Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹17.7 L+₹1.3 L (7.84%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹18.7 L+₹2.2 L (13.7%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹20.2 L+₹3.7 L (22.7%)Rejected-Finance | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 5 | L5₹22.5 L+₹6.1 L (37.2%)Rejected-Finance | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹49,500
Closing Date
29 Jun 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8778REPAIR MAINT OF INTERNAL ELECTRIFICATION FITTING FIXTURES AND CONNECTED ACCESSORIES AT TECH AREA DOMESTIC AREA TEMPORARY BLDGS OF EAST AREA UNDER GE M AF JALAHALLI
2023_MES_600435_1
8778/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹49,500
18 Aug 2023
2 Jun 2023
1 Jul 2023
2 Jun 2023
29 Jun 2023
16 Jun 2023
2 Jun 2023 - 9 Jun 2023
Amount
Taking down carefully copper/aluminum point wiring (light, fan,Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc removing to store for keeping in safe costody or for taking credit and making good disturbed surface of wall, floors , roof etc all as specified.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC casing&caping/conduit size of not less than 20mm on surface of wall including provn of PVC box of suitable size for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as per site requirement for One light point controlled by one switch one way 5 Amps all as specified and directed.
All as per item Srl No 2 above but One light point controlled by one two way switch 5 Amps
All as per item Srl No 2 above but One ceiling fan point controlled by one switch one way 5 Amps
All as per item Srl No 2 above but One Exhaust fan point controlled by one switch one way 5 Amps
All as per item Srl No 2 above but One call bell point controlled by one switch one way 5 Amps
All as per Sl Item no.2 but with One 2/3 pin socket outlet 5Amps on independent board
All as per Sl Item no.2 but with One 2/3 pin socket outlet 5Amps on same Board board
All as per item No 2 above but one switch socket combination 15 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
S&F switch piano flush type single pole one way 5 Amps
S&F switch piano flush type single pole two way 5 Amps
S&F ceiling rose surface bakelite 3 terminals 65x50mm
S&F Call bell push flush type single pole one way 5 Amps
S & F in repair stepped type electronic fan regulator flush type 100 Watts
S&F switch socket combination 2 in 1, 3 pin 5 Amps flush type
S&F Switch socket combination multipurpose 5/16 Amps, 5 in 1, 4 / 5 hole flush type
Supply & Fixing T-5 tube rod 28 watt.
Supply & Fixing tube rod T-5, 14 watt.
Supply & Fixing LED Retro bar tube rod 18/20 watt.
Supply & fix in repair decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 1X20 Watt 4 Feet.
Supply & fix in repair decorative recessed mounted ultra slim square profile 1X1 feet 20 W LED lighting fixture Squre shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 20 Watt and including cosidering material & labour for fixing ceiling hight upto 15 Mtr, all as per site requirement and directed by Engr-in-Charge .
Supply & fix in repair decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 1X10 Watt 2 feet
Supply and fixing Surface/recessed mounted LED luminaire 600 mm x 600 mm, 36/40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizeand including cosidering material & labour for fixing ceiling hight upto 15 Mtr complete.
Supply and fixing round shape 18/20 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing building security/ LED street light fitting 35 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete with IP 65/66 protection complete.
S&F in repair LED Lamp 9 watt including holder batten type as per site requirement complete all as specified and directed
Supply and fix in repair Modular switch 1way 6A,1module
Supply and fix in repair Modular socket, 6A-2/3 pin combined 2 module
Supply and fix in repair Modular switch, 16 A 1 module
Supply and fix in repair Modular socket, 6A/16A-2/3 pin combined 2 module
Supply and fix in repair Modular fan step regulator, 120w-2module
S&F in repair of switch socket combination 2 in 1, 3 pin 5 Amps flush type complete all as specified & directed.
S&F in repair of Switch socket combination multipurpose 15/16 Amps, 5 in 1, 4 / 5 hole flush type complete all as specified & directed.
S & F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc
S&F in repair Lamp holder angle type made of PVC/Polycarbonate with back plate.
S&F in repairs Plastic laminated Hylam sheet fixed for switch boards, MCB DB Covers etc cutting to suitable size including making slots for fixing swithces, sockets regulator,MCBs etc. & other purposes as required complete including replacement of rusted screws, nuts bolts accessories and connected items all as per site requirement, specified and directed by Engr-in-Charge.
S&F in repair of MCCB 125 amps 4 pole 16 KA 415 volt complete including taking down all as specified & directed.
S&F in repair of MCCB 100 amps 4 pole 16 KA 415 volt complete including taking down all as specified & directed.
S&F in repair of MCCB 63 amps 4 pole 16 KA 415 volt complete including taking down all as specified & directed.
S&F in repair, sheet metal enclosure distribution box suitable for MCB'S 4 way TPN 415 volts with 200 Amps rated bus bar double door complete including connecting up all as specified and making good distrubed surface
All as per item No. 40 above but 12 way SPN with 200 Amps rated bus bar , 240 volts
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10 KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TP 25 To 63 AMP current carrying capacity in the DB complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 25 To 63 AMP current carrying capacity in the DB complete with connection testing and commissioning.
Taking down sub main wiring of any size complete all as specified and directed.
M&L for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 4 sqmm copper conductor cable as earth conductor of 4.0 sq mm and conduit accessories fixed up in surface including connecting up complete all as specified and directed.
All as per item no 47 but cable size of 6.0 sqmm
M&L for sub main wiring with Four single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor of 6.0 sqmm and conduit accessories fixed up in surface including connecting up complete all as specified and directed.
All as per item no 40 but cable size of 10.0 sqmm Note for item No 46 to 49 :-Two/four run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Taking down ceiling fan of any size, type and make after disconnecting the electrical connections, cleaning, servicing , greasing removing and replacing all the unserviceable spare and re-fixing the same back to the original location all as directed Note: (i) The rate quoted shall be deemed to include the cost of painting and spares such as split pin , clamp, screws washers etc.
Taking down Exhaust fan/fresh air fan of size 250/300/350 mm of any type & make after disconnecting the electrical connections ,cleaning, servicing , greasing removing and replacing all the unserviceable spare re-fixing the same back to the original location all as directed. Note: (i) The rate quoted shall be deemed to include the cost of painting and spares such as split pin , screws washers etc.
Supply only Capacitor 2.5 mfd for ceiling fans.
Supply only Capacitor 4 mfd for exhaust fans.
Supply only the mounting clamps and rubber bush with nut, bolt, washers, locking clip etc complete suitable for fixing at the down rod suitable for fixing the ceiling fan.
Supply only twin core flexible wire 1 Sqmm for connecting up ceiling fans, exhaust fans/wall mounting fan etc.
Taking down old burnt out copper winding wire from ceiling fan of 1200/ 1400 mm sweep and rewinding by using same gauge of copper wire insulating and varnishing,heating, cleaning, servicing,greasing,refixing at site,testing, commissioning for smooth functioning complete all as specified & directed.
Taking down old burnt out copper winding wire from fresh air fan/exhaust fan of 230/300 mm sweep and rewinding by using the same gauge of copper wire super enameled including heating and varnishing,cleaning, servicing,greasing, cement work refixing at site and testing commissioning for smooth functioning complete all as specified & directed.
Supply & fixing Louver Metel Body for exhaust fan upto 450 MM sweep fix out side of exhaust fan hole on wall up to hight of 15 Mtr/GF/FF/SF with fixing accessories complete all as per site requirement and specified by Engr-in-Charge.
M/S SRI BALAJI ENTERPRISES
Sai Ram Builders
eurekaenterprises
MBN Enterprises
CITIZEN ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .