Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹9.1 L+₹4,043 (0.45%)Rejected-Finance | L2 | Rejected-Finance bidder is not L1 | |
| 3 | L3₹10.8 L+₹1.8 L (19.9%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance bidder is not L1 | |
| 4 | L4₹11.9 L+₹2.9 L (31.8%)Rejected-Finance | L4 | Rejected-Finance bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹20,829
Closing Date
16 Jun 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer CKHED PWD
Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) KOLKATA
Replacement of very old AC Machines and allied EI work at Cath Lab OT of Chest Building of Calcutta National Medical College , Kolkata
2025_WBPWD_853368_1
WBPWD/EE-I/CKHED/eNIT10/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
40 days
NMCH
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,829
central kolkata health electrical division
1 Jul 2025
27 May 2025
18 Jun 2025
27 May 2025
16 Jun 2025
2 Jun 2025
2 Jun 2025
Amount
dismentling the old existing window/split AC machine (both indoor and outdoor unit) and shifted to the store as per instruction of EIC.
Supply & Delivery of 230V,1-Ph, 50Hz, 3Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 36000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 1200CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Supply & Delivery of 230V,1-Ph, 50Hz, 2.5Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 30000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 1000CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Supply & Delivery of 230V,1-Ph, 50Hz, 2Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 24000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 800CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Supply & Delivery of 230V,1-Ph, 50Hz, 1.5Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 18000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 600CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
Supplying fabrication & fixing of 2nos U-Channel (TATA Make) of size (50 mm x 50mm x 6mm thick) for making platform for instalation of outdoor unit incl. drilling 2nos holes in each channel as per site condition & as per direction of EIC. incl. cutting holes into the wall & grouting the same with cement concrete (1:1 %1/2: 3) etc incl. mending as orginal and fabricated with horizontal angle of 25 mm x 25 mm x 6mm including supporting angle 50 mm x50mm x 6mm in each platform in outer edge for transmitting the load centrally through 2Nos (50 mm x50 mm x 6 mm) Angle inserted to the exiting wall The entire structure should be baricated & safe for ODU maintenance Area of the platform is 2Mx1.2M or as per Machine configuration & load with adequate service access as per direction of EIC. (Structural design should be approved by E.I.C.)
Supply and fixing of AI powder coated continuous Grill (Make- Premier, Dynacraft/ EIC approved.)
Copper Refrigeration pipe line with 0.6 mm(min) & 0.7 mm (min) thick for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku/Totaline/Jobu/Nippon)
Liquid Line (1/4" OD or as per manufacturer specification)
Suction Line (5/8" OD withor as per manufacturer specification)
Supply & Fixing Pipe Insulation in liquid & suction line with 9 mm nitrile rubber tube (Accoflex/Armacell/Supreme)
Liquid Line (1/4" OD with 0.6 mm thick)
Suction Line (5/8" OD with 0.7mm thick)
Supply and laying 4 core 2.5 sq mm control copper cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel (Make: Gloster/Havells/RR Kable /Finolex/ Polycab)
Supply and laying of Drain Water piping work out of UPVC hard pipes of following sizes incl. nitrile insulation with fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required.(Make : Supreme / Astral/ EIC approved). 25 mm dia.
Supply & Fixing Pipe Insulation for 25 MM dia drain pipe with 9mm thick nitrile rubber tube (Supreme/Accoflex/Armacell/EIC Approved)
Hiring Charge of Scafolding Arrangements for installation of all the Indoor & Outdoor Units.
Supply and fixing of 1 phase timer control box for controlling AC machines made following accessories with IP - 42/43 protection with front door locking arrangement with all connection on angel iron frame on wall as per instruction of EIC.
a) 2+10 way size double door SPN MCBDB--1 No. (LK)
b) 240/415V, AC 32A, 2P Power contactor type MNX22-2P (Make-LK) - 1 No.
c) Daily & weekly programmable basis Digital Timer Switch, min switching time 1 min, 25 ON/OFF programs- 1 no.(LK) Cat no. - 67DDT0)
d) 240/415V, 40A, DP MCB Isolator (Make:Legrand) 1 no
e) 3 way Auto manual toggle switch--1 no.
f) AC ON/OFF indicator - 1 set
g) ON/OFF push button - 1 set.
h) Interconnection by 2.5 sqmm Cu wire--3 mtr.
S&F of 240V, 6-32A DPMCB of Breaking capacity 10kA & C characteristics on MCB SS enclosure making necessary connection, incl. S&F of 2 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (Make:- L&T/Legrand/ABB) [Ref.- D-6/7+D-9/11]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:- RR/Havells/Finolex/ Polycab/Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. [Ref.- E-14/1(a)]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [Ref.- F-5/9]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:- Legrand/Anchor/ Havells/ABB), Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:- Legrand/Anchor/ Havells/ABB), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.. [Ref : E-17/5(a)]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make:- Legrand/Anchor/ Havells/ North West) & necy. Connections. [Ref : E-17/5(b)]
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
MODERN TECHNO CORPORATION (BID ID -6583594)
S.R. REFRIGERATION AND APPLIANCES (BID ID -6578361)
UNIVERSAL SALES (BID ID -6578381)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .