Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.8 L+₹55,840 (2.05%)Rejected-Finance 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.0 L+₹3.8 L (13.9%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
5 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
GE Alwar
REPAIR/MAINT OF DESERT COOLERS, ACS, COOLING APPLIANCES, INTERNAL ELECT, WELCOME MAINT AND MISC ITEMS AT OFFRS MD ACCN UNDER GE ALWAR
2022_MES_506036_1
8067/E8
Open Tender
Civil Works
Item Rate
210 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹68,000
Yes
31 Mar 2022
5 Feb 2022
7 Mar 2022
5 Feb 2022
5 Mar 2022
19 Feb 2022
5 Feb 2022 - 18 Feb 2022
60 days
Amount
M&L for servicing of split type AC of capacity 1.5/2 TR of any make by opening of condenser unit fixed on roof top and cooling unit fixed inside the builing, cleaning condenser unit and cooling unit including fins, checking /testing of all parts for its serviceability, oiling / greasing of motors, replacing worn out bushes, rectification of unusual noise, checking of refrigerent standing pressure, topping up of refrigerent upto the required level, replacement of minor parts such as nut/bolt/washer etc and reassembling of complete unit including testing for smooth functioning complete all as specified and directed.
M&L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter of front side by removing dust, cleaning the condenser including fins, checking /testing of all parts for its serviceability, oiling / greasing to condenser cum blower fan motors, replacing worn out bushes, rectification of unusual noise, checking of refrigerent standing pressure, topping up of refrigerent upto the required level, replacement of minor parts such as nut/bolt/washer etc and reassembling of complete unit including testing for smooth functioning complete all as specified and directed.
M&L for painting to desert cooler of any size complete after scrapping of old painted surfaces, removing the scaling etc and preparing the surfaces and painting with one coat of smoke grey synthetic enamel paint by spray painting on outer all sides of body and painting with rubber paint on inside surfaces of cooler tank and body including replacement of wood wool pad of suitable size complete all as directed by Engineer-in-charge.
M&L for cutting of venturing tubes, flushing out the gas circulating system, vaporation coil & conditioning coil etc, testing and rectification of leakage in system, gas charging with R-12 / R-22 / R-134a refrigerant for refrigerator of any make of 286/300/310 ltr capacity and testing for satisfactory working condition complete all as directed.
M&L for cutting of venturing tubes, flushing out the gas circulating system, vaporation coil & conditioning coil etc, testing and rectification of leakage in system, gas charging with R-12/R-22 refrigerant for water cooler of any make of 40/80 ltr capacity and testing for satisfactory working condition complete all as directed.
M&L for cutting of venturing tubes, flushing out the gas circulating system, vaporation coil & conditioning coil etc, testing and rectification of leakage in system, gas charging with R-12/R-22 refrigerant for water cooler of any make of 150 ltr capacity and testing for satisfactory working condition complete all as directed.
M&L for cutting of venturing tubes, flushing out the gas circulating system, vaporation coil & conditioning coil etc, testing and rectification of leakage in system, gas charging with R-22 refrigerant for window type air conditioner 1.5 / 2 TR capacity of any make and testing for satisfactory working condition complete all as directed.
M&L for cutting of venturing tubes, flushing out the gas circulating system, vaporation coil & conditioning coil etc, testing and rectification of leakage in system, gas charging with R-22 refrigerant for split type air conditioner 1.5 / 2 TR capacity of any make and testing for satisfactory working condition complete all as directed.
M&L for cutting of venturing tubes, flushing out the gas circulating system, vaporation coil & conditioning coil etc, testing and rectification of leakage in system, gas charging with R-12/R-134a refrigerant for deep freezer (horizontal chest freezer) of any make of 210/320 ltr capacity and testing for satisfactory working condition complete all as directed.
M&L for repair to window type air conditioner 1.5 TR capacity by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vaccumising the system and charging with R-22 gas, installation, testing to desired temperature and spray painting with one coat of synthetic enamel paint (white) and testing complete all as directed by Engineer-in-charge.
All as per serial item No. 10.00 here-in-before but of capacity 2.0 TR.
M&L for repair to split type air conditioner 1.5 TR capacity by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vaccumising the system and charging with R-22 gas, installation, testing to desired temperature and spray painting with one coat of synthetic enamel paint (white) and testing complete all as directed by Engineer-in-charge.
All as per serial item No. 12.00 here-in-before but of capacity 2.0 TR.
M&L for repair to water cooler 40 Ltr capacity Make- Usha/Blue star/Sidwal by taking out existing unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat, vaccumising the system, gas charging with R-12/R-22 gas and spray painting with one coat of synthetic enamel paint (smoke grey) and testing complete all as directed by Engineer-in-charge.
All as per serial item No. 14.00 here-in-before but 150 Ltr capacity.
M&L for repair to refrigerator of make Kelvinator / LG / Godrej / Whirlpool /Samsung of capacity 165 ltr / 286 ltr / 300 ltr / 310 ltr by taking out old unserviceable compressor unit and replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat and gas charging in system with R-12 / R-22 / R-134a gas & testing complete and spray painting with one coat of synthetic enamel paint of approved shade/tint all as directed by Engineer-in-charge.
M&L for repair to Deep Freezer any make and 320 ltr capacity by taking out old unserviceable compressor unit, replacing it with new sealed compressor of same capacity from authorised dealer of the manufacturer alongwith relay, OLP and thermostat and gas charging in system with R-12/R-22/R-134a gas & testing complete and spray painting with one coat of synthetic enamel paint of approved shade/tint all as directed by Engineer-in-charge.
S&F condenser fan motor 1/35 HP suitable for water cooler Make - Annupurna or ISI marked including taking down existing unserviceable condenser fan motor complete all as directed by Engineer-in-charge.
S&F Cooler fan motor complete 20" sweep 900 RPM, 230 Volt, 50 C/S with blade of Make - Khaitan / Usha /Havells including taking down existing unserviceable fan motor complete all as directed by Engineer-in-charge.
S&F condenser fan motor for Window type AC 1.5 TR Capacity, double shaft, 880 RPM, 1/6 HP, ISI marked including taking down existing fan motor all as directed by Engineer-in-charge.
S&F condenser fan motor for Window type AC 2 TR Capacity, double shaft, 1400 RPM, 1/6 HP, ISI marked including taking down existing fan motor all as directed by Engineer-in-charge.
S&F condenser fan motor for Split type AC 1.5 TR Capacity, single shaft, 880 RPM, 1/6 HP, ISI marked including taking down existing fan motor all as directed by Engineer-in-charge.
S&F condenser fan motor for Split type AC 2 TR Capacity, single shaft, 1400 RPM, 1/6 HP, ISI marked including taking down existing fan motor all as directed by Engineer-in-charge.
S&F Fan blower cooling motor for Split type AC 1.5/2 TR Capacity, single shaft, 1400 RPM, 1/6 HP, ISI marked including taking down existing cooling motor all as directed by Engineer-in-charge.
S&F copper tube suitable for Split type AC 1.5 / 2 TR Capacity including taking down existing copper tube all as directed by Engineer-in-charge.
S&F condenser assembly in water cooler of any make of capacity 40/150 ltr including taking out old unserviceable assembly all as directed by Engineer-in-charge.
S&F condenser assembly in refrigerator of any make of capacity 180/260/310 ltr including taking out old unserviceable assembly all as directed by Engineer-in-charge.
S&F condenser assembly in Window AC of any make of capacity 1.5/2 TR including taking out old unserviceable assembly all as directed by Engineer-in-charge.
S&F condenser assembly in Split AC of any make of capacity 1.5/2 TR including taking out old unserviceable assembly all as directed by Engineer-in-charge.
S&F in repairs freezer chest with door in refrigerator of capacity 300 lit / 286 lit.
S&F in repairs Filter panel (side/back panel) made of 0.80 mm thick galvanized steel sheet (ISI marked having zinc coating not less than 100 gms/sqm conforming to IS : 277) with & including internal surfaces painted with water resistant paint conforming to IS: 9862 and outer surface spray painted with synthetic enamel paint of approved shade/tint.
S&F plug top 3 pin 5/6 Amp 230 volt AC, ISI marked, complete, fixed in repairs.
S&F plug top 3 pin 15/16 Amp 230 volt AC, ISI marked, complete, fixed in repairs.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp, 240 Volt, complete, fixed in repairs. Make : Legrand / Havells / ABB
S&F sleeve foam protection suitable for split AC 1.5/2 TR complete all as specified and directed.
S&F in repairs factory made PVC drain pipe suitable for Split type AC 1.5/2 TR with coupler joint complete all as specified and directed.
S&F in repairs drain out pipe of split type AC 1.5/2 TR of PVC, heavy duty 15 mm dia and 1.5 mm wall thickness complete all as specified and directed.
S&F in repairs aluminium fan blade suitable for condenser of window type AC /Split type AC of any capacity complete all as specified and directed.
S&F in repairs PVC fan blade suitable for condenser of window type AC /Split type AC of any capacity complete all as specified and directed.
S&F in repairs PVC fan blower of cooling side for suitable for window type AC of any type complete all as specified and directed.
S&F in repairs cooling coil suitable for window type AC of capacity 1.5/2 TR complete all as specified and directed.
S&F in repairs metal clad top plug of capacity 20 Amp complete all as specified and directed. Make : Havells / Legrand / Standard as approved by GE.
S&F in repairs metal clad socket of capacity 20 Amp complete all as specified and directed. Make : Havells / Legrand / Standard as approved by GE.
M&L for painting and marking on appliances with SM No/MES No of size 80mm x 30mm as directed by Engineer in Charge.
S&F in repairs wire remote control (Micro processor) unit suitable for Split type AC 1.5/2 TR capacity complete with wires of remote all as specified and directed.
Supply & fixing in repairs the following accessories/spares for refrigerators :-
Starting relay 1/8 HP
Ice Tray PVC for 165/286/300/310 ltr refrigerator
Baffle tray for 300/310/320 ltr cap refrigerator
Baffle tray for 286/295 ltr cap refrigerator
Crysper tray with glass for 310/320 ltr cap refrigerator
Crysper tray with glass for 286/295 ltr cap refrigerator
Defrost timer for double door refrigerator 295/300/310 Ltr cap.
Bio metal for double door refrigerator 295/300/310 Ltr cap.
Fan motor for double door refrigerator 295/300/310 Ltr cap.
Cabinet bulb (E-14) 15 watt medium thread type Make- OSRAM/OMEX
Cabinet bulb (E-27) 15 watt thread type Make- OSRAM/OMEX
Cabinet bulb (E-14) 15 Watt BC pin type Make- OSRAM/OMEX
Thermostat switch automatic defrost type with knob, Make-Indofoss
PCB for refrigerator double door frost free 295/300/310/320 Ltr cap.
Over load protector suitable for 286/300/310 ltr cap
Door switches for refrigrator suitable for 165/286/300/310 ltr cap
S&F in repairs following spares for water coolers of different make capacity 40 ltr / 150 ltr :-
Starting relay 1/3 HP Kriloskar compressor
Over load protector 1/3 HP
Thermostat switch Make - Indofoss
Condenser fan blade set HDPVC for water cooler 40 ltr cap of clockwise direction
Condenser fan blade set HDPVC for water cooler 40 ltr cap of anti clock wise direction
Running capacitor 36 mfd, Make : Kail / Crompton / Tibcon / Epcos
PVC push cock 15mm bore. Make : Prayag or as approved by GE.
Self closing chromium plated water tap 15mm bore as per sample kept in GE’s Office complete all as per specified.
Starting capacitor 40-60 mfd, Make : Kail/Crompton
Float valve PVC 15mm bore with PVC ball and rod suitable for water cooler. Make :-Prayag / Ploytuf / Jindal
Starting capacitor 2.5 mfd, 80-100. Make : Kail/Crompton
Starting capacitor 10 mfd. Make : Kail/Crompton
Running capacitor 6 mfd. Make : Kail / Crompton / Tibcon / Epcos
Running capacitor 10 mfd, Make : Kail / Crompton / Tibcon / Epcos
Supply & fixing in repairs following spares for window type air conditioner/split type air conditioner capacity 1.5 TR / 2 TR of different make :-
Running capacitor 45(4+2) point mfd Make- Kail / Crompton / Tibcon / Epcos
Running capacitor 56(4+2) point mfd Make- Kail / Crompton / Tibcon / Epcos
Running capacitor 60(4+2) point mfd Make- Kail / Crompton / Tibcon / Epcos
Starting capacitor 100-120 Mfd. Make- Kail / Crompton / Tibcon / Epcos
Contactor for split type AC Make - Annpurna / Totalline
Thermostat switch for AC 1.5 TR. Make – Indofoss
Starting relay suitable for 1.5 TR AC. Make - TECHNO
Starting relay suitable for 2.0 TR AC. Make - TECHNO
Over load protector suitable for 1.50 TR cap AC
Over load protector suitable for 2.00 TR cap AC
Front grill for AC 1.5 / 2.00 TR cap
Air filter nylon for AC 1.5 / 2.0 TR cap
PCB for air conditioner window type 1.5 TR capacity
PCB for air conditioner window type 2.0 TR capacity
PCB for air conditioner split type 1.5 / 2.0 TR capacity
S&F in repairs the following accessories/spares for desert cooler of different capacity :-
Wood wool pad size 30" x 31"
Wood wool pad size 24" x 28"
Wood wool pad supporter of overall size 29"x30" made of GI Strip
Wood wool pad supporter of overall size 23"x27" made of GI Strip
PVC hose pipe 25mm bore high density
PVC hose pipe 32mm bore high density
Water lifting pump submersible type complete of Make - Khaitan / Polar
PT switch 5/6 Amp, 230 Volts, ISI marked.
Sealing compound in 75 gm packet , Make - M-Seal.
Air grill made of GI sheet 18 SWG suitable for 20" sweep cooler fan
Service lead (3 meter long) PVC insulated copper conductor 3 core size 23/0.0076 with & including 6 Amp Plug top.
PVC pipe 15mm bore heavy duty high density.
Iron leg (Set of 4)
Iron ring suitable for fan motor
Nut & bolt of any size
Capacitor 4 mfd suitable for desert cooler
PVC, 3 way distributors with supporting Elbow for 15 mm pipe.
Aluminium Fan Blade with bush powder coated for fan motor of desert cooler 20 inch sweep. Make - Symphony / Kaitan / CG
Insulation adhessive tape roll 25 mtr long in length. Make : Kinjol.
Shifting of Split type AC from one site to another by completely removing it from the existing place without any damage, and shifting it to new site including gas charging to req level commissioning and testing it to complete satisfaction of Engineer-in-Charge.
Shifting of Window type AC from one site to another by completely removing it from the existing place without any damage, and shifting it to new site, making necessary cutting in the wall, making it good including gas charging to req level commissioning and testing it to complete satisfaction of Engineer-in-Charge.
M&L for repair & rewinding of condenser fan motor of 1.5 TR window type air conditioner, 1/5 HP, 230 volt, 50 C/S with super enameled copper wire of same gauge and weight with & including replacement of rotor shaft, GM bush, Namda etc all as directed by Engineer-in-charge.
All as per serial item No. 52.00 here-in-before but 2.0 TR capacity.
All as per serial item No. 52.00 here-in-before but split AC, 1.5 TR capacity.
All as per serial item No. 52.00 here-in-before but split AC, 2.0 TR capacity.
All as per serial item No. 52.00 here-in-before but Water cooler 40/80 ltr Capacity.
All as per serial item No. 52.00 here-in-before but Water cooler 150 ltr Capacity.
All as per serial item No. 52.00 here-in-before but Deep freezer 200/320 ltr Capacity.
All as per serial item No. 52.00 here-in-before but Desert Cooler.
S&F rolled mild steel framed work as in steel framing for Desert Cooler and similar works, angle, tee & others sections, conforming to Grade E-165 (Fe 290) including necessary cutting, welding etc and fixing in position including grouting in wall, embedded in PCC (1:2:4) type B1 using 20 mm graded stone aggregate complete all as specified & directed. Note : Two coats of synthetic enamel paint over a coat of red oxide primer shall also be provided to new steel surfaces.
Taking down carefully, copper / aluminium unserviceable /perished point wiring any type for light/ fan/ socket or power complete including fittings such as switches, ceiling roses, pendant holders, lamp holders, bracket holders, regulators sockets, light fittings etc, and making good to disturbed surfaces of wall/floor/ceiling etc, complete, all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No. 62.00 here-in-before but for one ceiling fan/exhaust fan point controlled by one switch and regulator.
All as per serial item No. 62.00 here-in-before but for one bell/buzzer point controlled by one bell push.
All as per serial item No. 62.00 here-in-before but for one light point controlled by two, two way switch.
All as per serial item No. 62.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No. 62.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No. 62.00 here-in-before but for one 3 pin socket outlet 15/16 Amps controlledby one 15/16 Amps switch on independent board with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 250 Volts module type complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts module type complete all as specified and directed.
S&F socket outlet for 3 pin (with 2pin outlet also), 5/6 Amp, flush type 240 Volt Module type complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5/6 & 15/16 Amp, flush type 240 Volt module type complete all as specified and directed.
S&F PVC white cover plate with frame, 2 module.
S&F PVC white cover plate with frame, 3 module.
S&F PVC white cover plate with frame, 4 module.
S&F PVC white cover plate with frame, 6 module.
S&F PVC white cover plate with frame, 8 module.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, two way, 5 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts complete all as specified and directed.
S&F socket outlet 3 pin 5/6 (with 2 pin outlet) 5/6 Amp, flush type 240 Volt complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5/6 & 15/16 Amp, flush type 240 Volt complete all as specified and directed.
S&F bell push flush type 5 Amps 240 Volts complete all as specified and directed.
S&F electric bell multi music type AC 230 volts single pole complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
S&F decorative ultra slim liner LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube 6000K of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed. Make :- Havells Cat Part No LHEXBHP71NW018 or equivalent of Philips/ Crompton Greaves/Bajaj/Wipro as approved by GE
Removing and refixing decorative ultra slim liner LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt LED tube of model E-LITE LED Pride Plus and connecting up complete all as specified & directed.
S&F LED 16 watt ultra slim edge 2x2x feet lit panel in aluminium casing recess mounted square fixtures in white finish suitable for low ceiling height, 3 in 1, 3K, 4K, 6K with & including LED prewired and connecting up dismantling of old unsv recessed mounted light. Make :- Havells Cat Part No LHEBMDP7UZ1W018 or equivalent of Philips / Crompton Greaves/Wipro/Bajaj as approved by GE
S&F LED luminaries 1 x 20 watt 230 V 50 Hz and new E-LITE TRIYCA batten a color changing LED batten with options of 3000K, 4000K & 6500K all in one fixtures all as specified & directed. Make :- C&S Cat Part No LHEXBYPNIN1W020 or equivalent of Crompton Greaves / Wipro as approved by GE
S&F LED type street DRACO Series light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete, all as specified & directed. Make :- C&S Cat Part No LTESS20WLED or equivalent of Crompton Greaves / Wipro as approved by GE
S&F lamp holder PVC/Polycarbonatetype with back plate suitable forbatten fittings complete all as specified.
S&F stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts.
S&F sheet metal enclosures, double door type, suitable for fixing MCBs, TPN with 200 Amps rated bus bar, 4 way, 415 volts complete all as specified and directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCB,s, SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified and directed.
S&F MCB 35 to 63 Amps, single pole & neutral, 240 Volts complete all as specified and directed.
S&F MCB 5 to 32 Amps, single pole & neutral, 240 Volts complete all as specified and directed.
S&F MCB 6 to 30 Amps, single pole 240 Volts complete all as specified and directed.
S&F MCB 35 to 63 Amps, Triple pole & neutral, 240 Volts complete all as specified and directed.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 32mm dia (external) with wall thickness not less than 1.8mm & conduit fittings/accessories, fixed on surfaces of wall/ceiling complete all as specified and directed. Note:- 02 runs of 6 sqmm size, 01 run of 6 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
S&F 2nd class hard wood rectangular block open recessed of size 45x30x5 cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawlplug(4 Nos), complete all as specified and directed.
S&F 2nd class hard wood rectangular block open recessed of size 30x25x5 cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawlplug(4 Nos), complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with intter sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of aluminium stranded conductors of size 10 Sqmm all as specified and direceted including dismantling & taking down old unserviceable service cable with suspension wires & hangers..
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed.
S&F in repair switch piano flush type, single pole, one way, 5 Amp, 230 Volts complete all as specified and directed.
S&F in repair switch piano flush type, single pole, one way, 15 Amp, 230 Volts complete all as specified and directed.
S&F in repair bell push type 5 Amps 240 Volts complete all as specified and directed.
S&F as in repair socket outlet for 2/3 pin, 6 Amp, flush type 240 Volt complete all as specified and directed.
S&F as in repair socket outlet for 2 in 1, 3 pin, 15 Amp, flush type 240 Volt complete all as specified and directed.
S&F as in repair electric bell ding done type AC 230 volts single pole complete all as specified and directed.
S&F as in repair angular batten lamp holder poly carbonated body with back plate suitable for batten fitting complete all as specified and directed.
S&F as in repair stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts complete all as specified and directed.
S&F as in repair ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
S&F as in repair MCB 35 to 60 Amps, single pole & neutral, 240 Volts complete all as specified and directed.
S&F as in repair MCB 5 to 32 Amps, single pole & neutral, 240 Volts complete all as specified and directed.
S&F as in repair MCB 6 to 30 Amps, single pole 240 Volts complete all as specified and directed.
S&F as in repair MCB 35 to 63 Amps, Triple pole & neutral, 240 Volts complete all as specified and directed.
S&F sub main wiring on and including passing through in existing conduit pipe 1100 volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing unserviceable sub main wiring. (Note : Two runs of cable with one run of earth wire should measured as one length)
ALAKNANDA ENTERPRISES
Shiv Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .