Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹35.8 L
EMD Value
₹3.6 L
Closing Date
23 Nov 2026, 12:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
SECRETARY
RAJA KA TAAL TIRAHA NH-2 FIROZABAD
Supply and Installation of High Mast Light at Police Line Firozabad and PMAY Ussaini Firozabad
2026_FSDUP_1206527_1
739/D.A./2026-27 Dt 06/11/2026
Open Tender
Electrical Work/ Equipment
Percentage
Firozabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
VC
₹3.6 L
7 Nov 2026
7 Nov 2026
23 Nov 2026
7 Nov 2026
23 Nov 2026
7 Nov 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing of 12.5 mtr. High mast shaft of approved make with rising system hot dip glavanized inside & out side dip, heaving pole sheet thickness 3mm. Top dia minimum 150 mm, bottom dia minimum 310mm, base plate 25mm thick, suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 uminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6mm dia, double drum winch. including making suitable foundation as per manufature drawing/site reuiment along with foundation bolts nuts,washers, anchor plates etc complete in all respect. (PWD SOR LUCKNOW 2024 S.I.No. 21.3) | 9 | Cum | 2,46,218 | ₹22,15,962 |
| 2 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing with toughend glass! UV stabilized PC Cover and lenses built with mandatory driver set suitable for 140 to 150 Watt. Confirming to IP 66, IK 07 and abov protection complete in all respect ineluding Labour. 16800-18000 system lumens, High power LED with lenses,>120
Lm/W, P.F.>095, THD <10% at full load, CRI >70, Potted driver Set in Metal housing (Not Circuitory) Phase to phase Protection at 440V & >300V auto cut and re-start feature, 4 KV internal Surge Protection, with 5 years warranlee. (PWD SOR LUCKNOW 2024 S.I.No. 23.25) | 54 | Cum | 9,269.66 | ₹5,00,561.64 |
| 3 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. f(ii) 40 A TPN (UPPWD SOR 2018 - 807f(ii) | 9 | Sqm | 29,300 | ₹2,63,700 |
| 4 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive &
conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (UPPWD SOR 2018 - 725B) | 9 | Sqm | 10,040 | ₹90,360 |
| 5 | Supply and laying of 32 mm x 6 mm G.I. strip from earth
electrode directly in the ground as required complete in
all respect. (UPPWD SOR 2018 - 717) | 45 | Rmt | 150 | ₹6,750 |
| 6 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (UPPWD SOR 2018 - 501(i)) | 1,000 | Sqm | 343 | ₹3,43,000 |
| 7 | 120 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).
Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver
efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical
circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As
per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (CPPWD DSR Pg. No. 52 Item No. 8.14.16) | 40 | Cum | 4,066 | ₹1,62,640 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
technicalbids.pdf
Tender Documents • 0.66 MB
BOQ_2287350.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .