Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC 11 A KUTCHERY ROAD BALUGANJ AGRA 282001 UP | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹49.5 L+₹2.0 L (4.22%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹49.6 L+₹2.1 L (4.50%)Rejected-AOC | L3 | Rejected-AOC REJECTED |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
30 Aug 2021, 6:00 pmClosed
GE (NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
PROVISION OF CENTRALIZED HOT WATER SUPPLY IN INLIVING SAILORS BLOCK NO P 106 AND PROVISION OF SEPTIC TANK AND REPAIRS TO SEWAGE LINE AT KV STAFF QUARTERS ANDINSAILORS MARRIED ACCN AT INS HAMLA UNDER GE(NW) BHANDUP
2021_MES_458655_2
8137/E8
Open Tender
Civil Works
Item Rate
180 days
HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NW BHANDUP
₹84,000
Yes
20 May 2022
30 Jul 2021
31 Aug 2021
30 Jul 2021
30 Aug 2021
16 Aug 2021
Amount
Supply Installation Testing and commsissioning of commercial Heat pump water heater(HPWH) of water circulating type system working with input electric power single phase supply 230 Volts,50 Hz , 2.74 KW Electrical Heating input capacity at 25° C and produces average Electrical Heating output 10.7 KW at 55 ° C Temperature for generate hot water along with Smart Digital Display Controller for each pump with Required length of control cable run from Heat pump machine to Smart digital controllers as specified and directed by the Engineer-in-Charge.The warrenty period shall be minimum of 02 Years on heat pump water heater. Make : Racold Model No. R HPWH 11 SP of or Any other equivalent specifications of /Jaquar/A.O.Smith model No. AWH-35 as approved by the GE.
Supply and install 1500 Ltrs storage capacity made with Stainless steel tank non pressurized(Equivalent Make of Heat Pump only) including Supporting accessiories. as specified and directed by the Engr-in-Charge. Note : The Installation of the Heat pump water heater and Storage tank should be as per Company Manual Instructions With Company's authorised service person only.The warranty period shall be minimum of 02 Years on Storage Tank.
Supply and Fix Safety pressure relief Valve size 15 mm dia for water heater of specified make specified complete all as directed by engr in charge
Supply & Fix Immersion type Stainless steel ISI approved Sensor Pockets for measuring water temperature in Hot water storage tank complete all as specified and directed by engr in charge
Supply & Fix Dial Type thermometers for the temperature range upto 0- 100° C suitable for 2 inch bore pipe complete all as specified and directed by engr in charge
Supply,Install,Testing & Commissioning of single phase 230 V 0.75-1 H.P Capacity water Pump with flow rate min 3000 LPH With MNX 12A Contactor without starter direct connected to Heat pump complete all as specified and directed by engr in charge
Supply & Fix Brass made Ball valve 25 mm dia. (Locations : Hot water storage tanks inlet and outlet - 8 Nos and for heat pump and circulating pumps inlet and outlet -08 Nos) complete all as specified and directed by engr in charge
Supply & Fix Brass made NRV 25 mm Dia for Tank.(Locations : Hot water storage tanks inlet and outlet - 2 Nos and for heat pump and circulating pumps inlet and outlet -04 Nos) complete all as specified and directed by engr in charge
Supply & Fix made brass Y-Strainer screwed type - 25 mm dia complete all as specified and directed by engr in charge
Supply & Fix UPVC Pipe For Cold Water 32 mm dia with fittings on walls/ceiling or laying in floors complete all as specified and directed by the Engineer-in-Charge .
Supplying and laying of 25 mm Dia CPVC pipes SDR 11 withstand temperature rating upto 83°C & Plain CPVC SDR fittings on walls/ceiling or laying in floors complete all as specified and directed by the Engineer-in-Charge (for Plumping requires between Hot water storage tank and circulation pump)
Supplying and laying of 32 mm Dia CPVC pipes SDR 11 withstand temperature rating upto 83°C & Plain CPVC SDR fittings on walls/ceiling or laying in floors complete all as specified and directed by the Engineer-in-Charge (for Down Take).
Supplying and laying of 20 mm Dia CPVC pipes SDR 11 withstand temperature rating upto 83°C & Plain CPVC SDR fittings on walls/ceiling or laying in floors complete all as specified and directed by the Engineer-in-Charge (for Down Take).
Supply & Fix Chrome plated(CP) Bib taps fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for the bore 20mm all as specified and directed bi Engr In charge .
M&L for sub main wiring complete two run of size 4.0 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn in only PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 4.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Two run 4 Sqmm PVC cable and one run of 4 sq mm PVC cable and Casing Caping will be measured as "one unit"length.
M&L for sub main wiring complete two run of size 6.0 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn in only PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 4.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Two run 6 Sqmm PVC cable and one run of 4 sq mm PVC cable and Casing Caping will be measured as "one unit"length.
Supply & fix sheet metal enclosure powder coated for MCB DB SPN 8 way double door with din rail and 200A rated bus bar including making good to the disurbed surface matching with the existing complete all as specified and directed.
Supply and fix MCB SPN 240 volts 63 Amps with breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SP 240 volts 6-32 Amps with breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI galvanised iron strip size 25 x 4 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 3connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
S & F Earth continuity conductor GI Galvanised iron strip size 25 x 4 mm or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by engr in charge
Cleaning existing drainage / culverts of any depth including removing cover slabs/grill , soils , spoils , vegetation , silt etc and refixing/placing of removed cover slabs/grill including making good in cement mortar 1: 6 and removing material outside the MD land complete all as directed and specified.
Excavating over areas n exc 1.5 m deep and getting out in hard / dense soil, all as complete specified and directed .
M & L for pre cast RCC septic tank having buffer wall separating primary and secondary sedimentation effluents , for 100 Nos of users , having diameter of 1800mm and length 2500 mm including connection to manhole at intet and outlet to soak pit as directed by Engr-In-Charge.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m indepth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil all as specified and directed.
Demolition and breaking up drain pipes (salt ware,AC, or reinforced concrete set in cement mortar internal dia of pipe 150 mm all as specified and directed
Demolition and breaking up drain pipes (salt ware,AC, or reinforced concrete set in cement mortar internal dia of pipe 200 mm all as specified and directed
M & L for concrete bed to drain pipes including packing and haunching against the sides of pipes with concrete after they are laid and tested for 150mm dia pipe with cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate ) all as specified and directed.
M & L for concrete bed to drain pipes including packing and haunching against the sides of pipes with concrete after they are laid and tested for 200mm dia pipe with cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate ) all as specified and directed.
M & L for Salt glazed stone ware drain pipes 150 mm dia conforming to IS grade 'A' laid in trenches and jointed as specified and directed.
M & L for Salt glazed stone ware drain pipes 200 mm dia conforming to IS grade 'A' laid in trenches and jointed as specified and directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard dense soil all as specified and directed .
Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point all as specified and directed .
M & L for demolition of brickwork or stone/ boulder masonry, built in cement mortar including coping including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed
M&L for brick work with subclass B brick straight or curved on plan exc. 6m mean radius , built in cement mortar 1:4 all as specified and directed .
M& L for 15mm thick rendering(first coat) in CM 1:4 on external surface of wall mixed with water proofing compound and shall be scored to provide key for finishing coat including necessary scaffoldings etc complete all as specified and directed
Supply only integral water proofing compound
Taking down cast iron soil waste pipe (any size or patterns) moulding all fittings heads, shoes, bends etc. (Measured over all as fixed along the confrce line over fittings and accessories) complete all as specified and directed .
S&F 100mm bore sand cast CI soil, vent, and waste pipes in any length with or without ears with cement joints fixed to wall with Stack clamps out of 50 mm by 5 mm flat iron and 12mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof. (Note : - The rate inclusive of scaffolding upto 6th floor.) complete all as specified and directed
S&F CI bend of any radius with oval access door 100mm bore diminshing pieces or tapers on walls complete all as specified and directed
S&F CI branch pieces, single (equal or unequal) 100 mm bore with oval access door complete all as specified and directed
S & F 160mm dia PVC rain water pipe single socketed (ISI marked) fixed to wall with mild steel clamps including complete fittings such as heads, bends, shoes, swan necks etc complete all as specified and directed
M & L for Bioclean Septic Tank Cleaner includes biological blend of organic microbes that maximizes degradation of faecal sludge. This will recharges tank with beneficial bacteria and maintains a clean and odour free septic tank .Make :- Organica biotech or equivalent.
M&L for precast RCC 1 : 1.5 : 3 type A1 (using 20mm graded stone aggregate) in cover slab and set in CM 1 : 4 including necessary form work complete all as specified and directed .
M & L for hard core of broken stone or boulder of guage not exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick watered & rammed to a true surfaces complete all as specified and directed .
M&L for 75 mm thick PCC 1:3:6 type C-1 (20mm graded agg) as in sub base flooring and similar works finished even & fair without using extra cement complete all as specified and directed .
M&L for Machine pressed precast coloured glazed concrete interlocking paver block with grey cement & pigment, glossy finish (reflective type) as approved by GE) confirming to IS 15658-2006 of 100 mm thickness, M-35 Grade, as in pavements to required level & gradients, set, jointed with clean dry sand and sealing the ends using PCC 1:2:4 etc complete all as specified and directed .
M & L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed.
Demolition of concrete in ground floors (un reinforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for providing plain cement concrete 1:2:4 type B-1using (20mm graded stone aggregate) as in kerb stone coping including framed work for man holes etc including weathering ,slightly rounded or chamfered angle and throating,including necessary form work complete all as specifed and directed
Demolition of RCC of any description and in any position of nexc 15cm thickness not otherwise specifically provided reinforced (reinforcement of cut as required to facilitate demolition etc) including removal of demolished materials out side of MD land complete all as specifed and directed.
M&L for precast reinforced concrete type B-1 1:2:4(20mm graded aggregates) set in cement mortar 1:4 as in cover slabs complete all as specified and directed
M &L for TMT bars 5mm dia and over upto 10 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M &L for round bars confirming to Fe 290 GDE E-165pf 12 mm dia for handles , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Cutting to existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for internal dia of pipe 150mm complete all as specified and directed.
Provision of one soakage well of 3 m dia and 6.0 m effective depth with following specification, soakage well excavation in any type of soil and PCC foundation in 1:3:6, wall of honey combing with top rings of M25 concrete including intercepting chamber and screen chamber made of brick masonery in CM 1:6, RCC cover slab in M-25/ SFRC cover interconnecting pipes of RCC/DWC complete filled with brick bats all as specified and directed and as shown in TD drawing No. WD/2007/01 (A)
M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs all as specified of 5000 ltrs capacity complete all as specified and directed. Make sintex
M&L in repairs Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete 25mm dia complete all as specified and directed.
M&L Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 25mm bore dia complete all as specified and directed
Dismantling carefully RCC work as in, Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended worketc by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of debris out side the MOD land. complete all as specified and directed.
M & L for Excavation over areas exc 1.5m deep but n exc 3.00 m deep and getting out in hard / dense soil complete all as specified and directed.
M &L for precast cement concrete block masonary with solid blocks with Type C1 ( 1:3:6 ) exc 10cm in width and setting in mortar 1:6 complete all as specified and directed.
M &L for precast cement concrete block masonary with solid blocks with Type C1 ( 1:3:6 ) exc 10cm in width and setting in mortar 1:6 complete all as specified and directed.
M & L for RCC M 30 Design mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and directed.
M & L for Use and waste of form work to sides or faces of concrete walls, retaining walls, abutments, parapets and similar work uncluding attached pillasters for flat and rough surfaces complete all as specified and directed.
M & L TMT bars 10mm dia and over cut to length, bent to shape reqd, inculding cranking,bending spirally for hooping for Columns, hooking ends and binding with and incl MS wire(annealed) not less than .90mm dia complete all as specified and directed.
S& F RCC pipes 150 mm bore , class NP-2, laid and jointed complete with collars complete all as specified and directed.
M & L for Framed work as in doors or gates of angle, handles or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S & F of Cast iron soil, waste and vent pipes incl cowl 100 mm dia , in any length with or without ears with cement joints, laid in trenches or in floors
Deduct Credit for Demolished/ Dismantled material Rs. (-) 27,750.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
M/s A G POUL
M/S VISHRANTA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .