Loading…
Loading…
Tender Value
₹2.4 Cr
EMD Value
₹4.8 L
Closing Date
28 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
GENERAL
15 conditions · 3 needing a document upload
For works costing more than Rs.50 Lakhs:The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; where V = Advertised value of the tender in crores of Rupees. N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB in GCC APRIL 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Non submission of the above, the offer will be summarily rejected. (Ref : Advance Correction Slip No.1 dt:14/07/2022 to IRSGCC- 2022 ).
Option for Payment: An option is available that the Supplier/Contractor to take payment from Railways through Letter of Credit (LC) arrangement, having the estimated value of Rs.10 Lakhs and above. All the suppliers/contractors are requested to make use of this facility from Railways.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
"Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HASSDAC) or Automatic signalling"
17 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit Earnest Money Deposit (EMD) & Tender Document Cost (TDC), in respect of e- tendering, should be accepted through net banking or payment gateway only. Fixed Deposit Receipt (FDR) will not be accepted as EMD for tenders invited on IREPS (e-tender portal). When submitted in physical form, the Tenderer shall upload scanned copies of financial instruments such as EMD, Tender form cost, mandatory credentials such as experience, turn over certificates and any other documents as applicable. All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded at the time of submission of bid S&T/SA failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We have read the various conditions to tender attached hereto and agree to abide by the said conditions
I/We also agree to keep this tender open for acceptance for a period of 45 days from the date fixed for opening the same
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
I/We have read the various conditions attached/ referred to in this tender document, and agree to abide by the said conditions.
Deployment Of Qualified Engineers At Work Sites By The Contractor. The contractor shall also employ Qualified Graduate Engineer or Qualified Diploma Holder Engineer, based on value of contract, as may be prescribed by the Ministry of Railways through separate instructions from time to time.(As per RB ltr no.2012/CE-I/CT/O/20 dt:10.05.2013)
One qualified Graduate Engineer when the cost of the work is Rs. 200 lakhs and above.
One qualified Diploma holder Engineer when the cost of the work 9.1.1 to be executed is more than Rs.25 lakhs but less than Rs.200 lakhs.
In case the contractor fails to employ the technical staff as aforesaid, he shall be liable to pay a an amount of Rs.40,000/ (Rupees Forty thousand) for each month or part thereof for the 9.1.2 default incase of Graduate Engineer and Rs.25,000/- (Rupees Twenty five thousand) for each month or part thereof for the default in case of Diploma holder (Engineer)
In case of more than one L-1 bidders, tender may be awarded to tenderer having higher Bid Capacity. In case Bid Capacity is also the same, tenderer having done more value of similar work in last three previous financial years and the current financial year upto the date of opening of the tender, may be selected for the award. Instructions with respect to Bid Capacity will follow.
All the contracts on works/goods/services will be subject to the new GST act as applicable from time to time. Contractors have to register themselves with GST authorities and to furnish the GST registration number in order to process the bills from 01.7.2017
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I/WE also hereby agree to abide by the INDIAN RAILWAY GENERAL CONDITIONS OF CONTRACT- APRIL 2022, with all correction slips up to date and to carry out the works accordingly.
In the e-tendering process, it is mandatory that every tenderer/contractor/firm registered with WWW.IREPS.GOV.IN to submit your bank details i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number
Salem Division: Augmentation of Goods Shed Lines (Rd.6 & 7) with CC unloading pavement at PLMD station and provision of Track Machine Siding at 7 stations (SLY, EL, PRV, PAS, SA, KPPR & UKL)
SA-SG-120-I-OT-02-2026
SA-SG-120-I-OT-02-2026
Open
Works - General
12 Months
Salem, Tamil Nadu
₹0
₹4.8 L
28 May 2026
6 May 2026
14 May 2026
147 items across 2 schedules · ₹2,06,85,118.99 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | " Te s t i n g a n d commissioning t h e RRI/PI s i g n a l l i n g installations j o i n t l y w i t h the Railway representative at site at the stations/ LC gates covered under various schedules of the Contract and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers w ith g o o d quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room k e y entries, block instrument k e y , earth r e s i s t a n c e e t c . , and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)." a)Testing and commissioning of stations (upto 5 roads) | Station 3.00 | — | 38,884.69 | 1,16,654.07 |
| 2 | " Te s t i n g a n d commissioning t h e RRI/PI s i g n a l l i n g installations j o i n t l y w i t h the Railway representative at site at the stations/ LC gates covered under various schedules of the Contract and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers w ith g o o d quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room k e y entries, block instrument k e y , earth r e s i s t a n c e e t c . , and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)."Testing and commissioning of stations (more than 5 roads) | Station 3.00 | — | 67,941.71 | 2,03,825.13 |
| 3 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As- made circuit diagrams also as mentioned above" | Sheet 470.00 | — | 382.12 | 1,79,596.4 |
| 4 | "Supply a n d Provision o f 6 4 I n p u t Digital S t a c k C a r d (Digital I n p u t C a r d ) t o suit Datalogger a s p e r I R S S-99/2006 amt 3 or latest" | Numbers 8.00 | — | 26,458.78 | 2,11,670.24 |
| 5 | S u p p l y a n d Provision o f External Mother B o a r d t o s u i t Datalogger a s p e r I R S S- 99/2006 amt 3 or latest | Numbers 1.00 | — | 73,529.86 | 73,529.86 |
| 6 | Supply and Provision of 128 input tag block f o r termination o f r e l a y w i r i n g inside Datalogger | Numbers 4.00 | — | 7,349.87 | 29,399.48 |
| 7 | Supply and Provision of Euro Rack for housing additional cards and Mother Boards of Datalogger | Numbers 1.00 | — | 17,247.76 | 17,247.76 |
| 8 | Wiring o f Relay Inputs t o Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit 450.00 | — | 285.86 | 1,28,637 |
| 9 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wa g o s required is included as per schedule | Numbers 70.00 | — | 285.86 | 20,010.2 |
| 10 | Supply and Provision of Earthing as per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) | Numbers 2.00 | — | 28,118.51 | 56,237.02 |
| 11 | Supply of earth electrodes (GI) as per Drg no SG/CN/02/13 | Numbers 15.00 | — | 1,618.75 | 24,281.25 |
| 12 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 85.00 | — | 1,707.55 | 1,45,141.75 |
| 13 | "Full Location: Supply and fixing of GI Flat of s i z e 1050x25x3mm a s g i v e n i n enclosed drawing to connect all cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat a n d o n e s p r i n g w a s h e r o f 2 3 s e t . B ) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location 10.00 Box | — | 1,370.66 | 13,706.6 |
| 14 | "Half Location: Supply and fixing of GI Flat of s i z e 550x25x3mm a s g i v e n i n enclosed drawing to connect all cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat a n d o n e s p r i n g w a s h e r o f 2 3 s e t . B ) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location 6.00 Box | — | 846.75 | 5,080.5 |
| 15 | Supply o f L o w maintenance secondary cells o f t h e following capacities w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply o f Secondary cells - 2V- 80AH capacity | Numbers 45.00 | — | 3,379.2 | 1,52,064 |
| 16 | Supply of track feed battery charger IRS:S 89-2013 | Numbers 31.00 | — | 4,375.25 | 1,35,632.75 |
| 17 | Supply of 'B type choke IRS:S 65-83 | Numbers 62.00 | — | 2,855.6 | 1,77,047.2 |
| 18 | S u p p l y o f M o d u l a r Te r m i n a l B l o c k of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s p e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. | Numbers 200.00 | — | 194.95 | 38,990 |
| 19 | "Supply o f F U S E terminals block w i t h LED indication upto 2.5sq.mm screw type 1 IN 1 OUT ( Suitable 400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A, & 10A) (Without Fuse) as per RDSO Spec.No.RDSO/SPN/189/2004/ r e v 2 or latest." | Numbers 50.00 | — | 219.87 | 10,993.5 |
| 20 | Supply of DIN channel for the terminal | Metre 25.00 | — | 344.87 | 8,621.75 |
| 21 | Supply o f E N D plates f o r modular terminal block | Numbers 10.00 | — | 36.86 | 368.6 |
| 22 | Supply o f E N D clamp f o r modular terminal block | Numbers 10.00 | — | 26.35 | 263.5 |
| 23 | Supply o f Shorting L i n k insulated G r e y in color | Numbers 10.00 | — | 21.2 | 212 |
| 24 | Supply of FUSE links of (400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A) | Numbers 50.00 | — | 61.74 | 3,087 |
| 25 | Fixing o f Modular terminal block/fuse block a l o n g w i t h accessories w i t h provision of fixing holes o n hylam sheet/side angles of Location Box a n d fixing b y Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal | Numbers 250.00 | — | 28.97 | 7,242.5 |
| 26 | Supply a n d provision o f normal joint using Thermo shrink jointing k i t (RDSO specs No TC/77/2012 ( Rev.3) with amendment No.1&2 o r latest.& jointing k i t t o be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing t h e same after completion o f cable joint a s p e r the instruction of Railway representative at site. | Numbers 36.00 | — | 4,628.91 | 1,66,640.76 |
| 27 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions o f Railway representative at site.) as per drawing enclosed | Numbers 300.00 | — | 262.65 | 78,795 |
| 28 | Preparation of Cement concrete for covering o f G I Pipes/cables. Providing & L a y i n g in p o s i t i o n c e m e n t c o n c r e t e o f specified p r o p o r t i o n i n c l u d i n g c o s t o f cement, c e n t e r i n g a n d s h u t t e r i n g w i t h 1:3:6 composition 1 Cement: 3 S a n d : 6 grade s t o n e a g g r e g a t e 2 5 m m n o m i n a l size) (Cement, M-Sand, stone jelly of 25mm and all other misc materials required for the work should be supplied by Contractor). | cum 10.00 | — | 9,361.46 | 93,614.6 |
| 29 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying o f cables i s n o t included i n this schedule) | Metre 9000.00 | — | 64.1 | 5,76,900 |
| 30 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule.) | Metre 1500.00 | — | 32.05 | 48,075 |
| 31 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying o f cables i s n o t included i n this schedule.) | Metre 500.00 | — | 79.51 | 39,755 |
| 32 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth o f 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives a t site. (Laying of cables is not included in this schedule). | Metre 100.00 | — | 314.41 | 31,441 |
| 33 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation o f trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. T h e depth o f 1 m trench shall be from the bottom of sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre 480.00 | — | 385.45 | 1,85,016 |
| 34 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench b y r a m m i n g a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f D W C / R C C p i p e s with couplers/collars is not included in this schedule). | Metre 30.00 | — | 501.03 | 15,030.9 |
| 35 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre 420.00 | — | 208.54 | 87,586.8 |
| 36 | Provision o f G I p i p e s (50/100mm d i a ) for cable laying in hard rocky area with off sets a t b o t h e n d s d u l y supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor]. | Metre 660.00 | — | 182.87 | 1,20,694.2 |
| 37 | L a y i n g o f signaling/power/ telecommunication cables a s per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables is not included in this schedule). | Metre 25000.00 | — | 18.18 | 4,54,500 |
| 38 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cable s, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre 9000.00 | — | 15.4 | 1,38,600 |
| 39 | "Refilling of cable trench 0.5m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling." | Metre 1500.00 | — | 7.77 | 11,655 |
| 40 | "Refilling of cable trench 1m depth by 0.5m width throughout, with earth after laying of cable s, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre 500.00 | — | 19.29 | 9,645 |
| 41 | "Digging of pit to a depth of 800mm of size 3 0 0 m m X 3 0 0 m m , c a s t i n g o f concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y ramming. T h e cable markers shall be provided at an interval of 20 M t r s . w i t h i n statio n l i m i t s a n d 5 0 Mtrs. outside station limits throughout t h e cable route, diversions and also at every track/road crossing." | Numbers 300.00 | — | 123.35 | 37,005 |
| 42 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n r e a r o f relay rooms/ A F TC huts, apparatus c a s e s e t c . T h e w o r k includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks o f size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum 5.00 | — | 949.05 | 4,745.25 |
| 43 | " R o a d crossing/ Tr a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc . (Note: T h e pilot used for HDD should be of sufficient size to s u i t insertion o f H D P E / D W C p i p e o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a H D P E p i p e o r a n y other combination as directed by the site engineer) ( Supply of HDPE pipe i s not covered in this schedule)" | Metre 60.00 | — | 1,351.45 | 81,087 |
| 44 | Supply of Main LED Signal Aspect - Green as p e r R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers 2.00 | — | 10,030 | 20,060 |
| 45 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers 8.00 | — | 8,850 | 70,800 |
| 46 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers 8.00 | — | 9,233.5 | 73,868 |
| 47 | Supply o f subsidiary Signal Aspect - Route L E D a s p e r R D S O Specifications S P E C I F I C AT I O N N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers 30.00 | — | 5,703.33 | 1,71,099.9 |
| 48 | Supply o f subsidiary Signal Aspect - Shunt L E D a s p e r R D S O Specification S P E C I F I C AT I O N N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers 25.00 | — | 5,740.7 | 1,43,517.5 |
| 49 | M a n u f a c t u r e a n d s u p p l y o f Enameled Number plates as per drawing No.TY/08/2008 with fixing arrangements and fixing them on the existing Signals as per the instructions of Railway representative at site.[Enameled number plates with fixing arrangements with b o l t s a n d n u t s s h a l l be supplied by the Contractor]. | Numbers 15.00 | — | 305.25 | 4,578.75 |
| 50 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as p e r s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of colour l i g h t S i g n a l p o l e 4 . 6 m tall and 140 mm dia(Galvanised) | Numbers 8.00 | — | 5,841 | 46,728 |
| 51 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as p e r s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) | Numbers 17.00 | — | 4,737.7 | 80,540.9 |
| 52 | Supply of surface base to suit CLS Signal pole 140mm dia with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 25.00 | — | 6,814.5 | 1,70,362.5 |
| 53 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s p e r specification/ drawing/ description e n c l o s e d i n this document. a)Supply o f ladder with platform (4.6m) for CLS(Galvanised) | Numbers 8.00 | — | 5,698 | 45,584 |
| 54 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s p e r specification/ drawing/ description e n c l o s e d i n this document. b)Supply o f ladder with platform (3.6m) for CLS(Galvanised) | Numbers 17.00 | — | 5,494.5 | 93,406.5 |
| 55 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as p e r s p e c i fi c a t i o n / d r a w i n g / description enclosed in this document. | Numbers 19.00 | — | 5,087.5 | 96,662.5 |
| 56 | S u p p l y o f G r o u n d t y p e s h u n t s i g n a l - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers 15.00 | — | 7,463.5 | 1,11,952.5 |
| 57 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) | Numbers 8.00 | — | 16,874 | 1,34,992 |
| 58 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers 17.00 | — | 14,278 | 2,42,726 |
| 59 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way | Numbers 2.00 | — | 22,260.7 | 44,521.4 |
| 60 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. d)Supply of Junction type route indicator - 4 way | Numbers 1.00 | — | 25,960 | 25,960 |
| 61 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. e) Supply of Junction type route indicator - 5 way | Numbers 1.00 | — | 29,529.5 | 29,529.5 |
| 62 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers 2.00 | — | 3,569.5 | 7,139 |
| 63 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers 2.00 | — | 2,645.5 | 5,291 |
| 64 | Supply o f cable termination b o x (FRP type) w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. | Numbers 28.00 | — | 7,788 | 2,18,064 |
| 65 | Supply of Signal post telephone with facility o f p a g i n g a n d talk-back including voice communication e q u i p m e n t w i t h suitable switching arrangement at the Signal post and at SM's room as per specification enclosed in t h i s document. T h i s includes drawl o f tail cable through GI pipe 25mm dia and 2 mtrs long duly clamped to Signal post with bend a s required a t site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. The wiring shall b e done using wire PVC 16/0.2mm copper. [Talk-back equipment c o m p l e t e including housing box , w ire P V C 16/0.20mm a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 1.00 | — | 11,897.35 | 11,897.35 |
| 66 | Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC non AC immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 or latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. | Numbers 16.00 | — | 10,722.72 | 1,71,563.52 |
| 67 | Supply of lamp proving relays(QECX-61) for a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers 30.00 | — | 5,901.5 | 1,77,045 |
| 68 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set 10.00 | — | 4,945.51 | 49,455.1 |
| 69 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring o f Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set 21.00 | — | 8,786.26 | 1,84,511.46 |
| 70 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set 16.00 | — | 11,355.02 | 1,81,680.32 |
| 71 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 1 6 / 0 . 2 m m c o p p e r , P h y n o l i c synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1 9 9 5 - Ty p e F 5 , f o r fi x i n g resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring o f Signal/ Point/ L C control circuit (up to 20 relays/Plug in type) | Set 19.00 | — | 13,597.41 | 2,58,350.79 |
| 72 | Supply o f Electric k e y transmitter - rotary type o f required ward Nos. with keys, with necessary inspection a s p e r specification/ drawing/ | Numbers 2.00 | — | 6,344.8 | 12,689.6 |
| 73 | Supply of relay rack to hold 168 relays, with necessary inspection, a s per specification/drawing | Numbers 2.00 | — | 40,700 | 81,400 |
| 74 | Fabrication and Supply of box suitable for 8 Nos of KLCRs | Numbers 1.00 | — | 28,143 | 28,143 |
| 75 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers 2.00 | — | 15,009.6 | 30,019.2 |
| 76 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h ic k n e s s 3mm wherever required. T h e termination and cable core particulars shall be painted on the PVC/ nylon sleeves. T h e work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit 850.00 | — | 167.99 | 1,42,791.5 |
| 77 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h ic k n e s s 3mm wherever required. T h e termination and cable core particulars shall be painted on the PVC/ nylon sleeves. T h e work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination u s i n g PBT fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit 120.00 | — | 201.27 | 24,152.4 |
| 78 | Concreting a n d erection o f Re l a y racks- 168/56 relay capacity using 'J' type bolts and painting of relay rack as per the instructions of Railway representative at site.(Supply of relay rack is not covered in this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, paint a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. a)Concreting and erection of relay rack - 168 capacity | Numbers 2.00 | — | 6,818.18 | 13,636.36 |
| 79 | Fixing of plug boards, 50 way terminal blocks with 2BA terminals, a n d wiring of relays as per the approved circuit diagram using wire P V C 1 6 / 0 . 2 m m c o p p e r . Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide s m o o t h materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring o f contacts f o r data logger and terminating them in tag blocks, provision of relay index board.(Supply o f relays, plug boards, connectors and retaining clips i s not c o v e r e d i n this schedule). [Wire PVC 16/0.2mm copper, tag blocks, 2BA terminals, h a r d w o o d p l a n k o f size 600mmx 900mmx25mm w i t h decolum finish, MS a n g l e s o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, p h y n o l i c sheet 6mm t h i c k o f size 1200mmX1800mm with aluminium grooved channel frame for relay index board, paints, soldering materials, bunching thread, wire w o u n d resistance, condenser, wire supporting tra y w ith cover of suitable size made of PVC, paint, varnish and a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay 200.00 | — | 1,045.76 | 2,09,152 |
| 80 | Fixing o f additional p l u g boards, 5 0 ways terminal b l o c k s a n d w i r i n g o f additional relays a s p e r t h e approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC s h a l l b e p r o v i d e d w h e r e v e r required. Alterations t o Re l a y particulars s h a l l be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g b o a r d s , connectors and retaining clips and 50 way terminal boards is n o t covere d i n t h i s schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 2 5 m m thick for fixing resistors and condensers, soldering materials, bunching thread, w i r e wound resistance, condenser, wire supporting tray with cover o f suitable size made of PVC, paint, varnish and all other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay 300.00 | — | 726.5 | 2,17,950 |
| 81 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 1 6 / 0 . 2 m m c o p p e r . T h e w o r k includes p a i n t i n g a l t e r a t i o n s a n d r e l e a s i n g the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm c o p p e r , soldering materials, bunching t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay 475.00 | — | 695.67 | 3,30,443.25 |
| 82 | Supply o f Double walled corrugated pipe - 103.5mm i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2 ) : 2001 with o n e coupler for every 6 m of pipe as per Technical specification | Metre 150.00 | — | 365.19 | 54,778.5 |
| 83 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre 120.00 | — | 1,119.16 | 1,34,299.2 |
| 84 | Supply a n d l a y i n g o f P V C Warning Tape colour Orange, w i d t h o f 2 5 0 m m ( 1 0 " ) by p r i n t i n g w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre 2000.00 | — | 46.15 | 92,300 |
| 85 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. | Numbers 190.00 | — | 1,622.5 | 3,08,275 |
| 86 | Supply of Track Feed Resistance | Numbers 31.00 | — | 287.77 | 8,920.87 |
| 87 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers 4000.00 | — | 61.44 | 2,45,760 |
| 88 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers 250.00 | — | 93.02 | 23,255 |
| 89 | Supply of PBT terminals 25mm/ 60mm centre a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers 200.00 | — | 103.84 | 20,768 |
| 90 | Supply of E-Type Locks | Numbers 5.00 | — | 1,234.88 | 6,174.4 |
| 91 | Supply and wiring of LEDs with resistance and fixing on the cable termination rack for indicating "FUSE BLOWN OUT" for each circuit. The LEDs and resistances shall be fixed on a phynolic sheet 50mm width and 3mm thick. The phynolic sheet shall be fixed by the side of the corresponding Fuse Blocks. Separate switch shall be provided for each circuit.[LEDs 10mm, holders, resistance, switch, phynolic sheet, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 10.00 | — | 60.68 | 606.8 |
| 92 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit 50.00 | — | 37.74 | 1,887 |
| 93 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm d i a a n d 300mm long a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe f o r cable entry a n d o n e G I pipe 150mm long 32mm dia for drawl of jumper w i r e s f o r P o i n t machines e t c . , fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside w ith o n e coa t of red-oxide and two coats of aluminium paints. | Numbers 37.00 | — | 5,029.69 | 1,86,098.53 |
| 94 | Installation of combined type point machine- I R S t y p e a n d c o n n e c t i n g a l l ground connections including wiring and termination i n p o i n t m a c h i n e a n d interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision o f insulation to stretcher bars, t h r o w b a r l u g a n d "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat w i r e P V C 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 37.00 | — | 16,383.88 | 6,06,203.56 |
| 95 | Installation of Signal post telephone (paging and talk back) | Numbers 1.00 | — | 5,392.75 | 5,392.75 |
| 96 | Filling e a r t h a r o u n d location boxes/signal foundations for a width of 0.5m on all sides, u p t o a level 150mm below t h e foundation top. This work includes consolidation of earth by watering and ramming.The earth shall be taken from Railway premises as instructed by Railway representative at site. | cum 5.00 | — | 231.3 | 1,156.5 |
| 97 | Excavation of pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 25.00 | — | 9,213.28 | 2,30,332 |
| 98 | "Erection o f s u r f a c e b a s e , s i g n a l pole, mounting o f c o l o u r l i g h t s i g n a l u p t o 4 aspects complete o n S i g n a l p o l e / Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole l a m p holder, filament switching units, C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board w h e r e v e r necessary, termination o f tail cables, wiring o f signal unit w ith P V C wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through b o l t s h a l l be provided by drilling a hole i n the signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, M sand, Signal C o l l a r R i n g s , w i r e PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , p a i n t s PVC/Nylon sleeves, enameled number plates. enameled marker boards, E W S locks, a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers 25.00 | — | 8,287.08 | 2,07,177 |
| 99 | "Excavation o f p i t a n d c a s t i n g concrete foundation as per Drg, No.SG/CN/02/10 using metallic templates, f o r erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly of size 20/25mm a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers 15.00 | — | 4,645.17 | 69,677.55 |
| 100 | " E r e c t io n o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, L E D aspects/ l e n s e s , b u l b s w i t h holders (whichever i s applicable), fi x i n g o f lens guards, number p l a t e , termination o f tail cables, wiring o f signal unit w ith P V C wire 3/0.75mm copper, provision o f E W S locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint.(Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this schedule).[Wire PVC 3/0.75mm copper, lens guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials s h a l l be supplied by the Contractor]." | Numbers 15.00 | — | 3,170.44 | 47,556.6 |
| 101 | Fixing o f Offset brackets using 'U' bolts and nuts, erection o f P o s t t y p e s h u n t Signals, termination o f tail cables a n d wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting o f o n e coat o f red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n the CLS post and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers 19.00 | — | 2,306.03 | 43,814.57 |
| 102 | Fixing o f junction type route indicators - 1 way to 6 ways - complete/ fixing of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply o f junction type Route Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS l o c k s , w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing a n d w i r i n g of direction type route indicator - 3 way | Numbers 2.00 | — | 2,679.26 | 5,358.52 |
| 103 | Fixing o f junction type route indicators - 1 way to 6 ways - complete/ fixing of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply o f junction type Route Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS l o c k s , w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. d)Fixing a n d w i r i n g of direction type route indicator - 4 way | Numbers 1.00 | — | 4,363.69 | 4,363.69 |
| 104 | Fixing o f junction type route indicators - 1 way to 6 ways - complete/ fixing of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply o f junction type Route Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS l o c k s , w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. e)Fixing a n d w i r i n g of direction type route indicator - 5 way | Numbers 1.00 | — | 4,582.91 | 4,582.91 |
| 105 | Excavation of pit and construction of masonry platform a s p e r drawing No. SG/CN/02/12 w i t h c o u n t r y b r i c k s o f size 220mmx 100mmx60mm (app) a t t h e foot of signal post telephones a s p e r the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand and all other miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Numbers 1.00 | — | 5,355.94 | 5,355.94 |
| 106 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers 17.00 | — | 8,914.5 | 1,51,546.5 |
| 107 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers 9.00 | — | 7,145.44 | 64,308.96 |
| 108 | Alteration to existing DC Track Circuits to suit R E / N o n R E s t a n d a r d a s p e r approved signaling plan. This work includes provision o f d o u b l e bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lea d connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers 30.00 | — | 4,234.65 | 1,27,039.5 |
| 109 | Alteration to existing DC Track Circuits to suit R E / N o n R E s t a n d a r d a s p e r approved signaling plan. This work includes provision o f d o u b l e bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lea d connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers 30.00 | — | 3,850.31 | 1,15,509.3 |
| 110 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation a n d erection o f apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, ' E ' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for thework shall be supplied by the Contractor.] | Numbers 37.00 | — | 11,333.1 | 4,19,324.7 |
| 111 | " E x c a v a t i o n o f pit, casting concrete foundation a n d erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' t y p e l o c k f o r t h e f r o n t d o o r and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]""" | Numbers 33.00 | — | 8,787.04 | 2,89,972.32 |
| 112 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be r e p a i n t e d / c o r r e c t e d o n t h e d o o r s of a p p a r a t u s c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. T h i s w o r k i n c l u d e s c l o s i n g t h e opening create d f o r e n t r y o f n e w c a b l e s i n the apparatus cases w i t h masonry b r i c k work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination r a c k s w i t h cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit 1250.00 | — | 73.59 | 91,987.5 |
| 113 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse b l o c k s o n t h e terminal b o a r d , drilling of n e c e s s a r y h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner s i d e o f t h e doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." a)Termination o n 25/60mm P B T terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit 7750.00 | — | 172.14 | 13,34,085 |
| 114 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse b l o c k s o n t h e terminal b o a r d , drilling of n e c e s s a r y h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner s i d e o f t h e doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." b)Termination o n P B T f u s e b l o c k (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit 400.00 | — | 209.93 | 83,972 |
| 115 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse block s, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and a l s o o n t h e i n n e r s i d e o f t h e d o o r s of apparatus cases. After terminations are over, t h e s i d e o p e n i n g s o f a p p a r a t u s case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location) (Per Unit = Per Terminal block) | Per Unit 900.00 | — | 151.09 | 1,35,981 |
| 116 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse block s, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and a l s o o n t h e i n n e r s i d e o f t h e d o o r s of apparatus cases. After terminations are over, t h e s i d e o p e n i n g s o f a p p a r a t u s case foundation shall b e closed w ith brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound. b)Termination o f cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit 110.00 | — | 188.86 | 20,774.6 |
| 117 | Installation of charged secondary cells of the following capacities i n a p p a r a t u s cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V-40/80AH cells in apparatus cases(Per Unit = Per Cell) | Per Unit 93.00 | — | 491.59 | 45,717.87 |
| 118 | Carrying out alterations to the existing SM's control panel. T h e w ork includes drilling of holes o n t h e To p plate wherever required, fixing and wiring of knobs, buttons, counters, LEDs with holder, closing of unwanted holes, carrying o u t painting alterations o n the panel, termination of additional cables and carrying out alteration to the existing wiring as per approved circuit diagram, releasing of unused wires, and painting of particulars as per the instructions of Railway representative at site.(Supply o f knobs, buttons and counters is not included in the scope of this schedule). [LED l a m p s with holder, p a i n t , soldering materials a n d all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor]. | Lumpsum 5.00 | — | 15,967.35 | 79,836.75 |
| 119 | Provision of signaling arrangement during Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site. (Supply of relay rack, relays, and SM slide instrument is not included in this schedule). [All other miscellaneous materials required for the work shall be supplied by the Contractor]. | Station 1.00 | — | 33,631.06 | 33,631.06 |
| 120 | P r o v i s i o n o f P A s y s t e m a n d Magneto telephone communication a t stations/ tents a s p e r t h e i n s t r u c t i o n s o f Railway representative a t site. T h e P A system and magneto telephones will be returned to the contractor after the completion of NI working. Signalling cables available m a y be used for the communication.(Hiring o f P A system equipments and magneto telephones shall be d o n e b y the Contractor)[All other miscellaneous materials required for the w ork shall b e supplied b y the Contractor]. (Per Unit= Per set per day) | Per Unit 3.00 | — | 1,637.25 | 4,911.75 |
| 121 | Hiring o f tarpaulin tents a n d providing the s a m e a t places a s instructed b y Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, tube lights and pedestal f a n . Drinking w a t e r i n cans.The tents shall be fixed firmly t o withstand rain, strong wind etc.(Per Unit = Per tent per day) | Per Unit 3.00 | — | 1,328.3 | 3,984.9 |
| 122 | Excavation of pit, concreting 'A' type foundation and fixing ground lever frames single/double as per Drg.No.SG/CN/02/11 complete with ground connection. The work includes concreting of 'A' type foundations and fixing of HP lock and connecting the ground lever frame with the HP lock using MS rod as instructed by Railway representative at site. (Refer Chapter-20, 17.1)(Supply of ground lever frames, hand plunger locks and 'A' type foundations is not covered in this schedule).[Cement, M sand, stone jelly of size 20/25mm, fixing bolts and nuts with washers and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 1.00 | — | 8,351.55 | 8,351.55 |
| 123 | Fixing o f E KT instrument w i t h ( o r ) without c r a n k h a n d l e o r o n suitable fi x t u r e s at s t a t i o n / a p p a r a t u s c a s e , p r o v i s i o n of economiser push switch with locking facility, w i r i n g w i t h w i r e P V C 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting.(Supply of electric key transmitter and crank handles i s n o t covered i n this schedule). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, b o l t s a n d n u t s , p a i n t s , push switches, padlocks a n d other miscellaneous materials required f o r t h i s w o r k s h a l l be supplied by the contractor]. | Numbers 10.00 | — | 5,445.94 | 54,459.4 |
| 124 | Casting concrete foundation and erection and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 2.00 | — | 3,972.14 | 7,944.28 |
| 125 | Provision of E type lock with key for fixing the same in LC/HP/FP Locks/SM slides | Numbers 5.00 | — | 697.45 | 3,487.25 |
| 126 | Laying o f DWC/Split D W C P i p e s f o r Track Crossing/Road Cutting/Trenches | Metre 7000.00 | — | 42.46 | 2,97,220 |
| 127 | Releasing o f existing Ro u t e Indicators of different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers 2.00 | — | 1,541.51 | 3,083.02 |
| 128 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along w i t h r a i l s , accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. Also the resultant pits s h a l l b e re-surfaced a n d consolidating by ramming and levelling" | Numbers 5.00 | — | 1,580.36 | 7,901.8 |
| 129 | Releasing of existing point lay-out with facing point lock,split stretchers, electrical detector, lock bars, point/trap indicators cranks, rods e t c . , carefully without D a m a g i n g the materials, accounting a n d stacking them neatly a t a place as instructed by Railway representative at site. | Set 9.00 | — | 2,852.7 | 25,674.3 |
| 130 | Releasing o f existing apparatus cases (Full/ H a l f / Quarter s i z e ) without d a m a g e after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall b e accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers 45.00 | — | 3,006.71 | 1,35,301.95 |
| 131 | Breaking o f concrete a n d releasing the e x i s t i n g c a b l e termination b o x e s , after releasing t h e b a s e plank, Terminal blocks, F u s e B l o c k s , Terminal B o a r d s , c u t rails, pipes, e t c . , closing t h e resultant p i t s and consolidating i t b y ramming a n d levelling. T h e released materials shall b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers 29.00 | — | 2,004.94 | 58,143.26 |
| 132 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with o r w i t h o u t R o u t e Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work i n c l u d e s b r e a k i n g t h e concrete foundation,closing t h e r e s u lt a n t p i t and resurfacing it by ramming and levelling. | Numbers 20.00 | — | 3,083.03 | 61,660.6 |
| 133 | Dismantling a n d releasing o f existing Point m a c h i n e s ( a l l t y p e s ) i n c l u d i n g ground connections and other accessories available c o m p l e t e w i t h o u t a n y d a m a g e t o the g a d g e t s , accounting a n d s t a c k i n g them neatly a t a place a s instructed b y Railway representative at site. | Numbers 29.00 | — | 2,698.69 | 78,262.01 |
| 134 | Dismantling and releasing of ground lever frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling. | Set 1.00 | — | 5,550 | 5,550 |
| 135 | "Releasing o f existing g r o u n d t y p e shunt signals along with surface base, signal post e t c c a r e f u l l y w i t h o u t a n y damage, accounting a n d stacking the m neatly a t a place as instructed by Railway representative at site. The work also includes breaking and removal o f concrete foundation and refilling o f t h e r e s u lt a n t pit by ramming and levelling." | Numbers 9.00 | — | 2,196.41 | 19,767.69 |
| 136 | Releasing of existing TLD boxes with stumps a n d terminals after releasing a l l t h e bond w i r e s . T h e r e l e a s e d m a t e r ia ls s h a l l be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers 110.00 | — | 159.29 | 17,521.9 |
| 137 | Provision of one skilled and 2 unskilled staff r o u n d t h e c l o c k t o a t t e n d t h e teething trouble of the installation along with SSE/JE after t h e installation h a s been brought into commissioning. T h e w o r k includes routine maintenance, failure restoration a s p e r the direction of the SSE/JE | Month 1.00 | — | 73,903.01 | 73,903.01 |
| 138 | Providing the services of Computer oriented technical manpower t o carryout works like Drawing, computation, writeup e t c . , using computer, using software like AUTOCAD, MS Office etc., f o r 08.00 h r s i n a d a y w ith all expenses of transportation, accommodation, f o o d , consumables e t c . , w i t h a l l ascents, descents, taxes, octroi, cess, f e e s , duties, d u t i e s w i t h contractors c o s t e t c . , a s per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: T h e p e r s o n e n g a g e d f o r p r o v id in g the services shall b e convergent with computer working knowledge in above software. | Man- 10.00 Days | — | 913.28 | 9,132.8 |
| 139 | Protection adjustments a n d re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S & T portion o f t h e works. The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- 180.00 Days | — | 847.59 | 1,52,566.2 |
| 140 | Protection, adjustment a n d reinstating of S & T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S & T portion of works. T h e w o r k c a n i n v o l v e fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination o f cables, m i n o r patch work on damages at location box, Plastering, Concreting b r i c k w o r k , w i r i n g alterations, c a b l e jointing e t c a s p e r instruction of Railway representatives at size. | Man- 90.00 Days | — | 1,073.45 | 96,610.5 |
| 141 | Transportation of Signalling materials by road a s p e r t h e i n s t r u c t i o n s o f Railway representative at site. The work also includes l o a d i n g a n d unloading o f the materials a)Transportation of Signalling materials upto 100kms | MT-Km 4000.00 | — | 22.75 | 91,000 |
| 142 | Transportation o f Signalling materials more than 100km | MT-Km 6500.00 | — | 13.91 | 90,415 |
| 143 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling t h e formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as per the instruction of Railway representative at site. | Hour 15.00 | — | 1,202.5 | 18,037.5 |
| Schedule total | ₹1,45,35,263.99 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
I_CT_GCC-
ATTACHMENT
GCCCorrectionSlip1to11_comp.pdf Correction Slip 1 to 11
ATTACHMENT
ModelformofBankGuarantee_1.pdf Bank Guarantee Model
ATTACHMENT
PoliceVerification_1.pdf
ATTACHMENT
JPODETAILS_compressed1.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
TenderDocumentOT2_2.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
GCCCorrectionSlip1to11_comp.pdf
ATTACHMENT
ModelformofBankGuarantee_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .