Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAdmitted-Finance PANDADESWAR BARDHAMAN 713346 WEST BENGAL INDIA | PANDAVESWAR | BARDHAMAN | WEST BENGAL | 713346 | ₹7.8 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical KUNUSTORIA WEST BURDWAN PASCHIM WEST BURDWAN 713302 WEST BENGAL INDIA | KUNUSTORIA | PASCHIM WEST BURDWAN | WEST BENGAL | 713302 | - | - | Rejected-Technical TC recommendation |
| 3 | Rejected-Technical | - | - | Rejected-Technical TC recommendation |
| 4 | Rejected-Technical 59 R G S ROAD USHAGRAM DURGAMANDIR ASANSOL BARDHAMAN 713303 WEST BENGAL INDIA | ASANSOL | BARDHAMAN | WEST BENGAL | 713303 | - | - | Rejected-Technical TC recommendation |
| Sl No | Description | Qty | Unit | BENGAL ELECTRICAL ENTERPRISE L1 |
|---|---|---|---|---|
| 1.00Discription of items | ||||
| 2.00 | Supply, fabrication & fixing of MS Angle for 1 Cable Support in transformer and Vacuum Circult breaker etc. size-65*65*6 mm | 135 | Kg | 90 ₹12,150 |
| 3.00 | Supply, fabrication & fixing of MS Flat for Cable Support in transformer and Vacuum Circuit breaker Size-65x6mm | 55 | Kg | 110 ₹6,050 |
| 4.00 | Supply, fabrication, welding & erection of 50x6mm Gt flat for Equipment earthing connection to Earth pits and Equipment to Equipment, it shall comply with 15: 280-2006 with the latest amendments and galvanising shall comply with 15:4826-1979 with the latest amendments. | 325 | Kg | 115 ₹37,375 |
| 5.00 | Supply & jointing of outdoor type heat shrink 4 joint kit 11KV grade 120/150sq.mm. cable as per IEEE 48 standard with insulating material | 4 | No | 10,500 ₹42,000 |
| 6.00 | Supply and crimping of 150/120 sqmm electroplated copper terminal lug heavy duty as per DIN46235 | 75 | Nos | 580 ₹43,500 |
| 7.00 | Supply & fitting of flexible right angle Terminal boot outdoor type bushing, Max System Voltage 22kV(Umax24kV), Basic impulse level 125kV, Tensile strength 11N/sqmm, Temp -40 to 130 deg cent., Dielectric strength 15kV/mm(min) for transformer bushings (Incoming, Outgoing and Neutral) | 21 | Set | 4,200 ₹88,200 |
| 8.00 | Supply & jointing of indoor type heat shrink joint 7 kit 11KV grade for 5/70sq.mm. cable as per IEEE 48 standard with insulating material | 22 | No | 6,700 ₹1.5 L |
| 9.00 | Supply & fixing of busbar insulator as per IS 731(1971) for G.I. flat laying | 21 | No | 180 ₹3,780 |
| 10.00 | Transportation, earth cutting, covering, laying and installation of 120sqmm/150sq.mm PVC 9 insulated copper cable from OH to switch, transformer to primary and secondary breaker, Breaker bus coupling etc | 200 | Mtrs | 190 ₹38,000 |
Updated dates
Tender Value
₹10.8 L
EMD Value
₹13,600
Closing Date
11 Mar 2026, 9:00 amClosed
General Manager Bankola Area
Office of The General Manager Bankola Area, PIN-713363
Installation and commissioning of 3x2MVA 11kV/3.3kV Substation with Earthing and cable connections at Shyamsundarpur colliery under Bankola area
2026_ECL_354445_1
ECL/GM/BA/E TENDER/25-26/ENM/273 Dt 25.02.2026
Open Tender
Electrical and Maintenance Works
15 days
Shyamsundarpur Colliery
Please refer Tender documents.
5 documents required · 5 mandatory
₹13,600
8 Apr 2026
25 Feb 2026
13 Mar 2026
25 Feb 2026
11 Mar 2026
25 Feb 2026
25 Feb 2026 - 28 Feb 2026
Discription of items
Supply, fabrication & fixing of MS Angle for 1 Cable Support in transformer and Vacuum Circult breaker etc. size-65*65*6 mm
Supply, fabrication & fixing of MS Flat for Cable Support in transformer and Vacuum Circuit breaker Size-65x6mm
Supply, fabrication, welding & erection of 50x6mm Gt flat for Equipment earthing connection to Earth pits and Equipment to Equipment, it shall comply with 15: 280-2006 with the latest amendments and galvanising shall comply with 15:4826-1979 with the latest amendments.
Supply & jointing of outdoor type heat shrink 4 joint kit 11KV grade 120/150sq.mm. cable as per IEEE 48 standard with insulating material
Supply and crimping of 150/120 sqmm electroplated copper terminal lug heavy duty as per DIN46235
Supply & fitting of flexible right angle Terminal boot outdoor type bushing, Max System Voltage 22kV(Umax24kV), Basic impulse level 125kV, Tensile strength 11N/sqmm, Temp -40 to 130 deg cent., Dielectric strength 15kV/mm(min) for transformer bushings (Incoming, Outgoing and Neutral)
Supply & jointing of indoor type heat shrink joint 7 kit 11KV grade for 5/70sq.mm. cable as per IEEE 48 standard with insulating material
Supply & fixing of busbar insulator as per IS 731(1971) for G.I. flat laying
Transportation, earth cutting, covering, laying and installation of 120sqmm/150sq.mm PVC 9 insulated copper cable from OH to switch, transformer to primary and secondary breaker, Breaker bus coupling etc
Making of earth pit by 2no Gl pipe, 2no earth spike, 2kg 6swg cu. Wire, Gl clamp, bentonite soil 10bag, salt 1bag, etc. for Transformers double neutral, body earthing, 11kV and 3.3kV body earthing, Capacitor bank body earthing
Brick work of earth pit by Kilburn brick,cement,sand&making plastering
Loading, Unloading, Transportation, Placing, testing, connection and commissioning of 12 11kV/3.3kV 2000KVA Power transformer at CHP sub-station with sundries by Vehicles, man power & hydra.
Loading, Unloading, Transportation, Placing, testing, connection and commissioning of 11kV 13 and 3.3kV Vacuum Circuit breakers at CHP sub-station with related sundries by Vehicles, man power & hydra
CMPF cost (limited to the amount paid as per labour payment certificate)
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_367270.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Tendernotice_1.pdf
PDF • 0.85 MB
Tendernotice_2.pdf
PDF • 1.20 MB
Tendernotice_3.pdf
PDF • 0.16 MB
BOQ_367270.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid