GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF COVERED PATHWAY FOR DOG UNIT, SPL REPAIR TO HARDSTADING NEAR BLDG NO P-103/H, SPECIAL REPAIR TO MT OFFICE (BLDG NO P-23) AND BLDG NO T-263 FD HOSPITAL AT DHURMUND GARRISON UNDER GE (I) 873 EWS
2021_MES_491265_1
NIT-54 of 21-22
Open Tender
Civil Works
Item Rate
240 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (I) 873 EWS
₹35,000
Yes
6 Jan 2022
29 Nov 2021
30 Dec 2021
29 Nov 2021
27 Dec 2021
13 Dec 2021
60 days
Amount
Excavation in post holes (or similar holes) each not exc. 0.50 cum, in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed.
PCC 1:3:6, (nominal mix), type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete for posts, complete all as specified & directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
Mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, square / rectangle sections, channel or flat section) including distance pieces, cleats etc. confirming to grade FE 410-0 complete all as specified and directed.
Mild steel framed work as in plates (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Gde Fe 410-0 or Fe 310-0, complete all as specified & directed.
Preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified & directed.
Hard core of gauge not exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified.
75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base, complete all as specified and directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
Chequered cement concrete tiles, coloured, machine pressed, factory made of size 30cmx30cm, 25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 20mm thick screed layer in cement mortar 1:4, complete all as specified.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) un-reinforced, complete all as specified.
100mm thick plain cement concrete 1:2:4 type B-1 (20mm graded crushed aggregate) as in hardstanding, finishing surface even & fair, complete all as specified and directed
Forming Construction joints 100mm deep x 10mm wide, filled with sealing compound grade ‘A’,, thickness of slab 100mm complete all as specified & directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified & directed
8 mm thick non asbestos fiber cement plain building boards in false ceiling on and incl aluminium snap grid work 605 x 605 mm with using 36.5mm x 23.5 mm x 1.5 mm thick main tee, 23.5 x 23.5mm x 1.28 mm cross tee and 25x25x1.5mm angles fixed to perimeter of wall including necessary supporting hanger with 3 mm dia GI wire and J bolts washer nuts for securing frame work to ceiling suspended @ 120 cm c/c both ways, complete all as specified and directed.
25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base, complete all as specified and directed.
Non-skid cermic coloured tiles 7 to 8 mm thick (square / rectagular) area of each tile exceeding 0.18 Square metre but not exceeding 0.36 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over screed bed 15 mm thick in cement mortar 1:4 complete all as specified.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 15 mm thick on other than fair faces of brick work or stone masonary surfaces in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
Applying three coats of white wash including preparation of newly plastered surfaces of wall complete all as specified.
Preparation of newly plastered surface of wall including cornices pilaster etc, and applying two coats of cement base paint over a coat of alkali resistant primer, complete as specified and directed.
Preparation of old decorated plastered surface of wall including cornices by washing, rubbing down and stopping of distempered surfaces of walls and applying two coats of oil bound distemper white or tinted, complete as specified and directed.
Preparation of old decorated plastered surface of wall including cornices pilaster etc, and applying one coat of cement base paint, complete as specified and directed.
One coat of synthetic enamel paint including preparation on old painted steel surfaces of any description, not otherwise described over 10cm width or girth, complete, all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Square metre and not exceeding 4.0 Square metre each including taking out hold fast complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area not exceeding 1.5 Square metre each including taking out hold fast complete all as specified and directed.
Aluminium annodised frame for door/ window/ ventilator with one or more rebates not less than 2mm thick including jointing cleats for fixing etc complete all as specified and directed.
Anodised aluminium door shutters, fixed and sliding type without sash bar, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
Sheet glass ordinary quality, 4.8mm thick, fitted with snap bedding rubber gasket in aluminium doors/windows exceeding 0.50 Square metre in each pane, complete all as specified.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified.
Sheet glass ordinary quality, 3mm thick, fitted oil putty or woeeden beads in squares not exceeding 0.50 Square metre in each pane, complete all as specified.
12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work fixed in repair complete all as specified and as directed.
Framed work such as grills, grating etc with ends of bars shouldered and or riveted, or forged into spikes, framed guard bars, barrel, iron doors, ladders, balusters, walkway, frame work of water tanks and similar work confirming to Fe-290 Gde E-165 complete all as specified and as directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified.
1.25mm thick pressed steel frames with one shop coat of red oxide primer 105 x 60 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges (ISI marked), lock strike plate, including cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregate) as in filling hollow of frame with plain cement concrete and hold fast after taaring of hollow portion of frame complete all as specified and directed.
30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
Two coat of synthetic enamel paint over a coat of pink primer on new wooden surface of any description, not otherwise described over 10 cm width or girth, incliding preparation of surfaces complete, all as specified.
Butt hinges of size 100mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21, complete all as specified.
Aluminium anodised, barrel tower bolts of extruded section of size 150mm ISI marked and fixed, complete all as specified and directed.
Extruded aluminium alloy handles, fabricated type, anodised of size 150mm and fixed, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Sheet glass ordinary quality, 4mm thick, fitted with snap bedding rubber gasket/oil putty or woeeden beads in squares not exceeding 0.50 Square metre in each pane including hacking out old, complete all as specified.
Sheet glass ordinary quality, 4mm thick, fitted with snap bedding rubber gasket/oil putty or woeeden beads in squares not exceeding 0.50 Square metre in each pane, complete all as specified.
Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified.
PVC wall panelling made up of PVC hollow panels 25/30cm in width and 10mm thickness interlocking pattern of approved shade and design fixed to wall or ceiling all as specifed and directed.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position (unframed work), complete all as specified.
2nd class hard wood (Sal/Hollock) as in scantling, clean sawn timber, fixed in framed work, complete all as specified.
Corrugated galvanized iron sheets 0.63mm thick, grade ‘O’, with 120gm per sqm zinc coating fixed with `L’ & `J’ hooks and washers as in roof covering with two corrugation side lap (Horizontal distance of side and end lap shall not be less than 145mm and 150mm respectively and depth of corrugation shall be 12.5mm), complete all as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified.
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified
Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4, complete all as specified.
Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, size of each slab not be less than 0.28 Square metre, including rubbing and mirror polishing complete over and including 20mm thick screed bed in CM 1:4, complete all as specified.
75 mm thick plain cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in plinth protection and laid in panels complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight all as specified and directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified.
Precast cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc.), and similar articles with plain faces including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match, complete all as specified
Mild steel TMT bars 10mm dia and over, cut to length bent to shape including binding with with and including MS annealed wire of dia not less than 0.90 mm, complete, all as specified and as directed.
Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete, complete all as specified & directed.
Taking down cupboard shutters/shelves and refixing after carrying out repairs as detailed here-in-after, complete all as specified.
0.90mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with adhesive as per manufacturer instructions, complete all as directed.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified.
125mm size hasp & staple, aluminium, safety type, including bolt to hinge plate and fixed with screws, complete all as specified.
Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
All as per Srl item No 70 above except bricks.
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and complete all as specified and directed.
15mm dia GI steel water tubing ,medium grade ISI marked, with and incl all fittings such as bends, elbows, tees, short pieces, diminishing pieces, union etc complete to walls and ceilings or laid in floors complete all as specified.
Bib taps long body 15mm bore of cast copper alloy chromium plated (ISI marked) fancy type, screwed down, high presure, screwed both ends for iron pipe or for brass ferrule, fixed in repairs complete all as specified and directed.
Stop valve/angle valve of cast copper alloy chromium plated (ISI marked), fancy type, screwed down high pressure, screwed both ends for iron pipe or for unions 15 mm bore, fixed in repairs complete all as specified and directed.complete all as specified.
PVC (SWR) pipes 100mm dia any length single socketed with rubber ring joint, laid in floor/walls as soil pipe(vent pipe), complete all as specified and directed.
PVC (SWR) floor trap of 110mm dia of outlet, plain with grating including jointing with solvent cement fixed in repair, complete all as specified.
PVC (SWR) bends any radius 110mm bore, complete all as specified.
Stainless steel sink with drainage board made of stainless steel 1mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever cast iron bracket, connecting union etc. and overall size 915x460mm with bowl size 410x330x160mm, fixed in repairs complete all as specified & directed.
Taking out carefully copper / aluminium point wiring, (Light, fan, socket or power) complete with all fitting, fixtures such as switch socket out let, ceiling rose, holder, regulator etc. including making good the disturbed surface of wall/floors, complete all as specified and as directed.
Point wiring with multi stranded copper conductor of size 1.5 Sqmm PVC insulated unsheathed FRLS cable in and including PVC casing capping 20/30mm size or as required at site including its fittings and fixtures such as ties, bends, elbows and junction boxesetc. including 1.50 Sqmm copper earth wire (green colour) FRLS Cable as earth continuity conductor connected to main earthing and common earth terminal for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes and making good to disturbed surfaces of wall / floor, complete all as specified and as directed.
All as per the description of Serial Item No 81 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 81 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed.
All as per the description of Serial Item No 81 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed.
Switch piano, flush type, 5 Amps, single pole, one way, complete all as specified and as directed.
Bell push, flush type, 5 Amps, single pole, one way, complete all as specified and as directed.
Socket out let , 2 in 1, 2 and 3 pin 5/6 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Wall surface mounted tube light fitting 18/20 watt LED with electronic driver and extrude aluminium heat sink integrated polycarbonate LED channel with white acrylic cover and including 1X18 watt LED tube rod and complete accessories , internally pre- wired including connection cable of copper conductor size 3-core ,23/0.0076 passing through PVC flexible conduit from ceiling rose to light fitting connector complete all as specified and as directed by Engineer-in-Charge. Make :- CROMPTON Cat No LCTL-18-CDL OR HAVELL's Cat No LHEXBLP7UN1W018 OR BAJAJ Cat No BLRBDB118
Lamp holder, insulated body, with back plate for batten fittings with and including 9 watt LED bulb in white colour with maximum lumen output (LM) 650K, complete all as specified.
Surface mounted LED bulk head light fitting 9/10W, IP66, operating voltage 220-240 V in high pressure die cast aluminum housing in polycarbonate cover with clear prismatic diffuser and lamp holders etc complete with all accessories connected with twin core twisted flexible copper wire of suitable size, complete all as specified & directed. Make: Crompton Cat Part No. LBHP-10-CDL or equivalent in models of Philips/Bajaj/Wipro/GE/Surya
Exhaust fans (metal body) AC single phase 230/ 240 V of size 300 mm sweep 900 RPM with louver including cutting of hole of adequate size including making good existing surfaces with and including fixing with MS fasnut all as specified and directed Make- Havells model Turbo Force or equivalent in Crompton/Bajaj
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, complete all as specified..
Buzzer, Ding Dong AC. 230 volts, single pole, complete all as specified and as directed.
Step type electronic regulator, flush type suitable for 1200mm / 1400mm sweep AC ceiling fan, complete all as specified and as directed.
Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed.
MCB SP 6 to 32 Amp 10 KA 240 Volts, 'C' Series, complete all as specified and as directed.
MCB SPN 40-63 Amp 10 KA 240 Volts, 'C' Series, complete all as specified and as directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 10 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
Earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire with Gi protection pipe upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
M/S DHARAM PAUL GUPTA
Bidder Name
M S BANSI LAL CONSTRUCTION CO
M/S DHARAM PAUL GUPTA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .