PBDB) Vide page no F-1,F-3 Item no 2 & 5
a. on wall by clamp
b. Concealed in wall
Laying of 4 core 16 sqmm Al. armoured PVC/XLPE cable (Havells/ Glostar /KEI) with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below : (for autoclave and AC). Vide page no F-1,F-3 Item no 2 & 5
a. on wall by clamp
b. Concealed in wall
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : vide pg no F-4 item no. 7.C
4 core 35 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . vide pg no F-5 item no. 8a & 9 :
4 core 35 sqm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
50 mm dia
F. Supply of Light Fittings :--- S/D 4feet single commercial LED type fluroscent light fittings (make-- Philips TMC 502 1xT-LED 22W/ Wipro WIO921208P/Bajaj BLRB-DB-118/Havells Regal Batten) complete with all accessories with 1X18/20 Wt LED tube lamp corresponding to(Make- Philips MAS LED Tube 1200mm 18W 865 T8 I, 2100lm/ Wipro LL13-181-65SESL1-G1/Bajaj BLRB 20W CW LED/Havells Titania Neo)
S/D 4feet twin commercial LED type fluroscent light fittings (make-- Philips TMC 502 2xT-LED 22W/ Wipro WIO922208P/Havells Regal Batten) complete with all accessories with 2X18/20 Wt LED tube lamp corresponding to (Make- Philips MAS LED Tube 1200mm 18W 865 T8 I, 2100lm / Wipro LL13-181-65SESL1-G1/ Bajaj BLRB 20W CW LED/Havells Titania Neo)
G. Fixing of Light Fittings :--- Fixing only single/twin fluorescent light fittings suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp (125mmx125mm) as per G S Vide page no C-2, Item no 17
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length as per G S Vide page no C2 Item no 16
H. Supply of fans :--- S & D 230V,1200mm sweep ceiling fan, air delivery 230 CMM, (make-- Usha Striker 1 star/CG Revira Hi speed (HS) 1 star/Orient Falcon-425 SHS) complete with blades, canopy, fork, rubber bush, down rod, 1000mm safety wire & S3 capacitor etc.
S & D 250 V 50 HZ, 80watt, 18" (450 mm) high flo ( air delivery-- 4500 CFM, RPM-- 1400) non-oscillating type metal body Wall Bracket fan with inbuilt regulator, double ball bearing, intergally cast LM6 impeller (Make -EPC) .
I. Fixing of fans :--- Supply & Fixing 240V, fan regulator (Step type) (mk-Anchor) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting Vide page no D 14 Item no 29
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. Vide page no C-3, Item no 21.a.
S & F fan down rod (14 SWG) incl. necessary connection wire (2X1.5sqmm cu wire) and painting the down rod as per direction of EIC
fixing only 18" (450 mm) Wall Bracket fan with inbuilt on wall by S & F rag bolts ,nuts and washers (6 mm dia x 62 mm long) or as required incl. S & F 24/.20 PVC insulated flexible copper wire 0.5 mt. length
K. Miscellaneous :--- Supply and installation of 1-Phase timer in double door SPN DB (2+10) way providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires. The box should be painted by powder coated paint. a) 25A DP MCB -1 No. (b)Analog time switch LT240 VAC Base/DIN Mounting cat no-- J648B1 - 1 No. (c) 2- pole single power contactor 250V, 25A coil (Legrand, cat no-- 4125-44) - 1 No. (d) Add-on auxiliary contact block(1 NO+1 NC) -1 no (e) 60A capacity 3 way AC/DC Epoxy terminal block.- 1 No. (f) Indicator Lamp (ESBEE make)-2 Nos. (g) Toggle switch,(ON_OFF_ON)- 1 No. (h) Steel Key Lock – 1 No. (Make- L K /ABB)
S & Installation of 25A 3 pin Modular type Power Socket with plug top with indicator in 2 module GI modular type switch board with top cover plate flushed in wall incl. making necy. Connection with PVC Cu wire & earth continuity wire etc. for RAC machine. (Mk. Legrand).
Supply & fixing 250V control starter type OLP 30M, 11-21A range, starter with AC looad display (make-- ultratech/Electron)
S&F Cable end box (16SWG) for TPN horizontal MCBDB 6-way
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
A.K.ENTERPRISE (BID ID -6085411)
MAA TARA ENTERPRISE (BID ID -6001660)
MOON LIGHT (BID ID -6080045)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .