| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.3 L+₹62,643 (3.76%)Rejected-AOC MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹18.8 L+₹2.1 L (12.8%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹19.9 L+₹3.3 L (19.7%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹20.9 L+₹4.2 L (25.5%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
19 Dec 2020, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
REPAIR MAINT OF INTERNAL ELECTRIFICATION IN CERTAIN OTM MD ACCN OF PB ENCLAVE ASHOK VIHAR JNE AREA AND ASC BN UNDER AGE EM OF GE NORTH UDHAMPUR
2020_MES_397444_1
GE/U(N)-66/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹44,000
Yes
5 Jan 2021
23 Nov 2020
21 Dec 2020
23 Nov 2020
19 Dec 2020
6 Dec 2020
Amount
Taking down carefully the existing Copper/Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr -in- charge. Note : (i) Old dismanteled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by engineer in charge.
Taking down Old Serviceable/unserviceable MCB DB any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by engineer in charge.
Point wiring for One light point controlled by one one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor HRFR insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia and1.5mm wall thickness ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.
Point wiring with 1.5 Sq. mm PVC Insulated unsheathed HRFR multistranded copper conductor, medium grade ISI meraked drwan into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drwan in to and including suraface PVC rigid non metalic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continious earth wire connected to common earth dolly complete all as specified and directed by engineer incharge.
All as per item No. 04 above but for bell / buzzer on independent board controlled by one push button bell switch.
All as per item No. 04 above but for one 5 Amps socket outlet on independent board.
All as per item No. 04 bove but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per item No. 04 above but controle by 2 Nos.of two way switch.
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
Point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLS) size 1.5 sqmm drawn in and incl PVC casing and caping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated backlite sheet complete all as directed by Engineer-in-charge.
All as per item No 11 above but for two way point wiring
All as per item No 11 above but for one 3/5 pin socket 5 Amp on same board.with cable1.5 sqmm size.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on independent board.with cable1.5 sqmm size.
All as per item No 11 above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
All as per item No. 11 above but for bell / buzzer on independent board controlled by one push button bell switch.
Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge
Switch Piano flush type single pole two way 5 Amps, all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body complete all as specified and directed by Engineer - in - Charge.
Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge
Switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge.
Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable light fittings any type as obtained against item No 2 all as specified and directed by engineer in charge
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 27
Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of MES Part-1 Fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the engineer incharge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continious earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 6 sqmm and one run 4 sqmm cable and one run of PVC conduit shall be measured as one RM
Switch Piano flush type single pole two way 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge
Switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge
Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge
Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Ceiling rose, 3 terminal, PVC / polycarbonet, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge.
Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge.
Fixing only serviceable MCB DB of any type and capacity obtained from Item No 03 complete all as specified and directed by engineer incharge.
In replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way all as specified and directed by engineer in charge.
In replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 Way all as specified and directed by engineer in charge.
Vertical three phase & Neutral (TP&N Vertical) Distribution Board 04 way Double door 415 volts grade IP 43 Protection Grade with provision for (MCCB) as incomming and Three/single phase (TP/SP) outgoings, complete with insulated bus bar arrangement fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr-in-charge.
Vertical three phase & Neutral (TP&N Vertical) Distribution Board 08 way Double door 415 volts grade IP 43 Protection Grade with provision for (MCCB) as incomming and Three/single phase (TP/SP) outgoings, complete with insulated bus bar arrangement fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr-in-charge.
Thermal magnetic MCCB 4 pole 100 Amps 415 Volts 16/18 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge
Thermal magnetic MCCB 4 pole 150/160 Amps 415 Volts 16/18 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge
Connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domesitc loads incl necessary copper lugs etc all as specified and as directed by engineer incharge. Make C&S Cat No: CSMBS2C40/ IndoAsian Cat No: 810078/ or equivalent makes to Standard
Supply fixing, connection and testing 'C' series MCB SP6-32 Amps all as specified and directed by engineer in charge
Supply fixing connection and testing 'C' series MCB SP 40 Amps all as specified and directed by engineer in charge
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
Modular fan step regulator 120W 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular switch 01 way 06A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge
Modular switch 01 way 16A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular bell push flush type 6A, 01 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular socket, 6A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceble one all as specified and as directed by engineer in charge.
PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 200x150x50mm deep including making necessary cutting all as specified and as directed by engineer in charge,s
PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 250x200x50mm deep including making necessary cutting all as specified and as directed by engineer in charge,
3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
Slim linear LED lighting fixture 4/5W watt LED batten, with full base of extruded poly carbonate isolated driver, complete making all connection from ceiling rose to fittings including testing complete all as per the direction of Engr-in-Charge. Make of LED -Syska Cat No:SSK-SQ0401/Wipro Cat No : D530565/C&S Cat No: LTTBIF5WLED/W/ Havells: Cat No: LHEXBXPNIN1W005 or equalvent in above specification as mentioned in description of any MES approved make
Slim linear LED lighting fixture 20 Watt LED batten, P.F greater than 0.9, input voltage range from 90 Volts to 280Volts with full base of polycarbonate extruded section acting as a heat sink with closed back isolated driver complete making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable with from ceiling rose to fitting complete all as specified and as directed by engineer in charge.Make Make : Syska Cat No: SSK-SQ2001/Havells Cat No: LHEXBXPNIN1W020/ or equivallent to Wipro or equalvent in above specification as mentioned in description of any MES approved make
LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing all as specified and directed by engineer in charge. Make Syska Cat No: SSK-BH-9W /Wipro Cat No : DA11265/Crompton :Cat No: LBHE-10-DL /Havells: Cat No: RUGBYNEONFT10WLED860SSYMTOPC or equalvent in above specification as mentioned in description of any MES approved make
Decorative ultra slim linear polycarbonate Extruded LED lighting fixture 10/12 Watt LED of input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K more than 1080 lumens of IP 20 complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceilingrose to fitting complete all as per directed by Engr-in-charge. Make Syska Cat No: SSK-SQ1201 Wipro Cat No : D531065/Havells: Cat No: LUMILINEPLUSBS10WLED865SPCSS/ Philips Cat No : BN 021 LED10S- 6500 PSU GR S1 or equalvent in above specification as mentioned in description of any MES approved make
S&F security (Street) light fitting 25 watt with input voltage AC 220V-240V, 50 Hz with colour tempetrature 6500K more than 2200 lumens of IP 65 new generation energy saving & environmental friendly long life versatile pressure die cast aluminium with acrylic powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughed glass, corrosion resistant, isolated driver including provision of GI tubing light grade bracket of suitable size and fixed on wall including clamps, nuts, bolts and washers for fixing of security/street light complete all as per specified and as directed by engineer in charge. Make: Syska Cat No: SSK-ST-25W-MG /Crompton :Cat No: LSTS-25-CDL/Havells Cat No: ENDURAPEARLSL25WLED757SASYTOPC/Wipro Cat Part No: LR02-291-XXX-57-XX or equalvent to above specification make as approved by MES
MCB TPN 63 Amp, 415 Volts- C curve of 10KA complete all as per specified and as directed by engineer in charge
S&F for Isolator 4 Pole 100 Amp, 415 Volts- complete all as per specified and as directed by engineer in charge
S&F for Isolator 4 Pole 125 Amp, 415 Volts- complete all as per specified and as directed by engineer in charge
Disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire complete all as specified and directed by engineer in charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paidseparately under relavent Items
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase all as specified and directed by Engineer in charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
Cutting of hard standing n.exc 45 Cm defth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing all as directed .
CITY 3 Decorative wall light fixture made up of polycarbonate, suitable for 15 Watt retrofit CFL/LED (B-22 Base) complete all as specified and as directed by engineer in charge.
Comet Round LED Round LED Panel al Die cast body with premium diffuser to ensure glare free & even distribution of light of 12 watt 6000K complete all as specified and as directed by engineer incharge.
LED light fitting PLUTO NEO PANEL 2x2 PLR 34 watt LED 857S environmental friendly , new generation , aesthetically designed ,ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for armstrong /grid /ceiling all as spesified and directed by Engr-in-charge Engr-in-Charge.
Rigid non metalic PVC casing capping of 25/12mm inclusive of elbow tees, etc fixed in repair complte all as per the direction of engineer in charge.
PVC Conduit medium grade 20mm dia ISI marked with all accessories such as Tees, elbows, junction boxes etc fixed in repair complete all as per the direction of Engineer in charge.
LED Garnet 18Watt PLL Lamp 4 pin type, 6500 K as per sample fixed in repair complete all as specified and as directed by engineer in charge.
Metal clad Plug socket single pole enclosure with two pin earth plug and socket with one single 20 Amp , 240 volts MCB complete all as specified and directed by engineer incharge.
RANBIR ENTERPRISES
DEV RAJ MAGOTRA
HIMALAYA ENTERPRISES
M/S BHARAT LIGHT ELECRIC.CO
MAHAJAN TRADING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .