| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-Finance NO 3 KEMPANNA ROAD MARUTHI SEVA NAGAR POST BANGALORE 560 033 BANGALORE KARNATAKA | BENGALURU URBAN | KARNATAKA | 560033 | ₹33.6 L | L1 | Accepted-Finance Being Lowest Bidder (L1) |
| 2 | L2₹35.3 LRejected-Finance 4 94D RAJA COTTAGE 1ST FLOOR KANYAKULAM PARVATHIPURAM NAGERCOIL KANNIYAKUMARI TAMILNADU 629 003 | KANNIYAKUMARI | TAMIL NADU | 629003 | ₹35.3 L | L2 | Rejected-Finance Not Being Lowest Bidder (L1) |
| 3 | L3₹36.1 LRejected-Finance | ₹36.1 L | L3 | Rejected-Finance Not Being Lowest Bidder (L1) |
| 4 | L4₹37.1 LRejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | ₹37.1 L | L4 | Rejected-Finance Not Being Lowest Bidder (L1) |
| 5 | L5₹41.5 LRejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | ₹41.5 L | L5 | Rejected-Finance Not Being Lowest Bidder (L1) |
| Sl No | Description | Qty | Unit | GS TRADERS L4 | RAMSON TRADERS L3 | M/S - KRUPA ELECTRICALS L5 | M AND V ENTERPRISES L1 | ADR ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil complete all as specified and directed. | 615.07 | Cum | 200 ₹1.2 L | 300 ₹1.8 L | 290 ₹1.8 L | 350.73 ₹2.2 L | 210 ₹1.3 L |
| 2.00 | Returning and filling in of excavated soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed. | 576.4 | Cum | 40 ₹23,056 | 50 ₹28,820 | 80 ₹46,112 | 140 ₹80,696 | 110 ₹63,404 |
| 3.00 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 167.17 | Cum | 60 ₹10,030.20 | 50 ₹8,358.50 | 100 ₹16,717 | 320 ₹53,494 | 120 ₹20,060.40 |
| 4.00 | M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and directed.
Note : Punned thickness only will be measured and paid. | 142.35 | Cum | 850 ₹1.2 L | 1,200 ₹1.7 L | 900 ₹1.3 L | 1,500 ₹2.1 L | 1,200 ₹1.7 L |
| 5.00 | Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge. | 10.54 | Per 1000 Nos | 9,000 ₹94,860 | 11,000 ₹1.2 L | 8,500 ₹89,590 | 10,000 ₹1.1 L | 7,000 ₹73,780 |
| 6.00 | S&F in replacement including testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 25 Sqmm 4 Core complete all as specified and directed. | 260 | RM | 225 ₹58,500 | 255 ₹66,300 | 300 ₹78,000 | 250 ₹65,000 | 230 ₹59,800 |
| 7.00 | S&F in replacement including testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 95 Sqmm 3.5 Core complete all as specified and directed. | 1,010 | RM | 750 ₹7.6 L | 650 ₹6.6 L | 675 ₹6.8 L | 520 ₹5.3 L | 600 ₹6.1 L |
| 8.00 | S&F in replacement including testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 10 Sqmm 4 Core complete all as specified and directed. | 210 | RM | 170 ₹35,700 | 170 ₹35,700 | 180 ₹37,800 | 170 ₹35,700 | 120 ₹25,200 |
| 9.00 | S&F in replacement including testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 16 Sqmm 4 Core complete all as specified and directed. | 514 | RM | 200 ₹1.0 L | 200 ₹1.0 L | 205 ₹1.1 L | 190 ₹97,660 | 145 ₹74,530 |
| 10.00 | S&F in repair GI tubing light grade 50 mm dia for protection of cable on pole, under road crossing or across drain, along electric pole or floor /wall along with suitable size of MS claps, nuts & bolts etc complete all as specified and directed. | 120 | RM | 400 ₹48,000 | 300 ₹36,000 | 300 ₹36,000 | 420 ₹50,400 | 400 ₹48,000 |
Updated dates
Tender Value
₹35.9 L
EMD Value
₹72,000
Closing Date
13 Apr 2026, 6:00 pmClosed
GE (Central) Bangalore
GE (CENTRAL) BANGALORE AGRAM POST BANGALORE KARNATAKA-560007
SPL REP TO EXTERNAL ELECTRIC WIRING AND PROVN OF GEYSER TO YOS BLOCK OF ASC CENTRE AND COLLEGE UNDER GE (CENTRAL) BANGALORE
2026_MES_756330_1
8597E
Open Tender
Electrical and Maintenance Works
180 days
ASC CENTRE AND COLLEGE BANGALORE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (CENTRAL) BANGALORE
₹72,000
Yes
2 Jun 2026
14 Mar 2026
16 Apr 2026
14 Mar 2026
13 Apr 2026
30 Mar 2026
16 Mar 2026 - 28 Mar 2026
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil complete all as specified and directed.
Returning and filling in of excavated soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and directed. Note : Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge.
S&F in replacement including testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 25 Sqmm 4 Core complete all as specified and directed.
S&F in replacement including testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 95 Sqmm 3.5 Core complete all as specified and directed.
S&F in replacement including testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 10 Sqmm 4 Core complete all as specified and directed.
S&F in replacement including testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100 Volt grade on walls with fixing acessories of 16 Sqmm 4 Core complete all as specified and directed.
S&F in repair GI tubing light grade 50 mm dia for protection of cable on pole, under road crossing or across drain, along electric pole or floor /wall along with suitable size of MS claps, nuts & bolts etc complete all as specified and directed.
S&F of MS steel angle iron work as in struts and posts in fencing including cutting tops to shape as directed, drilling holes notching for wire any flat iron fillets (for securing wire mesh and any wire type) including drilling, bolting or riverting, excn in post hole and embedding in angle irion and screwing etc similar work confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F of MS steel screw bolts(machine made) with hexgonal or square heads at ends and screwed end to be fitted with washers and one hexgonal or sqaure or square nuts not exc 30cm long and diameter of neck is 12mm complete all as specified as directed.
Supply only Chain link MS Galvanised fencing 50mm Mesh all as specified and directed. Note : Wt of fencing will be ascertain by Bd of Offrs.
Fixing only chainlink fencing including line wires any mesh,size and type straining bolts including provision of binding wire complete all as specified and directed. Note : supply of chain link fencing shall be measured and paid separately under ser No 13
Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door, cubical type panel board of over all min dimension 1.2 m (L) X 1.00m (H) X 0.50m (W) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs, powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Aluminium bus bar of 250 Amps Capacity (Main bus bar ) and 600 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work complete all as specified and as directed. (a) INCOMING : MCCB 4 pole 250Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No (b) OUTGOING : MCCB 4 pole 100Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -03 Nos (c) O/G MCB TPN 63Amp, 10KA,C curve - 03 Nos . (d) Indicating lamp LED type 240V 50 Hz AC -one set of 3
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for LT 20x15 cm size including dismantling of old one complete all as specified and directed
M&L for earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion complete all as specified and directed by Engr-in-Charge. Note :- Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc all as required for complete earthing.
Supply and installation of Three Phase Energy Meter Box made of weatherproof UV-resistant polycarbonate / powder-coated CRCA sheet, suitable for housing a single-phase energy meter. The box shall include necessary internal mounting plate, sealing provision, knockouts for cable entry/exit, lockable door, and comply with utility/authority specifications complete all as specified and directed. Note : Energy meter is not included in the item.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations of stays and poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 with 20 mm graded stone aggregate for coping above Ground level of steel pole including necessary form work complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation, mass concrete, pole base concrete 15cm Depth in bottom of Pit for bed concrete complete all as specified and directed
Dismatling of old u/s RCC pole any size, Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including necessary earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 mtr, PCC (1:4:8) type D-2 (using 40 mm graded sand stone aggregate) in the base Concrete 15cm Depth in bottom of Pit for bed concrete and foundation upto ground level and PCC (1:2:4) type B-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping above Ground level of steel pole, PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations of stays and poles including necessary form work including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2" height 06 Nos letters complete all the metallic surfaces all as specified and directed by Engineer-in-Charge. Note : PCC (1:4:8) type D-2 (using 40 mm graded sand stone aggregate) and PCC (1:2:4) type B-1 (using 20 mm graded black trap/granite/basalt stone aggregate), PCC 1:3:6 type C-2 using 40mm graded stone aggregate and Earth work Paid and Measured Separetely
S&F energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium iP65 flood light with high power leds as light source, suitable for highlighting architectural facade highmast and general purpose lighting of 120 watt lamp with all accessories for fixing on pole/wall and electrical connection.
S&F in repair GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, size of 25 mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc complete all as specified and directed.
S&F in repair GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, size of 50 mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc complete all as specified and directed.
S&F in repair Gun-metal gate valve with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778 : 1984, size of 25 mm complete all as specified and directed.
Supply and Install of 5 WHP Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well (Casing pipe size 200/250 mm) inclusive of 40 metre long submersible cable and starter complete all as specified and directed.
Cutting of existing GI/DI Pipe and connecting the pipe line with connected items all as specifoed and directed
M&L for Concealed Sub main wiring with 2 runs of 4.0 sqmm, single core, FRLS insulated & unsheathed cable conforming to IS-694, FRLS, 1100 volts with copper conductor multi stranded drawn in non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor FRLS Cable as continuos earth wire dolly and connecting to existing main switch board / distribution board of the building as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note : 02 run of 4.00 sqmm and 01 run of 4.00 sqmm as earth wire shall be measured as one RM.
S&F Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note : 02 run of 6.00 sqmm and 01 run of 6.00 sqmm as earth wire shall be measured as one RM.
S&F Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 6 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified and directed.
S&F Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type,double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified and directed.
S&F MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity complete all as specified and directed.
S&F MCB single pole & neutral 32 Amps 240 volts, C series,10 kA rupturing capacity complete all as specified and directed.
S&F MCB Tripple pole & neutral 40 to 100 Amps 415 volts, C series,10 kA rupturing capacity providing in DB complete all as specified and directed.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
M&L for wiring for circuit/submain wiring alongwith earth wire with the sizes 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface incl PVC casing caping complete all as specified as directed.
S&F of single pole MCB of capacity 20 Amp, C-curve 240V complete all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed of 15 mm bore complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 600mm for HOT and cold water accordingly complete all as specified and directed.
S&F GI Tubes 15mm bore, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors 'medium grade' complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 pin, 6 and 16 Amp flush type universal including gang box neon flash indicator with fittings complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_847193.xls
BOQ • 1.31 MB
TENDER8597.pdf
Tender Documents • 0.29 MB
Download all tender documents and submit your bid