Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.4 L+₹64,466 (2.71%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹26.7 L+₹2.9 L (12.3%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹27.5 L+₹3.7 L (15.8%)Rejected-Finance BYE PASS DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹48.9 L
EMD Value
₹97,890
Closing Date
28 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SATWARI
GE SATWARI
MAINT AND PETTY REPAIRS OF E/M NATURE UNDER AGE E/M OF GE SATWARI
2024_MES_686471_1
GEJM-62/2024-25
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SATWARI
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
GE SATWARI
₹97,890
Yes
5 Feb 2025
30 Nov 2024
30 Dec 2024
30 Nov 2024
28 Dec 2024
14 Dec 2024
Amount
Attending the electrical complaints of no light due to some failure in the elecrical network like - joints failure in LT cable, DO fuses brunt/broken, MCCBs/ MCBs brunt/faliure, bus bar in LT panel brunt, jumper of over head line broken, OH conductor brunt/snapped, loose connections of LT installations & panels, LT cable demises/failure,Re-Laying only old serviceable cable , replacing unservicable cable with new cable ,Tracing all nature of faults & rectifying the same and replacing the brunt/damaged parts of the connecting disturbed electrical services line on required basis and checking the input voltage at meter side, observing the UG cable failure, making temporary power supply arrangement by laying the OH /UG Cable service mains from nearest panel, checking the supply etc round-the- clock (24x 7days) and provide swiftly & smooth functioning of electrical network in the AOR of GE Satwari complete all as specified and directed . Note:- (a) The contractor must ensure that compaints attender should be skilled electrician having ITI diploma with minimum 5 years experience in related field . (b) All materials required for repair/replacement shall be measured and paid separately as 'supply only' and labour element shall be deemed to include in the quoted rate of the item. (c) Excavation & earth work required shall be measured and paid separately in relevant items of BoQ. (d) If contractor fails to attend the complaint within one hour of communication of complaints,a penalty of Rs 2000/-per complaint per hour shall be imposed till the time the complaint is attended. A proper record of complaints will be maintained by the concerned JE duly signed by the contractor.
Supply only copper DO fuses 5 Amps to 10Amps rating for uses in GOD controlling 11000 Volts HT supply complete all as specified and directed.
Supply only HT insulation self bonding electrical tape 20mm wide & 20m in length to be used on aluminium conductor of voltage cap of 11 KV to 66 KV complete all as specified and directed .
Supply only LT insulation self bonding electrical tape 17mm wide & 6.5m length in multi colours to be used on aluminium conductor of voltage cap 220 volts to 440 volts complete all as specified and directed .(Each packet contains 30 rolls)
Supply only Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately..
Supply only Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately...
Supply only Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply only Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 2 core, aluminum conductor, 1100 volts grade under ground cable complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply only Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 95 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply only Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 35 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply only Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 50 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade under ground cable complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
Supply only aluminium lugs suitable for XLPE cable 10 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 16 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 25 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 35 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 50 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 70 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 95 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 120 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 150 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 185 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 240 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 300 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 400 sqmm complete all as specified and directed
Supply only aluminium lugs suitable for XLPE cable 630 sqmm complete all as specified and directed
Supply only cable jointing kit for 11KV grade cable for straight through indoor/outdoor heat shrink type joint including all jointing material & accessories suitable for aluminium conductor cable of size 70 to 150 sqmm complete all as specified and directed .
Supply only cable jointing kit for 11KV grade cable for straight through indoor/outdoor heat shrink type joint including all jointing material & accessories suitable for aluminium conductor cable of size 185 to 300 sqmm complete all as specified and directed .
Supply only cable end termination jointing kit, indoor/outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cable of size 70 to150 sqmm complete all as specified and directed .
Supply only cable end termination jointing kit, indoor/outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cable of size 185 to 300 sqmm complete all as specified and directed .
Supply only MCCB 630 Amp, 4 pole, 36 KA with thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 400 Amp, 4 pole, 36 KA with thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 4 pole, 315 Amp, 36 KA with thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 250 Amp, 4 pole, 36 KA with thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 200 Amp, 4 pole, 25 KA with thermal and magnetic releases with Ics=100%Icu.conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 160 Amp, 4 pole, 25 KA with thermal and magnetic releases with Ics=100%Icu.conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 125 Amp, 4 pole, 16 KA with thermal and magnetic releases with Ics=100%Icu.conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra costetc complete all as specified and directed .
Supply only MCCB 100 Amp, 4 pole, 16 KA with thermal and magnetic releases with Ics=100%Icu.conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 63 Amp, 4 pole, 16 KA with thermal and magnetic releases with Ics=100%Icu.conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 100 Amp, 3 pole, 16 KA with thermal and magnetic releases with Ics=100%Icu.conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCCB 125 Amp, 3 pole, 16 KA with thermal and magnetic releases with Ics=100%Icu.conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed .
Supply only MCB TPN, 63 Amps, 10 KA, 'C' Curve in existing panels including making all connections with proper thimbling and connectors etc complete all as specified and directed .
Supply only MCB DP, 40 Amps, 10 KA, 'C' curve including making all connections with proper thimbling and connectors etc complete all as specified and directed .
Supply only MCB DP, 32 Amps, 10 KA, 'C' curve including making all connections with proper thimbling and connectors etc complete all as specified and directed .
Supply only MCB 4 pole, 6 amp to 32 Amps, 10 KA, 'C' curve including making all connections with proper thimbling and connectors etc complete all as specified and directed .
Supply only MCB 4 pole, 40 amp,10 KA, 'C' curve including making all connections with proper thimbling and connectors etc complete all as specified and directed .
Supply only MCB 4 pole, 50 amp to 63 Amps, 10 KA, 'C' curve including making all connections with proper thimbling and connectors etc complete all as specified and directed ..
Supply only MCB SP, 6 to 30 Amps, 10 KA, 'C' curve including making all connections with proper thimbling and connectors etc complete all as specified and directed .
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m depth for foundation, laying of cable etc or for shaft, wells, cesspits, manholes pier holes etc 10 sqmm on plan and n.exe 1.5m in depth and getting out in any type of soil complete all as sepecified dirceted .
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick in any type of soil complete all as specified and directed .
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made un-reinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as sepecified dirceted .
SATISH AND CO (BID ID -3194812)
M/S S K Electricals Regd (BID ID -3191285)
M/S GULATI ENGINEERING WORKS (BID ID -3194756)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .