Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.9 LAccepted-AOC PLOT NO 59 60 WAZIDPUR JAIMAU KANPUR 208010 | KANPUR NAGAR | UTTAR PRADESH | 208010 | 1 | Accepted-AOC Being lowest and reasonable rates | |
| 2 | 2₹24.2 L+₹2.3 L (10.7%)Rejected-Finance | 2 | Rejected-Finance Not being a lowest tenderer |
Tender Value
₹24.2 L
EMD Value
₹48,480
Closing Date
13 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE U
HQ CWE U Delhi Cantt 110010
ADDN ALTN TO DSC MESS COOK HOUSE AND DINNING HALL AT DIPAC DELHI CANTT 10
2021_MES_488403_1
89036/CWE(U)/D-30/2021-22/E8
Open Tender
Construction Works
Item Rate
120 days
Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE(I) (U) B/R
₹48,480
Yes
6 Jan 2022
15 Nov 2021
15 Dec 2021
15 Nov 2021
13 Dec 2021
30 Nov 2021
60 days
Amount
B&R WORKS Excavation in trenches , not exc 1.5 m wide and n exc 1.50 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregates), as in foundation filling and mass concrete complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregates), as in floors complete all as specified and as directed.
M&L for RCC M-25 concrete using 20 mm graded stone aggregate as in foundation including rafts footings , foundations beams, plinth beams, bases for coulmns etc basement slab, undereamed piles and mass concerte all as specified and dirceted
M&L for RCC M-25 concrete using 20 mm graded stone aggregate as in column complete all as specified and dirceted
M&L for RCC M-25 concrete using 20 mm graded stone aggregate as in slabs , chajjas of any thickness above top of footing including attached pilasters and buttress complete all as specified and dirceted
M&L for RCC M-25 concrete using 20 mm graded stone aggregate as in beams complete all as specified and dirceted
M&L for Formwork to sides of flat concrete foundations, footings, bases of coullmns, raft and raft beams, sides and soffits of foundations and plinth beams and similar work complete all as specified and directed.
M&L Formwork to sides of pilars post, struts piers , coloumn and stanchion of square , rectunglar or polugonal shape for rough finished surface of concrete complete all as specified and directed.
M&L for Formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exc 200mm thick ( horizonla or sloping) for rough finished surface of concrete complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams , beam haunching girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
Returning , filling in incl spreading levelling and well ramming and watering in layers n exc 25 cm complete all as specified and directed.
Removing excavated material soil to a distance exc 250 m but not exc 500 m and deposited where directed complete all as specified and directed..
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
All as per item no 15 above but 5mm dia and over and upto and incl 10mm dia in stirrups spacers and binders complete all as specified and directed.
M&L hardcore of broken stone or boulders of guage n.exc 63 mm deposted, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as speciffied and directed.
M&L for cement concrete type C-1 (1:3:6) ( 20 mm graded aggregate) as in plinth protection complete all as specified and directed.
M&L Vitrified jointless Ceramic tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor laid over15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles complete all as specified and directed.
All as per item No 19 above but in dado & skirting over 10mm screed in CM 1:4
M&L for colour glazed ceramic tiles in dado & skirting 450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm double side prelam PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified.
S&F Factory Made Solid PVC Moulded Door Shutter with Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified.
S&F 100 mm long butt hinges medium weight mild steel alloy with galvanised .
S&F aluminium anodised 150 mm handles caste type complete all as specified.
S&F 300mm aluminium alloy anodised sliding door bolt with hasp and staple ( bolt type) and fixing clips of sheet cast of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed all as specified and directed
S&F aluminium anodised, barrel tower bolts of extruded section and length of bolt 200 mm complete all as specified.
S & F in repair 32mm dia aluminium powder coated drapery rod including all necessary fixing arrangement like clamps, end brackets, end to end bracket and eight nos rings per meter complete all as directed and specified.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius in cement mortar 1:6 complete all as specifed and directed
M&L for 15 mm thick rendering on fair faces or brick work or concrete in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces or brick work or concrete in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar 1:3 finished even and smooth without using extra cement on concrete surface in ceiling complete all as specified and directed.
M&L for 2 mm thick wall care putty over plastered surfaces to prepare the surface even and smooth complete all as specified and directed.
M&L for applying two coats of exterior dust proof paint (of approved quality & tint) on new surface of wall over one coat primer by spray painting, complete all as specified.
M&L for preparation of newly plastered surfaces of wall & apply two coats of oil bound distemper over 3mm thick wall care putty complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling & apply two coats of oil bound distemper over 3mm thick wall care putty complete all as specified and directed.
M&L for 10 mm thick plaster on concrete surface in CM 1:4 with WPC by weight of 3% of weight of cement complete all as specified and directed. Note : Integral water proofing compound shall be measured and paid for seperately under respective item of this BOQ.
Supply only integral water proofing compound complete all as specified and directed.
M&L for applying a tack coat of industrial bitumen 85/25 @ 1.20 Kg per sqm and including 3 mm thick (minimum) APP based polymeric membrance weighing not less that 3 Kg per sqm, reinforced with polyster non wove fabric ( wt not less than 150 gms/Sqm) laid on primed surface by forced application usinggas torch with an overlaping 100 mm on each side complete all as specified and directed.
S&F powder coated aluminium three track sliding windows with three sliding shutters (one gauzed shutter including 0.36mm dia and 1.18mm aperture stainless steel wire mesh and two glazed shutter including 4 mm thick plane glass panes) made of aluminium sections not less than 1.1kg per meter for bottom and top tracks, side track 0.98 kg per metre, bottom shutter frame 0.55 kg per metre, top shutter frame 0.47 kg per metre, shutter sides 0.47 kg per metre and interlock sides 0.45 kg per metre including suitable nylon beading, channel, gasket, nylon rollers, Maruthi lock with handles etc complete all as specified and directed.
S&F Powder coated aluminium doors using 96.6 mm X 44.8 mm X 1.60 mm aluminium chowkhat, with 84 mm X 44.7 mm X 1.60 mm section vertical stile, with 101.60 mm X 44.8 mm X 1.60 mm rail mounted on floor spring with mortice lock (Make- Harrison), with aluminium tower bolts 150 mm long (02 nos), sliding bolt 300 mm long (01 no), door handle 150 mm long (02 nos) and fittings all as directed by Engr-in-Charge. Bottom panel with 12 mm thick laminated nova pan and top panel with 5.5 mm thick plain/froasted sheet glass with rubber beading of suitable size, complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etccomplete all as specified and directed.
S&F PVC (SWR) pipes 75 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed .
S&F PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete all as specified and directed.
S&F PVC SWR bends 110 mm dia complete as specified and directed .
S&F PVC SWR bends 75 mm complete all as specified and directed.
S&F steel water tubing, galvanised, medium grade, ISI marked with and including all fittings and fixed on walls and ceilings or in floor bore of pipe 20mm complete all as specified and directed.
S&F steel water tubing, galvanised, medium grade, ISI marked with and including all fittings and fixed on walls and ceilings or in floor bore of pipe 15mm complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 litres all as specified in SSR Part-I complete all as specified and directed.
S&F in repair 15mm gate valves gun metal with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
S&F in repair 20mm gate valves gun metal with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
S&F in repairs bib taps, cast copper alloy, fancy type with crutchor butterfly handles, chromium plated, screwed down to iron pipes or for brass ferrule of 15mm bore complete all as specified and directed.
S&F in repairs angle valve ,stop valve, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed.
S&F in repairs two way stop valve cast copper alloy,fancy type, chromium plated, with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore complete all as specified and directed.
M&L for 20 mm thick granite stone (any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment (1:2) to match the shade of stone including cutting and polishing as in floors laid over 15mm thick screed bed in cement mortar 1:6 complete.on cooking / working platform complete all as specified and directed.
S&F in over counter wash basin oval shape size 590x420x195mm alongwith waste coupling 32mm size full thread with 130mm height complete as per manufacture's direction and as specified and directed.
S&F single lever basin mixer with popup waste with 450 mm long braided hoses complete all as per manufactures directions and as specified and directed.
S&F in repair 32 mm bore and 75 cm long pvc flexible waste pipe for WHB complete all as specified and as directed.
S & F in repairs towel rails chromium plated of 20mm dia and 600mm long complete all as specified and directed.
S&F CP grating 100mm dia complete all as specified and directed.
S & F repair CP towel ring of Make-AQN-7721 of Jaquar or equvelent. complete all as specified and directed.
S&F soap dispenser with Glass bottle complete all as per manufacturers direction and as specified and directed.
S & F repair CP Soap dish complete all as specified and directed.
ELECTRICAL (E&M) WORKS Point wiring using approved color coading as per IS (Red,Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area,single core,PVC insulated and sheathed FRLS cable 1100V grade,ISI-694 marked with valid CML no. in and including medium grade,PVC concealed conduit MMS, ISI marked of dia not less than 20mm and conduilt accessories concealed in wall/roof/floor etc.,ISI marked with valid CML No-(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with terminated to new pressed flush metal readily available cover with outer with plates inner plates etc, suitable for mounting modular type switches,sockets, fan regulators etc PVC insulated PVC insulated multistranded copper condutor 1.5 sqmm nominal cross section area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.. Note : Switches and socket to be measured and paid for separately for the following:-
One light point/one fan point controlled by one SP switch
One socket outlet 5 amps controlled by one switch on same board
One socket outlet 5pin,5/6 Amp On independent board
All as per item No. 65 above but point wiring with 2.5 SQMM single core multi sranted copper consductor PVC insulated and unsheathed (FRLS) cable 1100 volts grade and 2.5 SQMM PVC insulated and unsheathed (FRLS) cable 1100 volts grade with multistranded copper conductor as earth wire for 15/16 Amps multi purpose socket combination point on independent board.
S&F modular switch one module, 5/6 Amp, one way, 230 volts AC complete all as specified and directed.
S&F modular switch one module, 15/16 Amp, one way, 230 volts AC complete all as specified and as directed by Engr-in-Charge.
S&F modular socket two module outlet 5/6 amps, 2 in 1, 2 & 3 pin combined, 230 volts AC complete all as specified and as directed.
S&Fmodular socket out let two module, 2 in 1, 3 Pin suitable for 5/6 Amp and 3 Pin suitable 15/16 Amp combined, 230 volts AC complete all as specified and as directed.
S & F ceiling rose, 3 phase, PVC / polycarbonate, surface type, 65mm x 50mm, insulated body, three terminal complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completecomplete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm with louver shutter, 230 Volts AC 1400 RPM,Trouble free continuous operation, heavy duty motor necessary electrical connections from ceiling rose to fan with 23/0.0076 Three core PVC Flexible cable including of suitable hole made in wall to fix the exhust fan etc complete all as specified and directed.
S & F of MCB SPN metalic distribution board, SPN 12 way, 240 Volts AC, double door type of sheet steel phosphotised powder painted with 200 Amps, neutral bars, earth bar concealed flush in wallall as specified and directed.
Supply and fixing of MCB single pole and neutral, 240 volts, 63 amps breaking capacity 10KA, ‘C’ Series. etc , complete all as specified and directed.
Supply and fix MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts of galvanized iron or steel including 15mm dia GI pipe light grade upto 1.5 mtr below GL for protection pipe, excavation and earth work charcoal dust, common salt, PCC 1:3:6 type C-1 chamber with cover and RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both way with MS handle 12mm dia PGI funnel and wire mesh all as shown in electrical plate No 5 of SSR Part-I connected to ear thing test point all as specified or indicated including testing on completion all as directed.
Supply and laying or fixing or passing through existing duct/pipe, 1100 Volts grade heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and over all PVC sheathed 25 Sq mm 2 core nominal cross section stranded conductor complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with street light bracket made of GI pipe light grade 40mm dia upto 1.2 mtr length bend at an angle 120º for fixing with clamp to building wall complete all as specified and directed.
Supply and laying 40 mm bore GI tubing light grade, ISI marked, for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps,saddels etc all as directed and specified.
Supply only sheet metal enclosure single pole and neutral with two pin earth plug and socket complete with one single pole MCB 20 Amp 240 volts half grouting on wall all as specified and directed.
Supply and fixed LED recessed mounting square slim LED down lighter 36 Watt for AS/GB/POP ceiling 2'x2' size complete with internally prewired and connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed.
Material and Labour for sub main wiring complete with 2 single core multi stranded copper conductor 6 sqmm (Nominal area) PVC insulated unsheathed cable drawn in and including medium grade PVC conduit ISI Marked not less than 25 mm dia concealed, including making good distrubed surface, of wall, including single core multi stranded copper conductor 6.0 sqmm size as earth wire drawn in same conduit complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
garnet engineers contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .