Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC M 92 PANCHSHEEL GARDEN NAVEEN SHAHDARA DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | L1 | Accepted-AOC As per NIT |
Tender Value
₹8.0 L
EMD Value
₹16,013
Closing Date
16 Feb 2024, 3:00 pmClosed
Executive Engineer
Office of the Executive Engineer,EE(Elec), WZ
Fabrication, supplying, installation, testing and commissioning of signage made in different colours along with allied accessories in park opp. B-75, Jeewan park and supply of material for day to day maintenance of municipal buildings in ward 105
2024_MCD_185400_1
MCD/TR/9222/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
120 days
Sitapuri
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹16,013
21 Mar 2024
10 Feb 2024
16 Feb 2024
10 Feb 2024
16 Feb 2024
10 Feb 2024
10 Feb 2024 - 16 Feb 2024
Amount
Approved rate
OD18809/2023-2024:Fabrication, supplying, installation, testing and commissioning of openable Signage made of electrocut computerised automated individual letters in hindi & English, total Covering Area and design as per direction of Engineer in charge, Letters to be made from powder coated sheet with 100-150 mm bottom profiles bended along 4-5mm thick sheet of unbreakable Acrylic Sheet to be used in front which will be pinned to the profile. Approved Color, Vinyl (UV) to be used for Colorful look on the front of Acrylic sheet, Letters back should be duly powder coated/painted with Primer & two coats of approved Color Enamel or Duco paint. The signage shall have a system for easy graphic changes and easy access for maintenance. The illumination source shall be of LEDs or approved equivalent modules with individual current regulator/power supply driver module for every signage complete with all internal wiring etc along with connectors for connections to achieve required and uniform illuminations, specifications and design as per the directions of Engineer in charge. LED specification :Lumen output : 2500 lumens/sqmtr (minimum) radiance angle : 120 degree and above Illumination should be uniform and suitable arrangement should be made for installation of the whole structure using Gi pipes, angles etc but excluding foundation work.
OD21283/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD21284/2023-2024:DSR 2022 7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
OD21285/2023-2024:DSR 2022 14.16.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD21286/2023-2024:DSR 2022 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
OD21288/2023-2024:DSR 2022 5.13 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
OD21289/2023-2024:DSR 2022 2.10.3 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
OD21290/2023-2024:DSR 2022 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
DSR Civil
6.1.1:Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
4.4.1:Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Approved Rate
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.1:P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 300x200x105mm (NS) and outer dimension of 333X233X150 mm high dome complete with suitable arrangement for fixing of 4 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
OD21292/2023-2024:Approved Rate. Supply, installation, testing & commissioning of 9W/12W LED bush/ spike light (with mounting pipe) with die cast aluminium housing with toughened glass suitable for ground mounting, enclosed with glass cover in frame, mounting bracket provided for aiming the object, High Ingress protection against dust & moisture, corrosion resistant coated and IP-65/66 protection as req A. LUMEN EFFICACY >90 lm/watt. B. PF > .95 C. RATED VOLTAGE = 220 -240 VAC,50Hz
122.2.139:Supplying and laying of following size of C PVC pipe in along with all accessories like socket, bend, couplers etc. conforming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc. direct in ground ( 50 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 25 mm dia
122.2.156.(a):P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3x 2.5 sq.mm
122.2.132:SITC of 30W LED Flood Light warm white luminaire fitted with lens, made of pressure die cast aluminum housing & toughened glass cover complete with the following (a) Total system wattage =30 watt +/- 5% (b) Luminaire Efficiency>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class-IP-66/IP-65
122.2.133:Providing and Fixing of Flexible LED Strip light fixtures suitable for rated voltage 220 Volt 50 HZ supply, in White/Green/Red/Warm White Color including all accessories like connectors, Endcap, Holding Cap and Connector Pins but excluding integrated LED adaptor etc as required.
122.2.134:providing and Fixing of integrated LED adaptor for flexible LED strip light fixture suitable for rated voltage 220 volts 50 HZ supply etc as required.
122.2.25:Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
OD21298/2023-2024:dsr 2022 1.17.12 Supplying and fixing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 3x2.5 sqmm
122.1.44:Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
122.1.55:Supply of PVC insulated and FR PVC Sheathed multicore copper conductor 1.1KV grade, conforming to grade IS 694 as required . 3*1.5 Sq.mm
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
OD21302/2023-2024:dsr 2022 1718 supply of 40 amps. rating, 2 pole RCCB, 30mA
OD21305/2023-2024:DSR 2022 1110 supply of 32/0.20 mm (1.0 sqmm) twin circular, FRLS PVC sheathed, workshop flexible copper cable
OD21307/2023-2024:DSR 2022 1104 supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD21308/2023-2024:DSR 2022 1103 supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD21309/2023-2024:DSR 2022 1102 supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD21310/2023-2024:DSR 2022 1101 supply 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
OD21313/2023-2024:SITC of single phase monoblock pump set complete with all accessories workable on 240/515 volts, 50 Hz AC supply. (a) 1 HP (0.75 KW) single phase pump set, head from 12-30 metre suction and delivery 25x25 mm.
OD21314/2023-2024:Supply of 12" (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as reqd.
OD21315/2023-2024:Supply of 1200 mm Sweep 50 Watt, Energy saver ISI Marked BEE 5 Star rating AC Ceiling fan suitable for 230 V, 50 Hertz AC Supply without regulator with blades, down rod etc. complete as required.
Bidder Name
GARIMA SALES CORPORATION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .