Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42,821Accepted-AOC 2 JORA BAGAN STREET KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC L1 (Lowest Bidder) | |
| 2 | L2₹46,210+₹3,389 (7.91%)Rejected-Finance 114 3 HAZRA ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹48,330+₹5,509 (12.9%)Rejected-Finance 4 1D PADDAPUKUR ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹48,990+₹6,169 (14.4%)Rejected-Finance 48 2G B T ROAD KOLKATA 700050 | KOLKATA | KOLKATA | WEST BENGAL | 700050 | L4 | Rejected-Finance 4th Lowest |
Tender Value
Refer Docs
Closing Date
1 Aug 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE LBESD
81/2/2, Phears Lane, Civil Defence Building, Kolkata-700012
Urgent Repairing of Electrical Installation work in the Scaning room at Office of the Registrar General of Marriages, West Bengal at the 2nd floor of KIT Building, Kolkata 700073
2023_WBPWD_550385_1
WBPWD/AE/LBESD/eNIT-01 (2nd call) of 2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
KIT BUILDING
Please refer Tender documents.
6 documents required · 6 mandatory
28 Mar 2025
24 Jul 2023
4 Aug 2023
24 Jul 2023
1 Aug 2023
25 Jul 2023
Amount
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+12 way (Legrand-607710/Siemens-8GB32102RC14/ABB-SCHM12). (D-9/13).
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Legrand/Siemens/ABB) (D-5/6)
240 V, 40 A DP Isolator
Supplying and fixing following type MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/Siemens/ABB). (D-6/7)
240 V, 6-32 A SP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire( wire colour code mandatory)(Polycab/ Finolex/ Havells/RR Kabel)) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Havells-cabtree/Legrand-Myrious) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 10 mtr. (E-25/5e)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. ON BOARD (E-24/3a.)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. (E-16/7)
20 mm. size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.((Polycab/Havells/Finolex/RR Kabel) (E-9/1)
2 x 2.5 sqmm + 1 x 1.5 sqmm
2x 6 sqmm + 1x 4 sqmm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with switch (Havells-cabtree/Legrand-Myrious) - 3 set with 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with switch - 1 set, with Indicator without plug top & 1 no. 16 A. Modular type SP MCB on S&F 16/18 Module GI Modular type switch board flushed on wall with top cover plate flushed in wall incl. making necy. connections as per GS. [NS]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall as per GS. (E-4/11)
240 mm x 200 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws. (E-5/13)
240 mm x 200 mm x 65 mm
Supplying of Twin 4ft. LED Tube light with fitting complete with all accessories & 230 V. 20W. T-LED Tube. (Philips - TMC 501 P 2xT-LED 22W P3242 with two nos. LED tubes 20W B2B 865 T8/ CG - IGP162LT8-16 & 2 nos. LTT8-8/ Wipro). (N-S)
Supplying of single 4ft. LED Tube light with fitting complete with all accessories & 230 V. 20W. T-LED Tube.(Philips - TMC 501 P 1xT-LED 22W P3241 with one no. LED tubes 20W B2B 865 T8 / CG - IGP161LT8-16 & 1 no. LTT8-8/Wipro).(N-S)
Fixing only Single/Twin tube light with fitting complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp as per G.S. (C-2/17)
Supplying of 1200 mm dia AC ceiling fan with complete accessories like blades, canopy, fork, rubber bush etc. (Orient /Usha stricker/ Crompton- Aura metalic).(N-S)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. (C-3/21-a)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. (E-18/10)
NEW INDIA ELECTRICAL AND ENGINEERING WORKS
BHARAT ELECTRIC
ASIAN ELECTRICAL & ENGINEERING WORKS
technical_1144985.pdf
PDF • 0.64 MB
techsummary_1144985.pdf
PDF • 0.13 MB
finance_1144985.pdf
PDF • 0.74 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1144985.pdf
PDF • 0.83 MB
eNIQ-01of23-24.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .