Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹41.9 L+₹1.2 L (2.87%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹43.7 L+₹3.0 L (7.39%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹44.0 L+₹3.3 L (7.98%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹47.5 L+₹6.7 L (16.6%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
₹42.1 L
EMD Value
₹84,180
Closing Date
30 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
ADDN ALTN TO EXISTING FOYER NEAR BUILDING NO P 513 ASHOKA HALL AT CDM SECUNDERABAD UNDER GE NORTH SECUNDERABAD
2023_MES_630149_1
8736
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH) SECUNDERABAD
₹84,180
Yes
24 Jan 2024
28 Nov 2023
1 Jan 2024
28 Nov 2023
30 Dec 2023
16 Dec 2023
Amount
Dismantling wrought iron or mild steel work or SS Work or structural steel of any description not otherwise provided complete all as specified and as directed.
M & L for Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30cm in depth, n. exc 1.5m deep,1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m and getting out in any kind of soil complete all as specified and as directed.
M & L for Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 1.5m in depth & 1.5m in width as well as 10Sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m and getting out in any kind of soil complete all as specified and as directed.
M & L for Cement concrete type D2 1:4:8 (40mm graded stone aggregate) in foundations filling and mass concrete complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material exc. 50m & n.exc 250m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M&L for reinforced cement concrete design mix M25 (20 mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for Formwork to sides of concrete foundations in rough finished, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
M&L for TMT steel bars 10mm dia and over cut to length bent to shape as required complete all as specified and as directed.
M&L for TMT steel bars 8mm dia in stirrups, spacers and binders bent to shape as required complete all as specified and as directed.
M&L for reinforced cement concrete design mix M25 (20 mm graded stone aggregate) in columns complete all as specified and as directed.
M&L for 20mm thick granite stone slab as in cladding over 20mm thick rendering in CM 1:3 complete all as specified and as directed.
M & L for Formwork to rectangular sides in rough finished of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M & L for preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of aluminium red oxide primer complete all as specified and directed.
M & L for Rendering 5mm thick on exposed faces of brick work or concrete surfaces in CM 1:3 complete all as specified and as directed.
M & L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and as directed.
M&L for preparation of new wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
S&F Rolled hollow sections, I sections, angle, channel Fe-410- W (Gde-E-250) quality-A, etc., as in main and cross beams, hip and jack rafters; purlins, tie runners where connected to common rafters fixed with angle cleats or other connecting plates etc., complete all as specified and as directed.
S&F Rolled hollow sections Fe-410-W(Gde-E-250) quality-A etc as in stanctions/ vertical column fixed with base plates or other connecting plates etc., complete all as specified and as directed.
S & F MS plate 8mm to 12 mm thick plain Fe-410- W (Gde-E-250) quality-A, cut to shape forming holes and welded to truss and vertical post as base plate complete all as specified and as directed.
S&F mild steel screw bolts (machine made), diameter of shank 16 to 20 mm, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10 cm and n exc 15 cm long complete all as specified and as directed.
S&F mild steel screw bolts (machine made), diameter of shank 16 to 20 mm, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5 cm and n exc 45 cm long complete all as specified and as directed.
Demolition of RCC in plinth beam, column & parapet etc any thickness (reinforced) complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, laid dry complete all as specified and as directed.
S&F Toughened glass 12mm as in hinged doors, partitions, automatic doors, cladding and similar work including cutting to shape, drilling holes required with frosted finish etc., complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrange complete all as specified and as directed.
Demolition of Concrete in ground floors and pavings n exc 15cm thickness complete all as specified and as directed.
M&L for Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) 75 mm thickness as in sub base complete all as specified and as directed.
M&L for Brick work with subclass 'B' bricks, straight or curved on plane exc 6m mean radius built in CM 1:4 complete all as specified and as directed.
Dismantling of floor, hearth or wall tiles including cement mortar bedding (but not backing),removal serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M & L for Preparing old steel surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Vitrified Ceramic tiles Dark shade double charged 10mm thick (square/ rectangular) matt finished, area of each tiles exceeding 0.42Sqm but not exceeding 1.00 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed. Make: Kajaria or equivalent in Johnson/Somany as approved by GE.
M&L for Vitrified Ceramic tiles Dark shade 10mm thick (square/ rectangular) matt finished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 Sqm, in skirting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 10mm thick rendering in CM 1:3 complete all as specified and as directed. Make: Kajaria or equivalent in Johnson/Somany as approved by GE.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. Note: The frame work will be suitably modified as per the size of the WPC panel given below and the contractor will have to quote his rate accordingly and he will have no claim extra on this account.
S&F WPC (Wood plastic composite) ceiling boards of size 300mmx3000mmx6 to 8mm (Approximately 1 foot X 10 feet) thickness or (Any equivalent size/profile as required & decided by GE) of required colour over necessary frame work (hanger bars & frame work with fillets, cleats etc., measured separately) as false ceiling with required SS Screws and glue including all fixtures complete all as specified and as directed.
Dismantling of Plain or corrugated galvalume steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F Mangalore pattern (BMPL tile Profile) or (Any equivalent size/profile as required & decided by GE) Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.30 to 0.80mm thick of an colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding/crimped/ridge sheet at ends as required to wall, fixed with self tapping screws & silicon joint sealant complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.30 to 0.80mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof ridge covering/cladding to wall, Rain water gutter along roof, as rectangular shape folded down take pipe as required, fixed with self tapping screws and with flat fasteners (Flat iron measured separately) & silicon joint sealant complete all as specified and as directed.
M&L for M.S support/fasteners to sheet gutter along rafter/stanchions etc., of FI 50mm x 5 mm complete all as specified and directed.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made complete all as specified and directed.
M&L for 4.8 mm thick tinted sheet glass, ordinary quality and fixed with glazing clips and oil putty in squares exceeding 0.5 Sqm in each pane complete all as specified and directed.
M&L for 4.8 mm thick tinted sheet glass, ordinary quality and fixed with glazing clips and oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F UPVC (SWR) pipes 110mm bore doubled socketed, in any length with rubber ring joints, fixed on walls complete all as specified and directed.
S&F UPVC (SWR) pipes 110mm bore double socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F UPVC/PVC (SWR) single 'T' 110 mm dia complete all as specified and directed.
S&F UPVC/PVC (SWR) door bend 110mm dia complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/size of light/fan/tube/power/two way/bell point etc., on TW batten/conduit including removal of batten/conduit/gutties/wooden boards/switches/sockets/regulators/light fittings etc., and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
M & L for Point wiring on concealed conduit with 1.5Sqmm FRLS copper conductor single core PVC insulated sheathed 1100 V multistranded drawn through conduit and including rigid 20 MM PVC conduit and conduit accessories of suitable dia medium grade and modular accessories including fixing/grouting sunken/ surface along with modular flush box of suitable thickness covered with suitable modular cover plate including running up of 1.5 Sqmm FRLS copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc complete all as specified and directed for :- (a) One light/fan/Bell point controlled by one, one way switch 5A, SP NOTE: Rate of Modular Flush box and Cover plate are inclusive of rate quoted by the contractor
All as per Sl item No 48 above, but one 2/3 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed.
All as per Sl item No 48 above, but one 3 Pin 5 Amps switch socket Independent board complete all as specified and directed.
Description all as per Sl item No 48 here-in-before, but using 2.5 Sqmm FRLS single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 5/15 Amps switch socket combination point including running of 2.5 Sqmm FRLS copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed.
S & F Modular switch 1 way 10 A, 1 Module capacity 230 volts complete all as specified and directed.
S & F Modular switch 1 way 16 A, 1 Module capacity 230 volts complete all as specified and directed.
Supply and fix socket outlet modular type multipurpose 2/3 Pin, 10 amps, 230 volts combined 2 Module complete all as specified and directed.
Supply and fix socket outlet modular type multipurpose 2/3 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed.
S & F Modular ceiling fan regulator stepped type heavy duty suitable to work on 230 volts, 2 Module complete all as specified and directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65mm x 50mm complete all as specified and directed.
M & L for chipping the wall for fixing of DB and plastering the disturbed surface along with putty and existing colour complete all as specified and directed.
S&F sheet metal enclosure vertical type MCB DB TPN 4 way double door with suitable rated bus bar 415 volts suitable for and including MCB TPN as incomer with suitable rated copper bus bar with neutral link including provision for MCB TPN as incomer and SP MCBs as outgoing and total number of modules equal to MCB TPN + 12 with blanking plates and fixed flush to wall and making good the disturbed surfaces etc., complete all ass specified and as directed. Note: MCB TPN and MCB SP will be measured and paid separately.
Supply, fix, connecting and testing MCB, Single Pole (SP) 6 to 32 Amps, 240 Volts of rupturing capacity 10 KA, 'C' Series complete all as specified and as directed.
Supply, fix, connecting and testing MCB, Triple Pole Neutral (TPN) 63/100 Amps, 415 Volts of rupturing capacity 10 KA, 'C' Series complete all as specified and as directed.
Supply, fix, connecting and testing MCB, Triple Pole 40/63 Amps, 415 Volts of rupturing capacity 10 KA, 'C' Series complete all as specified and as directed.
S & F of LED Luminarie 600mmx600mm 35/36 watts, 220 Volts AC recessed mounting light fixture type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver 3 core flexible copper conductor cases of suitable size complete with lumianrie system efficacy >100 lm/w with IP & surge protection of 10KV, power factor >0.95 complete all as specified and directed. Make: PHILIPS/HAVELLS/WIPRO.
S & F 10mm MS False ceiling Iron ring of size 2X2 suitable for POP/GYPSUM False ceiling and suitable for above mentioned recess mounting light complete all as specified and directed.
S & F in replacement of Security Lights of 25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution with suitable pipe bracket 32 mm dia 0.60 Mtr length fixed on wall with suitable flat iron clamps and nut bolts including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and directed. Make: Havells Model ENDURASUNDOWNSL25WLED765 PASYBOPCIHD or equivalent make in Wipro as approved by GE.
M & L for Submain wiring with two single core 4 Sq mm FRLS PVC insulated copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and concealed conduit accessories of suitable dia medium grade including running up of one runs of 4 Sq mm FRLS copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing complete all as specified and directed. Note:-Two runs of cable, one run of earth continuity conductor and one run of conduit shall be measured and paid as one unit length.
M & L for Submain wiring with four single core 10 Sqmm PVC insulated unsheathed FRLS copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of suitable dia medium grade including running up of one run of 10 Sqmm FRLS copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete and making good the disturbed surface to match with the existing complete all as specified and directed. Note:- Four runs of cable, one run of earth continuity conductor and one run of conduit shall be measured and paid as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead 4 mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI pipe light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of SSR Part-I and connection to earth test point all as specified incl testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4 mm size and protection pipe of 15 mm bore GI light grade.
S&F Ceiling Fans, complete with three blades, down rod, accessories 230 V, 1200 mm sweep, with Squirrel cage induction motor including provision of PVC insulated copper flexible cord from ceiling rose to connection of ceiling fan complete all as specified.
Disconnecting and removing wall fan of any capacity any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc., overhauling, lubricating with approved lubricants, reassembling, including replacement of worn out/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan. NOTE :- (1) Necessary repairs/ replacement of unserviceable parts shall be measured and paid separately. (2) Labour element for replacing of unserviceable parts deemed to be included in rate quoted.
Material and labour for rewinding of the wall fan complete with equivalent new super enameled copper wire of existing gauge and weight as per manufacturer's design and instructions including varnishing of wall fan of any make and any sweep complete all as specified and directed including taking out burnt copper wire complete all as specified and directed. Note: Old winding material is property of the contractor.
S&F in repairs of Ball bearing/Brass bush of wall Fan upto 400 mm complete all as specified and directed.
S&F in repairs of Capacitor of wall Fan upto 400mm complete all as specified and directed.
S&F in replacement of fan motor upto 400 mm size complete all as specified and directed.
RAM CHARAN CONSTRUCTIONS
VACON INFRASTRUCTURES
SAI RUPA CONSTRUCTIONS
G.CHANDRIAH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .