Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 CrAccepted-AOC | ₹8.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹8.7 Cr+₹38.2 L (4.59%)Rejected-Finance NOT SPECIFIED | ₹8.7 Cr+₹38.2 L (4.59%) | L2 | Rejected-Finance Being Not Lowest |
| 3 | L3₹8.7 Cr+₹38.7 L (4.65%)Rejected-Finance | ₹8.7 Cr+₹38.7 L (4.65%) | L3 | Rejected-Finance Being Not Lowest |
| 4 | L4₹8.9 Cr+₹54.2 L (6.51%)Rejected-Finance | ₹8.9 Cr+₹54.2 L (6.51%) | L4 | Rejected-Finance Being Not Lowest |
| 5 | L5₹9.7 Cr+₹1.3 Cr (16.1%)Rejected-Finance | ₹9.7 Cr+₹1.3 Cr (16.1%) | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹9 Cr
EMD Value
₹7.8 L
Closing Date
23 Jul 2020, 6:00 pmClosed
CE (AF) Gandhinagar
Lekawada Patia, Chiloda, Gandhinagar 382042
PROVISION OF OTM ACCN AT AF STN PUNE
2020_MES_352373_1
83228
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) Lohegaon
As per NIT and Tender Document
9 documents required · 9 mandatory
₹3,000
GE (AF) Lohegaon
₹7.8 L
Yes
1 Oct 2020
12 Jun 2020
24 Jul 2020
12 Jun 2020
23 Jul 2020
6 Jul 2020
15 Jun 2020 - 20 Jun 2020
Amount
NOTE: Schedule ‘A’ Part I to XIV are under Ser No. 2.00 to 15.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part III
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV
Lump sum price worked out for Road/Path/Hard Standing as listed in Sch `A’ Part V
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VII
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part VIII
Lump sum price worked out for External Electric Supply as listed in Sch `A’ Part IX
Lump sum price worked out for Fire Alaram System as listed in Sch `A’ Part X
Lump sum price worked out for Fire Fighting System as listed in Sch `A’ Part XI
Lump sum price worked out for Refrigeration & Air Conditioning as listed in Sch `A’ Part XII
Lump sum price worked out for Fencing/Gate/Retaining/Wall as listed in Sch `A’ Part XIII
Lump sum price worked out for Lightining Protection as listed in Sch `A’ Part XIV
SCHEDULE 'A' PART - XV Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
INTERNAL ELECTRIFICATION
Supply and fixing ceiling fan 1400mm sweep complete with blade, canopy and down rod, energy efficient 5 star rated high speed with minimum 2 yrs warranty including copper winding and connecting up to and including provision of flexible three core copper conductor cable 23/0.0076 from ceiling rose to connector block etc complete all as specified and directed.
Supply and fixing wall mounted fan 400mm sweep complete with stand, clamp, copper winding with star rated and other fixtures and connecting up to and including provision of flexible three core copper conductor cable 23/0.0076 from ceiling rose to connector block etc complete all as specified and directed.
Supply and fixing metallic Exhaust fan 300mm sweep 240 V AC single phase complete with lovers and shutters of any sweep including provision of flexible three core copper conductor cable of 23/0.0076 upto ceiling rose and grouting 04 Nos full threaded bolts and nuts etc complete all as specified and directed.
Supply and fixing metallic Exhaust fan 450mm sweep 240 V AC single phase complete with lovers and shutters of any sweep including provision of flexible three core copper conductor cable of 23/0.0076 upto ceiling rose and grouting 04 Nos full threaded bolts and nuts etc complete all as specified and directed.
Supply and fixing LED batten single tube 1 x 20 W (4 feet long) 230V AC, IP20, 6000K, Rated CCTenergy efficient with automic ballast bipin holders starter blocks, diffusers etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing asthetically designed, slim type 2x2 LED flat recess/surface mounting fitting of 36 watt, 6000K, IP20, operating voltage range 100-277 volts, no harmful UV and IR radiation with average life of 50000 hrs complete suitable for working on 230 V single phase AC supply etc complete all as specified and directed. Make: Havells/Wipro/Philips/Syska
Supply and fixing LED batten single tube 1 x 10 W (2 feet long) 230V, AC, IP20, 6000K Rated CCTenergy efficient with automic ballast bipin holders starter blocks, diffusers etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing LED Building Security light luminaire LED 25 W, IP66, 5700K with aesthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connection including bracket made of 40 mm dia GI pipe light grade fixed with MS Clamp of suitable size grouted on wall with suitable nos of screws complete all as specified and directed.
Material & labour for RCCB having 30 Amps 2 module, 40 Amps capacity IP 20 complete all as specified and directed.
Material & labour for MCB single pole 5 to 30 Amp 240 volt C curve 10 KA, IP 20 complete all as specified and directed.
Supply and fixing Power unit for AC including MCB SP of 25 Amp and one START and one STOP push button complete all as specified and directed.
Material & labour for MCB TP 415 V, C curve, IP20, 10 KA, 63 Amps complete all as specified and directed.
Supply and fixing MCB DB SPN 2 WAY powder coated sheet steel enclosure with control of 16 Amps MCB SPN for 6 Nos of LED light 1x20 W fittings & testing complete all as specified and directed.
Supply and fixing MCB Distribution box 4 way, IP43, 230 Volts double door complete with following MCB SPN 40Amps,240V-1No MCB SP 6 to 32Amps,240V-2Nos
REFRIGERATION AND AIR CONDITIONING
Supply and install PVC body desert cooler electric driven (single phase) having nominal air flow capacity 5000 cum per Hr including complete all as specified and directed. Make : Symphony/Bajaj Model : DC 2016 Glacier.
(i) Supply, install testing commissioning of 5 Star rated inverter AC having 1.5 TR capacity, precision cooling technology, dual rotor inverter compressor, BLDC motor, filters, cold plasma technology, 100% copper coils of indoor, outdoor units including installation kit for indoor & outdoor unit, length, of refrigerant copper piping with insulation, coard cable, drain pipe, as required at site upto 7.50 RM. Refrigerant shall be echo friendly (R-410a, R-32) complete all as specified and directed. Make - Blue Star/Hitachi/Voltas Note : Drain water outlet pipe shall be provided inclined at 45 deg angle and concealed in wall or as per site requirement complete all as directed. (ii) Rate of copper pipe coard cable, drain pipe upto 7.50 RM deemed inclusive in quoted rate.
Supply, install testing commissioning of 5 Star rated inverter AC having 2.0 TR capacity, precision cooling technology, dual rotor inverter compressor, BLDC motor, filters, cold plasma technology, 100% copper coils of indoor, outdoor units including installation kit for indoor & outdoor unit, length of refrigerant copper piping with insulation, coard cable, drain pipe as required at site upto 7.50 RM. Refrigerant shall be echo friendly (R-410a, R-32) complete all as specified and directed. Make - Blue Star/Hitachi/Voltas. Note : Drain water outlet pipe shall be provided inclined at 45 deg angle and concealed in wall or as per site requirement complete all as directed. (ii) Rate of copper pipe coard cable, drain pipe upto 7.50 RM deemed inclusive in quoted rate.
INTERNAL WATER SUPPLY
Supply and fix angle cocks (ISI marked) cast copper alloy screwed down for iron pipe or for brass ferrule and fixed of size 15mm bore complete all as specifie and as directed.
FIRE ALARM SYSTEM
Supply and fixing of Intelligent addressable Four Loop fire alarm panel complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron
Supply and fixing of Intelligent addressable Two Loop fire alarm panel complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron.
Supply and fixing of Intelligent addressable 1 Loop fire alarm panel complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron.
Supply and fixing of Intelligent addressable Repeator panel complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron.
Supply, fix and testing of multi criteria detector with base complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron. (Below Ceiling)
Supply, fix and testing of multi criteria detector with base complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron. (Above Ceiling)
Supply, fix and testing of addressable Hooter cum strobe complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron.
Supply, fix and testing of manual call point complete all as specified and directed ,Make Notifire Make: Honeywell/Notifire/Context plus/Secutron.
Supply, fix and testing of Isolator module complete all as specified and directed Make: Honeywell/Notifire/Context plus/Secutron.
Response Indicator Make Agni complete all as specified and directed.
Supply, fix 1.5 Sqmm 2 core copper armoured cable flame retordant including saddles, screen etc on wall and testing complete all as specified and directed Make : Polycab, Indian Cab, Finolex, CCI.
Supply,Laying & fix 1.5 Sqmm 8 core copper armoured cable flame retardant including saddles, screen etc on wall and testing complete all as specified and directed Make : Polycab, Indian Cab, Finolex, CCI.
ROADS
Material & labour for 150mm compacted thickness GSB Gde-III in two layer (100mm Each) with prepartion of sub grade, homogenous & uniform mixing, spreaded, watered and rolled with vibratory roller of minimum 80 to 100 KN static weight with plain drum and consolidated to required gradient and camber etc, complete all as specified and directed in MORTH and directed.
Material & labour for 150mm compacted thickness WMM Gde-I in single layer with prepartion of of base, preparation mix, spread, rolled with vibratory roller of minimum 80 to 100 KN static weight with plain drum and consolidated to required gradient and camber etc, all as specified in MORTH and directed.
Material & labour for precast kerb stone as in road edging using M35 cement concrete including fixing complete all as specified and directed.
EXTERNAL WATER SUPPLY
Cutting/drilling and macking connetion of 40mm dia GI pipe with existing 150mm dia CI pipe line and including fixing/insertion of fitting as required at site complete all as specified and asm directed.
Supply & fix 15 mm bore angle cocks cast copper alloy screwed down for iron pipe or for brass ferrule and fixed complete all as specified and asm directed.
Supply & fix chromium plate health faucet having 15 mm bore thread connection with 1.2 m long flexible metal hose with holding bracket complete all as specified and asm directed.
Supply & fix toilet paper holder of brass chromium plated fixed to walls with chromium plated brass screws complete all as specified and asm directed.
Supply & fix 15 mm nominal size brass tee fittings complete all as specified and asm directed.
EXTERNAL ELECTRIFICATION
Supplying, installation, testing and commissioning with AMF panel diesel engine driven generating set of 100 KVA (80 KW) capacity of continous rating at N. T. P fully wired 415 V AC 3 phase, 4 wire 50 Hz, at a power factor of 0.8 lagging all as per IS-4722/2001 mounted on common base plate and directly coupled through flexible coupling closed couple to diesel engine with dunlop cushy foot mountings (anti vibration) pad in and including acoustic insulated enclosure/canpoy with noise level 70 db at one meter distance as per CPCB norms from gen set and PCC/RCC foundation as per manufactures recomendation and complete all as specified and directed at site etc & consisting of the following:-
(A) Diesel Engine:- the engine shall be vertical multicylinder four stroke of suitable BHP to devolope 100 KVA (80 KW) power at 1500 RPM water cooled complete with water pump assembly turbo charger, battery charging alternator of 12 V instrument panel, electronic in built, governor suitable battery of minimum 88 AH capacity, 12 volt confirming to ISO 3046/BS 5514 heavy duty with leads suitable size on exhaust pipe of suitable length inclusive of exhaust coupling inside acoustic enclosure and residential silenceer pipe above canopy all as specified & directed by OEM and all other standard fittings/fixtures and all as per OEM specification complete as per IS-1602 for the generator including the following:- (a) Engine protection devices including audio visual indicators & OFF system during low iube oil pressure high water temperature over speeding of engine (b) Radiator cooling system comprising of radiator fan blade water pump with belts thermostant guard (c) Hour meter.
(B) AC ALTERNATOR (Brush less):- The AC alternator (generator) shall be designed for an output of 100 KVA(80KW) at full load for continuos rating at 0.8 (lag) PF conforming to IS-4722 or BS-2613 RPM 1500 insulation class : "H" including self exciting and self regulating control panel with all accessories cable terminal box with suitable size of glands earth terminal etc complete all as per OEM specifications and connection for alternator output terminals to AMF panel shall be with copper conductor with suitable size & cost deemed to be inclusive of the unit rate coated for gen set (C) Built up fuel tank of capacity 350 Ltr.
(D) AMF panel:- The AMF panel outdoor type shall be fabricated & mounted on 100 mm MS channel frame shall be totally enclosed cubical type fabricated out of 2mm thick CRCA sheet duly powder coated with 7 tank chemical powder coated process locking arrangement provn of self ventillation with wire mesh etc panel shall be IP 56 CPRI Approved complete including with base etc 2 sets of 3 nos contactors 4 pole 415 V 50 Hz AC supply for DG auxlliary contactors relays for automatic operation of DG set incase of failure commercial supply & vice versa tinned Aluminium Busbar of 1.8 times of alternator rated capacity with heat shrinkable PVC sleeves cable termination box with suitable size of glands and comprising following accessories complete all as specified and directed.
(E) Acoustic insulated enclosure/canopy for gen set:- The gen to be provided with acoustic insulated enclosure/conopy fabriciated out of CRCA sheet 16 SWG & pre treated with 7 tank phosphating prior to polyester coating painting close fit type compact enclosure provided with adequate ventilation system to ensure perfect aspiration and cooling of the DG set to bel housed inside and avoide over heating /power deration. Acoustic insulation sound proofing should be made with a high quality insulation conforms to UL94-HF1 class for flammability and suitable including the folliwing:- (a) Control pannel should have blanking windows made out of toughened glass provided with rubber beading (b) Emergency stop button should be easily accessable.
(c) Provn of T/L fitting of branded make including wiring inside canopy (d) All door, windows pannels should be lockable with single key (e) Single/multi point lifting ficility should be available on the base frame (f) Adequate ventilation has to be provided to meet the air requirement of engine and alterator Note:- (i) Tempareture risein the compartment/canopy should be less than 5 degree centigrate.
(ii) It should adhere tomandatory noise regulation norms (iii) It should be duly approved and guaranteed by the engine manufacture (iv) The acoustic insulated enclosure/canopy must be designed as per relevant IS and control the noise level all as specified in govt of india notification GSR 7 dated 22 Dec 98 and GSR No 37(E) F No 8-15022/2/2001. (v) LT cable from DG set to AMF panel shall be measured & paid for separated (vi) The FOL & artificial resistive load etc required for commissioning and testing of DG set shall be supplied by the contractor.This shall be deemed to be including in the quoted rate of Gen Set.
(vii) Servicing of DG set up to defect liability period shall be carried out as per OEM maintenance schedule program (viii) All spare parts required for servicing shall be provided by the contractor. The rates shall be deemed to be included in the quoted rates. (ix) Maintenance schedule shall be provided to department after successfully installation of DG set.
Supply & fix Servo controlled oil cooled Voltage Stabilizer for automatic operation, three phase naturally cooled outdoor type & designed for input variation between 300V to 480 V with output voltage stabilized at 415 with accuracy +-2.5% and speed of correction 8 volts per second and capacity 125 KVA complete all as specified and directed.
UG cable route indicator made out of 100 mm dia MS plate with 20mm dia 50cm long MS bar as legs for writing HT/LT cable fixing with and including necessary PCC 1:2:4 in grouting route complete all as specified and directed.
Supply, Install, Test and Commissioning of LT panel Board outdoor type fabricated out of 3.15 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame, duly grouted with PCC reqd. with the following (Panel No-01)
Supply, Install, Test and Commissioning of LT panel Board outdoor type fabricated out of 3.15 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame, duly grouted with PCC reqd. with the following (Panel No 2 & 3)
Supply, Install, Test and Commissioning of LT panel Board outdoor type fabricated out of 3.15 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame, duly grouted with PCC reqd. with the following (Panel No-04)
M&L for supply, installation, testing and commissioning of copper pipe electrode maintenance free earthing based on 3 Mtr long copper pipe 50mm dia (ID) with wall thickness of 2mm, copper strip 32x6mm, 3.08 mtr in length (3 mtr inside the copper pipe electrode and 8 cm at the top of the pipe with 2 Nos 12 mm holes for earth strip connection) and copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, min 60 Kg BFC shall be filled around copper pipe electrode, including providing FRP pit cover of size 250x250x250mm complete as per manufacture specification and complete all as specified and directed Note: (i) Rate included for boarding by drilling machine of min 150mm dia upto 3.6 to 4 mtr as recommended by OEM for earthing in any type of strata and testing, commissioning, checking earth continuity with calibrated tester (ii) Vendors are bound to get earthing result below 2 OHM with single earthing and below 1 Ohm with grid of two earthing for this any additional work, material or additional earthing in grid required at site to achieve the required result is included in the quoted rate nothing extra will be paid (iii) Earth strip shall be measured and paid separately.
Supply & fix heavy duty PVC conduit of 25 mm dia concealed in wall, floor, roof etc with all accessories complete all as specified and directed at site for BMS/AFNET cable.
Supply, install, commissioning and testing of Air shower for two persons with internal size of 1100mm x 1100mm x 2100mm made out of CRCA Sheet duly powder coated having face velocity 6000 ft/min, plus minus 20 ft. Operation time (adjustable) 0-9.990 seconds. Pre filter-washable pre filter unit (non-woven synthetic polyester), HEPA filters-glass pleated non-wooven fabric filter having 99.995 efficiency down to size 0.3 microns particles, air flow control solid state control unit, blower assembly, centrifugal lubricated bearing type, ISI marked assembly, illumination using fluorescent light illumination greater than 800 lux, noise level less than 60 db, add on sequential feature operation by dorr mate magnetic switch suitable for operation at 220 to 240 volts, 50 Hz, single phase. Cleanness class 100, elect motor 02 Nos of 1 HP, having 3000 rpm, 16 Nos Nozzles, Air celocity 25-30 m/s complete all as specified and directed. Make : Purafil/Macro flow/Photon.
FENCING
Material & labour for steel gate of 5.50 m wide and 2.4m ht inclusive excavation in hard/dense soil, RFR and removal of soil exc 250m but n exc 500m, PCC 1:4:8, foundation and RCC column (Design Mix M-25), steel gate of MS angle iron inclusive 10mm thick plaster in CM 1:4, cement painting in two coat of pillar and two coats of synthetic enamel paint over a coat of red oxide primer to steel work completed all specified and shown on TD Drg No CEAA/TD/70 dt 01 Dec 1993
FIRE FIGHTING SYSTEM
Cutting/drilling and making connetion of 150mm dia GI pipe with existing 150mm dia CI pipe line and including fixing/insertion of fitting as required at site complete all as specified and as directed.
Supply, installation testing and commissioning of LT panel board indoor type, cubicle & compartmentalized, front access type, medium voltage elect panel of dust & vermin proof construction, front open able doors and shutters with locking arrangement, made out of 2mm thick CRCA sheet factory fabricated, powder coated, suitable for operation oon 440 Volts, 3 Phase 4 wire, 50 Hz, AC supply complete with interconnection with suitable size copper cables and consisting of accessories like copper bus bars 200A, LED indicating lamps, Push buttons, CT’s, Digital Amp meters, digital volt meter, frequency meter, Danger plate, lifting hooks, feeder Name plates, suitable for the following feeders (Note :- The panel shall be of suitable size to accommodate all the accessories mention below, installed on pedestal made out of angle iron frame of size 50x50x6mm & earth work, PCC foundation, suitable cable glands for cable entry etc)
a) MCCB 4 Pole 100 A 25kA, (IC) (b) MCCB 4 Pole 100A 25kA (for Elect drive, fire Pump) (c) MCCB 4 Pole 32A 16kA (for jockey Pump (d) Automatic star delta starter (capacity as per design of pump) with overload protection, SPP, start stop buttons & On/off indication LED lamps (for elect driven fire pump set) (e) Automatic star delta starter (capacity as per design of pump) with overload protection, SPP, start stop buttons & On/off indication LED lamps (for elect jock pump) (f) Control system for automatic operation of Electric driven fire pump set, Jockey Pump & Diesel engine driven pump set. (g) Spare feeder with all accessories for (elect driven pump set & 1 for Jockey pump set).
United Sales Corporation
shah construction
ganesh electricals and airconditioners
V M MATERE INFRASTRUCTURES INDIA PVT LTD
N. H. Saluji & Associates
Saiprabha Construction
K R TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .