Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC B 108A SECTOR 36 GREATER NOIDA DISTT G B NAGAR UP | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.5 L+₹5,289.02 (0.14%)Accepted-AOC | L2 | Accepted-AOC L2 |
| Sl No | Description | Qty | Unit | M/S VIRAT CONSTRUCTION L1 | M/S SHAILENDRA PANDEY L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. | 89.74 | CUM | 92 ₹8,256.08 Lowest | 92.25 ₹8,278.52 |
| 2.00 | Earth work in filling in plinth by power transport for a lead upto 1 Km. including excavation, loading, unloading, manual compaction and dressing including all lead and lift with all cost of labour and T&P etc. | 29.4 | CUM | 198 ₹5,821.2 Lowest | 198.5 ₹5,835.9 |
| 3.00 | Providing and laying PCC of concrete grade (M-10) 1:3:6 (1 cement :3 Coarse sand: 6 stone grit 20-40 mm nominal size) including supply of all materials, labour, tools and plants etc. required for proper completion of work | 29.69 | CUM | 7,665 ₹2,27,573.85 Lowest | 7,666 ₹2,27,603.54 |
| 4.00 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. | 131.2 | SQM | 279 ₹36,604.8 Lowest | 280 ₹36,736 |
| 5.00 | Providing and laying RCC of concrete grade (M-20) 1:1.5:3 (1 cement :1.5 Coarse sand: 3 stone grit 20 mm gauge nominal size) including supply of all materials, labour, tools and plants etc. required for proper completion of work | 29.29 | CUM | 9,187.5 ₹2,69,101.88 Lowest | 9,188 ₹2,69,116.52 |
| 6.00 | Brick masonry in 1:4 Cement and sand mortar using class 150 bricks complete in all respect including all leads, lifts, all cost of material, labour and T&P etc. required for porper completion of the work. required for porper completion of the work. | 111.28 | CUM | 6,104 ₹6,79,253.12 Lowest | 6,105 ₹6,79,364.4 |
| 7.00 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). | 23.02 | SQM | 290 ₹6,675.8 Lowest | 290 ₹6,675.8 Lowest |
| 8.00 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. | 20.26 | SQM | 91 ₹1,843.66 Lowest | 91.5 ₹1,853.79 |
| 9.00 | Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws.(a) Single leaf | 37.8 | SQM | 1,573 ₹59,459.4 Lowest | 1,574 ₹59,497.2 |
| 10.00Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | |||||
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
12 Jul 2021, 2:00 pmClosed
EE, SNK, AYODHYA
EXECUTIVE ENGINEER, SARYU NAHAR KHAND, AYODHYA
Construction of 2 No Toilet Block Set at Guptar ghat, Ayodhya.
2021_UPIDC_589092_9
03/EE/2021-2
Open Tender
Civil Works
Lump-sum
60 days
AYODHYA
Please refer Tender documents.
2 documents required · 2 mandatory
₹854
₹1.8 L
Yes
25 Oct 2025
6 Jul 2021
12 Jul 2021
6 Jul 2021
12 Jul 2021
6 Jul 2021
Amount
Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.
Earth work in filling in plinth by power transport for a lead upto 1 Km. including excavation, loading, unloading, manual compaction and dressing including all lead and lift with all cost of labour and T&P etc.
Providing and laying PCC of concrete grade (M-10) 1:3:6 (1 cement :3 Coarse sand: 6 stone grit 20-40 mm nominal size) including supply of all materials, labour, tools and plants etc. required for proper completion of work
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm.
Providing and laying RCC of concrete grade (M-20) 1:1.5:3 (1 cement :1.5 Coarse sand: 3 stone grit 20 mm gauge nominal size) including supply of all materials, labour, tools and plants etc. required for proper completion of work
Brick masonry in 1:4 Cement and sand mortar using class 150 bricks complete in all respect including all leads, lifts, all cost of material, labour and T&P etc. required for porper completion of the work. required for porper completion of the work.
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws.(a) Single leaf
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
Hold fast for chaukhats of doors/windows.
Door / windows & Staircase grill.
Z-Section windows
Angle iron door chaukhat 40*40*5
Bending, Binding, Cutting and Placing in position reinforcement including all cost of labour and material T&P etc. required for porper completion of the work.
12 mm thick plaster in 1:4 CM with coarse sand including cost of material, labour and T&P etc. required for porper completion of the work.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
25mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Painting or varnishing work in small areas or new wood work with two coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works)
Painting or varnishing work in small areas or new wood work with two coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (Wooden. works)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm.
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
(a) 250 mm x 10mm
(b) 200 mm x 10mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :(a) 125 mm.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
INTERNAL PUMBING WORK
SANITARY FIXTURES & ACCESSORIES : Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
a-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
b-Same as above but for European type W.C. pan with white plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require
a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap.
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe
a) 32mm dia
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required
a) One urinal basin with 5 litre white P.V.C. automatic flushing cistern
b) Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
c) Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern
Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms
SOIL WASTE & VENT PIPES AND FITTINGS :
Providing & fixing soil, waste and vent pipes.
a) 100mm dia centrifugally cast iron S & S pipe.
b) 75mm dia centrifugally cast iron S & S pipe.
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.
Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.
a) for 100mm dia pipe.
b) for 75mm dia pipe.
Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors.
a) 100mm inlet & 75mm outlet.
Providing & fixing cast iron coller.
a) 100mm dia.
b) 75mm dia.
Providing and fixing plain cast iron S & S sanitary bend.
Providing and fixing centrifugaly cast iron single equal plain junction of required degree.
a) 100x100x100mm
b) 75x75x75mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.
a) 110mm diameter
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
WATER SUPPLY PIPES AND FITTINGS :
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work)
Exposed on wall
a) 25mm dia nominal bore (medium duty)
b) 32mm dia nominal bore (medium duty)
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.
a) 15mm dia nominal bore
b) 20mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.
a) 15mm dia nominal bore.
b) 20mm dia nominal bore.
c) 25mm dia nominal bore.
d) 32mm dia nominal bore.
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.
a) 15mm nominal bore
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931
a) 15mm nominal bore
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931
a) 15mm nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality.
b) 32mm dia nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SCHEDULE OF QUANTITIES FOR INTERNAL SEWERAGE SYSTEM -
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
a) Pipes 80mm to 300mm diameter.
Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
a) 100mm diameter
b) 150mm diameter
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
a) 100mm diameter S.W. Pipe
b) 150mm diameter S.W. Pipe
Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not
less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.
a) 150 x 100 mm. size P type
With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75
(i) For Sewer Line
Extra for depth of man hole size 90x80 cm
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design
With 20x20 mm square bar
EXTERNAL PLUMBING AND SEWERAGE WORK
EXTERNAL SEWERAGE SYSTEM :
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
a) Pipes 80mm to 300mm diameter.
Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
a) 150mm diameter
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
a) 150mm diameter S.W. Pipe
Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
a) Inside size 90x80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.
EXTERNAL WATER SUPPLY SYSTEM
Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work)
a) 40mm nominal bore.
b) 32mm nominal bore.
Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.
a) 40mm nominal bore.
b) 32mm nominal bore.
Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
With F.P.S. bricks
ELECTRICAL WORK
Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire,piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc.complete in all respects.as directed including matching colour wash.
Wiring points for Fan /Fresh air fan (light duty exhaust fan )with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire,piano type switch & ceiling rose on 3mm thick phenolic paminated backalite sheet etc.complete in all respects.as directed including matching colour wash.
Supply and wiring of submain with two number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in 20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 2.5 Sqmm FR PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects.
Supply & fixing LED tube light with batten suitable for upto 1x 22 watt LED tube light fitting including tubes on surface complete in all respect.
a) 1x22 Watt.(CAT -AAA)
Supply & fixing of single wall bracket on matching M.D.F.E.G. board base etc. complete in all required.
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.
Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.
Supply and fixing of switch box made up of 16 SWG (1.5 mm ) thick M.S. sheet of Following size duly painted with red oxide primer and flushed in wall including cutting of brick work fixing it to the level with cement sand mortar,including matching colour wash supply of all material, labour and T & P etc. required for proper completion of the work.asdirected at site by the engineer in charge.
same as in item No. 159 but of size 200x250x65 mm. size
same as in item No. 159 but of size 250x300x65 mm. size
Supply and fixing of 240 volts 'L' series miniature circuit breaker 9 K.A / 10 K.A.in existing MCB, DB complete with connections as required.
5 - 32 amps. (Legrand Lexic)
Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work.
480x480x200 mm. size
Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followed by two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work.
480x480x200 mm. size
Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge.
25 Amp. D Pole MCB (Legrand Lexic)
Supply and fixing of surface/ flush mounting TPN distribution board (Legrand Lexic) without MCB complete in all respect, as directed at site by Engineer Incharge.
8 Way SPN (Legrand Lexic)
Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects.
Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work.
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required.
Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.
6 sqmm 2 core
Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served sheathed, under ground cable including rubber ring etc. complete in all respects, the armouring of the cable shall be properly connected with earth as per direction of Engineer-in-charge.
6 sqmm 2 core
Supply and fixing of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape, and making connections etc. complete in all respects as per directions of the Engineer-in-charge.
Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required
300mm sweep.
Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
SEPTIC TANK AND SOAK PIT WORK
Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches.
From 0.00 mt to 1.50 mt
1.50mt to 3.0 mt
3.0 mt to 4.50 mt
Providing and laying PCC of concrete grade (M-10) 1:3:6 (1 cement :3 Coarse sand: 6 stone grit 20-40 mm nominal size) including supply of all materials, labour, tools and plants etc. required for proper completion of work
Providing and laying RCC of concrete grade (M-20) 1:1.5:3 (1 cement :1.5 Coarse sand: 3 stone grit 20 mm gauge nominal size) including supply of all materials, labour, tools and plants etc. required for proper completion of work
Brick masonry in 1:4 Cement and sand mortar using class 150 bricks complete in all respect including all leads, lifts, all cost of material, labour and T&P etc. required for porper completion of the work. required for porper completion of the work.
Bending, Binding, Cutting and Placing in position reinforcement including all cost of labour and material T&P etc. required for porper completion of the work.
12 mm thick plaster in 1:4 CM with coarse sand including cost of material, labour and T&P etc. required for porper completion of the work.
25 mm thick Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement .
Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar)
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
M/S SHAILENDRA PANDEY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .