Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹38.0 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder for the subject work. | |
| 2 | L-2₹38.3 L+₹28,340 (0.75%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | L-3₹39.0 L+₹1.0 L (2.67%)Rejected-Finance | L-3 | Rejected-Finance other than the lowest bidder |
| Sl No | Description | Qty | Unit | POONAM ELECTRIC INDUSTRY L2 | ROYAL CONSTRUCTION L3 | JYOTI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 0.00GENERAL SUMMARY | ||||||
| 1.00Lump sum price worked out by the contractor against Schedule ‘A’ Part- I (BUILDING WORKS) for the following building works:- | ||||||
| 1.01 | (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH/29(R)/2025 Sheet No. 1/2, CWE/ARCH/29(R)/2025 Sheet No. 2/2 and Construction of Store Room with Toilet facility as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications built in permanent specification with RCC frames construction including ATT, WPT mosquito proofing with kota stone flooring, etc complete all as specified and as directed.
NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs before execution of work by the contractor. | 2 | Block | 16,10,000 ₹32,20,000 | 16,45,000 ₹32,90,000 | 16,00,000 ₹32,00,000 Lowest |
| 2.00 | Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 1,03,000 ₹1,03,000 | 1,07,950 ₹1,07,950 | 1,02,000 ₹1,02,000 Lowest |
| 3.00 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 62,000 ₹62,000 | 72,354 ₹72,354 | 61,500 ₹61,500 Lowest |
| 4.00 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-IV (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 11,000 ₹11,000 | 9,750 ₹9,750 Lowest | 10,800 ₹10,800 |
| 5.00 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 53,000 ₹53,000 | 50,000 ₹50,000 Lowest | 52,700 ₹52,700 |
| 6.00 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 16,000 ₹16,000 | 14,560 ₹14,560 Lowest | 15,500 ₹15,500 |
| 7.00 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 1,32,000 ₹1,32,000 | 1,35,000 ₹1,35,000 | 1,31,900 ₹1,31,900 Lowest |
| 8.00 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part- VIII (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 55,500 ₹55,500 | 55,000 ₹55,000 Lowest | 55,000 ₹55,000 Lowest |
Tender Value
₹38.4 L
EMD Value
₹76,700
Closing Date
2 Dec 2025, 6:00 pmClosed
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
PROVN OF STORE ROOM WITH TOILET FACILITY AT MAIN RECEIVING SUB STATION AT BAIRAGARH AND SI LINES UNDER GE BHOPAL
2025_MES_724927_3
84041/E8
Open Tender
Civil Works
Item Rate
365 days
Bhopal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Bhopal
₹76,700
Yes
27 Dec 2025
20 Nov 2025
4 Dec 2025
20 Nov 2025
2 Dec 2025
27 Nov 2025
20 Nov 2025 - 27 Nov 2025
Amount
GENERAL SUMMARY
Lump sum price worked out by the contractor against Schedule ‘A’ Part- I (BUILDING WORKS) for the following building works:-
(a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH/29(R)/2025 Sheet No. 1/2, CWE/ARCH/29(R)/2025 Sheet No. 2/2 and Construction of Store Room with Toilet facility as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications built in permanent specification with RCC frames construction including ATT, WPT mosquito proofing with kota stone flooring, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs before execution of work by the contractor.
Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part- VIII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for PATH WORKS as listed in Schedule ‘A’ Part- IX (Ref prepriced schedule attached seperately)
SCH 'A' Pt - X (MISCELLANEOUS PARTS)
M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates)
All as per Srl item No. 10.01 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed.
All as per Srl item No. 10.01 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
All as per Srl item No. 10.01 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.complete all as specified and directed.
All as per Srl item No. 10.01 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire complete all as specified and directed.
S & F LED lamp 10 Watt B22 CDL complete all as specified and directed.
S&F in replacement building security light fitting complete with 30 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector complete all as specified and directed
Constructions of brick masonry valve pit of size 450mmx450mmx450mm (internal dimensions) one brick thick wall in cement mortar (1:4) on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation, 15mm thick rendering internally, externally up to 15 Cms below GL provision of valve pit cover made out of 3mm thick MS plate welded with 40 x 5mm thick F1 frame all round including provision of hinges, handles, locking arrangement, ISA 40 x 40x 5mm frame, fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC 1:2:4 type B1 (Block size 230 x 200 x 100mm) including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) and necessary earth work in soft/loose soil complete all as specified and directed.
S&Fof 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed
POONAM ELECTRIC INDUSTRY (BID ID -3488006)
ROYAL CONSTRUCTION (BID ID -3493457)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_829530.xls
BOQ • 0.24 MB
84041TenderDocuments.pdf
Tender Documents • 1.55 MB
84041PrepricedSch.pdf
Additional Documents • 0.23 MB
Alldrawings.pdf
Additional Documents • 8.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .