Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹37.9 L+₹66,421.44 (1.78%)Rejected-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L2 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Dec 2020, 6:00 pmClosed
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
REPAIR TO ROOF EXT FACIAS PLASTERING PLINTH PROTECTION JOINERY RCC JALI INCLUDING PREVENTION OF LEAKAGE/ SEEPAGE AND OTHER MISC B/R WORKS OF 5 SIGNAL GROUP AND 500 (I) SIG COY SANJAY VIHAR AND OTHER ADJOINING AREA OF AGE B/R-II AND REPAIR/REPAC
2020_MES_394657_1
GE/C-58/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹80,000
Yes
22 Dec 2020
11 Nov 2020
9 Dec 2020
11 Nov 2020
7 Dec 2020
25 Nov 2020
11 Nov 2020 - 25 Nov 2020
Amount
M & L for providing, cement concrete type B0 (1:2:4) using 12.5 mm graded aggregates as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by Engineer-in-Charge.
Providing, cement concrete type B0 (1:2:4) using 12.5 mm graded aggregates as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, finished even and smooth complete all as specified and as directed by Engineer-in-Charge.
M & L for Brickwork with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in CM 1:4 including demolition of old brickwork complete all as specified and as directed by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
M & L for rendering 15mm thick on any faces of brickwork or concrete surfaces in CM 1:4 as in outer walls, chajjas, facias, fins etc finished even and smooth as a whole or in patches complete all as specified and as directed by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
M & L for rendering 15mm thick on any faces of brickwork or concrete surfaces in CM 1:4 as in outer walls, chajjas, facias, fins etc finished even and smooth as a whole or in patches including taking down old and damaged plaster complete all as specified and as directed by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
M & L for preparation of newly plastered external wall/ceiling surfaces of walls and applying two coats of weather proofing exterior acrylic emulsion paint premier quality on wall surface over one coat of primer applying 2mm thick wall care putty over from the same manufacturer complete all as specified and as directed by Engineer-in-Charge. upto a height of G+5
M&L for preparation of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vacuum mechanisum) having RPM not less than 1500, sanding pad of 80 grit having dia of 7''/9'' to make the surface free from dust, loose paint etyc or equivalent makes or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over priming coat premium quality on wall/ ceiling surface including applying 2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth and for above G+5 Buildings complete all as specified and directed. Note : Stage for Preparation of surfaces shall be got approved from GE before applying the finishes. Material shall be procured from manufacturer and work shall be got executed through authorised applicator complete all as specified and as directed by Engineer-in-Charge.
M & L for raking or cutting out joints/pointing and decayed mortar etc to brick work or brick tiles laid flat in floors, surface channels, roofs etc in cement mortar not less than 12 mm deep, washing the joints removing rubbing off premises, and keeping the surface to be pointed wet for 2 days prior to repointing or flush pointing to bricks laid flat or brick tiles in pavings / roof in CM 1:3 mixed with 5% crude oil by weight of cement complete all as specified and as directed by Engineer-in-Charge.
M & L for 40mm thick brick tiles laid on cement mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and as directed by Engineer-in-Charge.
M & L for GI tubing ISI marked including taking up and down medium grade 15 mm bore with all fittings and fixed complete to walls incl cutting chases and then making good the disturbed surface with cement plaster 1:4 or laid under floor including connection including taking up and down and dismantling of old GI tubing etc, complete all as specified and as directed by Engineer-in-Charge.
M & L for GI tubing ISI marked including taking up and down medium grade 20 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor including connection including taking up and down and dismantling of old GI tubing etc, complete all as specified and as directed by Engineer-in-Charge. Note : For pipes fixed on walls to be suitably clamped using stack clamps (rates inclusive in this item) of appropriate size @ appropriate distance apart for height of pipe) and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
S&F in repair Rotational moulded polythylene 1000 Ltr capacity water storage tank tripple layered WHITE (Cylindrical vertical with closed top )composite type or lid should be thread type) hoisted and fixed in position with 20mm dia brass float valve complete including ball valve and tank connection complete including dismantling of pvc tank complete all as specified and as directed by Engineer-in-Charge.
All as per item No 12 above but storage capacity 500 Ltrs complete all as specified and as directed by Engineer-in-Charge.
Taking down eaves gutters and rain water pipes (any size or pattern) including all fittings heads,shoes,bends,swan-necks,etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, waste and vent pipes in any length with or without ears, fixed in walls/floors/ trenches etc complete all as specified and as directed by Engineer-in-Charge. Note : For pipes fixed on walls to be suitably clamped using stack clamps (rates inclusive in this item) of appropriate size @ suitable distance apart for height of pipe) and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
S & F in repairs PVC (SWR) bends 110 mm dia complete all as specified and as directed by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge.
M & L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, incl hinging frames as necessary,gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290. Gde-E-165 complete all as specified and as directed by Engineer-in-Charge.
S & F galvanised heavy duty welded wire mesh fabirc wire cloth to be fixed to angle iron through proper nuts, bolts, welding etc complete all as specified and as directed by Engineer-in-Charge.
S & F heavy duty Harrison lock with 2 sets of keys complete all as specified and as directed (Min wt 300 gms) complete all as specified and as directed by Engineer-in-Charge.
M& L cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection 75 mm thick laid in bays and surfaces finished even and fair, including filling the joints with bitumen mastic including demolition of existing surface complete all as specified and as directed by Engineer-in-Charge.
M & L for 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats including taking down old shutters complete all specified and directed by Engineer-in-Charge. Note : Contractor will make his own arrangement for use of scaffolding, trestles, cradles, ladders etc necessary for execution of works upto any height; no extra payment for use of scaffolding, trestles, cradles, ladders etc will be made complete all as specified and as directed by Engineer-in-Charge.
S & F 4 mm sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane Note : Contractor will make his own arrangement for use of scaffolding, trestles, cradles, ladders etc necessary for execution of works upto any height; no extra payment for use of scaffolding, trestles, cradles, ladders etc will be made complete all as specified and as directed by Engineer-in-Charge.
S & F 100 mm brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed by Engineer-in-Charge.
S & F 100 mm medium weight MS butt hinges supplied and fixed,complete all specified and directed by Engr-in -Charge
S & F 125 mm Mild steel pressed handles, ovaltype, stove enamelled black complete all specified and directed by Engr-in -Charge
M & L for painting new or previously untreated wooden Surfaces of any description, not otherwise described, over 10cm width or girth with two coats of synthetic enamel paint over a coat of pink primer including prepration of wooden surface complete all specified and directed by Engineer-in-Charge.
S & F in repairs Stainless steel wire cloth.0.36mm nominal dia of wireand average width of aperture1.40mm and fixed withstainless steel wire staples complete all specified and directed by Engineer-in-Charge
M & L for providing precast cement concrete type B0 (1:2:4) using 12.5 mm graded aggregates as in louvres and jallies,not less than 25 mm thick (measured solid), including all mouldings including demolition of old broken jallies complete all as specified and as directed by Engineer-in-Charge.
M&L water proof treatment to RCC roof slab by providing 50 mm average thickness PCC 1:2:4 incorporting CONPLAST WL (water prooof compound) in the proportion as directed by the manufacturer and apply on damp PCC surface, first coat of Brush Bond RFX and again apply second coat of Brush Bond RFX after drying of first coat (average 1 - 1.5 mm thickness) and on completion, provide 25 mm thick PCC 1:2:4 mix (4 parts of 10mm nominal coarse aggregate, 2 parts of fine aggregate & 01 part of cement) cement concrete screed and then finsh the top sufurace even and smooth without using extra cement . The compete roof shall be tested by ponding of water for 24 Hrs complete all as specified and as directed by Engineer-in-Charge. Note :- Brush bond RFX liquid, powder and conplast WL shall be of FOSROC or equivalent in Star/Pidilite.
M&L for Preparation of old painted surfaces of steel of any description over 10 cms width or girth by using sand paper etc.for proper preparation and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5
M & L for Repairs to steel windows by straightning, welding of damaged portions, greasing & oiling to make funcitional like easy for closing and opening etc complete all as specified and as directed by Engineer-in-Charge.
S& F 35 mm thick flush shutters (factory made) solid core construction, with block board core and plywood face panel, commercial type on both sides. Flush shutters shall have teak wood edging as specified in IS (incl two nos 150 mm long extruded aluminium tower bolts, three nos 100mm long medium weight MS butt hinges, two nos 150 mm long extruded aluminium handles, one stopper and two nos 300 mm long Aluminum Sliding door bolts and two coats synthetic enamel paint along with one coat of pink primer), incl taking out and removal of old shutter complete all as specified and as directed by Engineer-in-Charge.
M&L for sealing/grouting around pipe penetration of toilets/kitchen/bathrooms core cutting in the following stages:- Supply and apply solvent Sikagard®-694 F (I) free, moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. . The moisture insensitive putty with Yield: 0.6 ltr/kg suitable for submerged condition; compressive strength of 40 N/mm2 (1 day) according to IS 9162-1979. The putty shall be applied to a groove thickness of minimum 20mm on pipe penetration joint to concrete as per direction of the Engineer-in-Charge.
Supply and apply bond coat with Sika® Latex Power to be prepared with Sika® Latex Power: Water: Cement = 1:4:8 @ 0.150 kg/sqm for 2 coats (1kg diluted Sika® Latex Power approximately covers 6-8 sqm in two coats depending on substrate) on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required and as per directions of Engineer-in-charge.
M & L for protection screed 1:2:4 in 50 mm thickness laid to be admixed with integral waterproofing compound Sika® Plastocrete Plus confirming to IS 2645 at the rate of 0.10 kg per bag of cement complete all as specified and as directed by Engineer-in-Charge.. Note : Integral waterproofing compound to be paid separately under appropriate item
Supply only integral waterproofing compound Sika® Plastocrete Plus confirming to IS 2645 complete all as specified and as directed by Engineer-in-Charge.
M&L for glazed coloured ceramic tiles (300x200mm) x6 to 7mm thick in dado etc set and jointed in neat cement slurry and pointed in coloured cement to match incl 10mm thick backing coat in cm 1: 4 incl dismantling old tiles complete all as specified and as directed by Engineer-in-Charge.
M&L for non skid coloured ceramic tiles (300x300mm) x6 to 7mm thick in floor etc set and jointed n neat cement slurry and pointed in coloured cement to match incl 15mm thick secreeding in CM 1 : 6 incl dismantling old tiles complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs mild steel chromium plated grating (round) 125mm dia fixed over floor/nahani trap (with hole or without hole) complete all as specified and as directed by Engineer-in-Charge.
S&F Cast iron floor trap 75 to 100mm dia including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs viterous china wash down water closet pan (Pedestal pattern) white incl 'P' or 'S' trap including making connection to flushing cistern, flushing pipe and jointing socket of flushing rim ( with and including rubber cone joint anti syphonage pipe joint to socket or stopper if anti syphonage pipe is not required and flushing rim connecton to nozzle pattern if require fixing of seat cover for pedestal pattern etc and making good the disturbed surface to match with the existing complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs plastic water closet seat cover white closed pattern with flat bottom and cover incl mild steel chromium plated hinging device complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 10 ltrs capacity PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, Aluminium brackets for bottom support fixing with gutties embeded in wall with drilling machine etccomplete all as specified and as directed by Engineer-in-Charge.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 46 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/Exh fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 48 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge,
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge .
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose surface PVC 65x50 mm type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
M&L in replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed by Engineer in charge.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixedcomplete all as specified and directed by Engineer in charge.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engineer in charge.
Supply and Fix in repair 35 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 25 mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete all as specified and directed by Engineer in charge.
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
S&F MCB DB SPN 02 way, single door 240 V AC 50Hz , with 10 Amps MCB SPN as incomer / out going complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
S & F in replacement exhaust fan 230 mm sweep, metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site complete all as specified and directed by Engineer in charge . Make : Orient /Bajaj/Havells
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and directed by Engineer in charge. . Make : Orient /Bajaj/Havells
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed by Engineer in charge.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls complete all as specified and directed by Engineer in charge. . Note: Three runs of 4 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls complete all as specified and directed by Engineer in charge. . Note: Three runs of 6 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls complete all as specified and directed by Engineer in charge. . Note: Three runs of 10 sqmm cable shall be measured as one RM.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl make good of disturbed surface complete all as directed by Engr-in charge.
S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for single switch 5 Amps complete all as specified and directed by Engineer in charge .
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L for disconnecting all the cable connection from indoor LT Panel and servicing to Panel board (Approximate size 1700mm x1300mm x 300mm) opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable copper wiring kit and burn out unserviceable extended copper terminals/copper cable and replacing with new copper extended terminal bus bar with suitable size along with required nut bolt, washers and cleaning with air blower to serviceable parts like MCCB's, all terminals, replacement of damaged aluminium/copper lugs any discription of LT UG cable/ copper wire incomming and out going, welding of broken door with suitable hinges, replacement of defective copper wiring with suitable copper conductor with circuit indiator replacement of defective rubber beading,writing various feeder complete all as specified and directed by Engineer in charge.
S&F hylum sheets 3 mm thick (ISI marked) of the following sizes :- Make :-As per sample.
Sheet 4" x 4" single cutting suitable for one piano switch
Sheet 4" x 4" two cuttings suitable for two piano switches
Sheet 4" x 7" three cuttings suitable for three piano switches
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
S &F capacitor 3.15 Mfd, 240 V complete all as specified and directed by Engineer in charge.
S&F capacitor 1 Mfd, 240 V complete all as specified and directed by Engineer in charge.
S&F hole fastner madeup of MS 6" long with complete all as specified and directed by Engineer in charge.
S&F hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
S&F heating element of 2 KW any type with nut bolt washer complete all as specified and directed by Engineer in charge. . Make-THEETA/BAJAJ/USHA
S&F heating element of 1.5 KW any type with nut bolt washer complete all as specified and directed by Engineer in charge. Make-THEETA/BAJAJ/USHA
S&F non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Engineer in charge.
S&F for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
S&F thermostat for 25/35/50 ltrs capacity of geysers complete all as specified and directed by Engineer in charge.
S&F SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washerscomplete all as specified and directed by Engineer in charge.
Note :- Total amount of Sch of credit is Rs. 62490.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S Sunil Steel Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .