| 1 | L1₹72.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹78.7 L+₹5.5 L (7.49%)Rejected-Finance 162 MAYUR VIHAR SECTOR 48 A CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | 160047 | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
29 Jun 2021, 3:00 pmClosed
Incharge Civil
Verka Head Office
Additions/ Alterations in the existing Fermented Dairy Building for setting-up Yoghurt Plant and Construction of Under Ground Storage Reservoir (2.00 Lacs Ltr Capacity) for Fire Fighting System at Verka Mohali Dairy.
2021_Coop_66488_1
PSF/Civil/8844-64
Open Tender
Civil Works
Item Rate
180 days
Verka Head Office
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹1.5 L
24 Sept 2021
4 Jun 2021
30 Jun 2021
4 Jun 2021
29 Jun 2021
4 Jun 2021
Amount
Dismantling/removing of existing Aluminium/ M.S. glazing/window/ ventilator (fixed/ openable) alongwith M.S. hold fasts embedded in cement concrete and hoop iron bars from the wall/ between the columns etc. including removing of glass panes and returning to the stores as directed including finishing the broken surface to match with the existing as per site requirement above 1st storey complete in all respects as directed by the E-in-C.
Dismanteling of existing Brick bat coba work on terrace including removal of debris and disposal of same within site campus and cleaing of surface above 1st storey complete in all respects as directed by the E-in-C.
Dismantling of reinforced cement concrete for all types of R.C.C. work including cutting of reinforcement and finishing the broken surface to match with the surrounding above 1st storey and removing the debris from site of work to dumping ground/yard - approved by the M.C., Mohali ,as directed by the E-in-C.
Dismantling of existing Brick work/ tile masonry in cement mortar, above 1st storey as per actual site conditions/ requirements, finishing the broken surface to match with the surrounding, removing the debris etc. from site of work to dumping ground/yard - approved by the M.C., Mohali , Including cutting the reinforcement if any and cleaning & stacking of dismantled bricks and bats for re-use in new work, complete in all respects as directed by the E-in-C.
Dismantling of existing Unitile brick tiles from façade of building including required scaffolding, removal of debris above 1st storey and disposal of same within site campus and cleaing of surface complete in all respects as directed by the E-in-C.
Providing re-barring treatment (Chemical Anchoring, Make Hiltie) of desired dia in RCC with required hole size and depth as per CSR specifications with 10ml injectable mortar epoxy adhesive ( Hybrid urethane methacrylate adhesive ) rebarring chemical complete in all respect as directed by E-in-C.
a) For 10mm dia steel reinforcement bars.
b) For 12mm dia steel reinforcement bars.
c) For 16mm dia steel reinforcement bars.
d) For 20 mm dia steel reinforcement bars.
e) For 25 mm dia steel reinforcement bars.
Providing jointing of old steel bars and new with fillet welding of minimum 100 mm length for extension of steel bars for new cols .Complete in all respects as directed by the E-in-C.
Earth work in excavation for storage tanks, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. With 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 3rd chain complete in all respect.
Earth work in excavation for all type of foundations, footings, trenches, etc. in all kinds of soil where pick-jumper work is not involved and not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent refilling around masonary/concrete etc. in 15cms layers with compaction/ consolidation, including disposal of all surplus soil as directed, within campus / site.
Providing and laying plain cement concrete 1:4:8 using concrete mixture volumetric type with stone aggregate (1 cement: 4 coarse sand: 8 stone aggregate 40mm gauge) for all types of foundations, footings, below rafts, extension columns, plinth beams/under floor etc. including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C.
a) upto a depth of 4 metres below road level .
Providing and laying plain cement concrete 1:5:10 using concrete mixture volumetric type with stone aggregate (1 cement: 5 coarse sand: 10 stone aggregate 40mm gauge) for all types of foundations, footings, below rafts, extension columns, plinth beams/under floor etc. including spreading, laying, ramming and consolidating as per requirements and curing etc. but excluding centering and shuttering, complete in all respects as directed by E-in-C in Super Structure above first roof level up to height of 8 meters.
Providing and fixing steel shuttering for faces of all type of concrete foundations, footings, strips, pedestals, foundation beam, plinth beams (vertical, or battering) and columns etc. Complete in all respects as directed by E-in-C.
a) upto a depth of 4 metres below road level .
Providing and fixing steel shuttering and centering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc. Complete in all respects as directed by the E-in-C.
upto a depth of 4 metres below road level .
Providing and fixing steel shuttering and centering for RCC columns (square or rectangular). Complete in all respects as directed by E-in-C.
a ) In Super Structure up to 4 meters height.
b ) Above first roof level upto 8m height.
Providing and fixing steel shuttering and centering for sides and soffits of beam, beams launchings girders bressumers, lintels etc. Complete in all respects as directed by E-in-C.
a) In Super Structure up to 4 meters height.
b ) Above first roof level upto 8m height.
Providing and fixing steel shuttering and centering for flat surfaces such as suspended floors, roof, landings, chajjas, shelves. Complete in all respects as directed by E-in-C.
a ) In Super Structure up to 4 meters height.
b ) Above first roof level upto 8m height.
Providing and fixing steel shuttering and centering for corbels, parapet, facias and other similar items including edges . Complete in all respects as directed by E-in-C.
a ) Above first roof level upto 8m height.
Providing and fixing steel shuttering and centering for stair cases with sloping with soffits etc. Complete in all respects as directed by E-in-C.
a ) In Super Structure up to 4 meters.
Providing and fixing/placing in position Ribbed/Tor/T.M.T. Steel Bars, for R.C.C. works, where not including in the complete rate of R.C.C. included bending, binding and placing in position as per structural design/ drawing including cost of binding wire. Complete in all respects as directed by the E-in-C.
a ) In Super Structure up to 4 meters.
b) Above first roof level upto 8m height.
Providing & laying Reinforced cement concrete M-30 mechanically mixed using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, footings, strips, pedestals, tie beams & plinth beams etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating &curing etc., Complete in all respects as directed by the E-in-C.In foundation and upto plinth level.
a) upto a depth of 4 metres from ground level.
Providing & laying Reinforced cement concrete M-25 mechanically mixed using batch type concrete mixture as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering, for all types of RCC works i.e. column, beams, slabs and fascias etc. as per structural drawings/ design including laying, spreading, ramming, watering, consolidating & curing etc., Complete in all respects as directed by the E-in-C.
a) In Super Structure up to 4 meters height.
b) Above first roof level upto 8m height.
Providing & constructing Ist Class burnt brick work laid in cement sand mortar 1:6 (1 cement: 6 coarse sand) including scaffolding, watering, curing etc. complete in all respects, as directed by the E-in-C.
a) In foundation and plinth
b. In Super Structure up to 4 meters height.
c). Above first roof level upto 8m height.
Providing and applying cement plaster of 10mm thick in cement mortar 1:3 on inner side of basement walls etc. Complete in all respects for all heights as directed by the E-in-C.
Providing and applying cement plaster in cement sand mortar 1:4 (1cement: 2 fine sand: 2 coarse sand) to the walls, columns etc. including providing groove, drip course, scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.In Super Structure above the first storey
a) 10mm thick for all heights.
Providing and applying cement plaster on under side of ceiling 10mmm thick in cement sand mortar 1:4 (1cement: 2 fine sand: 2 coarse sand) including scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C.
a. In Super Structure up to 4 meters height.
b) Above first roof level upto 8m height.
Providing and applying cement plaster in cement sand mortar 1:5 (1cement: 2.5 fine sand: 2.5 coarse sand) to the walls, columns etc. including providing groove, drip course, scaffolding, finishing, curing etc. Complete in all respects for all heights as directed by the E-in-C. A) In Super Structure up to 4 meters height.
i) 12.5mm thick
ii). 20 mm thick in 2 coats work.
B) Above first roof level upto 8m height.
i) 12.5 mm thick.
ii). 20 mm thick in 2 coats work.
Water proofing of roof terraces, Basements,Retaining Walls, Water tanks etc with Zydex Zycoprime / Elastobar / Equivalent solution so as to form a water-resistant cementitious bonding coat and to form on-site seamless cross-linked elastomeric membrane on the concrete surface to reduce its porosity. Creating a cementitious elastomeric polymeric membrane of Elastobar and Zycoprime/Equivalent after application of Zycosil & Zycoprime Solution in New Construction. Take equal parts of Elastobar and Cement and form a paste. Add little water to the paste to make it brushable. Apply the paste on surface with brush. Leave the surace for drying for at least 4 - 6 hours to get elastomeric membrane. After this application, make one more layer of rough cementatios membrane using mixture of 1 Part of Zycoprime + 1 Part of Cement + 1 Part of fine sand. Apply paste on the surface with a brush to make a rough texture. Now your surface is ready to bond well with tiles/screed.Complete in all respects as directed by E-in-C.
Providing and laying terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing, complete in all respects as directed by E-in-C.
a ) In Super Structure up to 4 meters height.
b) Above first roof level upto 8m height.
Providing and laying cement pointing 1:2 flush on flat brick flooring complete in all respects as directed by E-in-c
Providing and laying cement concrete 1:2:4 gola 10cm. X10cm. concave quadrant along junction of roofs with parapet wall, finished smooth where specially specified, complete in all respects as directed by the E-in-C.
a. Providing and fixing/embedding PVC rain water pipe of 2.5kg. / Sqcm. make DIPLST/ FINOLEX /SUPREME including jointing with solution and providing and fixing necessary specials etc. Complete in all respects to the entire satisfaction of E-in-C.
a.) PVC rain water pipe 110mm o/d
b.) PVC rain water pipe 160mm o/d
Providing and fixing in position stainless steel jali made from SS flat and angle as per design complete in all respects
Providing and fixing C.I. grating 100mm dia for rain water pipe. Complete in all respects as directed by the E-in-C.
Providing and constructing Top khurra 0.6M x 0.6M for Rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16, complete in all respects as directed by the E-in-C.
Providing and constructing Bottom khurra on ground 1.2M x 0.6M consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3 complete in all respects as directed by the E-in-C.
Providing and fixing special floor traps (S.S Amul Trap) in position as per drawing detail and as directed proprly connected to drainage pipes and ensure leakproof at any point. The wt. Of trap shall be 10-12 kg including jointing with epoxy sealent and concrete as directed by the E-in-C complete in all respects.
Providing and cutting RCC with mechanical core cutting machine as per design,repairing the edges and making the sides good to match the existing surface complete in all respects
a ) 100mm dia
b ) 150mm dia
c ) 200mm dia
d ) 250mm dia
e ) 300mm dia
Providing and laying Mandana stone tile flooring 20mm to 30 mm thick (to be got approved before fixing) keeping groov of 20 mm thick base of cement mortar 1:3 (1 cement, 3 Sand) laid and jointed filling of grove with epoxy chemical, mixed with pigment to match the shade of stone including rubbing and polishing, complete in all respects as directed by the E-in-C.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Gloss/Highly gloss/Highlighter/emboss confirming to IS : 15622 600x300 mm (to be got approved before fixing) in skirting, risers of steps, dado walls and pillars fixed over in 12mm thick cement mortar 1:4 (1 cement 4 coarse sand) and joint and jointing with grey cement slurry and pointing with white cementmixed with pigment to match the shade complete in all respects as directed by the E-in-C.
Providing and fixing UNI-Brick tiles smooth size 230x60mm, 12mm thick (Red Colour) of Unistone or equivalent, clading on walls, (design/make to got approved before arranging) in specified pattern laid in 12.5 mm thick cement sand mortar 1:3(1 cement and 3 sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone tiles , including rubbing and polishing wherever required complete in all respect as directed by the E-in-C
Providing and laying Kota stone tile flooring 20mm to 30 mm thick (to be got approved before fixing) over 12.5mm thick base of cement mortar 1:3 (1 cement, 3 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing, complete in all respects as directed by the E-in-C.
Providing and laying Kota stone tiles 20mm thick (to be got approved before fixing) in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing, complete in all respects as directed by the E-in-C.
Providing and applying 2-3 coats of Birla /Acrylic putty wherever required with smooth finished Complete in all respects as directed by the E-in-C.
Providing and applying 2-3 coats of special quality plastic emulsion paint of approved manufacturer on ceiling, walls and other surfaces evenly to produce even surfaceand finished smooth . Complete in all respects as directed by the E-in-C.
Finishing walls with textured exterior paint of ( rustic design) required color and shade of approved make with two coats applied @ 3.28 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm Complete in all respects as directed by the E-in-C.
Finishing walls with exterior silicon additive paint of required color and shade of approved make with two coats applied @ 3.28 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm Complete in all respects as directed by the E-in-C.
Extra for providing and mixing water proofing compound (where not included in the rate of above said/ relevant items) ISI marked and to be got approved from the E-in-C before use. Mixed in ratio of one Ltr. WPC Per Bag of cement/ as per manufacturer’s guideline complete in all respects to the entire satisfaction of E-in-C.
Providing and fixing aluminium work colour coated and approved shade, for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :
a) For fixed portion and chaukhats
b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and necessary Alumn. fittings wherever required including the cost of PVC Plug / neoprene gasket etc. complete in all respects as directed by the E-in-C.
Extra for providing and fixing 4 mm thick ACP sheet( Make Alstone/Alucobond or equivalent )of desired color on both side complete as per architectural drawings and directions of engineer-in-charge. Complete in all respects as directed by the E-in-C.
Extra for providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading is included in the basic item)
a )Float glass pane of 5 mm thickness.
Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together throughtheir entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) including a primimng coat and 2 coats of Ist quality Enamel paint of desired colour.
Providing and fixing stair case railing made out of M.S. Square box pipe 40x40mm as vertical post 1.0 metre high fixed with M.S. Base plate of 50mx50mmx6mm and MS square box pipe 40mmx40mm as hand rail including a primimng coat and 2 coats of Ist quality Enamel paint of desired colour.complete in all respects.
Providing and laying 2’-6’’ wide plinth protection consisting of 2’-3’’ wide brick on edge laid in cement sand mortar 1:4 on 75mm thick cement concrete 1:8:16 and 100mm thick sand filling and cement pointing 1:2 on top including excavation re-filling and disposal of surplus earth within campus.
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mmx 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggregate) complete as per design
Providing and laying 80mm thick cement concrete interlocking paver block of M-40 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design/shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick complete in all respects as per specifications and to the entire satisfaction of E-In-C.
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: MAKE- Havells, Legrand/approved Wiring in PVC insulated copper conductor single core FR cable (ISI marked), 1100volts grade to be laid in heavy gauge, PVC, fire retardant conduit pipe 20mm/25mm dia. (2mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules, for having electronic fan regulators, bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20Amp. Sockets and 6Amp./16/20Amp. Switches (Screw Type Modular Accessories) etc., and covered with Frame Plate etc., & including the cost of required number of modular switches/sockets, step type electronic fan regulator 100watts, PVC connector (For Fan Box and Electronic Buzzer), Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) PVC conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of changes. Complete in all respects as directed by E-In-C.
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm,1100volts grade. with single control switch.
Wiring Fan point- controlled by one switch in PVC insulated copper conductor single core FR cable (ISI marked to the approval of E-in-C). overall 1.5 sq. mm, 1100volts.
Wiring 3 Pin 6 Amp. Plug control comprising wall socket(shuttered) and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete.
Wiring 3 pin 16/20 amp. power plug control (shuttered) and switch.
Wiring TV sockets and Telephone socket points in powder coated/anodized concealed metal boxes recessed in wall/under floor required for suitable number of modules, for having TV sockets, Telephone sockets RJ11 & RJ45 (one module) etc., and covered with Frame Plate etc., & including the cost of required number of modular TV sockets, Telephone sockets RJ11 & RJ45 (one module) and other petty material etc. including the cost of cutting and filling up of chases complete as directed by the E-in-C.
a) Wiring Telephone socket point (one module) including Telephone Jack RJ - 11.
Supplying and erection of P.V.C. insulated single core FR copper conductor cable (ISI marked - to the approval of E-in-C) left bare in pipe or casing of suitable size, excluding the cost of supply and erection of pipe or casing. Complete in all respects. Note:- (Extra rate will be payable only beyond the individual point’s control panel/ board to main D.B. panel)
a) PVC insulated copper conductor single core FR cable overall 1 sq.mm, 1100volts grade.
b) PVC insulated copper conductor single core FR cable overall 1.5 sq.mm, 1100volts grade.
c) PVC insulated copper conductor single core FR cable overall 2.5 sq.mm, 1100volts grade
Supply and fixing single pole blanking plate in the switch board complete as directed by the E-in-C
Supplying and erection of Miniature circuit breaker (MCB’s) single pole 6 to 32 amp (Breaking capacity 10 kA, Curve-C) suitable for 240/415 volts 50 cycles AC supply, to be fixed in the new/ existing MCBD’s including necessary connections, testing and commissioning etc. complete in all respects as directed by the E-in-c. Make Havells/ Legrand/ Schneider or equivelant approved
a) 6 to 32 A SP MCB
b ) MCB Double Pole 6-32amp. (10kA, Curve-C)
c ) MCB Four Pole 6-32amp. (10kA, Curve-C)
d ) MCB Four Pole 40amp. (10kA, Curve-C)
Supply and erection of sheet metal double door distribution boards of suitable size and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the existing MCB distribution board as per PWD General Specifications 2010 including connections with suitable size of thimbles and bonding to existing earth etc. GROUP-A: (Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) & Schneider (Neo Break), L&T (EXORA), Hager.
a) Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's,12 way each complete in all respects.
b) Sheet metal double door S.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 8 way each complete in all respects.
c) Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 4 way each complete inall respects.
d) Sheet metal double door T.P. & N. distribution board (dust protected) provided with bus bar, neutral link and din bar, suitable for incorporating MCB's/ RCBO/ RCCB's, 8 way each complete in all respects.
SUPPLY AND FIXING OF LIGHTING LUMINARIES CONSISTING OF LIGHTING FIXTURES. ALL INTERCONNECTED WIRING. MAKE PHILIPS/WIPRO /HALONIX/SYSKA OR EQUIVALENT MAKE APPROVED BY THE E-IN-C BEFORE FIXING, DETAILS GIVEN UNDER:- 50-60 wattshigh power led fixture , rectangular shape, IP65, P.F .92 to .95 ,5000lumens, 170-260 volts
Supplying and Erection of heavy gauge PVC conduit pipe, fire retardant for wiring purpose - 25mm dia (ISI marked recessed in wall/ on surface) of an approved quality. Including the cost of bends, sockets, inspection boxes etc. complete in all respects as directed by the E-in-C. Note:- (Extra rate will be payable only beyond the individual points control panel/board to main D.B. panel).
rattan builders pvt ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .