Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Tender | |
| 2 | L2₹41.7 L+₹1.9 L (4.86%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹42.7 L+₹2.9 L (7.27%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹44.2 L+₹4.4 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹46.8 L+₹7.0 L (17.6%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Dec 2021, 6:00 pmClosed
GARRISON ENGINEER (SOUTH) BANGALORE
GARRISON ENGINEER (SOUTH) BANGALORE NO 1, ULSOOR ROAD BANGALORE-560 042
AS PER BOQ AND TENDER DOCUMENT
2021_MES_486208_1
GS(S)/B/8554/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (SOUTH) BANGALORE
₹90,000
Yes
31 Dec 2021
3 Nov 2021
3 Dec 2021
3 Nov 2021
1 Dec 2021
19 Nov 2021
3 Nov 2021 - 10 Nov 2021
Amount
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for laying of UG cables and LT Panel board foundation etc and getting out in Hard/dense soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable in layers ( 8 cm before laying the cable and 15 cm after laying the cable and punned into 18 cm thickness) in trenches for cable protection complete all as specified and directed. Note : - Punned thickness only will be measured and paid under this item.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire, one twin core cable flat of size 06 Sqmm complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire, one twin core cable flat of size 10 Sqmm complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium sonductor of size 10 Sqmm x 2 core including taking down unserviceable UG cable complete all as specified and directed.
All as per Item No.10 here-in-before but of size 16 Sqmm x 4 Core.
All as per Item No.10 here-in-before but of size 25 Sqmm x 3.5 Core
All as per Item No.10 here-in-before but of size 35 Sqmm x 3.5 Core
All as per Item No.10 here-in-before but of size 50 Sqmm x 3.5 Core
All as per Item No.10 here-in-before but of size 70 Sqmm x 3.5 Core
All as per Item No.10 here-in-before but of size 95 Sqmm x 3.5 Core
All as per Item No.10 here-in-before but of size 120 Sqmm x 3.5 Core
All as per Item No.10 here-in-before but of size 150 Sqmm x 3.5 Core
S&F galvanized Iron light grade pipe of 40mm dia including fittings for cable protection using road crossing etc complete all as specified and directed.
S&F galvanized Iron light grade pipe of 80mm dia including fittings for cable protection using road crossing etc complete all as specified and directed.
S&F LT straight through joint for under ground cable for 3 ½ / 4 Core upto 50 sqmm complete all as specified and directed.
All as per Item No. 21 here-in-before but of size 70 Sqmm x 3.5 Core.
All as per Item No. 21 here-in-before but of size 95 Sqmm x 3.5 Core.
All as per Item No. 21 here-in-before but of size 150 Sqmm x 3.5 Core.
M&L for preparation of surfaces of pole for painting of steel tubular pole, vertical with one coat of aluminium paint incluing painting black and white strip or as ordered by Engineer-in-Charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not exc 30 cm high & letters or figures not exc 10 Nos complete all as directed.
M&L for preparation of surfaces of pole for painting of PCC pole, vertical with one coat of cement base paint incluing painting black and white strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not exc 30 cm high & letters or figures n'exc 10 Nos complete all as directed.
M&L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron strip 25 x 4 mm by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 (with 20mm graded stone aggregate),chamber and 50mm thick precast RCC (1:2:4) cover slab re-inforced with XPM Jalli including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion and taking down old one all as specified and as directed.
S&F GI bracket for street light fittings 32mm dia 1.2Mtr length including D/C clamps for PCC/Steel pole round or square nut bolt and washers etc including painiting of bracket and clamps complete all as specified and directed.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 400 Amps with breaking capacity 36 KA complete all as specified and directed. Make:- Havells Item code No. IHLLNFBT0400 or equivalent in Indoasian/L&T.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 250 Amps with breaking capacity 36 KA complete all as specified and directed. Make:- Havells Item code No. IHLFNT0250 or equivalent in Indoasian/L&T.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 200 Amps with breaking capacity 36 KA complete all as specified and directed. Make:- Havells item code No.IHLFNT0200 or equivalent in Indoasian/L&T.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 160 Amps with breaking capacity 36 KA complete all as specified and directed. Make:- Havells item code No.IHLFNT0160 or equivalent in Indoasian/L&T.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 125 Amps with breaking capacity 16 KA complete all as specified and directed. Make:- Havells item code No.IHLFNT0125 or equivalent in Indoasian/L&T.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 120 Amps with breaking capacity 16 KA complete all as specified and directed. Make:- Havells item code No.IHLFNT0120 or equivalent in Indoasian/L&T.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 100 Amps with breaking capacity 16 KA complete all as specified and directed. Make:- Havells item code No.IHLFNT0100 or equivalent in Indoasian/L&T.
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 63 Amps with breaking capacity 16 KA complete all as specified and directed. Make:- Havells item code No.IHLFNT063 or equivalent in Indoasian/L&T.
M&L for triple pole GOD, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps capacity 11000 volts including taking down old unserviceable one complete all as specified and directed.
M&L for lightning arrester for outdoor type use, non liner resistor type horn gap and chocking coil maximum discharge capacity 65 KA for 11 KV complete all as specified and directed.
S&F MCB TPN 40 Amp capacity three phase 425 volt 50 Hz complete all as specified and directed.
S&F MCB TPN 63 Amp capacity three phase 425 volt 50 Hz complete all as specified and directed.
S&F in repair Voltmeter/ammeter 3 phase 415 v olt 30 Amp to 500 Amps complete all as specified and directed. Make:- Havells item code ISCELMLX0008 or equivalent in Indoasian/L&T.
S&F Neon light set for RYB complete all as specified and directed. Make:- Havells item code No ISCELXLX0003 or equivalent in Indoasian/L&T.
S&F Terminal block of 3 way and 5 way complete all as specified and directed. Make:- Havells item code ICELPSMX002 & ISCELXPX0003 or equivalent in Indoasian/L&T.
S&F in repair power contactor for 3 Phase Motor starter 1.5 ML 20 HP starter complete all as specified and directed. Make:- Havells item code IHPBC020100 or equivalent in Indoasian/L&T.
S&F in repair power contactor for 3 Phase Motor starter 3 ML for 40 HP starter complete all as specified and directed. Make:- Havells item code IHPBC040100 or equivalent in Indoasian/L&T.
S&F Bottle Fuse 32 Amp 11000 Volts for RMU complete all as specified and directed. Make:- Mega win
S&F Thermoplastic IP 66/67, weather proof, corrosion free, halogen and silicon free, UV reistence, insulated and shock proof, High impact strength, flame retardant and self extinguishing, Glow wires test conducted at 960 Deg junction box suitable for terminating cable for 6Sqmm/10 Sqmm/16 Sqmm including necessary cable gland and check nut Size of M32 (incoming and out going cbles) and mounting bracket clamp suitable size as per site with nut bolt washer complete all as specified and directed. (Make- Hensel Cat Part No -KF1010B and Cable Gland Cat Part No 1555.32.25)
S&F PVC Conduit pipe from PVC Junction Box to street light bracket for protection of cable fixing clamp on PCC poles drilled the hole and insert a PVC gitti and screwed suitable size but bolt complete all as specified and directed.
S&F PVC 3 Core copper cable 1.5 Sqmm insulated for fixing of junction box to street light fittings complete all as specified and directed.
S&F outdoor type automatic timer for street light control single phase 230 volt maximum load 12 KW 25 Amp rating with hinged LID complete all as specified and directed. Make:- Havells cat No IHXTS0912A or equivalent in Indoasian/L&T.
S&F outdoor type automatic timer for street light control three phase 230 volt maximum load 6 KW 25 Amp rating with hinged LID complete all as specified and directed. Make:- Havells cat No IHXSS0106A or equivalent in Indoasian/L&T.
Fabricate, Supply, testing, commissioning for Feeder pillar box made of copper bus bar of 400A capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.0mm thick, CRCA sheet, angle iron frame of size 40x40x6mm including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform etc complete all as specified and directed.
Fabricate, Supply, testing, commissioning for Bus bar Chamber box made of aluminium bus bar of 100A capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.0mm thick, CRCA sheet, angle iron frame of size 40x40x6mm including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform etc complete all as specified and directed. Make:- Indo Aisan Item Code CPPI1025 or equivalent in Havells/L&T.
Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
M&L for hardcore (stone) of gauge n exc 63mm deposited,spread and levelled in layersn exc 15cm thick,watered and rammed to a true surface for HT 4/2 pole structure and transformer yard complete all as specified and as directed.
Excavation in post holes (or similar holes) each not exc 0.5 cum and getting out including, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed.
Dismantling of concrete poles of any size and removal from the site complete all as specified and directed.
Supply and errect swaged steel tubular poles, 9 meter long complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and directed.
S&F LED security light fittings aesthetically designed roadway luminaire with excellent thermal management complete 45Watt IP 66 including dismatling old one complete all as specified and directed. Make:- Bajaj cat part No. ENXT P 45L WW CR PC SD or equivalent in Philips/Wipro.
GS TRADERS
Varsha Enterprises
M/S Jaiprakash Electrical and Engineering Works
RRK PROJECTS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .