Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.8 LAdmitted-Finance B 1124 SHASTRI NAGAR DELHI 110052 | NORTH | DELHI | 110052 | -55.52% | ₹10.8 L | L1 | Admitted-Finance |
| 2 | L2₹13.3 LAdmitted-Finance | -45.12% | ₹13.3 L | L2 | Admitted-Finance |
| 3 | L3₹18.4 LAdmitted-Finance G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | -24.00% | ₹18.4 L | L3 | Admitted-Finance |
Tender Value
₹24.2 L
EMD Value
₹48,338
Closing Date
20 Feb 2026, 3:00 pmClosed
EE,ELD-7,DDA
EE,ELD-7,DDA
RMO of E.I and fans, air conditioners, 125 KVA DG set and other installations at DDA project office and conference hall at Munim Ji Ka Bagh, Narela and site offices for NPD-2,3 near Pocket 9 and NPD 5,8 at near Pocket 7 at sector A1-A4 Narela.
2026_DDA_898175_1
13/EE(E)/ELD-7/DDA/2025-26
Open Tender
Electrical Works
365 days
NARELA
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹48,338
26 Feb 2026
12 Feb 2026
21 Feb 2026
12 Feb 2026
20 Feb 2026
12 Feb 2026
Running , maintenance and operation of DDA project office at Narela along with 02 nos. site offices in Sector A1-A4 Narela as per inventory and terms and conditions attached.
Comprehensive maintenance of key telephone system installed at DDA office complex munim ji ka bagh Narela. 6x48 Hybride key Telephone Exchange 24 Keys Telephone Anologue Telephone Instruments MDF & DB Box CVT and Battery
Comprehensive maintenance of Conference system installed at DDA office complex munim ji ka bagh Narela Controller Unit Chairman unit Delegate Unit Ampifier Cordless Mike Wall Speeker
Comprehensive maintenance of CCTV (Surveillance) system installed at DDA office complex munim ji ka bagh Narela 32 Ch. NVR 10 TB HDD 5MP Bullet Camera 43" LED Monitor 8 Port Poe Switch UPS Battery
Supply of LED Batten light (System lumen efficacy >135 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22 Watt
Supply of 400mm sweep swinging type wall mounted fan with fastener for mounting ,suitable to run on step rpm including connection, testing, earthing etc complete as required.
Supply of following type ventillation fan ISI mark suitable to operate on 220-230V, 50Hz single phase AC supply including outer frame and fastener etc complete as required.
Double ball bearing type MS exhaust fan 300mm sweep
washroom ventillation fan 200mm sweep (plastic body)
Extension cord (min 4 way and 5mtr long lead)
Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply of following Electrical installation ISI mark suitable to operate on 220-230V, 50Hz single phase AC supply in office complex.
Stepped type Modular Fan regulator (2 module
1.5sq mm wire (FRLS, PVC insulated single core, copper conductor) DSR 2025 item 1101
2.5sq mm wire (FRLS, PVC insulated single core, copper conductor) DSR 2025 item 1102
4.0 sq mm wire (FRLS, PVC insulated single core, copper conductor)DSR 2025 item 1103
Rewinding of upto 1400 mm sweep ceiling fan complete with varnishing, oiling & greasing, quarter pin i/c removing, refixing the same position, connection and testing etc. as required.
Servicing of 125KVA capacity D. G. Set (Kirloskar make) i/c Supply and replacement of kirloskar care coolant, premium genuine oil, battery water, battery terminals, hose pipes, all the filters (fuel filter, lube oil filter, air filter) etc. as required. ( The servicing be done by the authorised service centre / OEM )
Servicing of Air Conditioner of following capacity i/c cleaning with chemical, condenser coil, evaporation coil and washing the complete A.C. with front grill, oiling / greasing the fan motor re-installation in the same position/location, i/c connection, testing etc. complete as required.
window type AC
Split Type AC
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel ,making connections etc as required.
Servicing of desert cooler 18”/20” sweep & dismantling and re-fixing the same position i/c supplying and replacement of wood wool pad with M.S jali & binding wire of suitable size i/c oiling greasing of pump & motor , taping of loose connection& re-installation etc. complete as required
Painting and numbering (1'' width in yellow color having description DDA/Division/Sr No.) of desert cooler 18”/20” sweep with synthetic enamel paint in outside and black rubber paint in inner side i/c removing the existing paint/coloure from the desert cooler from different rooms & placing at the same location after painting etc. as required.
supplying and replacement of following parts of desert cooler i/c connection, testing & commissioning etc. complete as required
Desert cooler body size 18”/20” made out of 18 SWG G.I. sheet complete with side panel, front Grill i/c fixing of cooler pump, fan motor, distributor, connection, testing etc. as required.
Desert cooler side panel 18”/20” made out of 18 SWG G.I. sheet, dismantling of old, refixing of wood wool pad, jali testing etc. as required.
New cooler kit(copper winding) ISI mark (1440rpm speed)
Leg arm set for support, fixing of fan motor
Submersible pump set water lifting 1.5 Mtr. Capacity
cooler tank 26''X26''
Readymade lead 3 core PVC insulated PVC sheathed copper conductor un-armored cable 1.5 Sq. mm size approximate 3 Mtr. long with 3 pin plug top 15/16 amp. ISI marked
MS Blade 18" complete set
Capacitor 4 mfd
Front grill made by M.S. sheet for desert cooler 18”/20” sweep
Rewinding of fan motor Kit 3 speed i/c 4mfd capacitor, ring, nut, bolt etc.
Angle iron stand of suitable size for cooler with two legs grouted in wall
supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
5/6 amp Switch
15/16 amp Switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
SP MCB 'C' curve 6-32 amp
DP MCB 'C' curve 6-32 amp
SITC of Monoblock pump set of 1 HP, 220V,50 Hz Suitable for water lifting for terrace water tank including connection, testing, earthing etc complete as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100 A,30KA,FPMCCB
125 A,36KA,FPMCCB
200 A,36KA,FPMCCB
Lifting of the submersible pump set from the existing borewell along with G.I. Pipe, bend, submersible cable and other accessories i/c dismantling the G.I. Pipe and pump set etc. complete as required.
Lowering of submersible pump set in the existing borewell along with GI pipe, bend, submersible cable wire rope upto required depth i/c making water proof cable joint connection, testing etc. complete as required.
Repairing and Rewinding of submersible Motor suitable for 3 phase 415 volts 50 Hz Ac supply of the following capacity i/c connection, testing etc. complete as required. 5 HP capacity
S/R of D.O.L. starter MK – 1 type suitable for / up to 7.5 HP pump set on the existing panel board / feeder pillar i/c connection, testing etc. complete as required.
S/R of water proof submersible copper conductor Cable of size 1 x 3 x 2.5 sqmm i/c S/F cable clips making connection, cable jointing & testing etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
16 way, Double door
LED Flood Light, powder coated pressure diecast aluminium (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioningof Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supplying of following size of XLPE Al. conductor armored power cable of 1.1 KV grade i/c testing etc. as required.
3x 4 sq. mm
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 150 sq. mm
3 X 25 sq. mm
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.06 MB
BOQ_944072.xls
BOQ • 0.37 MB
NIT13.pdf
Tender Documents • 6.96 MB
Download all tender documents and submit your bid