Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | ₹16.7 L Quoted ₹17.2 L | L1 | Accepted-AOC aoc |
| 2 | L2₹19.3 L+₹2.1 L (12.0%)Rejected-Finance 28 AVANTIBAI MARKET MAKRONIA SAUGOR MP 470004 | SAUGOR | SAGAR | MP | 470004 | ₹19.3 L+₹2.1 L (12.0%) | L2 | Rejected-Finance 2nd lowest bid |
| 3 | L3₹19.8 L+₹2.6 L (15.2%)Rejected-Finance | ₹19.8 L+₹2.6 L (15.2%) | L3 | Rejected-Finance 3rd lowest bid |
| 4 | L4₹20.6 L+₹3.4 L (19.9%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | ₹20.6 L+₹3.4 L (19.9%) | L4 | Rejected-Finance 4th lowest bid |
Tender Value
₹20.3 L
EMD Value
₹41,000
Closing Date
12 Nov 2022, 6:00 pmClosed
GE SAUGOR
GE SAUGOR
PROVISION AND REALIGNMENT OF LT POLES, STREET LIGHTS AND ALLIED WORKS INCLUDING CERTAIN MINOR WORKS UNDER GE SAUGOR
2022_MES_558894_1
GE/SGR/TOK-49 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SAUGOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹41,000
Yes
21 Nov 2022
20 Oct 2022
14 Nov 2022
20 Oct 2022
12 Nov 2022
31 Oct 2022
Amount
Dismantling of ACSR conductors of any size complete all as specified and directed.
Dismantling earth wire and craddles complete of any size complete all as specified and directed.
Dismantling insulators any type any size complete all as specified and directed.
Dismantling cross arms of MS angle section etc complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm, 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sqmm, 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm, 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm, 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 4 core complete all as specified and directed..
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 2 core complete all as specified and directed..
Excavation in trenches in hard /dense soil not exceeding 1.5metre wide and not exceeding 1.5 metre in depth and getting out complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and exc 1.5m but not exc 3.0 m depth in any type of soil complete all as specified and directed.
M&L for sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete all as specified and directed. Note:- Punned thickness shall be measured and paid
M&L for sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed.
Returning filling in with excavated soil, including spreading, levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed.
Supplying, laying and fixing in position galvanized iron pipe 80mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed
Supplying, laying and fixing in position galvanized iron pipe 50mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed
Supplying, laying and fixing in position galvanized iron pipe 40mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed
Taking down and re-laying/re-routing of LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of any size laid in trenches or fixed on wall/floor/polesincluding taking out old unserviceable/ serviceable bricks, cable covers, GI pipe of any size for reuse from trenches for removing all as specified and directed
Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 400 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31) conforming to IS 2713 (part 1 to 3), 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed). Note: (a) Cost of numbering of pole shall be deemed to included in unit rate. (b) Excavation, Earth work and PCC foundation will be measured and paid for separately. (c) The pole shall be marked with designation, manufacturer's identification and year of manufacture
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 22) conforming to IS 2713 (part 1 to 3), 8.5 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed). Note: (a) Cost of numbering of pole shall be deemed to included in unit rate. (b) Excavation, Earth work and PCC foundation will be measured and paid for separately. (c) The pole shall be marked with designation, manufacturer's identification and year of manufacture
S&F new 40mm bore or next suitable size ( for LED fittings) light grade GI bracket 1.20 mtr long bent to shape by cutting welding and well finishing including MS clamp of flat iron of size 25x5mm of suitable length 2 Nos complete for steel tubular poles with nuts bolts and painting with two coats of aluminium paint over a coat of primer on MS clamp complete all as specified & directed.
Supply and fixing weather proof PVC Junction Box made out of not less than 2 mm thick of size 250x200x100 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 01 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers all as specified and directed . Note : The rate quoted shall include the cost of MS Clamps, bolts, nuts and washers
Taking down including shifting and re-fixing high performance LED street light fittings/luminaries of any size/capacity complete all as specified and directed.
S&F Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 40x40x6 mm thick grounting in floor , 0.45 mm depth grounting with PCC 1:3:6 upto ground level complete all as specified and directed.
S&F straight through cable joint suitable for LT armoured cables, PVC insulated, aluminium conductor, 1100 volts grade type for 16 to 35 Sqmm 3 ½ size type SLA – 4 complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip 25x4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron wire 4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified and directed.
M&L for boring of holes under road/railway crossing, pavement, hardstanding by means of mechanical earth auger complete all as specified and as directed.
S&F exhaust fans AC single phase 230/ 240 V of size 300mm sweep metallic body with all accessories including making hole in stone /brick wall grouting &making good in all aspects complete all as specified and directed. Make: -Bajaj Cat Part No.Frehee 300/CG Trans Air 12"/Havells Cat Part No.Venti Air-DX White
S&F exhaust fans AC single phase 230/ 240 V of size 250mm sweep PVC body with lovers complete all accessories including making hole in stone /brick wall grouting &making good in all aspects complete all as specified and directed. Make: -Havells Cat Part No Ventil Air -DX White/Bajaj Cat Part No. MAXIMA DX/Crompton Cat Part No.Ventilus10ʺ
M&L for point wiring for one light point or fan point controlled by one switch with 1.5 Sqmm PVC insulated FR, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green
S&F switch piano type flush, single pole, one way 5 A 230 V complete all as specified and directed.
S&F ceiling rose, surface backlite, three terminal complete all as specified and directed .
SHRI RAM ELECTRICALS ENTERPRISES
M/s ajeet enterprises
POONAM ELECTRIC INDUSTRY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .