Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC HOUSE NO 172 A CANAL ROAD SUJANPUR TEH DISTT PATHANKOT 145001 PUNJAB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L2₹15.5 L+₹75,559.25 (5.11%)Rejected-Finance C O 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Higher side quoted amount | |
| 3 | L3₹18.5 L+₹3.7 L (25.3%)Rejected-Finance | L3 | Rejected-Finance Higher side quoted amount | |
| 4 | L4₹20.1 L+₹5.3 L (36.1%)Rejected-Finance | L4 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
29 Oct 2024, 6:00 pmClosed
GE(West)Pathankot
GE(West)Pathankot
CERTAIN REPAIR/MAINT TO LEAKAGE, SEEPAGE, PLUMBING, SANITARY FITTINGS AND OTHER ALLIED WORKS IN OTM and MD ACCN IN AOR OF AGE BR-I UNDER GE(W)PATHANKOT
2024_MES_677356_1
GE/PKT-59/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
Pathankot
as per tender and NIT doc
9 documents required · 9 mandatory
₹500
GE(West)Pathankot
₹60,000
28 Dec 2024
30 Sept 2024
31 Oct 2024
30 Sept 2024
29 Oct 2024
15 Oct 2024
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Demolition of cement concrete (unreinforced) etc in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Dismantling floor, hearth or wall tilling and terrazo topping incl cement mortar bedding ( but not backing) removing serviceable tiles to stores and rubish off the premises
Taking down cement plaster/ including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Taking down, easing and adjusting shutters of any description, exceeding. 1.00 Sqm and not exceeding 2.00 Sqm each and re-fixing in the same or other opening completa all as specified and directed.
M&L for Brickwork with Fly Ash Bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified.
M&L burnt clay brick work with sub-class 'B' bricks,(old size) straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
All as per Srl item No. 07 here-in-before but except brick complete all as specified.
S&F Steel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. Glazed and gauged shutter. Glazed shutter made out of hollow' section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill 10 mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast, including plain/figured glass 3mm thick and stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.18mm & fixed with stainless steel wire staples`etc incl taking out existing windows and ventilators of any type and description complete all as specified and directed.
S&F in repair Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed by Engr-in-Charge.
Aluminium, anodised, barrel tower bolts 150 mm of extruded section and fixed. complete all as specified and directed.
Aluminium, anodised, handles 125 mm of extruded section and fixed.complete all as specified and directed.
S&F steel water tubing 15 mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling and floor. complete all as specified including taking up or down PPR/steel tubing 15mm bore pipe and connections.
S&F steel water tubing 20 mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling and floor. complete all as specified including taking up or down PPR/steel tubing 20 mm bore pipe and connections.
Disconnecting existing water tanks of capacity 1000 litres, any description, setting aside for repair, cleaning etc and hoisting reconnecting and refixing in same or other position incl cleaning with bleaching powder removing scaling etc ,provn of new GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer etc complete all as specified & directed.
Disconnecting existing water tanks of capacity 500 litres, any description, setting aside for repair, cleaning etc and hoisting reconnecting and refixing in same or other position incl cleaning with bleaching powder removing scaling etc ,provn of new GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer etc complete all as specified & directed.
S&F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling/taking down of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
S&F Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 25mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling/taking down of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
S&F in repair Concealed Stop valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fixed.
S&F in repair Bib tap 15 mm bore, Brass CP, fancy type with crutch or butterfly handle screwed down screwed for iron/PVC pipe or for brass ferrule and fixed, complete all as specified.
S&F in reapir Bib tap 15 mm bore, Brass CP, with crutch or butterfly handle screwed down screwed for iron/PVC pipe or for brass ferrule and fixed, complete all as specified.
S&F in reapir Stop valve /Angle valve (ISI Marked), fancy type, chromium plated with long shank and cup screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron /PVC pipe or for unions of 15 mm bore andcomplete all as specified.
S&F in repair brass Chromium plated shower roses 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete.
S&F in repair, Vitreous china squatting pan of pattern, long pan, 'Orissa pattern', size 580 x 440 mm white with integral foot rests (excl flushing cistern and flush pipe) but including provision concrete bedding CI floor trap etc complete all as specified and as directed
S&F in reapir , Vitreous china wash down water closet pan (Pedestal pattern) white (excl fixing bolts, flushing cistern and flush pipe) but including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel CP or aluminised hinging device.
S&F in repair floor mounting single piece Vitreous china wash down water closet pan , light colour complete including fixing to trap , alongwith PP soft close seat cover, hinges and accessories complete all as specified and directed.
S&F in repair CP Brass Hand Shower (Health Faucet) with 8 mm dia,1.2 m long Long Flexible Tube Chrome Finish & Wall Hook for Water closet complete all as specified and directed.
S&F in repair CP brass towel ring 20mm dia, fancy type, superior quality, fixed with and including chromium plated screws and wooden/plastic cleats complete all as specified and directed.
S& F in repair chromium plated brass central hole single lever WHB Mixture 15 mm bore for mixing hot and cold water with 450 long braided house 20 cartriage size screwed down, high pressure screwed for iron pipe complete all as specified and directed.
S&F in repair 3-in-1 wall mixture with telephonic shower for 15 mm bore pipe, cast copper alloy chromium plated complete all as specified and directed.
S&F in repair PVC flushing cistern 10 ltr capacity incl PVC connection inlet and and outlet connections,brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC all as specified and directed.
S&F in repair sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x460 mm and bowl size 410mmx330mmx 160mm complete all as specified and directed.
S&F in repairs Vitreous china wash basin, flate back white of,size 550 x 400 mm, including cutting for and pinning in ends of brackets or erecting stand including 32 mm bore CP waste pipe long screw thread and 32 mm dia flexible waste pipe complete all as spd and directed.
S&F in repair Vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, , flush pipe, grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed incl supply and fixing of CP coupling, waste pipe and cp brass spreder all necessary fittings, complete all as specified and directed.
S&F in repair PVC connection 15 mm bore with PTMT nuts of length 450 mm long.
S&F in repair glass corner shelf quarter round with CP Brass Bracket, complete all as specified and directed.
S&F in repair gun metal, gate valves suitable for 20 mm bore iron pipe, cast copper alloy, screwed down, high pressure, with wheel head/butterfly handle, screwed both ends for iron pipe or for unions.
S&F in repair gun metal, gate valves suitable for 15mm bore iron pipe, cast copper alloy, screwed down, high pressure, with wheel head/butterfly handle, screwed both ends for iron pipe or for unions.
M&L for Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed .
M&L for Glazed ceramic coloured tiles of size 450mmx350mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
M&L for Vitrified light shade ceremic tiles 600mmx600mmx 8.5 mm thick (Square/rectangular) polished in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:6, complete all as specified & directed.
M&L for Vitrified light shade ceremic tiles 600mmx 600mmx 8.5 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36Sqm in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick rendering in cement mortar 1:4, complete all as specified & directed.
M&L for Rendering 5 mm thick in cement mortar 1: 3 on concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified.
M&L for Rendering 15 mm thick on other than fair faces of brick work or concrete surface in CM 1:6, finished even and smooth without using extra cement.
M&L for 15mm thick rendering in two layers (5mm thick in CM 1:4 over 10mm thick in CM 1:6) on fair faces of brick work and concrete surfaces of wall, finished the surface even and smooth without using extra cement, mixing and including WPC @ 200ml/bag of cement, complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6, type C1 (using 20mm graded agg) as in plinth protection finished even and smooth without using extra cement.(incl necessary joint filling with mixture of paving bitumen & sand in 1:3)
M & L for Preparation of newly plastered surface of wall and applying two coat of oil bound distemper, white or tinted shade with and including priming surface with chalk whitening , complete all as specified.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L for preparing newly plastered surfaces and applying three coats of white wash as in ceiling etc.
S&F in repair GI pipe 32 mm dia light grade (in short length) as spout pipe in sunken floor slab laid in slope to brick wall with PCC (1:2:4) type B-0, complete all as specified.
M&L for 10 mm thick cement plaster in cement mortar 1:3 on brick or concrete surface of sunken floor finished even and smooth with mixing WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed. Note:- WPC will be measured and paid separately
M & L for bitumen blown any grade, applied hot, two coats, to concrete/plastered surfaces at the rate of 1.5 Kg per Sqm per coat and applying polythene film black, 50 micron complete for sunken floor slab and embedded in side wall / covered fillet complete all as specified and directed.
Supply only liquid water proofing compound
M & L for 25 mm thick P.C.C type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in sub floors for laying floor finish complete all as specified and directed.
M & L for Plain cement concrete 1:5:10 type E2 using 40mm graded crushed stone aggregate as in sunken floors and all as specified and directed.
M&L for PVC (SWR) floor trap, dia of outlet in 75 mm, plain including grating,and jointing with solvent cement fixed in repair.
Taking down eaves gutters and rainwater pipes (any size or pattern) , including all fitting ,head ,shoes ,bend, swan-nacks etc., including cleaning or refixing or removal to store complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with suitable clamp.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with suitable clamp.
S&F 110 mm bore PVC (SWR) bends any radius, with or without excess door.
S&F 75 mm bore PVC (SWR) bends any radius, with or without excess door.
S&F in repair, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints , laid in trenches or in floor.
S&F in repair, 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints , laid in trenches or in floor.
M&L for repairing of chajjas,beams, roof projections and faces of exposed reinforcement surfaces or damaged loose RCC surfaces including dismantling of old loose concrete or plaster by applying one coat of cement slurry @ 3kg/sqm and filling with cement concrete 1:2:4 type B-0 (using 12.5 m graded crushed stone aggregates) mixed with liquid water proofing compound (as per manufacturer's instructions) and finished with 05 mm thick rendering with cement sand mortar 1:3 with water proofing compounds (as per manufacturer's instructions) and finally applying two coats of exterior grade emulsion paints(weather proof/weather coat) with out any brush marks on the surface in any colour over and incl one coat of primer incl necessary scaffoldings upto four storeys height of bldgs.All painted areas site to be cleaned and handover as earlier without any extra cost to Govt complete all as spd and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in framed work and in any position
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F rolled mild steel roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 Gde E-165 .and applying two coat of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed.
M&L for prepration of New or previously untreated steel surfaces of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified.
Dismantling of plain or corrugated AC sheeting, any gauge, thickness, including ridge etc as in roof covering.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in Ridge/roof covering , fixed with self tapping screws as specified.
S & F in repair Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed incl taking down existing sheet of any type and descriptions.
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Racking out of existing pointing to brick tiles built in Cement mortar , laid flat, in floor, roofs, etc not less than 12 mm deep including washing the joints rubbish off the premises and keeping the surface to be wet prior to repointing complete all as specified and directed.
M & L for flush pointing in cement mortar 1:3 incl liquid water proofing compound @ 200 ml per bag of cement to brick tiles laid flat at roof complete all as spefified and directed.
Cleaning of grass, vegetation growth/saplings growth after uprooting from roof top completely incl making good disturbed sutrcafe in CM 1:4 complete to match the existing all as specified and directed.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 88,310.00 and any other reduction if any from quoted amount.
VAISHNAVI BUILDERS (BID ID -3147168)
VIKRAM SINGH MANHAS (BID ID -3145126)
VIJAY KUMAR LAKHNI (BID ID -3153330)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .