Er. Gurpreet Singh Bhains
Office of the Executive Engineer, Electrical Division No. 1, Sector-9,Chandigarh.
ANNUAL MAINTENANCE OF 2 NOS. 125 KVA DG SET INSTALLED IN EDC BUILDING, IT PARK, CHANDIGARH) (DURING THE YEAR 2026-2027)
2026_CHD_91714_1
E1/TN-16
Open Tender
Electrical Works
365 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹2,820
28 Apr 2026
13 Apr 2026
20 Apr 2026
13 Apr 2026
20 Apr 2026
13 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Routine servicing & maintenance of AMF panel and 2 No. 125 KVA D.G. Set (Cummins make) installed at EDC building, I.T. Park, Chandigarh. The DG set shall have to be tested twice a month or whenever required by the qualified and experienced staff., (As per Complete Item No. 1 of the DNIT) | 2 | Each.Job. P.Month | - | - | |
Service of 125 KVA D.G. Set of (Cummins make) including changing of following parts. The job includes the cost of the following S/E parts and other, petty material to complete the same like o-rings,(As per Complete Item No. 2 of the DNIT) | - | - | - | - | |
Air filter only servicing and cleaning | 2 | Per.Job | - | - | |
Supply and fixing of engine stop solenoid valve for 125 KVA DG Set of make electronic type by dismantling of the old burnt out solenoid valve fixing of new solenoid valve in the D.G. Set and making all the necessary electrical connections with proper wiring, testing for the same. | 1 | Each | - | - | |
Providing and fixing of under voltage relay of 24 volt capacity. The job includes dismantling of all the cables form the under voltage relay. The job also includes fixing of new under voltage relay and giving all necessary electrical connections to the relay. | 1 | Each | - | - | |
Providing and fixing of battery charger of 24 Volt capacity to Teknika make. The job includes dismantling of all the cables from the battery charger. The job also includes fixing of new battery charger and giving all necessary electrical connections to the relay. | 1 | Each | - | - | |
Servicing and repair of burnt out self starter for 125 KVA DG Set of 24 volt capacity. The job includes dismantling of all the cables from the battery and the self starter dismantling of the self starter from the engine body repairing of the self starter for change of burnt out spares as solenoid armature carbon bushes etc. assembly of the self starter and testing on the test rig. Fixing of the repair self connection to battery and the self with proper thimbles etc. testing the working of the self starter on auto / manual more. | 1 | Each | - | - | |
S/E of Sealed Maintenance Free Battery 150 AH 12V of Exide/ Panasonic / Amaron make only complete in all respects with connecting terminals, leads etc. to the entire satisfaction of Engineer-in-charge. The battery should be guaranteed for a period of three year against the manufacturing defect. | 1 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.80 MB
BOQ_112209.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid