Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹26.3 L+₹3.6 L (15.7%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹29.7 L+₹6.9 L (30.4%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹33.5 L+₹10.8 L (47.2%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
15 Sept 2021, 6:00 pmClosed
Maj Pramod Kumar Tripathi
GE (South) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
REPAIR TO ALL TYPE ROOF, ROOF TREATMENT, CEILING, AND OTHER MISC WORK AT AGE B/R AURANGABAD UNDER GE(S) AHMEDNAGAR
2021_MES_469456_1
8809/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AURANGABAD
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹60,000
Yes
6 Oct 2021
19 Aug 2021
17 Sept 2021
19 Aug 2021
15 Sept 2021
1 Sept 2021
19 Aug 2021 - 24 Aug 2021
Amount
Excavating in post holes (or similar holes) in soft/loose soil each nexc 0.5 Cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface all as specified and as directed.
Demolition of precast reinforced cement concrete manhole covers set in cement mortar etc complete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete (reinforcement to be measured and paid separately) all as specified and as directed.
M&L for plain cement concrete 1:3:6, type C-2 using 40mm graded stone aggregates as in foundations, filling and mass-concrete all as specified and as directed.
M&L in repairs, 35mm thick precast cement concrete , Type B0, 1:2:4 (12.5mm graded aggregates) as in louveres and jallies (measured solid), including all mouldings but excluding frame set in cement mortar 1:6 all as specified and as directed.
M&L for precast cement concrete 1:3:6, type C1 (using 20mm graded aggregate) as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, plastes, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfered, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match all as specified and as directed.
M&L for plain cement concrete, 1:3:6, type C-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edge including anchorage/bed blocks for hold fasts complete all as specified and as directed.
Demolition of brickwork masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M&L for brick work with old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
All as per serial item No 9 but except bricks Note : Old bricks obtained from item No 8 shall be reused.
Dismantling timber scantling 40 Sq.cm and over in section, in any position all as specified and as directed.
Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in section, in any position all as specified and as directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced not exc 15 cm all as specified and as directed.
M&L for second class hard wood clean sawn in scantling timber fixed all as specified and as directed.
All as per serial item No 14 above but but except timber
M&L for second class hard wood plain fillets, square, rectangular or traingular in secction, clean sawn, secured with nails sectional area exc 13 Sqcm but n.exc 25 Sqcm all as specified and as directed.
All as per serial item No 16 above but except fillets
M&L for second class hard wood batten, clean sawn at spacing 15cm centre to centre, cross sectional area exc 5 Sqcm but n.exc 15 Sqcm all as specified and as directed.
All as per serial item No 18 above but except battens
M&L for 20mm thick second class hard wood timber boarding,clean sawn, fixed with nails in any situation with butt joints, including dismantling old timber boarding all as specified and as directed.
M&L for rolled mild steel in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections conforming to Fe 410-W(Gde-E250) quality A) including distance pieces, cleats etc. all as specified and as directed.
M&L for mild steel work in tubular pipe as in post , purlins, trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 all as specified and as directed.
M&L for plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment all as specified and as directed.
M&L for mild steel flat iron for wind ties in roof sheeting including securing bolts, drilling holes all as specified & as directed.
M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 5 to 10mm all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 12mm thick in cement mortar 1: 6 on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on fair faces of concrete surfaces in ceiling, finished even and smooth complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of colour wash over & including a coat of white wash complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement paint white or tinted over & including a coat of cement wash complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
All as per serial item No 34 but on ceiling all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over & including one coat of chalk whiting complete all as specified and as directed.
S&F 8mm thick PVC board, Ist quality, size 600mm x 600mm with and including galvanised iron frame work for seamless ceiling, comprising of galvanised iron perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to center/intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900 mm center to center with and including hanger wire, 4 mm dia, galvanised iron upto 1200 mm length adjustable level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3mm size 60mm long and steel expansion fasteners with and including ceilling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to center frame work for false ceiling including dismantling of existing old false ceiling all as specified and as directed.
S&F 4mm thick asbestos cement plain building boards, fixed to mild steel frame work in false ceiling with clips/screws, preparation of new surfaces of asbestos cement ceiling boards and applying three coats of white wash complete including dismantling old ceiling boards all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and as directed.
M&L for prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick, sheeting of colour as approved by GE, having strength of 550 mpa as in roof covering etc all as specified and as directed.
M&L for 6mm thick asbestos cement , corrugated or semi corrugated sheets in roofs, walls etc, fixed with L or J type or cranked hook bolts complete all as specified and as directed.
All as per serial item No 41 but except sheets all as specified and as directed.
M&L for 6mm thick asbestos cement two piece serrated ridge for corrugated or semi corrugated sheets, fixed with L or J type or cranked hook bolts complete all as specified and as directed.
Dismantling of mangalore pattern or similar tiles including ridge tiles in roofing all as specified and as directed.
M&L for roof tiles mangalore pattern, interlocking at side joint, laid dry all as specified and as directed.
All as per serial item No 45 above but except tiles.
M&L for ridge or hip tiles to suit Mangalore pattern roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 all as specified and as directed.
All as per serial item No 47 above but except ridge or hip tiles.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote all as specified and as directed.
M&L for preparation of surfaces of new or old wooden battens of any size/specings and treated with two coats of creosote oil all as specified and as directed. Note : Measured overall on one side only, spaces shall not be not deducted
M&L for preparation of new steel surfaces of any description over 10 cm with of girth not other wise described and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
Taking down carefully existing bituminous felt including plaster of any thickness and cleaning of the surfaces of roof including flushing and junction parapets kerb walls PCC fillets benching etc with wire brushes and removing of the rubbish to a distance not exc 500mtrs and depositing where directed at alevel not exc 1.5 mtrs above the starting point complete all as specified and as directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaing out and filling solidly with a hot mixture of bitumen and clean dry sand in ratio 1:1 (by weight) all as specified and as directed.
Demolition of cement concrete unreinforced of roofs, floors (other than ground floors), beam, staircases, landing, chajjas and similar suspended work all as specified and as directed.
M&L for 25mm thick (average) PCC, type B-0, 1:2:4 (using 12.5mm graded stone aggregates) mixed with water proofing compound @ 3% by weight of cement or as per manufacturers instructions laid on roof surfaces to maintain slope, finished even and smooth without using extra cement all as specified and as directed. Note : Supply only water proofing compound will be measured and paid saperately.
M&L for preparation of new concrete surfaces and applying one coat of polymeric primer @ 0.30 Kg per Sqm, confoming to IS:3384., APP based polymeric membrane, 3mm thick (min), weight not less than 3.5Kg/Sqm, reinforced with polyster non woven fabric (weighing not less 150gms) and applying two coats of aluminium paint @ 0.11 lit/Sqm all as specified and as directed. Note : Application of polymeric membrane shall be torch application all as per manufacturer instructions
Supply only integral water proofing compound, ISI mark all as specified and as directed.
M & L for preparing surfaces thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles and fill fine crack up to 1 mm with Dr.Fixit roofseal top coat directly by brush or roller after cleaning the cracks stir well prior to application. all joints/corners/drainage outlets and penetration points shall be treated prior to all application of two coat of Dr.Fixit Roofseal Top Coat. all corners, gaps, joints, protrusions and outlets should be coated with an extra coat incorporating reinforcing fabric. Dr.Fixit Roof Seal Coat may be applied by roller,brush. Apply a coat of Dr.Fixit Roof Seal Coat (diluted with water in ratio 2:1) as self priming 9-10 Sq.mtr/Litre. Allow coating to dry for 3-4 hours prior to applying first coat and second coat. Apply two coats of Dr.Fixit Roof Seal Coat @ 2 -2.2 Sq mtr /litre/coat, without water dilution,the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total DFT of 450=500 micron. Allow the system to air cure for 3 days minimum all as specified and as directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position exc 250 ltrs but n.exc 500 ltrs capacity. (Cleaning, repairing etc. measured separately) all as specified and as directed.
Disconnectingt existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position exc 500 ltrs but n.exc1000 ltrs capacity. (Cleaning, repairing etc. measured separately) all as specified and as directed.
Taking up or down steel tubing and connections of 15 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections of 20 mm bore, complete all as specified and as directed.
S&F 15mm bore steel water tubes, medium grade, galvanized with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and as directed.
Refixing old steel tubing 15mm bore, with and including new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
S&F 20mm bore steel water tubes, medium grade, galvanised with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and as directed.
Refixing old 20mm bore steel tubing, galvanised with and including new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, including taking down old rain water pipes complete all as specified and as directed.
S&F in repairs, 110mm bore PVC (SWR) bends any radius complete all as specified and as directed.
M/s S.R lahoti
M/S. M.A. Sharief engineers and contractors
sonu enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .