Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO 438 10TH EAST CROSS STREET ARINGAR ANNA NAGAR MADURAI MADURAI TAMIL NADU 625020 | MADURAI | TAMIL NADU | 625020 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 91 92 KODAMBAKKAM HIGH ROAD NUNGAMBAKKAM CHENNAI TAMIL NADU 600034 | CHENNAI | TAMIL NADU | 600034 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
3 Aug 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
THE DIRECTOR JIPMER
THE DIRECTOR JIPMER PUDUCHERRY
RATE CONTRACT for supply of CONSUMABLES and NON CONSUMABLES for the Department of Medical Gastroenterology for 2021 22.
2021_JIPMP_636519_1
JIP/PUR6(1)/OeT/MGE/2021-22
Open Tender
Consumables (Hospital / Lab)
Supply
365 days
JIPMER PUDUCHERRY
Please refer Tender documents.
10 documents required · 10 mandatory
₹590
Payable To THE DIRECTOR JIPMER
Exempted
9 Jul 2022
1 Jul 2021
4 Aug 2021
1 Jul 2021
3 Aug 2021
13 Jul 2021
1 Jul 2021 - 7 Jul 2021
365 days
CONSUMABLE
Single use biopsy Forceps (UGI) • Should have oval fenestrated cup to enable large biopsy fragments • Should have ribbed sheath to aid insertion & channel protection • Should have Unique SwingJaw mechanism to aid tangential biopsies • Suitable for 2.8 mm channel • Working length 1650 mm
Single use biopsy Forceps (COLON) • Should have oval fenestrated cup to enable large biopsy fragments • Should have ribbed sheath to aid insertion & channel protection • Should have Unique SwingJaw mechanism to aid tangential biopsies • Suitable for 2.8 mm channel • Working length 2300 mm
Single use biopsy Forceps (SMALL BOWEL) • Should have oval fenestrated cup to enable large biopsy fragments • Should have ribbed sheath to aid insertion & channel protection • Should have Unique SwingJaw mechanism to aid tangential biopsies • Suitable for 2.8 mm channel • Working length 2700 mm or more
Sclerotherapy Injection Needle 21 G Specifications 1. Needle with catheter, presterilized and disposable 2. Should have a stiff sheath for prevention of kinking and enhanced penetration into target. 3. Should have an ergonomic handle with positive click action. 4. Length of the needle should be 4 mm 5. Working length: 1650 mm compatible with 2.8 mm working channel
Sclerotherapy Injection Needle 23 G Specifications 1. Needle with catheter, presterilized and disposable 2. Should have a stiff sheath for prevention of kinking and enhanced penetration into target. 3. Should have an ergonomic handle with positive click action. 4. Length of the needle should be 4 mm 5. Working length: 2700 mm compatible with 2.8 mm working channel
Sclerotherapy Needles for Colonoscopy/UGI use Specifications 1. It should have star shaped inner catheter design to enable needle actuation in tortuous anatomy and ensuring minimum friction 2. Needle Gauge should be 25 G with maximum needle extension of 4 mm. 4. Outer sheath diameter: 2.3 mm 5. Working length: 200 cm
Sclerotherapy Needles for Colonoscopy/UGI use Specifications 1. It should have star shaped inner catheter design to enable needle actuation in tortuous anatomy and ensuring minimum friction 2. Needle Gauge should be 25 G with maximum needle extension of 4 mm. 4. Outer sheath diameter: 1.8 mm 5. Working length: 240 cm
Esophageal Varices Ligator band Specifications 1. Should contain a barrel with 6 bands 2. Bands should be totally latex free or made of natural rubber latex for prevention of allergy 3. Bands should be prepared through machine moulding to reduce the risk of post banding rebleed. 4. Should have a clear band to signal when only one band remains to be deployed
Esophageal Varices Ligator (With Handle) Specifications Multiband ligator set for endoscopic variceal ligation, set should include 1. Barrel with 6 bands 2. Bands should be totally latex free or made of natural rubber latex for prevention of allergy and should be prepared through machine moulding. 3. Should have a clear band to signal when only one band remains to be deployed 4. Trigger cord and loading catheter should be provided. 5. Precision control handle and irrigation adapter compatible for use with 2.8 mm accessory channel 5. Rotation of 90 degree of the handle should result in deployment of the band
Glue for gastric variceal hemostasis Specifications 1. Should contain N butyl Cyanoacrylate glue. 2. Should contain 1 ml per ampoule.
Polidoconol Injection Specifications: a. 2 ml vial conatining 3% polidoconol for endoscopic sclerotherapy of esophageal varices.
Endoscopic bipolar electrohemostasis catheter Specifications: 1. Should have a rounded gold distal tip 2. Catheter shaft should be 7 Fr, firm to reduce kinking and allow en face as well as tangential tamponade. 3. Probe should be combined with 25 G sclerotherapy needle 4. Should have an integrated channel for manual or mechanical irrigation 5. Working length should be 210 cm 6. Compatible with minimum working channel of 2.8 mm
Endoscopic bipolar electrohemostasis catheter Specifications: 1. Should have a rounded gold distal tip 2. Catheter shaft should be 7 Fr, firm to reduce kinking and allow en face as well as tangential tamponade. 3. Should have an integrated channel for manual or mechanical irrigation 5. Working length should be 300 cm 6. Compatible with minimum working channel of 2.8 mm
Endoscopic Bipolar Coagulation Forceps Specifications: a. Should have less impact of deeper tissue thermal degeneration b. Enables long-term prevention of re-bleeding c. Based on its flexibility, it can be used for different applications such as EMR/ESD, gastrointestinal bleeding and papilla resection d. Should have minimum length of 2200 mm and capable of using in 2.8 mm working channel
Endoscopic Electrosurgical haemostasis forceps: Specifications 1. Should have a precise rotatable design for precise appraoch & targeting 2. The forceps cup should have a anti slip construction to grasp bleeding point securely for faster and reliable hemostasis a. Upper GI [Tapered tip for precise approach] 1. Working length: 1650 mm Cup size: 5 mm b. Lower GI [smaller distal cup to suit colon's thin wal] 1. Working length: 2300 mm Cup size: 4 mm
Endoscopic Hemostatic clips Specifications: 1. Should have a 360° bidirectional rotation for precise clip placement. 2. Should have a reopening capability up to multiple times. 3. Catheter size: 7 Fr, Length: 230 cm 4. Should have a distinct anchoring tips and Nitinol reinforced jaws. 5. Widest span: 16 mm.
Individual single use clips Specifications: 1. Standard clip arm length with 135-degree exterior jaws angle 2. Should be sterilized, disposable and come in a cartridge for loading. 3. Should be compatible for loading on to a rotatable reusable applicator
Hemospray for non-variceal bleed management 1. Should contain a natural mineral powder 2. Should contain a preassembled device handle containing the CO2 cartridge. 3. Should have a knob for activation and deactivation of the CO2 cartridge. 4. Should contain a valve which when opened makes it ready for deployment of hemostatic powder. 5. Should have a trigger which upon depressed for 1-2 seconds deploys the powder. A - 7 Fr *230cm catheter B - 10 Fr *230cm catheter
Metallic guide wire for use in endoscopic dilation Specifications 1. Guidewire should be made of stainless steel 2. Should have coiled spring distal tip with the tip shape progressively flexible. 3. Wire guide length should be 200 cm or more with markings on the guidewire to assess the depth of insertion.
Controlled radial expansion balloon for endoscopic dilation a. 6-8 mm b. 8-10 mm c. 10-12 mm d. 12-15 mm e. 15-18 mm Specifications 1. Multi diameter balloon - three distinct sizes at three distinct pressure 2. Balloon made of Pebax, a non compliant material 3. Should have a rectilinear shoulders of balloon for endoscopic visualization and evaluation during procedure 4. Balloon length of 5.5 cm, 240 cm long catheter compatible with 2.8 mm working channel.
Percutaneous endoscopic gastrostomy set with feeding tubes sizes, a. 20 Fr. b. 24 Fr. Specifications 1. Percutaneous endoscopic gastrostomy set for pull technique 2. Should contain Pivotal bolster, insertion wire, cold snare, universal adapter, safety sharps and miscellaneous accessories for peg tube placement.
PEG replacement Tubes Specifications 1. Feeding tube size 18 Fr. & 24 Fr. 2. Length 24.6 cm 3. Balloon capacity 20 cc
Foreign body retrieval basket 1. Should have a hard wire basket for removal of foreign bodies 2. Should have a rotatable pin vise 360 degree 3. Should have a shape memory 4. Sheath size should be 7 Fr and working length 200cm 5. Should have a dual lumen A. Size 2x4 cm B. Size 3x6 cm
Foreign body retrieval forceps Specifications 1. Jaw opening diameter should be more than 7 mm 2. Sheath diameter should be 2.3 mm and working length of 230 cm 3. The forceps should have an alligator jaw with a rat tooth design for good grasping of foreign bodies in the gut.
Foreign body/ Polyp retrieval net Specifications: a. Should be flexible and a durable basket b. Should have a octagon design to enable spring like action c. Designed to open maximum capacity and have memory points to maintaining its shape even after several passes d. Should be made of transparent netting material to improve visibility e. Net size: A - 4x5.5 cm & 230 cms B - 2.5x4.5 cm & 230 cms C - 2x4.5 cm & 230 cms
Foreign body retrieval prongs Specifications 1. SHould be 360 degrees rotatable 2. Should have an opening diameter of 35 mm 3. Sheath diameter should be 2.3 mm and working sheath length of 230 cm.
Rubber tipped grasping forceps for sharp foreign bodies: Specifications 1. Should have a working length of 190 cm and an opening width of 4.8 mm 2. Must be compatible with channel size - 2 mm 3. Should be reusable and autoclavable 4. The rubber at the tip should be latex free and must grasp sharp objects for easy removal.
Overtubes for extraction of upper gastrointestinal foreign bodies Specifications 1. Compatible with scope diameter 9.8 to 11.7 mm 2. Tapered inner tube 3. Reinforced outer tube with detachable insufflations cap 4. Gastric length of 50 cm.
Overtubes for extraction of upper gastrointestinal foreign bodies Specifications 1. Compatible with scope diameter 8.6 to 10 mm 2. Tapered inner tube 3. Reinforced outer tube with detachable insufflations cap 4. Gastric length of 50 cm.
Inflation syringe for endoscopic controlled radial expansion balloon dilators Specifications 1. Should possess a syringe with the pressure gauge for use with endoscopic balloon dilators 2. Should be compatible for attachment with the inflation handle.
Inflation handle for endoscopic controlled radial expansion balloon dilators Specifications 1. Should possess a handle with a provision for attaching the inflation syringe with the pressure gauge. 2. Should contain a knob which can be adjusted forwards and backwards for activation of the inflation syringe.
Single use Distal attachment Cap Specifications 1. Should be compatible with olympus endoscopes, colonoscopes & enteroscopes 2. Should maintain the appropriate distance between endoscope Tip and Target lesion 3. The edge of distal attachment should have a round shape to reduce damage to tissue. 4. Should have a 3 mm side hole on the sleeve that ensures any fluid on the inside to be drained easily. 5. Distal end from scope after attachment should be 4mm A. Outer diameter of the cap: compatible for use with olympus GF - H170 gastroscopes B. Outer diameter of the cap: compatible for use with olympus GF - H170 colonoscopes C. Outer diameter of the cap: compatible for use with olympus GF - H170 enterscopes
Reusable black cap for Distal attachment to endoscope Specifications 1. Should be compatible with olympus magnification endoscopes with near focus 2. Should be autoclavable 3.Should be black in colour to prevet halation. 4. Should have an outer diameter of 11.45 mm for enabling good fit to the tip of the magnification endoscopes. 5. Should maintain the appropriate distance between endoscope Tip and Target lesion during electronic chromoendoscopy 6. The edge of distal attachment should have a round shape to reduce damage to tissue. 7. Should have a side hole on the sleeve that ensures any fluid on the inside to be drained easily.
Reusable spray catheter for chromoendoscopy Specifications 1. Should have a screw type catheter with a stylet. 2. Should be sterile and autoclavable 3.Should be kink resistant for smooth insertion. 4. Should have a sprinkler mechanism for wider and evenly distributed spraying for clear visualization. A - Working length of 1650 mm compatible with 2.8 mm channel B- Working length of 2400 mm compatible with 2.8 mm channel
Detachable snare Specifications 1. Opening width: 30 mm 2. Sterile and disposable 3. Should have Loop materials with firm grip 4. Compatible with applicator in item 36
Detachable snare applicator 1. Sterile and disposable. 2.Working length 2300 mm 3. Working channel: 2.8 mm 4. Ligation pressure adjustable by controlling handle. 5. Compatible for snares in item 35
Polypectomy snare for use in enteroscopy Specifications 1. Should have wide opening oval Snare 2. Should have thick braided wires for maximum coagulation and control 3. Should possess an integrated handle with measurement marking 4. Wire Thickness should be 0.47 mm and loop diameter should be 25 mm 5. Should be suitable for 2.8 mm channel 6. Working length should be 3000 mm and reusable
Polypectomy snare Specifications 1. Should have wide opening oval snare 2. Should have thick braided wires for maximum coagulation and control 3. Should possess an integrated handle with measurement marking 4. Wire Thickness should be 0.47 mm and loop diameter should be 25 mm 5. Should be suitable for 2.8 mm channel 6. Working length should be 2300 mm and intended for single use
Polypectomy Snare a. Loop width: 27 mm b. Loop width: 30 mm Specifications 1. Should possess a short throw three ring handle 2. Sheath diameter should be 2.4 mm 3. Working length should be 240 cm 4. Should have a flexible braided wire loop 5. The inner diameter of the sheath should have lubricant coated to minimize friction during extension and retraction of the snare.
Rotatable polypectomy snare Specifications 1. Loop width 20 mm 2. Working length 195 Cm 3. Mid catheter rotation activator - Gives snare loop rotation for proper positioning 4. It should have star shaped inner catheter design for reduced friction 5. Should possess the torque technology which provides smooth, predictable rotation even when scope is in torque position
Nasojejunal Tube Specifications 1. Should be radio-opaque, tissue compatible, and made of polyurethane 2. Should be 14 Fr and 120 cm long 3. Should have a hollow flexible guidewire and nasal fixation tape
Over the scope clip system: Specifications: a. Must contain an applicator cap with a mounted clip, a thread and handwheel for clip release b. Caps should be available in different sizes (11, 12 & 14 mm) & different depths (3 or 6 mm) for capturing different amount of tissue. c. The clips should be available in different sizes adapted to cap size & different shapes of teeth for different indications like compression effect, anchring and closure of gastric lumen. d. Should provide two instruments for grasping or anchoring and help in approximation of indurated tissue 1. 8.5 - 11 mm cap, 6 mm depth and teeth with small spikes 2. 10.5 - 12 mm cap, 6 mm depth and teeth with small spikes 3. 11.5 - 14 mm cap, 6 mm depth and teeth with small spikes
Over the scope clip aids: Specifications: a. Must contain an anchor for better approximation of tissue especially when indurated especially for thin tissue. b. Should be applicable in fistulae and chronic ulcers. c. Should provide approximation of gaping edges of the lesion. A - Tissue anchor; B - Tissue grasper
Polyethylene Glycol for bowel preparation for colonoscopy Specifications Each pckt weighs 137.15 g 1. Potassium chloride 2. Sodium bicarbonate 3. Polyethylene glycol (118 g) 4. Sodium chloride 5. Sodium sulphate
Single use splinting tube for use in single balloon enteroscope • Should be made up of latex-free hydrophilic coated silicone • Should have radiopaque materials in the distal end of the splinting tube’s tip for effective positioning confirmation under fluoroscopy •. Must be Sterile and Disposable • Outer Diameter : 13.2 mm. Inner Diameter : 11.0 mm •. Working Length : 1320mm • Comatible for use along with enteroendoscope and balloon control unit.
ERCP Sphincterotome for use with enteroscope Specifications 1. Should have taper tip with the catheter size of 6-5 Fr 2. Length of the catheter should be 320 cm 3. Should allow 0.035"guidewire and compatible with 2.8 mm channel 4. Cutting wire should be 25 mm in length with proximal insulated tip for protection
Triple lumen Needle knife Specifications 1. 5 Fr, 320 cm length catheter 2. 3-5 mm cutting needle compatible with 0.035 inch guidewire 3. Needle control lock in handle
Endoscopic Biliary Dilatation Balloon for enteroscope assisted ERCP Specifications 1. Should be a Hydrophillic dilatation balloon 2. Catheter size should be 6.8 - 4.5 Fr. 3. Legnth of the balloon catheter should be 320 cm 4. Should allow 0.035"guidewire and compatible with 2.8 mm channel A. 6 mm diameter balloon B. 8 mm diameter balloon C. 10 mm diameter balloon
Stone extraction Balloon for enteroscope assisted ERCP 1. 3 inflation diameters in one device to meet specific clinical needs 2. Ease of injection with contrast exiting the distal tip 3. Radiopaque bands enhance fluoroscopic visualization of the extraction balloon 4. Reference marks on syringe indicate each inflation diameter 5. SIZES: a. 8.5//12/15 6. Length of the catheter should be 275 cm or more
ERCP high performance guide wire for enteroscope assisted ERCP Specifications: 1. Should have a 25 cm hydrophilic end 2. Radio-opaque coil spring for fluoroscopic visibility 3. Nitinol core for kink resistance and shape retention 4. Length of the wire should be 600 cm 5. Should be 0.035" and compatible with 2.8 mm channel
ERCP cannula for enteroscope assisted ERCP Specifications 1. Should have a pre curved type tapered tip catheter of size 5.5 - 4.5 Fr 2. Should have a double lumen and a length of 320 cm 3. Should allow 0.035"guidewire and compatible with 2.8 mm channel 4. Should have radiopaque distal tip markings
Biliary Dilation catheter, bougie type for enteroscope assisted ERCP Specifications 1. The length of the catheter should be 275 cm or more. 2. 7 Fr catheter with radiopaque tapered tip to 4 Fr 3. Length of tapering part should be 3 cm 4. Should allow 0.035"guidewire and compatible with 2.8 mm channel
One action Stent introduction system for enteroscope assisted ERCP Specifications 1. Should have a 10 Fr pushing catheter 2. Should have a 6 Fr guiding catheter 3. Should contain four radiopaque bands 5 cm apart 4. Length of the system should be 320 cm 5. Should allow 0.035"guidewire and compatible with 2.8 mm channel
Sclerotherapy Needles for enteroscopy use Specifications 1. Should be compatible with 2.8 mm channel 2. Catheter size should be 7 Fr. 3. Catheter length should be 320 cm. 4. Maximum needle extension possible should be 4 mm A - 23 G B - 25 G
Small bowel capsule Specifications: 1. Should have dimensions of 10 x 25 mm and frame rate of more than 5 fps 2. Operating time of 10 hours or more. 3. Field of view should be more than 155 degrees. 4. Transmission mode should be radiofrequency & image sensor should be preferably complementary metal oxide silicon. 5. Recorder should have real time viewing option. 6. Should be FDA approved. 7. Should provide the sensor pads belt, recorder and software workstation for analysis and interpretation of images.
ERCP cannula a. 5-4-3 1. Distal tip should be 5 Fr 2. Should have an OD of 1.7 mm compatible with 0.018 inch guidewire b.Tapered tip 1. Distal tip should be 5.5 to 4.5 Fr 2. Catheter length should be 200 cm and compatible with 0.035 guidewire 3. Should possess two lumen 4. Should have radiopaque distal tip markings
Dedicated sphincterotome for minor papilla cannulation Specifications 1. Should be a 6 Fr Sphincterotome tapered to 3 Fr at the tip of length 6 mm 2. Should have a braided cutting wire of length 15 mm 3. Should contain over the guidewire injection port 4. Should be compatible with 0.025"guidewire
Triple lumen sphincterotome Specifications 1. Sphincterotome should contain a precurved ditsal tip for easier positioning of cutting wire. 2. Distal tip length should be 3 mm and tapered to 4.5 Fr 3. Cutting wire should be 20 mm in length 4. Should contain separate lumens for guide wire, cutting wire and contrast injection 5. Unique safety coating at proximal half of cutting wire and endoscopic markers assist with positioning the cutting wire 6. Should contain a friction handle to ensure maintaining the bowed position and stable cutting wire orientation 7. Should contain radiopaque tip markings for optimal visibility under fluoroscopy 8. Should contain working length of 170 cms and compatable with 0.035 inch guidewire
ERCP hydrophilic guidewire Specifications a. Angled tip (0.025") b. Straight tip (0.025") 1. Should have a 7 cm highly flexible hydrophilic tip for excellent passability 2. Should contain special fluorine coatings for effortless manipulation 3. Should possess a wider core design of the wire giving enhanced one-to-one torqueability 4. Exceptional endoscopic and fluoroscopic visibility 5. Should have provision for measurement over the wire 6. Should contain working length of 450 cm
ERCP standard straight guidewire Specifications 1. Should have a hydrophilic tip of 5 cm. 2. Shaft should be made of nitinol to prevent kinking and enable good wire manipulation and control. 2. Should have a coating to promote smooth tracking and tactile sensation of the wire during exchange 4. Should contain working length of 450 cm A. .035 inch and B. 0.025 inch
Biliary cytology brush Specifications 1. Working length should be 1900 mm 2. Should have a brush diameter of 3 mm 3. Brush length should be 10 mm or more 4. Should have a distal wire guided design 5. Should have a locking cap on the control section to allow the brush to be locked.
Biliary plastic stents (Straight) 1. 5 Fr (a-5cm, b-7cm, c-9cm, d-12 cm) 2. 7 Fr (a-5cm, b-7cm, c-10cm, d-12cm, e-15 cm) 3. 8.5 Fr (a-10cm, b-12cm, c-14 cm) 4. 10 Fr (a-7cm, b-10cm, c-12cm, d-14 cm) Specifications 1. Minimizes migration with proximal and distal flaps. 2. Smooth cannulation facilitated by tapered tip. 3. Adapts to bile duct due to gentle curved shape. 4. Pushability and softness delivered by polyethylene material.
Biliary plastic stents (Double pig tail) 1. 5 Fr (a-5 cm, b-7 cm) 2. 7 Fr (a-5 cm, b-7 cm, c-10 cm, d-12 cm) 3.10 Fr (a-5 cm, b-7 cm, c-10 cm, d-12 cm) Specifications 1. Minimizes migration with double pigtail configuration 2. Smooth cannulation facilitated by tapered tip 3. Pushability and softness delivered by polyethylene material
Biliary Stone Extraction Balloon a. 9-12 mm b. 12-15 mm Specifications 1. “Squared shoulder” balloon is designed to facilitate stone removal. 2. Triple-lumen Retrieval Balloon 3. Catheter enables front or back loading of guidewire and offers injection-above or injection-below options to support physician preference and facilitate procedural needs.
Endoscopic Stone Retrieval Basket a.2 cm b.3 cm Specifications 1. Can be used for performing mechanical lithotripsy using a lithotripter - Gun 2. Silver tip technology to avoid basket impaction 3. Wire guided, Pre cursor Alloy material
One action Stent introduction system Specifications 1. Should have a 10 Fr pushing catheter 2. Should have a 6 Fr. guiding catheter which should be tapered enabling dilation of the stricture prior to stent placement. 3. Four radiopaque bands 5 cm apart
Stent pushing Catheter a.8.5 Fr b.7 Fr d.5 Fr Specifications 170 cm pushing catheter Compatible with 0.035 inch guidewire
Mechanical Lithotriptor for biliary stones Specifications 1. Two strong wire dormia baskets with sheath with open basket diameter of 3 cm. 2. Rotatable basket available in new bullet tip style. 3. Inner and outer sheath can be preassembled to maximize safety and aid cannulation 4. Working length 1950 mm 5. Should be compatible for use with 4.2 mm working channel
Endoscopic Biliary Dilatation Balloon a. 4 mm diameter b. 6 mm diameter c. 8 mm diameter d. 10 mm diameter Specifications 1. Should have a hydrophillic dilatation balloon 2. The tip should be 4Fr and the length of balloon should be 4 cm 3. Should have a facility for rapid exchange system with two radioopaque positioning markers
Biliary Dilation catheter, bougie type a. 6 Fr b. 7 Fr c. 8.5 Fr d. 10 Fr Specifications 1. 200 cm catheter 2. 6 Fr radiopaque tapered tip and 3. Length of tapering part should be 3 cm
Cystotome for Endoscopic Cystogastrostomy Specifications 1. Should have a 10 Fr outer catheter & 5 Fr inner catheter 2. Should contain a proximal & distal electrode 3. 10 Fr diathermic ring size & 0.038" needle knife
Cystotome for Endoscopic Cystogastrostomy or EUS guided biliary drainage Specifications 1. Should have a 6 Fr catheter with a diathermic tip 2. Should have a length of 180 cm and allow passage of 0.035" guidewire 3. Should contain one HF connector
EUS Fine Needle Biopsy a. 19 G b. 22 G Specifications: 1. Should be made up of Nitinol to retain its shape without any deformation even after multiple passes. This helps ensure the needle follows a predictable and consistent trajectory. 2. Coil sheath with multi layered construction to facilitates excellent force transmission from the handle to the needle tip and Deep tissue can be punctured regardless of scope angle. 3. Echogenic needle tip for enhanced visibility for Controlled Puncture 4. Side hole option to collect the sample within the needle. 5. Sharp Neede Tip: Menghini-type tip with sharp edges supports smooth puncture even at an oblique angle. 6. Adjustable sheath length- Improved Handle Maneuverability for Convenient and controlled handling
EUS Fine Needle Biopsy a. 19 G Specifications: 1. Should be made up of Nitinol to retain its shape without any deformation even after multiple passes. This helps ensure the needle follows a predictable and consistent trajectory. 2. Coil sheath with multi layered construction to facilitates excellent force transmission from the handle to the needle tip and Deep tissue can be punctured regardless of scope angle. 3. Echogenic needle tip for enhanced visibility for Controlled Puncture 4. Sharp Neede Tip: Menghini-type tip with sharp edges supports smooth puncture even at an oblique angle. 5. Adjustable sheath length- Improved Handle Maneuverability for Convenient and controlled handling
EUS Fine Needle Biopsy a. 25 G Specifications: 1. Should possess core trap to receive tissue into the needle. 2. Should have a reverse bevel for shearing material from lesion during retrograde needle movement. 3. High definition needle for ultrasound visibility. 4. Should contain safety lock ring, integrated sheath adjuster 5. Sheath size 4.8 - 5.2 Fr & needle extension: 0-8 cm 6. Metal Luer lock for secure anchoring to the echoendoscope
EUS Fine Needle Biopsy : Needle size: 20 G Specifications: 1. Should possess core trap to receive tissue into the needle. 2. Should have a forward bevel for shearing material from lesion during needle movement. 3. High definition needle for ultrasound visibility. 4. Should contain safety lock ring, integrated sheath adjuster 5. Should have a coiled sheath size 4.8 - 5.2 Fr & needle extension: 0-8 cm 6. Metal Luer lock for secure anchoring to the echoendoscope 7. Needle shouls be made up of stainless steel with a menghini tip
EUS Fine Needle for cytology Specifications: Needle size: 22 G 1. Should possess bevel tip to receive tissue into the needle. 2. Stylet should be 2 mm ball type. 3. High definition needle for ultrasound visibility with a flexible coiled sheath 4. Should contain safety lock ring, integrated sheath adjuster 5. Sheath size 4.8 - 5.2 Fr & needle extension: 0-8 cm 6. Metal Luer lock for secure anchoring to the echoendoscope. 7. Needle should be made of stainless steel.
EUS Needle for EUS guided drainage procedures: Needle size: 19 G Specifications: 1. Should possess bevel stylet tip to easy punch needle. 2. Atraumatic tip designed to allow 0.35 wire giude 3. High definition needle for ultrasound visibility with coiled sheath 4. Should contain safety lock ring, integrated sheath adjuster 5. Sheath size 4.8 - 5.2 Fr & needle extension: 0-8 cm 6. Metal Luer lock for secure anchoring to the echoendoscope
EUS flexible FNB needle a. 22 G b. 25 G Specifications: 1. Should have three pronged tip to provide stability at puncture and have fully formed heels designed to maximize tissue capture and minimize fragmentation 2.Cobalt chromium needle assembly 3. Should have superior needle penetration, pushability, durability and kink resistant. 4. The three points provide stability at puncture while the high quality, fully formed heels are designed to maximize tissue capture and minimize fragmentation
Lumen apposing metal stent for pseudocyst drainage Specifications 1. Should be made of Nitinol 2. Should have flexible and fine mesh tubular prosthesis 3. Should have radiopaque markers, three at both ends and two in the middle. 4. Upon deployment the body of the stent should impart an outward radial force while both heads impart a horizontal inward force, allowing transmural drainage. 5. Should be fully silicone covered facilitating removal. 6. Should have a retrieval String for repositioning or easy removal A - 12 mm B - 16 mm diameter
Lumen apposing SEMS Specifications: a. Should have an electrocautery enhanced Stent delivery system, one step diathermic ring & cut wire for easy access into target tissue b. Lumen apposing SEMS & perpendicular flanges for securing tissue layers and prevent migration c. Saddle length: 8 mm & 10 mm d. Stent diamter A - 8 mm, B - 10 mm C - 15 mm, D - 20 mm e. Compatible with 3.7 mm or more working channel of EUS scope
Sterile water for irrigation of manometry catheter Specifications: 1. Should be apyrogenic 2. Should be compatible for irrigation of water perfused channels of the manometry system 3. Should be available as 3 L containers
Probes for pH and Impedance System Specifications: a. Single channel pH probe. 1. Should be compatible with the Zephyr pH & impedance recorder
Probes for pH and Impedance System Specifications: a. 6 channel impedance & 2 channel pH probe 1. Should be compatible with the Zephyr pH & impedance recorder
Buffer solutions for PH and Impedance testing. Specifications: 1. Should contain buffer solution with pH of 4 + 0.05 which is stable at 25 degree C 2. Should contain 250 ml of the solution per bottle for calibration and be compatible with the Zephyr pH & impedance recorder
Buffer solutions for PH and Impedance testing. Specifications: 1. Should contain buffer solution with pH of 7 + 0.05 which is stable at 25 degree C 2. Should contain 250 ml of the solution per bottle for calibration and be compatible with the Zephyr pH & impedance recorder
Argon plasma coagulation (APC) probe: Specifications: 1. Should be a flexible probe . 2. Should have an integrated membrabe filter and connecting cable so that it will be able to Plug and Play 3. Should be compatible with the existing APC generator and electrosurgical unit of the department. No preparation of the probe or cable should be required 1.Axial openings for the axial plasma beam Dimensions: 2.3 mm Length: 2.2 m 2.Lateral openings for the side fire conical plasma beam Dimensions: 2.3 mm Length: 2.2 m 3. Circular openings for the circumferential plasma beam Dimensions: 2.3 mm Length: 2.2 m 4. Axial openings for the axial plasma beam Dimensions: 1.5 mm Length: 3 m 5. Axial openings for the axial plasma beam Dimensions: 3.2 mm Length: 2.2 m
Neutral electrode safety system foot plate for electrocautery Specifications 1. Disposable foot plate 2. Contact area 168 cm2 3. 3 m connecting cord 4. Compatible with ERBE VIO system
Endoscopic Bite block Specifications 1. Large lateral openings to enhance digital guidance when advancing the endoscope and provides easy access for additional suctioning 2. Should be compatible with 54 Fr mechanical dilator 3. Soft, adjustable, latex-free strap enhances patient comfort 4. Must be self retaining using a strap
Endoscope tip protector: Specifications: 1. Made of Foam 2. Inner diameter: 7-18 mm 3. Outer diamter: 4 cm 4. Length: 14 cm
Disposable biopsy valves Specifications: 1. Cover the openings to the biopsy channels. 2. Maintains scope pressure while passing devices. 3. Latex free. 4. Compatible with olympus endoscopes.
Single use instrument channel adaptor for use with water irrigation pump Specifications: 1. Should contain an adaptor for dual function of water irrigation and passage of an accessory through the instrument working channel. 2. Should be compatible with instrument channel water tube and the working channel of olympus endoscope.
Single use instrument channel water tube for use with water irrigation pump Specifications: 1. Should contain a water tube for attachment to the instrument channel adaptor. 2. Should be compatible for use with olympus endoscope and water irrigation pump.
Auxillary water tube for use with water irrigation pump Specifications: 1. Should contain a reusable water tube for attachment to the auxillary water irrigation channel of olympus endoscopes. 2. Should be compatible for use with olympus water irrigation pump.
Single use endoscopy channel cleaning brushes Specifications: 1. Should contain two channel cleaning brush on either end of a single sheath. 2. Sheath should be flexible and kink resistant and enable brushing through the channel with minimum effort. 3. Bristles should contain optimum thickness and stiffness to ensure full contact with the working channel during cleaning. 4. Should be compatible with olympus endoscopes with working channel of diameter 2 - 4 .2 mm. 5. Working length should be 220 cm or more
Single use endoscopy channel opening cleaning brushes Specifications: 1. Should contain channel opening cleaning brush. 2. Sheath should be flexible and kink resistant. 3. Bristles should contain optimum thickness and stiffness during cleaning. 4. Should be compatible with olympus endoscopes with working channel of diameter 1.2 - 6 mm.
Disposable Endoscopy Cleaning brushes 1. Able to clean accessory channels and endoscope valves, valve housings and connectors. 2. Rigid yet flexible channel brush shaft to allow for ease of passage. 3. Covered brush tip to protect endoscope channel. 4. Ergonomically designed double ended valve cleaning brush to maximise cleaning. 5. Brush size – 6.5-5 mm 6. Valve brush size - 10, 6-4.5mm 7. Brush length - 240 cm
Xenon lamp for light source of video endoscope processor Specifications: A. 100 W - 1. Should have 400 hours of life 2. Compatible with light source of Pentax endoscope processor.
Xenon lamp for light source of video endoscope processor Specifications: A. 300 W xenon arc lamp - 1 no 1. Should have 500 hours of life 2. Compatible with light source of Pentax endoscope processor.
C-arm cover Specifications: a. Disposable sterile cover for fluoroscopy image intensifier. b. Should be available in different sizes to fit the image intensifier. c. Should have an elastic band for easy retention.
Gastrolaryngeal tube: 1. Should have a Bite block with an endoscopy lumen compatible with duodenoscopes 13.8 mm outer diameter. 2. Should contain a proximal cuff for stabilizing the tube and blocks oro and nasopharynx and distal cuff that blocks esophageal inlet and avoids gastric ventilation. 3. Inflation line for inflation and deflation of cuffs. 4. Ventilation lumen with 15 mm connector. 5. Ventilation holes should lie in front of the larynx
Balloon tube tamponade for variceal bleed Specifications: a. Should have a separate oesophageal & gastric balloon b. Must have a port for continuous suction of gastric contents, separate ports for inflating gastric & oesophageal balloon c. SIzes: A - 14 Fr; B - 16 Fr; C - 18 Fr
Rapid urease test kit for Helicobater pylori detection in endoscopic biopsies Specifications: a. Easy to read colour change for test positivity with superior accuracy b.Results are read within 15 mins. c. Should not require refrigeration d. Should have a long shelf life of atleast 2 years.
Glucose test strips for blood sugar estimation – SPECIFICATIONS: 1. Compatible glucometer should be supplied free of cost to all wards, services & OT where it is required. 2. Free repair/replacement should be provided during the period of use.
Sealing Machine
Partially Covered Oesophageal Metal Stent a. 10 cm b. 12 cm c. 15 cm Specifications 1. Fluoroless Stent Placement using the positioning ruler on the shaft of the delivery system. 2. Single-strand Nitinol wire is designed to maintain luminal patency whilst reducing the risk of migration. 3. Proximal and Distal release deployment with different Flair and Body sizes of Stent
Fully Covered Removable Oesophageal Metal Stent a. 10 cm b. 12 cm c. 15 cm Specifications 1. 18.5 French coaxial style delivery system with 28 mm Flare and 23 mm Body and Reconstrainability upto 75% 2. Excellent fluoroscopic visibility with 4 RO markers with yellow transition zone and proximal reposition marker on handle. 3. Should have permalume silicone covering for preventing tumour ingrowth
Partially Covered Oesophageal Metal Stent with anti-reflux valve a. 8 cm b. 10 cm c. 12 cm Specifications 1. Fluoroless Stent Placement using the positioning ruler on the shaft of the delivery system. 2. Single-strand Nitinol wire is designed to maintain luminal patency whilst reducing the risk of migration. 3. Proximal and Distal release deployment with different Flair and Body sizes of Stent
Through The Scope Duodenal Highly flexible Metal Stent – a. 6 cm b. 9 cm c. 12 cm Specifications 1. Nitinol Treatment offers Complete mesh visibility under fluoroscopy and Superior radial force 2. Recapturing of the stent and repositioning is possible up to 70% stent deployment 3. Should have looped ends to minimise risk of trauma 4. Large diameter stent and flare design: 27 mm flare and 22 mm body for improved relief of obstruction and reduce the risk of migration. 5. Customised Stent for enteral use & flare design proximal to food flow
Through The Scope Colonic Highly flexible Metal Stent – a. 6 cm b. 9 cm c. 12 cm Specifications 1. Nitinol Treatment offers Complete mesh visibility under fluoroscopy and Superior radial force 2. Recapturing of the stent and repositioning is possible up to 70% stent deployment 3. Should have looped ends to minimise risk of trauma 4. Large diameter stent and flare design: 30 mm flare and 25 mm body for improved relief of obstruction and reduce the risk of migration. 5. Customised Stent for Colon & flare design proximal to food flow
Uncovered Biliary Metal Stent – a. 6 cm b. 8 cm c. 10 cm Specifications 1. Should have fixed core, Nitinol wire design for exceptional trackability 2. 8 Fr (2.67mm) low-profile catheter to deploys 30Fr (10mm) lumen stent 3. Should have an elongated, tapered tip to ease passage through difficult strictures 4. Should have an outward radial pressure to gently maintain luminal patency and reduce the need for repeat stenting procedures
Fully covered Removable Biliary Metal Stent a. 6 cm b. 8 cm Specifications 1. Should have platinol wire construction for greater flexibility aid placement in tortuous anatomy. 2. Should have removability indication up to 12 months after placement in benign biliary structure 3. Should possess permalume covering 4. Reconstrainable up to 80% of deployment to aid in repositioning.
Uncovered Biliary Metal Stent – a. 6 cm b. 8 cm Specifications 1. Fixed core, Nitinol wire designed for exceptional trackability 2. 6 Fr low-profile catheter deploys 30 Fr lumen stent 3. Elongated, tapered tip has been shown to ease passage through difficult strictures 4. Outward radial pressure has been shown to gently maintain luminal patency and may reduce the need for repeat stenting procedures 5. Should enable easier deployment of side by side stent at the same time in hilar obstruction
Uncovered Biliary stent Specifications: a. Fixed core, Nitinol wire designed for exceptional trackability b. Laser cut SEMS with a tapered 6 Fr tip stent c. Elongated, tapered tip has been shown to ease passage through difficult strictures d. Outward radial pressure has been shown to gently maintain luminal patency and may reduce the need for repeat stenting procedures e. Should enable easier deployment of side by side stent at the same time in hilar obstruction f. Dual deployment mechanism: Thumb wheel & pull grip g. Stent length should be 10 cm
Self expandable removable metallic stent for variceal bleeding: Specifications: a. Must be made of nitinol and durable silicone covering. b. Should have a design to prevent stent migration c. Should have preloaded delivery system 20 - 28 Fr in diameter & 60 cm in length d. Atraumatic stent ends & radio opaque markers at both ends as well as in the middle of stent. e. Should have retrievable loops made of medical grade alloy at both ends facilitating easy stent removal f. Diameter of the stent should be 25 mm in the body and 30 mm at flare with a length of 135 mm
www.bensonmedicaldevices
Lub Dub Medical Technologies Pvt Ltd
Cook India Medical Devices Private Limited
Innovative Therapeutics (P) Ltd
Bailey and Love
Le Imex Traders
A4 BIOTECH
Texas Medical Systems
KALKI MEDICAL ENTERPRISES
Chennai Medicco Surgicals
MEDIWYN LIFE SCIENCES
Endocare India Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .