Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-Finance 17 BIPIN GANGULY ROAD KOL 30 | ₹5.9 L | L1 | Accepted-Finance Financially Accepted |
| 2 | L2₹5.9 LRejected-Finance | ₹5.9 L | L2 | Rejected-Finance Financially Rejected |
| 3 | L3₹5.9 LRejected-Finance | ₹5.9 L | L3 | Rejected-Finance Financially Rejected |
Tender Value
₹6.0 L
EMD Value
₹12,014
Closing Date
20 Jan 2026, 9:00 amClosed
Assistant Engineer
Assistant Engineer, PWD, Raiganj Electrical Sub-DivisionKarnajoraRaiganj
Urgent electrical repair and renovation work of central store of Raiganj Govt. Medical College and Hospital, Uttar Dinajpur. (Electrical work) ,Project ID HF252644990S000
2026_WBPWD_985385_1
WBPWD/AE/RESD/e-NIQ-22R /2025-26(1st Call)
Open Tender
ELECTRICAL WORKS ORG
15 days
Raiganj
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,014
Yes
2 Feb 2026
8 Jan 2026
22 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall / flushed in wall as per GS( Make - Legrand/ABB/L&K ) 8 Way ( Up to 250 A )
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ABB/L&K ) 4 Way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12Way ( Make - Legrand/ABB/L&K )
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. ( Make - Legrand/ABB/L&K ) 125 A FP
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS( Make - Legrand/ABB/L&K ) 63 A FP
Do and Do…..40 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per GS ( Make - Legrand/ABB/L&K )63A TP
Do and Do….. 32A TP
Do and Do….. 6-32 SP
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 8 mtr
Do And Do…..Average run 12 mtr
Do and Do…..On Board
Distribution wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2×84/0.3 (6 sqmm) + 1×56/0.3 (4 sqmm) as ECC [from HTPNDB to SPNDB/HTPNDB to UPS Plug]
Do and Do…. 2×36/0.3 (2.5 sqmm) + 1×22/0.3 (1.5 sqmm) as ECC [from HTPNDB to 16A Plug/Computer Board ]
Do and Do…. 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ from SPNDB to 6A Plug]
Do and Do…. 2x4sqmm + 1x2.5sqmm [from HTPNDB to AC]
Supplying & Fixing sheet metal inspection box (16 SWG) & bakelite/perspex top cover of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 150 mm x 100 mm x 65 mm
Do and Do…. 100 mm x 100 mm x 65 mm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc. incl. suplying sockets, tapes. 1.5sqmm
Do and Do…. 2.5sqmm
Do and Do…. 4 sqmm
Do and Do…. 6 sqmm
S&F 240 V, 20 A, 3 pin Modular type plug socket (LEGRAND-Myrius/L&K-Englaze/Havells-ORO/Brand approved by EIC)with 20A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc., as per GS.
S&F 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (LEGRAND-Myrius/L&K-Englaze/Havells-ORO/Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc., as per GS
Supply & Fixing 240 V,2 nos 6 A, 3 pin Modular type plug socket (LEGRAND-Myrius/L&K-Englaze/Havells-ORO/Brand approved by EIC) with 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (LEGRAND-Myrius/L&K-Englaze/Havells-ORO/Brand approved by EIC), incl. S&F 1no 240 V, 25 A, 3 pin Modular type plug top (Brand approved by EIC) and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire as per GS.
S/F 240 V, 25 A, Modular type starter ( LEGRAND-Myrius/L&K-Englaze/Havells-ORO/Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per GS.
Supply and delivery of Single LED Fitting (20Watt, 230VAC, 50hZ, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube [Make: Philips TMC 502 P 1xT-LED, Havells, Surya ,Bajaj Bajaj, CG,/jaquar or as per EIC]
S&F of 9W LED lamp on exsting angular batten, as directed by EIC.Philips / Equivalent of Havells /Cropmton/Havells/Surya/jaquar
Supply & delivery of 1200 mm sweep 230 volt AC Ceiling fan incl. Blades, canopy etc. With 18" down rod(14SWG), Fork(10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc., as directed by EIC [Make-Usha -1400MM STRIKER PWD ISI 1 STAR (Safety Wire &P2 Capacitor/ similar spec of Crompton/Orient
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire, as per GS.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc., as per GS.
Supply and delivery of 230V 300mm (12") Exhaust fan with all necessary accessories, as directed by EIC. [Make:EPCHeavy Duty or equiv Make]
S & Flouver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for the above Exhaust Fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire & making connection for exhaust fan, as per GS
Supply & Delivery of 1.1 kv grade XLPE-armoured AL. cable, as directed by EIC.[Make - Gloster/Polycab/Havells/ RR Kabel] 4Cx35 sqmm
Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed.
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
S&F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of following XLPE/PVC armoured cable, as per GS. 4Cx35 sqmm
Finishing the end of following XLPE/PVC armoured cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials, as per GS. 4Cx35 sqmm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing materials as required. 50 mm dia
Earthing with 50mm dia GI pipe (ISI-M) 3.64mm thick x 3.04 Mts. long and 1x4 SWG GI (Hot Dip) wire (4 Mts. long), 13mm dia x 80mm long GI bolts, double nuts, double washers incl. S&F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under-ground level and partly above-ground level driven to an average depth of 3.65 Mts. below the ground, as per GS.
Excavation of soil for installation of Earth Electrode and filling & ramming, for Soft Soil, as per GS.
S&F earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd., as per GS.
Connecting the equipments to earth busbar incl. S&F 2x8SWG GI (Hot Dip) wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as reqd. & mending good damages as per GS
(ii)The Rates to be quoted by all the bidders should be Inclusive of all taxes and duties including GST and LWC.
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 1.79 MB
BOQ_2405070.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid