Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹7.7 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹7.8 Cr+₹7.9 L (1.01%)Rejected-Finance | ₹7.8 Cr+₹7.9 L (1.01%) | L2 | Rejected-Finance being other than L1. |
| 3 | L3₹10.3 Cr+₹2.5 Cr (32.8%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹10.3 Cr+₹2.5 Cr (32.8%) | L3 | Rejected-Finance being other than L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Renewal letter not uploaded by the firm |
Tender Value
₹7.3 Cr
EMD Value
₹6.9 L
Closing Date
16 May 2022, 6:00 pmClosed
Chief Engineer Bareilly Zone
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
PROVISION OF ESSENTIAL DEFICIENT OTM ACCN FOR INF BN No.2 (PHASE-II) AT MEERUT CANTT
2022_MES_517773_1
NIT NO CEBZ / MRT / T-06 OF 2022-23
Open Tender
Civil Works
Lump-sum
547 days
Meerut
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE P No 02 Meerut
₹6.9 L
Yes
15 Jul 2022
12 Apr 2022
21 May 2022
12 Apr 2022
16 May 2022
10 May 2022
12 Apr 2022 - 30 Apr 2022
Amount
SCHEDULE 'A' PART-I (BUILDING WORK)
Total amount of SCHEDULE 'A' PART-I (BUILDING WORK) (For details see Schedule 'A' Part-I in PDF folder)
Total amount of SCHEDULE 'A' PART-II (INTERNAL WATER SUPPLY) (For details see of Schedule 'A' Part-II in PDF folder)
Total amount of SCHEDULE 'A' PART-IIIA (INTERNAL ELECTRIFICATION) (For details see of Schedule 'A' Part-III-A in PDF folder)
SCHEDULE 'A' PART-IIIB (INTERNAL ELECTRIFICATION)
M&L for point wiring (concealed) complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable upto and incl working voltage 1100volts grade, PVC conduit, medium grade,ISI marked with fittings such as bend, tee, junction boxes elbows etc incl pressed steel terminal sunken boxes covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws, cup washers and unsheathed copper conductor cable earth continuity wire connetctd to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area conductor and all other metal parts with earth dolly complete all as specified and directed for the following:-
One Light point controlled by one 5/6 Amp one way switch.
One ceiling fan point controlled by one 5/6 Amp one way switch
One exhaust fan point controlled by one 5/6 Amp one way switch
One 3/5 pin socket outlet, 5 Amp controlled by one 5/6 Amp one way switch on the same board with other switches with cable 1.5 sqmm size.
One 3/5 pin socket outlet, 5 Amp controlled by one 5/6 Amp one way switch on independent board.
One Light point controlled by one 5/6 Amp two way switch.
M&L for point wiring (concealed) complete using 2.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable, upto and incl working voltage 1100volts grade, PVC conduit,medium grade ISI marked with fittings such as bend, tee, junction boxes elbowsetc incl pressed steel terminal sunken boxes covered withcovered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws, cup washers and unsheathed copper conductor cable, earth continuity wire connetctd to DBs/sunken boxes/fittings of size 2.5 Sqmm Cross sectional area conductor and all other metal parts with earth dolly for one three pin 15/16 Amp, socket out let point on independent board complete all as specified and directed. (Note:- Switches/Sockets to be measured and paid separately under respective items)
M&L for sheet metal enclosure single pole and neutral with one 2 pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts, complete all as specified and directed.
Supply and fixing vertical load line type TPN DB, 6 way, as per IS - 8623, IP-43 protection, universal mounting with suitable capacity copper bus bar with neutral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB TPN 125 Amp as incomer and MCB TPN 63/40 Amp as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed.
Supply and fixing vertical load line type TPN DB, 4 way, as per IS - 8623, IP-43 protection, universal mounting with suitable capacity copper bus bar with nuetral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB TPN 63 Amp as incomer and MCB TPN 40/32 Amp as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed.
M&L for SPN DB double door 8 way for mounting MCBs/Isolators/ELCBS etc factory made conforming to IS: 13032 fabricated out CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link 200 Amps rated copper bus bar, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion, double door type with hinged & locking arrangement, flush to wall, IP-42 protection and label marking of incoming and outgoing circuit on all wayscomplete all as specified and directed. (Note:- DBs and MCBs/ISOlators etc shall be of same make)
M&L for SPN DB, double door 6 way for mounting MCBs/Isolators/ELCBS etc factory made conforming to IS: 13032 fabricated out CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link 200 Amps rated copper bus bar, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion, double door type with hinged & locking arrangement, flush to wall, IP-42 protection and label marking of incoming and outgoing circuit on all wayscomplete all as specified and directed. (Note:- DBs and MCBs/ISOlators etc shall be of same make)
M&L for SPN DB, double door 4 way for mounting MCBs/Isolators/ELCBS etc factory made conforming to IS: 13032 fabricated out CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link 200 Amps rated copper bus bar, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion, double door type with hinged & locking arrangement, flush to wall, IP-42 protection and label marking of incoming and outgoing circuit on all wayscomplete all as specified and directed. (Note:- DBs and MCBs/ISOlators etc shall be of same make)
S&F miniature circuit breaker single pole, 240 volts and 6 to 32 Amps current rating , B Series, 10 KA complete all as specifed and directed.
S&F MCB isolator single pole, 240 volts and 40 Amps current rating , B Series, 10 KA complete all as specifed and directed.
S&F MCB isolator single pole, 240 volts and 63 Amps current rating , B Series, 10 KA complete all as specifed and directed.
S&F miniature circuit breaker single pole & neutral, 240 volts and 32 Amps current rating , breaking capacity 10 KA, 'C' series, complete all as specifed and directed.
S&F miniature circuit breaker single pole & neutral, 240 volts and 40 Amps current rating , breaking capacity 10 KA, 'C' series, complete all as specifed and directed.
S&F miniature circuit breaker single pole & neutral, 240 volts and 50 Amps current rating , breaking capacity 10 KA, 'C' series, complete all as specifed and directed.
S&F MCCB 63 Amps, TPN, 4 pole, breaking capacity 16 KA, 415 volts, complete all as specifed and directed.
S&F MCCB 40 Amps, TPN, 4 pole, breaking capacity 16 KA, 415 volts, complete all as specifed and directed.
S&F MCCB 125 Amps, TPN, 4 pole, breaking capacity 16 KA, 415 volts, complete all as specifed and directed.
M&L for sub main wiring with 2 run, single core 6 sqmm, PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/surface conduit,25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 6 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Three run of 6 sqmm copper cable and PVC conduit will be measured as one unit.
M&L for sub main wiring with 2 run, single core 4 sqmm, PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/surface conduit, 25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 4 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Three run of 4 sqmm copper cable and PVC conduit will be measured as one unit.
M&L for sub main wiring with 4 run, single core 10 sqmm, PVC insulated PVC unsheathed stranded copper conductor cable in and including PVC concealed/surface conduit, 25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 10 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Five run of 10 sqmm copper cable and PVC conduit will be measured as one unit.
S&F bulk head LED light fitting 1X9W/10W LED with lamp including LED driver holder and connection wire three core copper conductor etc. complete all as specifed and directed. ( Make- C&S Cat Part No.CHANDRA-9W/W/B22 / Make-Wipro Cat No.9W 6500K N90051 B22 / Make - Havells Cat No.LED ADORE 9W B22 WW)
Supply and fixing surface and wall mounted LED batten light fitting 230 volts, extruded aluminium housing provided for efficeint dissipation with polycarbonate diffuser amd integrated electronic driver with industrial grade heavy duty having THD<10% , ultra glass LED with very high efficeincy suitable for installation in existing T-8 fitting with G13 lamp holder, high lument output, PF>0.98, neutral white 20 watt 4 ft light fitting with lamp etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor 1.5 sqmm cable wire, complete all as specified and directed. Make- Havells Cat Part No. LHEXACP7IN1J020/Make-Crompton Cat Part No. LSTLN-20 CDL/ Make-Wipro, Cat Part No.LL20-221-XXX-65NE3
Supply & fixing aluminium extruded suspended LED light fitting 20 Watt, 230 volt, ceiling hanging with integrated electronic driver with high transcluent frosted diffuser, bipin holders, connecting block etc complete with all accessories internally prewired and including connection up with three core copper conductor 1.5 sqmm wire from ceiling rose to connector of street light complete all as specified and directed. (Make- Havells Cat Part No. CONSTA544LP20WLED840SPCWH/ Make- Wipro Cat Part No.LM31-211-XXX-57WG1 / Make -Bajaj Cat Part No. BPCS20W LED 4FDWH)
Supply & fixing security light fitting, LED type, 36 Watt, pressure die cast aluminium housing, heat resistant toughened glass, IP-66 protection and impact resistance of IK07 with 10 KV built in surge protection device, better optics distribution with integrated electronic driver including connection up with three core copper conductor 1.5 sqmm wire from ceiling rose to connector of street light complete all as specified and directed. (Make : Havells - Cat Part No LTESST36WLED/LS, Crompton Greaves - Cat Ref No ENDURACITY LITEPLATPLUSSL35WLEO757SASYBOPC, Wipro - Cat No LSTS-36-CDL-M, Philips - Cat No LR03-501-XXX-57
S&F GI pipe 'light grade' wall/pole mounting bracket of size 40 mm bore and 1.50 m long fixed to wall with and including nut, bolts and GI clamps of size 50x4 mm as required including two coats of synthetic enameled paint over a coat of primer, complete all as specifed and directed.
S&F blanking plate complete all as specifed and directed.
Supply & fixing ceiling fan energy saving 5 star rated, without regulator 230 volts single phase 1200mm sweep Energy saving fan Including canopy set,down rod and shackle assembly,Fan hook including providing three core copper conductor cable of size 1.5 Sq mm 3 core from fittings to ceiling rose or connector and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Make : Havells Model - Aeroking, Crompton High Speed Ceiling Fan, Orient Model - Energy Star)
S&F Exhaust fan energy saving 3 star rated, 450 mm sweep heavy duty with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Make : Havells - Turbo Force SP, Orient 450mm Heavy Duty Exh (900 RPM) Grey / Crompton Greaves Industrial Fan)
S&F exhaust fan energy saving 3 star rated, 300 mm sweep Metallic body with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Make : Havells - Ventil Air DS / Orient 300mm Air Flow / Crompton Greaves driftair 3 blade exhaust fan)
M&L for earthing completed with galvanized mild steel earth plate (electrode)600 x600x6.00 mm thik burried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcole dust mixed with salt ot a packed thickness of 15 cm all round the plate, using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI "light grade' pipe from upper end of earth plate upto main switch/control of the building including 20 mm dia gi pipe light grade as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber and RCC pit cover with lifting handle, excavation earthwork including laying of GI pipe concealed in floor/ walls all as described in electrical plate No. 5 of SSR Part-I, complete all as specified and directed. (Note:- The quoted rate deemed to be included protection pipe including GI wire 4 mm dia from top of plate upto 7.50 mtr above GL)
SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTH WORK)
Total amount of SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTH WORK) (For details see of Schedule 'A' Part-IV in PDF folder)
Total amount of SCHEDULE 'A' PART-VA (ROAD, HARD-STANDING AND CULVERT) (For details see of Schedule 'A' Part-VA in PDF folder)
SCHEDULE 'A' PART-VB (ROAD, HARD-STANDING AND CULVERT )
Supply and fixing cat eye reflective type of metal body alloy of size 110mm x 128mm x 29.5mm with PAMA striplens reflector of model No. DA 971 fixed with and incl MS stud of suitable size as per manufacturer instructions complete all as specified and directed. (Make:- (a) Future Vista Mumbai (b) Jiya Engineering Company, New Delhi (b) Industrial Hardware Center, New Delhi)
Total amount of SCHEDULE 'A' PART-VI A (SEWAGE DISPOSAL) (For details see of Schedule 'A' Part-VI A in PDF folder)
SCHEDULE 'A' PART-VI B (SEWAGE DISPOSAL )
Construction of Septic tanks for 150 users excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole covers having 6mm plate embeded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified & directed.
Construction of Septic tanks for 50 users excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole covers having 6mm plate embeded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified & directed.
Construction of Soakage well of size 2.40 mtr dia and 6.00 mtr effective depth, excavation in any type soil, foundation in PCC 1:3:6, brick work in walls of Honey combed and solid using sub class 'B' bricks in cement mortar 1:4, including RCC cover slab in M-25 and filling with brick bats, complete all as specified & directed.
Total amount of SCHEDULE 'A' PART-VII (AREA DRAINAGE) (For details see of Schedule 'A' Part-VII in PDF folder)
Total amount of SCHEDULE 'A' PART-VIII A (RAIN WATER HARVESTING) (For details see of Schedule 'A' Part-VIII A in PDF folder)
SCHEDULE 'A' PART-VIII B (RAIN WATER HARVESTING)
Boring holes 250mm dia complete with DTH comrotary method upto 60m depth below ground level in any type of soil incl removal of surplus soil upto 50m distance complete all as specified and directed.
Supply and lowering into bore 150mm dia PVC casing pipe perforated holes complete all as specified & directed.
Total amount of SCHEDULE 'A' PART-IX A (EXTERNAL WATER SUPPLY) (For details see of Schedule 'A' Part-IX A in PDF folder)
SCHEDULE 'A' PART-IX B (EXTERNAL WATER SUPPLY)
M&L for construction of brick masonry pit chamber of following internally size 950mm x 950mm x 900mm with angle iron frame of sizes 20mm x 25mm x 6mm and 4 mm thick mild steel plate cover painted with two coat of synthetic enemelled paint over a coat of red oxide primer after preparation of surface including locking arrangement and necessary excavation and earth work 80mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate over 100 mm thick hard core using broken in foundation brick work in cement mortor (1:6) and 15mm thick cement plaster in cement mortor 1:4 in internal surface of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
M&L for construction of brick masonry pit chamber of following internally size 450mm x 450mm x 450mm with angle iron frame of sizes 20mm x 25mm x 6mm and 4 mm thick mild steel plate cover painted with two coat of synthetic enemelled paint over a coat of red oxide primer after preparation of surface including locking arrangement and necessary excavation and earth work 80mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate over 100 mm thick hard core using broken in foundation brick work in cement mortor (1:6) and 15mm thick cement plaster in cement mortor 1:4 in internal surface of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
Total amount of SCHEDULE 'A' PART-XA (EXTERNAL ELECTRIC SUPPLY) (For details see of Schedule 'A' Part-XA in PDF folder)
SCHEDULE 'A' PART-XB (EXTERNAL ELECTRIC SUPPLY)
M&L 40 mm bore GI pipe light grade bracket bent to shape 1200 mm long fixed with mild steel 32x4 mm flat iron clamps with nut & bolts, washers etc complete all as specified and directed. .
Supply & fixing street light fitting, LED type, 70 Watt, 6000 K, pressure die cast aluminium housing, heat resistant toughened glass, IP-65/66 protection and impact and corresion resistant including thermal management in multiple optics distribution with integrated electronic driver including connecting up with three core copper conductor 1.5 sqmm wire from junction box to connector of street light complete all as specified and directed.
Supply, instalation, testing and commissioning of LT feeder pillar box (KIOSK) type totally enclosed made out of mild steel sheet 3.15mm thick outdoor type weather, dust and vermin proof having sloping canopy with both side openable and angle iron 40mmx40mmx6 mm duly painted with two coat of stove enammel paint over a coat of red oxide with primer, suitable for AC 440 Volt , 3 phase, 4 Wire , 50HZ system having following incoming and outgoing feeder control accessories:- (a) INCOMING: - MCCB 125 Amp 4 pole, 415 Volt with rupturing capacity 35 KA - 01 No. (b) OUTGOING:- (i) MCCB TP 63 Amps, 415 V with rupturing capacity 35 KA - 01 Nos (ii) MCCB TP 80 Amp, 415 V with rupting capacity 25KA- 01 Nos. (iii) MCCB TP 32 Amps, 415 V with rupting capacity 25KA- 01 Nos (vi) MCB SPN 32 Amps, 230 V with rupting capacity 10 KA- 04 Nos (v) MCCB TP 40 Amp, 415 V with rupting capacity 25KA- 01 Nos (Spare) (Description Contd to BOQ next Srl Nos.)
Supply, Installation, commissioning and testing of transformer copper wound step down 100 KVA out door type 11/0.433 KV (at no load) AC 3 phase, 50 HZ, on secondary side double copper wound, oil immersed naturally all air cooled (ONAN type) with external cooling tubes / radiatiors, double copper wound core type having no load voltage ratio 11 KV / 415 volts corresponding to principal tapping, delta connected primary side (HV Side) and star connected on secondary side (LV side) in accordance with vector symbol DYN 11 (Vector group - 4) with neutral brought out on LV side and having tapping on HV side for constant out put so as to altervary secondary voltage from (+) or (-) 2.5 %, (+) or (-) 5% and (+) or (-) 7 .5 % in step to be changed by mean of manual OFF LOAD tap changing arrangements, maximum temperature rise should not exceed 45 degree C in oil and 50 degree C in HV/LV winding when measured by resistance method after continuous full load run in ambient temperature, transformer shall be conforming to IS-1180 Pt-I 2014 complete all as specified. The transformer shall be complete with following fittings and accessories :-
(a) Oil conservator tank with filling hole and cap drain and oil level guage. (b) Silica gel breather with oil seal and first fill of dehydrating agent. © Pressure relief valve with automatic resetting arrangement after release of pressure – 01 Set. (d)Oil temperature gauge having range 0-120 degree C with max reading 100mm dia with shut off valve between the conservator and main tank. (e) Double float Buchholz relay with alarm and trip contacts with one No. of shut off valve. (f) Adequate No. of thermometer pocket including one number for accommodating bulb type thermometer. (g) Oil drain filter valve. (h) 01 nos cable end box on LV secondary side consisting of 04 nos porcelain bushing with bushing rods and nuts/washers and cable glands suitable for reception of out 3.5 core, 95 sqmm LT XLPE cable 1100 volts grade including glands joints complete (j) Oil level gauge (k) Rating plate with terminal plate (l) Cover lifting lugs (m) Jacking and lifting lugs (n) 04 nos plain solid cast iron detachable rollers (o) Extra bushing for neutral outside the cable box and providing independant earthing for neutral (p) First filling transformer oil conforming to IS: 335-1972 and tested upto 60 KV dielectric strength (q) Earthing terminals -02 Nos located on diagonally opposite transformer tank (Note:- Transformer shall be mounted on pole structure and pole structure will be measured separately under respective items)
Supply, Installation, commissioning and testing APFC panel for 3 phase 415 volts, 50 Htz supply system of capacity 50KVAR without incoming MCCBs, complete all as specified and directed.
Material and labour for earthing wth galvanized cast earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 mtr below GL with top edge of earth plate not less than 1.5mtr below GL the earth plate surrounded by adequate quantity of charcoal dust and salt all as around as earth plate 15 cm by and GI strip 32 x 6mm as earth continuity including protection pipe 50 mm bore light grade from chamber to earth plate, CI funnel with wiremess fixed on water pipe and PCC 1:2:4 type B-1 duly reinforced with MS bar in lifting handle excavation earthwork including laying of GI pipe in walls etc all as directed in electirical plate No 3 of SSR Part-I complete all as specified and directed.
Material and labour for earthing wth galvanised cast earth plateof size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25mtr below GL with top edge of earth plate not less than 1.5mtr below GL the earth plate surrounded by adequate quantity of charcoal dust and salt all as around as earth plate 15 cm by and GI earth wire 4mm dia as earth conductor, bolts and rivetted to earth plate one end protection with GI pipe light grade 15mm bore upto 2.4mtr on pole with flat iron clamp nut bolt complete earth work water pipe from earth chamber to earth plate, CI funnel with wiremess fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick precast RCC 1:2:4 type B-1 duly reinforced with MS bar 6mm dia @150cc both ways with 10mm dia MS bar in lifting handle excavation earthwork including laying of GI pipe in walls etc all as directed in electirical plate No 3 of SSR Part-I complete all as specified and directed.
Supply and fix pole mounting type box fabricated of 1.8 mm thick mild steel sheet size not less than 100x200x80 mm, with front openable hinged door, locking arrangement with 3 nos aluminium bus bar 50 Amp rating mounted on porcelain insulator, cable gland, lugs for fixing 01 nos. MCB SP 6 Amps, 10 KA, including mild steel flat iron clamp made out of 40x4 mm FI and nut, bolts & washers duly painted clamps, nuts & bolts with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. (Note:-Rate of MCB shall be included in the quoted unit rate)
T&P and labour for trenchless excavation or boring holes under road/pavement by Trenchless technology using ultra sound technique machine including HDPE 150 mm dia pipe of 0.40 MPa working pressure complete all as specified and directed.
Supply and fix lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XIA (WATER COOLER, REFRIGERATOR, DESERT COOLER) (For details see of Schedule 'A' Part-XI A in PDF folder)
SCHEDULE 'A' PART-XIB (WATER COOLER, REFRIGERATOR, DESERT COOLER)
Supply, installation and testing of drinking water cooler electric driven (Single phase), having storage capacity 80 ltr and cooling capacity 40 ltr per hour made out of partially stainless steel body, complete all as specified and directed.
Supply installation and testing of refrigerator electric driven (Single phase), capacity 190 ltr, direct cool single door refrigerator BEE: 5 star rated IS: 1476 latest for direct cool puff insulation, copper coil, complete all as specified and directed.
Supply and Install desert cooler electric driven single phase having nominal air flow capacity of 4000 Cum per hour (or nearest size) complete with water circulating pump, Air exhaust fan, bottom water tank complete all as specified and directed.
S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 290V with output voltage 230 V with accuracy (+) or (-) 2.5% and of capacity 0.5 KVA time delay 4-6 Sec all as specified and directed.
S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135V to 280V with output voltage 230 V with accuracy (+) or (-) 2.5% and of capacity 1.0 KVA with time delay relay 2-4 sec all as specified and directed.
Total amount of SCHEDULE 'A' PART-XII (SOLAR HOT WATER SUPPLY (For details see of Schedule 'A' Part-XII in PDF folder)
BLANK
M/S. JAI PRAKASH GUPTA
Shree Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .