Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.2 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹47.6 L+₹23,258 (0.49%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 BIDDER | |
| 3 | L3₹47.8 L+₹45,546 (0.96%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 BIDDER | |
| 4 | L4₹48.1 L+₹73,114 (1.55%)Rejected-Finance PO PS RUPA DIST WEST KAMENG ARUNACHAL PRADESH PIN 790 003 | WEST KAMENG | ARUNACHAL PRADESH | 790003 | L4 | Rejected-Finance REJECTED DUE TO L4 BIDDER | |
| 5 | L5₹48.3 L+₹95,262 (2.01%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Oct 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MOHAN SINGH YADAV, IDSE
GE TENGA
REPAIR/REPLACEMENT OF SECURITY/AREA LIGHTS POLES TIMER SWITCHES JUNCTION BOXES CONNECTION CABLES ALLIED WORKS AT PHASE III UL DAHUNG DUM DUM NALA MH MES OFFICES AND MESS OF AGE E/M UNDER GE TENGA
2024_MES_677305_1
8646/E8
Open Tender
Civil Works
Item Rate
270 days
TENGA VALLEY
PL REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE TENGA
₹90,000
Yes
16 Dec 2024
30 Sept 2024
22 Oct 2024
30 Sept 2024
21 Oct 2024
14 Oct 2024
Amount
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 16 sqmm 4 core including taking down of old unserviceable UG cable/service wires.
Description all as per item No 01 above but of size 16 Sqmm 2 core
Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
S&F in replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacitywith 6 Amp MCB single pole , of minimum size 300x200x105mm, fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps complete all as directed. . Make- Sintex/Supreme/Hensal
S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 32 mm dia, medium grade, 1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed.
M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35/45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity as specified and directed.
Description all as per item No 06 above but of capacity 60 Watt
Description all as per item No 06 above but of capacity 90 Watt
M&L for replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 70 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity all as specified and directed.
Description all as per item No 09 above but of capacity 200 Watt
S&F in replacement of battery 12 volt lead acid suitable for solar street light having capacity 150 AH including all fitting arrangements all as specified & directed. Make:- Exide/Amaron/Luminous
S&F in replacement of battery 12 volt lead acid suitable for solar street light having capacity 120 AH including all fitting arrangements all as specified & directed. Make:- Exide/Amaron/Luminous
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with two coats of aluminium paint over one coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 4 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections complete all as specified and as directed
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 10 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections complete all as specified and as directed
Supply , fixing and testing of 3 phase automatic street light switch using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress three phase 12 KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB (3 Nos) rating 40 Amps (b).Contactor MCB (3 Nos) rating 40 Amps (c).Out put MCB (3 Nos) rating 40 Amps (d).Three phase circuit wiring minimum 10 Sqmm multistranded copper wire. Make & Model -SWADEEP -02EC 12 KW3P of Kakatiya Energy Systems Ltd
Supply & fixing of single phase automatic street light switch using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress single phase 8KW lightning load capacity including mounting bracket , cable glands, front openable doors fitted with hinges & locking arrangment complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 8 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 40 Amps (b).Contactor MCB rating 40 Amps (c).Out put MCB rating 40 Amps (d).Single phase circuit wiring minimum 10 Sqmm multistranded copper wire. (e)Model No :- SWADEEP -02EC 5 KW1P. Make :- Kakatiya Energy Systems Ltd
M&L PCC in mix 1:4:8 type D2 with 40 mm graded aggregate for poles / filling in mass concrete
M&L for PCC 1:3:6 Type C2 for erection of pole in base with 40 mm gradede coarse agreegete complete all as specified and as directed.
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out soft & loose soil complete all as specified and as directed.
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 3 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out soft & loose soil complete all as specified and as directed.
Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete casted with PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregateall as specified and directed
M&L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying GI/PPR pipe after laying GI pipe trenches will be filled up to road level with 15cm PCC 1:3:6 type C1 using 20mm grade stone aggregate over 15cm 63mm gauge boulders over 15cm 100mm size boulders over rammed/compacted earth all as per specified and directed by Engr-in-Charge.
M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for pump house/gates of installations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc) all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
M&L for chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc.
S&F mild steel screw bolt (mechine made) with hexagonal or square, head, n.exc 5 cm but n.ecx 10 cm dia.
M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as directed.
S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed. Note - Each line of horizontal/vertical/diagonal wire to be measured for purpose of payment.
M&L MS angles as fencing port, struct cutting tops in shape incl all necessary drilling, notching and reveting etc and similar work confirming fe 310-0 pr fe 4120-0 all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
M/S SM ANSARI (BID ID -3143204)
D.P. Traders (BID ID -3143225)
M/S R D TRADERS (BID ID -3143246)
M/S SUNRISE CONSTRUCTION AND CO (BID ID -3143288)
M/S MURPHEW ENTERPRISES (BID ID -3143305)
M/S SARAI SUPPLY SYNDICATE (BID ID -3143324)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .