Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAdmitted-Finance HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | ₹7.7 L | L1 | Admitted-Finance |
| 2 | L2₹10.1 LAdmitted-Finance NEAR CENTRAL JAIL LAXMI NAGAR P S RAMPUR DISTT GAYA PIN 823001 BIHAR | GAYA | GAYA | BIHAR | 823001 | ₹10.1 L | L2 | Admitted-Finance |
| 3 | L3₹10.5 LAdmitted-Finance MAGADH COLONY ROAD NO 6 SHERGHATI ROAD GAYA BIHAR 823001 | GAYA | GAYA | BIHAR | 823001 | ₹10.5 L | L3 | Admitted-Finance |
| 4 | L4₹11.0 LAdmitted-Finance 1 7356 GALI NO 11 EAST GORAKH PARK SHAHDARA DELHI SHAHDARA DELHI 110032 UDYAM DL 07 0014995 | SHAHDARA | DELHI | 110032 | ₹11.0 L | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S CHAUHAN CONSTRUCTION L1 | SINGHAL ENTERPRISES L4 | M/S ASHOK KUMAR L2 | M/S AJAY KUMAR SINGH L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive preventive & routine maintenance services of 1.5 TR window type air conditioner Make: Voltas/LG /Carrier/Blue Star or any other make on site installed at various location in the station by carrying out following checks and services:- (i) Cleaning of condenser and evaporator coils fins with mild detergent/chemical solution for descaling of coils and flushing with high-pressure jet of water after taking down the whole unit and refixing at the existing location or any other new location after servicing. (ii) Greasing of blower motors and all moving parts. (iii) Prevention of rusting of units (iv) Checking operation of controls of the air conditioner such as thermostat, relays, remote control etc. (v) Checking air flow through the supply air grill, return air grill, condenser. (vi) Checking air temperature at supply air grill, return air grill, inlet air condenser, outlet air from condenser. (vii) Checking firmness of supporting arrangement for the compressor, blower motor, air conditioners casing and fixing of air-conditioners etc., anti-rusting painting of the MS portion prone to rusting. (viii) Replacement of any component of air conditioners found defective after the above checks and tests | 10 | Each Job | 1,000 ₹10,000 | 850 ₹8,500 | 1,000 ₹10,000 | 625 ₹6,250 Lowest |
| 2.00 | All as per item No. 1 above but for 1.5/2 TR split type air conditioner.
Note for Item No. 1 & 2, (i) Cleaning, overhauling and servicing of each unit shall be carried out on quaterly basis. (ii) The AC units shall be checked completely and serviced/repaired thoroughly at least once in three months as prescribed by the manufacturer of the AC units. In addition to this AC units shall be attended on break down with in 24 hours after intimation and shall be get repaired with in 48 hours, failing which necessay recovery @ Rs 200 per AC per hrs shall be made. (iii) Items/parts required for repair/replacement shall be measured and paid separately under relevent items here-in-after as supply and fixing. | 110 | Each Job | 800 ₹88,000 Lowest | 800 ₹88,000 Lowest | 1,000 ₹1,10,000 | 800 ₹88,000 Lowest |
| 3.00 | S & F in repair refrigerant copper piping of size 1/4" internal dia in and including synthetic rubber foam insulation for split type AC complete all as specified and directed. Note: The quoted rate is inclusive of necessary T&P, rope, ladder etc with safety equipment for execution the work upto G+ one storie building. | 30 | RM | 350 ₹10,500 | 350 ₹10,500 | 550 ₹16,500 | 345 ₹10,350 Lowest |
| 4.00 | All as per item Srl No. 3 above but for 1/2" internal dia pipe. | 30 | RM | 300 ₹9,000 | 280 ₹8,400 | 550 ₹16,500 | 239 ₹7,170 Lowest |
| 5.00 | Disconnecting, dismantling and taking out existing burnt out compressor from window/split type Air conditioner 1.5 TR Capacity and supply & fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil complete all as specified by Engr-in-Charge and testing on load for 24 hrs in summer complete all as specified and directed. | 5 | Each | 8,000 ₹40,000 | 10,000 ₹50,000 | 7,000 ₹35,000 Lowest | 8,500 ₹42,500 |
| 6.00 | All as per item No. 5 above but for 2 TR window/split type air conditioner complete all as specified and directed.. | 2 | Each | 8,000 ₹16,000 | 12,000 ₹24,000 | 7,000 ₹14,000 Lowest | 9,595 ₹19,190 |
| 7.00 | S & F in repair copper condenser motor suitable for 1.5 / 2 TR split type AC of any make/ model complete all as specified and directed. Make: As per existing make | 8 | Each | 1,500 ₹12,000 Lowest | 6,500 ₹52,000 | 2,000 ₹16,000 | 4,595 ₹36,760 |
| 8.00 | S & F in repair starting capacitor of 80 to 100 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC complete all as specified and directed | 12 | Each | 700 ₹8,400 | 500 ₹6,000 | 500 ₹6,000 | 490 ₹5,880 Lowest |
| 9.00 | S & F in repair running capacitor of 36 to 45 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC complete all as specified and directed. | 12 | Each | 500 ₹6,000 Lowest | 525 ₹6,300 | 500 ₹6,000 Lowest | 700 ₹8,400 |
| 10.00 | S & F in repair blower motor double shaft, single/double speed, single phase, AC 230 V of 1/6 to 1/4 HP capacity to suitable for window type AC complete all as specified and directed. Make: As per existing make | 4 | Each | 4,000 ₹16,000 Lowest | 5,050 ₹20,200 | 4,000 ₹16,000 Lowest | 4,995 ₹19,980 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Jul 2026, 6:00 pmClosed
Garrison Engineer Gaya
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar, PIN-823005
REPAIR MAINT OF SUMMER AND WINTER APPLIANCES, GEYSERS, SOLAR WATER HEATER AND CONNECTED WORKS AT OTA GAYA
2026_MES_771996_1
8049/GE/26-27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OTA Gaya
Please ref tender documents
7 documents required · 7 mandatory
₹500
GE Gaya
₹30,000
23 Jul 2026
13 Jun 2026
21 Jul 2026
13 Jun 2026
16 Jul 2026
27 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive preventive & routine maintenance services of 1.5 TR window type air conditioner Make: Voltas/LG /Carrier/Blue Star or any other make on site installed at various location in the station by carrying out following checks and services:- (i) Cleaning of condenser and evaporator coils fins with mild detergent/chemical solution for descaling of coils and flushing with high-pressure jet of water after taking down the whole unit and refixing at the existing location or any other new location after servicing. (ii) Greasing of blower motors and all moving parts. (iii) Prevention of rusting of units (iv) Checking operation of controls of the air conditioner such as thermostat, relays, remote control etc. (v) Checking air flow through the supply air grill, return air grill, condenser. (vi) Checking air temperature at supply air grill, return air grill, inlet air condenser, outlet air from condenser. (vii) Checking firmness of supporting arrangement for the compressor, blower motor, air conditioners casing and fixing of air-conditioners etc., anti-rusting painting of the MS portion prone to rusting. (viii) Replacement of any component of air conditioners found defective after the above checks and tests | 10 | Each Job | - | - |
| 2 | All as per item No. 1 above but for 1.5/2 TR split type air conditioner.
Note for Item No. 1 & 2, (i) Cleaning, overhauling and servicing of each unit shall be carried out on quaterly basis. (ii) The AC units shall be checked completely and serviced/repaired thoroughly at least once in three months as prescribed by the manufacturer of the AC units. In addition to this AC units shall be attended on break down with in 24 hours after intimation and shall be get repaired with in 48 hours, failing which necessay recovery @ Rs 200 per AC per hrs shall be made. (iii) Items/parts required for repair/replacement shall be measured and paid separately under relevent items here-in-after as supply and fixing. | 110 | Each Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
8049Tenderdocuments.pdf
Tender Documents • 0.97 MB
BOQ_864462.xls
BOQ • 3.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].