Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC LAL SAHAB KA BAGICHA MALL ROAD MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹27.4 L+₹1.0 L (3.88%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹28.1 L+₹1.7 L (6.48%)Rejected-AOC 23 A MORAR ENCLAVE GOLA KA MANDIR MORAR GWALIOR MP 474005 | GWALIOR | GWALIOR | MP | 474005 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹28.5 L+₹2.1 L (8.04%)Rejected-AOC ANAND BHAVAN GHASMANDI MORAR GWALIOR MP 474006 | GWALIOR | GWALIOR | MP | 474006 | L4 | Rejected-AOC Rejected |
Tender Value
₹36.3 L
EMD Value
₹72,600
Closing Date
10 Oct 2020, 6:00 pmClosed
CWE JHANSI
HQ CWE JHANSI
SPECIAL REPAIR TO BLOCK NO P-296 AND P-299 OR OTM ACCN AT 4TH INF LINE OF 25 GRENADIERS AT MORAR CANTT GWALIOR UNDER GE GWLAIOR
2020_MES_376933_1
CWE/JHA/GWL/63 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE GWALIOR
₹72,600
Yes
9 Nov 2020
12 Sept 2020
15 Oct 2020
12 Sept 2020
10 Oct 2020
28 Sept 2020
Amount
Demolition of reinforced cement concrete Roofs, floors , beams , column staircases, landing, chajjas ect and similar suspended work complete all as specified and directed.
Use & weste for formwork to chullah hoods, chajjas, troughs ect and similar items including edgesto beam, column, chajjas ect including edges for flat and rough finished surfaces of concrete complete all as specified and directed
M&L for reinforced cement concrete (1:2:4) type B-1 ( using 20 mm graded stone aggregate ) as in beams, Column, cantilevers bressummers , lintel over 1.5 m span etc. complete all as specified and directed.
M&L for mild steel TMT bars ,10mm dia and over, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M&L for mild steel TMT bars 5 mm and over upto and including 10 mm dia , as in stirrups , spacers , and binders , cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Taking down cement or cement lime plaster incl wall tiles, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L, 15mm thick rendering on brick or stone/concrete any surfaces in cement mortar 1: 4 on mixed with WPC @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid seperately complete all as specified and directed.
Supply only water proofing compound (ISI Mark) complete all as specified and directed.
M&L for Preparing of new or previous decorated surface of walls of plastered or unplastered surfaces by brooming down or steel wire brushing, scarping down smoke soot, moulds, moss and efflorescent salts treating oil and greasy spots and applying two coat of cement base paint complete all as specified and directed.
M&L for Preparing of old decorated surface of wall and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down , smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and M&L applying two coat of white wash , complete all as specified and directed.
M&L for preparing of old decorated surface of walls of plastered or unplastered surfaces by brooming down or steel wire brushing, scarping down smoke soot, moulds, moss and efflorescent salts treating oil and greasy spots and applying two coat of cement base paint complete all as specified and as directed
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces in cement mortar (1:6) and surface finished even and smooth, complete all as specified and directed
M&L applying 3mm thick wall care putty on walls to achive even and fair surfaces complete all as specified and directed.
M&L for preparing of new decorated plastered or unplastered surfaces of wall including washing , rubbing down and stopping of distempered surface M&L for applying two coat of distemper oil emulsion paint white or tinted complete all as specified and directed.
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel wire brushing or any other means, includind removing vegetable/ plants root from walls/chajja's and applying two coats of distemper, oil emulsion white or tinted over and including a layer of Birla or JK wall putty @ 1.20 Kg / Sqm complete all as specified and directed.
M&L, 10mm thick rendering on fair faces of brick work or concrete surfaces in ceiling, chajja ect in CM 1:3 surface finished even & rough complete all as specified and directed.
M&L for preparing of new decorated surface of ceiling and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down , smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and applying two coat of white wash complete all as specified and directed.
M&L for preparing of old decorated surface of ceiling and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down , smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and applying two coat of white wash complete all as specified and directed..
M & L for preparing surfaces of old decorated wood or wood based materials and applying one coat of synthetic enamel paint on surfaces not otherwise described over 10 cm width or girth complete all as specified and directed
M&L for applying one coat of synthetic enamel paint on old steel & iron surfaces (previously decorated) for grills, guard bars of any description not otherwise escribed over 10 cm in width or girth including preparation of old surfaces complete all as specified and directed.
M & L for applying two coat of synthetic enamel paint as subsequent coat on new wooden surfaces over 10 cm in width or girth including and over one coat of pink primer complete all as specified and directed.
M & L for applying two coat of synthetic enamel paint subsequent coat on new steel surfaces (previously decorated) for grills, guard bars, shutter etc including preparation of surfaces and including and over one coat of red oxide complete all as specified and directed.
M&L for Prepartion of old or new plastered surfaces of wall, chajjas ect and applying one coats of weather proof water based emulsion paint (Acrylic paint exterior grade) complete all as specified and directed .
Taking down Chowkats or frames not exceeding 1.5 Sq.m each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sq.m but not exceeding 4 Sq. m each (Without taking off shutters from the frame) complete all as specified and directed.
Taking down Shutter of any type not exc 1.0 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1 sq. m and n exc 2 sqm each complete all as specified and directed.
Refixing in same opening of shutters of any description n exc 1 Sqm each complete all as specified and directed.
" -ditto- but exc 1 sqm but nexc 2 sqm each complete all as specified and as directed.
S&F second class hard wood plain solid straight chowkhats and frames wrought frammed ribated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed
S&F solid PVC doors frames of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, in opening as per specification and drawing as specified in clause 8B-1 to 8-B-10 on page 133 to 138 and page 146 to 153 of SSR -2004 part-II complete all as specified and directed
S&F factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC`C` channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles ad plain colour PVC sheet for top rail, lock rail & bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame complete all as specified and directed.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed all as specified and directed
M & L for factory made 30 mm 2nd class hard wood, plain framed panelled shutters with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board medium density, wood particle board with commercial veneering on both face IS 1003 (Part-I) kiln seasoned and chemically pressured treated complete all as specified and directed.
S&F 2nd class hard wood, 30mm thick glazed and skelton shutters open ribeted and prepared to receive glass guage etc (without sash bars) edges of framing plain chamfered or rounded , fitted with cut and mitered beads for securing glass etc size of members of shutters as specified in SSR part I section 8 cloum 8.20 (a) of SSR Pt-I complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed.
S&F Aluminium handle cast type anodised of 100mm size complete all as specified and directed.
S&F in repairs extruded aluminum alloy handles 100 mm size fabricated type anodized all as specified complete all as specified and directed.
S&F in repairs mild steel pressed handles,ovel type ,stove enamelled black 150 mm size all as specified complete all as specified and as directed .
S&F Butt hinges, Medium Weight, cold rolled mild steel, and fixed 100 mm complete all as specified and directed.
S&F in repair butt hinges 100mm long medium weight, cold rolled mild steel complete all as specified and directed.
S&F butt hinges 75 mm long medium weight, cold rolled mild steel complete all as specified and as directed.
S&F 100 mm long aluminum anodized barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F in repairs 100 mm long mild steel barrel tower bolts, stove enamelled black ,with bright bolt and fixed complete all as specified and directed.
S & F in repairs 200 mm aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections or cast aluminium alloy complete all as specified and directed.
S & F 300 mm aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet , cast or extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in repair 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed
Dismantiling of stone slabs and tiles of any discription or any thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for 25mm thick cement concrete type B0, 1:2:4 (12.5 mm graded aggregate) as in leveling course complete all as specified and directed.
M&L screed bed or bedding layer of mortar 15 mm thick in cement mortar 1: 6 for laying floor finishes complete all as specified and directed.
M&L non skid ceramic tiles 6to8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L non skid ceramic Coloured tiles, 300mmx300mmx5mm to7mm thick, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tiles, over screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed.
M&L glazed ceramic coloured tiles 300mm x 200mm x 5 mm to 6 mm thick, in skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles complete all as specified and directed.
M & L for machine cut Kota stone slab 18 to 20 mm thick and min size of kota stone shall be 500x500 mm laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing ect over and including 20mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed.
M&L Kota stone slab 18 to 20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed withover and including 10mm thick rendering in cement plaster 1:4 on the other side of lathing and pointed with coloured cement complete all as specified and directed.
M&L for Granite (of any type) tiles 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone and fixed as required on site complete complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built incement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for brick work with sub class `B' bricks, straight or curved on plan exceeding 6m mean radius(except bricks), built in cement mortar 1:6 complete all as specified and directed. (Note :- old bricks may be obtained from above demolition of brick work item).
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed
M&L for 75 mm thick Cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregate) as in plinth protection ect incl finishing the surface even and smooth w/o using extra cement complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S&F 3mm thick Sheet Glass ordinary qulity and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F figured glass, pin head type 3.0 mm thick and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F in repair galvanized mild steel wire cloth with 0.46 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed.
S & F galvanized mild steel wire cloth with 0.46 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and as directed.
Removing existing water proofing treatment (Brick tile terracing)/ any type menbrane, roughning of concrete surfaces, cleaning of concrete surfaces with water and removing debries/rubbish off materials out side of Ministry of defence (MOD) land complete all as specified and directed.
M&L for providing two coats of tap creat (Make -M/S Cico /Pidicrete, M/S Pidicrete /Nitobond M/S Fos Roc) chemical mixed in proportional ratio 1:1 one part of chemical, one part of cement slurry, complete including curing surfaces complete all as specified and directed.
M&L 10mm thick rendring with CM (1:4) over roof surface surface even and smooth mixed with WPC complete all as specified and directed.
M & L Plain cement concrete (1:2:4) Type B0 using 12.5 mm graded stone agg as levelling course/mass concrete/edge of pathway etc complete all as specified and directed.
M&L, water proofing treatment to roof slab with APP modified membrane weight not less than 3.00 Kg/Sqm and thickness of membrane not less than 3 mm reinforcement with polyster non woven polyster mat (wt not less than 160 g/sqm) water absorption of not more than 1% on mass within 24 hrs and water tightness/impermeability at 2 Kg/sq cm on primed surface with torch application method as per manufacture instruction, complete all as specified and directed with following descriptions : - (a) Applying evenly a coat of bitumen primer confirming to IS 3384-1965 @ 0.30 kg/sqm. (b) Laying of APP modified membrane with 100 mm over lap in longitudinal direction and 100 mm in transverse direction. (c) Thermal insulation with mineral / gravel finish of upper side of membrane uniformly embedded during manufacturing process.
S & F PVC cabinet with shelve 450x600mm including mirror fixed to wall with brass cleat with shutter complete all as specified and directed.
Taking up or down steel tubing and connection incl cleaning for refixing or removal to store of 15 mm bore complete all as specified and directed.
All as per Item No 74 but 20 mm complete all as specified and directed.
M&L for water tubing medium grade 15 mm bore with all fitting and fixed complete to walls and ceiling or laid floorstubing and connection incl cleaning for refixing or removal to store of 15 mm bore complete all as specified and directed.
All as per Item No 76 but 20 mm complete all as specified and directed.
Refixing old steel tubing and connections in new or old positions (walls, ceiling, floor etc) of 15mm bore complete all as specified and directed.
Refixing old steel tubing and connections in new or old positions (walls, ceiling, floor etc) of 20 mm bore complete all as specified and directed.
Cutting chases , pinning in , making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings etc and cutting chases for concealed water tubing etc and making good , cutting n exc 10 cm girth complete all as specified and directed.
S&F 15mm chromium plated angle /Stop cock fancy type chromium plated,cast copper alloy, with capston heads,scewed down high pressure, with or without lettered 'hot' or Cold' with long srewed shanks and flynuts, srewed for iron pipe fixed in repair complete all as specified and directed.
S&F 15mm, chromium plated piller cock fancy type chromium plated,cast copper alloy, with capston heads,scewed down high pressure, with or without lettered 'hot' or Cold' with long srewed shanks and flynuts, srewed for iron pipe fixed in repair complete all as specified and directed.
S&F 15mm ,bib tap , fancy type chromium plated,cast copper alloy, with capston heads,scewed down high pressure, with or without lettered 'hot' or Cold' with long srewed shanks and flynuts, srewed for iron pipe fixed in repair complete all as specified and directed.
Dismantling of water tank exc 500 ltrs and n. exc 1000 ltrs capacity and removing from site complete all as specified and directed.
S&F,1000 ltr capacity rotational moulded polythene water storage tank two layers ISI Marked (cylindrical vertical with closed top ) hoisted and fixed in position complete all as specified and directed.
S& F ball brass valves high pressure with polythene float valve and fly nuts complete screwed for iron pipe or for brass ferulle of 20mm bore complete all as specified and as directed.
S & F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
Dismantling and breaking up PVC/AC rain water / vent / waste / drain pipes 32 mm dia to 110 mm dia including fittings complete all as specified and directed.
S&F, 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint laid in floor or fixed to wall etc. complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint laid in floor or fixed to wall etc. complete all specified and directed.
S&F, 75 mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F, 75 mm bore, PVC bends or elbows, square, obtuse complete all as specified and directed.
S&F, 110mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F, 110mm bore, mm bore, PVC bends or elbows, square, obtuse complete all as specified and directed complete all as specified and directed..
S&F, 110 mm bore PVC (SWR) vent cowl, complete all as specified and directed .
S&F PVC(SWR) floor trap plain with grating including jointing with solvent cement and fixed to 75mm dia outlet pipe complete all as specified and directed
S&F PVC(SWR) gully trap125/110mm, setting and jointing with solvent cement complete all as specified and directed
S&F in repair water closet including provision of cement concrete bedding viterous china squatting pan orrisa pattern of size 580x440 mm white with integral foot rest etc. excluding flushing cistern complete all as specified and directed.
S&F in repair pedestal pan and tap, including connection to drain and flusing pipe and seat cover closed pattern with flat bottam, including cover and mild steel cromium plated or hinging device etc complete all as specified and directed.
S&F in repair stainless steel healt faucet with stainless steel tube and holder ect complete all as speicified and directed.
S&F, in repair.15 mm bore stop valve cast copper alloy screwed down high pressure with CAPSTAN HEAD handle chromium plated concealed type screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
S&F as in repair brass chromium plated shower rose of 125mm size complete suitable for 15mm dia of pipe complete all as specified and directed.
S&F in repair Vitreous china wash basin, white, flat back, size 550x400mm excluding taps, waste pipes including CI bracket, PVC 32mm dia waste coupling waste pipe complete all as specified and directed.
S& F pillar taps 15mm dia cast copper alloy with capstan heads , chromium plated screwed down high pressure with or without lettered "Hot or Cold". With long screwed shanks and fly nuts , scrfewed for iron pipe and fixed complete all as specified and directed.
S&F Soap dish of PVC fixed with pvc rawal plugs and screw complete all as specified and directed.
S &F tublar towel rail 20mm dia D type 60 cm long between flange brass chromium plated complete all as specified and directed.
S & F MS peg set of six hooks fixed to wall with PVC plugs and screw complete all as specified and directed.
S & F in repairs mild steel Chromium plated grating 100 mm dia, fixed to traps complete all as specified and directed.
S&F PVC valveless syphonic action type flushing cistern low level white with inlet ball valve,float end handle handle including bracket complete of capacity 10 litres complete all as specified and directed.
S&F15mm stop valves/cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
S& F in repair pillar taps 15mm dia cast copper alloy with capstan heads , chromium plated screwed down high pressure with or without lettered "Hot or Cold". With long screwed shanks and fly nuts , scrfewed for iron pipe and fixed complete all as specified and directed.
S&F15mm, bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair complete all as specified and directed.
S&F 15mm dia PVC connection with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair urinal, bowl type or half stall pattern, basin only including connections to flushing pipe and outgoing pipes fixed in repairs complete all as specified and directed complete all as specified and directed.
S&F in repair cutain rod of Stainless steel 22-25mm dia pipe thickness not less than 0.8mm of pipe with fixing bracket, side nobes etc fixed on walls with screws with PVC rawl plugs etc complete all as specified and directed.
Dismantling boarding any description / partition ect fixed with nails in any position (including cup board shutter/shelve upto 25mm thick) complete all as specified and directed.
M & L for 18 to 19 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S & F in 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
Dismatling of timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
S&F 30mm dia, cupboard knobs fixed with nut, screw and washer of mld steel, bright finished brass polished complete all as specified and directed.
S&F Ball catches with 6mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
M&L for plain fillets square, rectangular in section, wrought of second class HW exc 6 & n.exc 13 sq cm in size secured with screws complete all as specified and directed .
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed.
S&F 75 mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F in repair Mortice lock, vertical type, size 100 mm with two levers complete all as speceifed and directed,
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and directed.
S&F mild steel framed work for such as grills, gratings, etc. with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specefied and directed.
M&L for cement concrete type D-2, 1:4:8, (40 mm graded aggregate),75 mm thick, as in sub base for floor etc complete all as specified and directed.
M&L for 60 mm thickness machine pressed precast concrete interlocking paver block M-35 any shape and size confirming to IS 15658-2006 in grey cement glossy finish rubber mould casted laid dry over sandd cushioning complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L for chequered cement concrete tiles 250mm x 250mmx 25mm thick, set jointed and pointed in cement slurry in floors with grey cement and pigments complete all as directed including 15mm thick screed bed in CM 1:6 complete all as specifed and directed
M & L for Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed
M & L for point wiring with 1.5 sqmm (Nominal Area)PVC insulated FRLS un sheathed multi stranded copper conductor drawn in and including non metalic rigid PVC concealed conduit of med grade of suitable size with all fitings and accessories including factory made MS/ pressed steel terminal box with zinc coated duly concealed in wall including modular metal flush boxes reqd as per site reqmt for mounting switches, sockets fan regulators etc including continuous earth wire PVC insulated 1.5 Sq mm FRLS copper conductor connecting to common earth and earth dolly complete all as specified :-
For one light point controlled by one switch complete all as specified and directed.
For one light point controlled by 2- two way switch complete all as specified and directed.
For one fan point controlled by one switch complete all as specified and directed.
For one 5 pin socket out let 5 amps on same bd complete all as specified and directed.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board complete all as specified and directed.
All as per item No 135 here in before but with cable 2.5 sqmm (nominal area) multi stranded copper wire unsheathed for one 5 pin socket out let 5 amps on independent board including continuous earth wire PVC insulated 1.5 sqmm copper multistranded conductor connecting to common earth and earth dolly complete.
Supply and fixing ceiling rose surface bakelite 3 terminals 65x50mm complete all as specified and directed.
S & F modular white cover plate with frame of 12/8 module complete all as specified and directed.
S & F modular white cover plate with frame of 06 module complete all as specified and directed.
S & F modular white cover plate with frame of 03 module complete all as specified and directed.
S&F Modular switch 1 way 06 amp single pole complete all as specified and directed.
S&F Modular switch 2 way 06 amp single pole complete all as specified and directed.
S & F modular switch socket combination 16A, 6 Pin of 3 module complete all as specified and directed.
S & F of modular socket outlet 6A-5 pin combined of 02 module complete all as specified and directed.
S & F of modular fan step regulator 120 W-2 module complete all as specified and directed.
S&F Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings incl LED Bulb 12W/14W complete all as specified and directed.
S&F Ultra bright LED Tubelight (single side connection) with very high efficacy suitale for Regal Batten for LED Tube (Single Side Connection) alongwith LED tube light of 22W including required length of 1.5 Sqmm PVC multistranded copper conductor ro electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. Make :- Wipro/Bajaj/Havells/Osram/Philips
S&F of 20W of LED security Light fixture with IP66 protected Die-Cast Aluminum housing and Heat resistive Toughened Glass. Driver shall be 3 stage Constant Current Constant Voltage with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60V DC. Make :- Wipro/Bajaj/Havells/Osram/Philips
M&L taking down fan, sealing cable end,dismantling the fan blades, cleaning the dust from fan and painting of ceiling fans complete in suitable with synthetic enamel paint by spraying including filling caviities with filler and deposit in E/M Store for refixing the same complete all as specified and directed.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten and making good the disturbed surface complete all as specified and directed.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLS multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLS copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
S&F in repair Sheet metal enclosure MCB DB, double door , 4 way TPN, 415 volts with 200 Amps rated bus bar with blanking plates wherever required and I.P. 43 degree protection complete all as specified and directed.
S&F, in repair, MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 42 degree protection complete all as specified and directed.
S&F, MCB TPN 63 Amps, 240 volts 'B' series 25 KA ,including connection with suitable size copper lugs including taking down the un serviceable MCB TPN complete all as specified and directed.
S&F, MCB SPN 40 to 63 Amps, 240 volts 'B' series 16 KA ,including connection with suitable size copper lugs including taking down the un serviceable MCB SPN complete all as specified and directed.
S&F, MCB SP 240 volts, 6 to 32 Amps, 'B' series 10 KA including connection with suitable size copper lugs including taking down the un serviceable MCB SP complete all as specified and directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area of size 35 Sqmm 3.5 Core complete all as specified and directed. Make : Finolex/Polycab/Gloster/Havells/RPG/Asian/Universal/KEI
Supply, installing, testing and commissioning of LT panel board 440 Volts, 4 wire, 3 phase factory fabricated powder coated, cubical, weather and vermin proof outdoor kiosk type, front opening, floor mounted made out of 3.15 mm thick CRCA sheet of size suitable for mounting the its accessories with electrolyte 4 Nos copper bus bar of capacity 400 Amp mounted on hygroscopic insulators and necessary electric connection of the equipment / accesories to be fixed, cable glands, lugs, mounted on steel angles supports of suitable size with grouting 4 Nos supports in PCC 1:2:4 type B1 complete with separate compartment for housing with proper arrangement for air circulation including taking down the existing metal/PVC box with the following accessories all as specified and directed (a) Electrolytic Copper bus bar 400 Amps in distant colour with epoxy supported insulators - 01 Job. (b) MCCB TPN, 160 Amps ,26 KA - 01 No (For incoming) (c) Amp Meter (0-100 Amp)- 01 Nos Make :AE (d) Volts Meter (0-500 Volts ) - 01 No Make :AE (f) ASS & VSS with CTs -02 Nos ( 01 Each) (g) MCB SP 63 Amps 'B' series, 230 volts - 5 Nos (For outgoing) (h) Nutral bus bar link mounted on insulator.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 70 Sqmm 3.5 Core complete all as specified and directed. Make of cable :- Finolex/Polycab/Gloster/Havells/RPG/Asian/Universal/KEI
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 25 Sqmm 4 Core complete all as specified and directed. Make of cable :- Finolex/Polycab/Gloster/Havells/RPG/Asian/Universal/KEI
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M & L High density polyethylene pipes (HDPE) 50mm dia of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and directed. Make :- Finolex/Supreme/ Prince.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe etc complete all as specified and directed.
lodhi builders
M/S Rajeev Construction
M/s Anjali Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .