Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC KOTHAR MAJALI SADASHIVGAD KARWAR UTTARA KANNADA 581360 | KARWAR | UTTARA KANNADA | KARNATAKA | 581360 | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.6 L+₹27,000 (1.26%)Rejected-Finance | L2 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 3 | L3₹23.5 L+₹2.1 L (9.86%)Rejected-Finance | L3 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 4 | L4₹23.5 L+₹2.2 L (10.2%)Rejected-Finance H NO 374 1 BUILDING I AQUEM PLAZA TF F4 OPP DEVKI STEEL AQUEM BAXIO MARGAO GOA 403707 | MARGAO | SOUTH GOA | GOA | 403707 | L4 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 5 | L5₹23.7 L+₹2.3 L (10.8%)Rejected-Finance | L5 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
12 Nov 2022, 6:00 pmClosed
GE(SB) Karwar
GE(SB) Karwar
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTINGS, FIXTURES INCLUDING EARTHING AND GARDEN LIGHTS AT BAITHKOL, KAMATH BAY, LITTLE BINAGA, NOM, NEW MAP QTRS AT NAVAL BASE KARWAR UNDER GE(SB) KARWAR.
2022_MES_549971_2
8933/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE(SB) Karwar
As per tender
8 documents required · 8 mandatory
₹500
GE(SB) Karwar
₹65,000
Yes
22 Nov 2022
3 Nov 2022
14 Nov 2022
3 Nov 2022
12 Nov 2022
7 Nov 2022
3 Nov 2022 - 5 Nov 2022
Amount
Rectifying the defects in domestic fluroscent tube/CFL light fittings any type and at any height, ceiling rose, electric bell by tightening loose connections and rectifying defects, testing complete all as specified and directed.
Opening switch mounting plate at normal height upto 1.5 meter, rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed. Note for Item No 1 & 2 :- The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S&F in repairs" under relevant items of this schedule hereinafter and in such cases the above items will not be measured and paid for.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & caping medium grade with all accessories in wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
One light/fan point controlled by one switch
One 3 pin socket outlet 5 Amp on same board with other switches.
One 3 pin socket outlet 5 Amp on independent board.
One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
M&L for point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge.
All as per item No.5 above but with cables 4 Sqmm for one 3 pin socket outlet 15 Amps on independent board
M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge.
One light/fan point controlled by one switch
One 3 pin socket outlet 5 Amp on same board with other switches.
One 3 pin socket outlet 5 Amp on independent board.
One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
All as per item No.7 above but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board
All as per item No. 7 above but with cables 4 Sqmm for one 3 pin socket outlet 15 Amps on independent board
Taking down submain wiring cable of any size/type alongwith earth wire with or without concealed/surface conduit/casing caping complete all as specified and directed.
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
All as per item No 11 above but 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through existing conduit and junction box fixed in wall/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note:- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
All as per item No 13 above but 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire
S&F in repairs MCB DB SPN, 12 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs MCB DB TPN, 4 way, 415 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs MCB TPN, 6 to 32 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs MCB TPN, 40 to 100 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs MCB SPN, 6 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs MCB SP, 5 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket industrial type with one MCB 20 Amp double pole 240 Volts complete all as specified and directed.
S&F in repairs switch piano 5 Amps one way flush type complete all as specified and directed. Make : Havells/Anchor/ Cona or equivalent.
S&F in repairs switch piano 5 Amps two way flush type, complete all as specified and directed. Make : Havells/Anchor/ Cona or equivalent.
S&F in repairs socket outlet 2 in 1, 5 pin, 5 Amps flush type, complete all as specified and directed. Make : Havells/ Anchor/ Cona or equivalent.
S&F in repairs switch socket combination 5 Amps, 2 in one, 3 pin, flush type multi purpose complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs switch piano 15 Amps one way flush type complete all as specified and directed. Make : Havells/Anchor/ Cona or equivalent.
S&F in repairs socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amp, flush type universal complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs ceiling fan regulator electronic five step type 230 Volts single phase complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs bell push 5 Amps 230 volts AC, single pole complete all as specified and directed. Make : Havells/ Anchor/ Cona or equivalent.
S&F in repairs bell electric (ding dong bell) 230 volts AC, single phase complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs lamp holder, PVC/polycarbonate type with back plate complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repair ceiling rose surface bakelite 65 x 50 mm three terminal on and including PVC junction box of suitable size complete all as specified and directed. Make : Havells/Anchor/Cona or equivalent.
S&F in repairs decorative modular switch 6 Amps single pole one way flush type complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/Legrand/Crabtree/Philips or equivalent.
S&F in repairs decorative modular switch 6 Amps single pole two way flush type complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/Legrand/Crabtree/Philips or equivalent.
S&F in repairs decorative modular socket 6 Amps, 3 pin, flush type, multipurpose complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/Legrand/Crabtree/Philips or equivalent.
S&F in repairs decorative modular switch 16 Amps single pole one way flush type complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/Legrand/Crabtree/Philips or equivalent.
S&F in repairs decorative modular twin socket 16 Amps, 3 pin, flush type, multipurpose type complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/Legrand/Crabtree/Philips or equivalent.
S&F in repair decorative modular ceiling fan regulator electronic five step type 230 Volts single phase complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/Legrand/Crabtree/Philips or equivalent.
S&F in repairs bell push 5 Amps modular type complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/ Legrand/Crabtree/Philips or equivalent.
S&F in repairs of following sizes front plate with base frame for fixing decorative modular switches/ sockets/ regulators etc and matching with existing complete all as specified and directed :- Make : Anchor (Roma) or equivalent in Legrand/Crabtree/Havells/Philips
2 module
3 module
4 module
6 module
8 module
S&F in repairs 5 watt LED box type light fittings 1 feet including making necessary connection complete all as specified and directed. Make : Havells/Philips/C&S/Bajaj/Shakti or equivalent.
S&F in repair LED down light 18 W of size 175 mm x 175 mm, square surface mounted, opaque diffuser including all accessories, complete all as specified and directed. Make : Havells/Bajaj/Shakti/ Wipro/C&S or equivalent
S&F in repair LED panel 36 W, square surface mounted of size 2'x2' LED luminare with polymer diffuser including all accessories, complete all as specified and directed. Make : Havells/Bajaj/Shakti/ Wipro/C&S or equivalent
S&F in repair decorative wall light fixture made up of polycarbonate, suitable for 1x10 W LED lamp (B-22 base) with back plate complete all as specified and directed by Engr-in-Charge. Make- Havells, Cat Part No - LHFOFWE1TZ1W012 or equivalent in Bajaj/CG/Wipro/C&S.
Supply and fixing in repair LED batten suitable for T8 LED retrofit tube 4' with LED tube rod 18 W, 230 Volts, completed with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Bajaj/Philips/ Wipro/ C&S/ Shakti or equivalent.
S&F in repair T8 LED tube rod 18/20 W, 4 feet length, 6000K complete with all as specified and as directed. Make : Havells/Bajaj/Philips/Wipro/Shakti/C&S or equivalent.
S&F in repair 10 watt LED box type light fittings 2 feet including making necessary connection complete all as specified and directed. Make : Havells/Philips/C&S/Bajaj/Shakti or equivalent.
Taking down ceiling fan of any sweep, dismantling, removing the existing painting and cleaning the surface and painting with white metalic colour including marking MES No on fan with black colour etc and fixing up in the original location connecting up and testing complete all as directed.
Taking down geysers of 25 Ltr capacity removing the existing painting and cleaning the surface and Spray painting with white metalic colour including marking MES No on fan with black colour etc and fixing up in the original location connecting up and testing complete all as directed.
Supply and fix 25 ltrs capacity vertical geyser including safety valve, inlet & outlet pipes with 5 BEE star rating complete all as specified & directed. Make Recold or equivalent. Note : Old unserviceable will be deposited in MES store by the contractor.
S&F in repairs decorative modular 32 Amps DP switch 2 module one way flush type complete all as specified and directed. Make : Havells/Anchor (Roma)/Cona/Legrand/Crabtree/Philips/Indo Asian or equivalent.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. Note : (a) The unit rate quoted shall deemed to be included for minor items viz nuts, bolts split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and sperately under ser item Nos 55 & 56 here-in-after. (c) Rewinding of fan will be measured and paid for separately under under ser item Nos 57 to 59 here-in-after.
S&F in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed.
S&F in repairs bearing No 6201/6202/6203 suitable for ceiling fan/exhaust fan complete all as specified and directed. Make : SKF/NBC/TATA/FAG or equivalent.
M&L for removing of burnt out copper winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
Description all as per item No 57 above but exhaust fan of 300 mm sweep.
Description all as per item No 57 above but exhaust fan of 450 mm sweep.
S&F in repairs heavy duty vacuum pressure impregnated copper Ballast (VPIT) for CFL lamp 9/10/11/13/18 watt 240 volt, low loss electro magnetic ballast all as directed. Make: - Bajaj/Havells/CG/ Wipro or equivalent.
S&F in repairs CFL lamp holder suitable for CFL light fitting 9/10/11/13/18 W all as specified and directed.
S&F in repair CFL lamp 9/10/11/13/18 watt 230 Volt cross pin type complete all as specified and directed.
S&F in repair CFL lamp 2 pin type 9/11/15 W 230 Volts ISI marked all as specified and as directed.
Fixing only energy meter 230/415 volt, 10-25 Amp including making incoming and outgoing electric connection and testing including taking down old defective energy meter and depositing the same to MES store yard complete all as specified and directed. Note :- Energy meter will be issued under Sch ‘B’ free for hanging/fixing only.
S&F in repair ventilator fan AC single phase 230 V of size 200 mm (PVC body) with louvers shutter (white/Ivory) and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m complete all as specified and directed. Make- Orient/Bajaj/Usha/CG/Havells or equivalent.
S&F in repair exhaust fan AC single phase 230 V of size 300 mm, 1400 RPM (steel body) with louvers shutter grey colour and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m complete all as specified and directed. Make- Orient/Bajaj/Usha/CG/Havells or equivalent. Note : Old unserviceable exhaust fan will be deposited in MES store by the contractor.
S&F in repair exhaust fan AC single phase 230 V of size 450 mm, 1400 RPM (steel body) with louvers shutter grey colour and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m complete all as specified and directed. Make- Orient/Bajaj/Usha/CG/Havells or equivalent. Note : Old unserviceable will be deposited in MES store by the contractor.
S&F in repair ceiling fan AC single phase 230 V of size 1200 mm sweep with blade white/brown and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make- Orient/Bajaj/Usha/CG/Havells or equivalent. Note : Old unserviceable ceiling fan will be deposited in MES store by the contractor.
S&F in repair wall mounted fan AC single phase 230 V of size 400 mm sweep with blade white and connected with flexible copper cord of suitable size of length not less than 0.7m complete all as specified and directed. Make- Orient/Bajaj/ Usha /CG/Havells or equivalent. Note : Old unserviceable wall mounted fan will be deposited in MES store by the contractor.
S&F in repairs heating element 1.5 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed. Make : CG/ Bajaj/ Recold/ Havells
S&F in repairs heating element 2.0 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed. Make : CG/ Bajaj/ Recold/ Havells
S&F in repairs thermostat adjustable between 30 degree C to 85 degree C for geyser complete all as specified and directed.
S&F in repairs PVC connection 15 mm dia 450 mm long (heavy duty) with 2 Nos PTMT nut and washer for cold water complete all as specified and directed.
S&F in repairs brass chrominum plated connection 15 mm dia 450 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer for hot water complete all as specified and directed.
S&F in repairs PVC connection 15 mm dia 600 mm long (heavy duty) with 2 Nos PTMT nut and washer for cold water complete all as specified and directed.
S&F in repairs brass chrominum plated connection 15 mm dia 600 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer for hot water complete all as specified and directed.
S&F in repairs PVC insulated and sheathed copper multistranded cable three core 2.5 sqmm, heavy duty and connected from plug top to geyser as per site requirement complete all as specified and directed
M&L for earthing complete with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts washers and check nuts of steel/GI duly protected with 15mm bore light grade pipe upto main board, 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, char coal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for PCC cover, funnel with wire mesh complete and all as specified. Note :- The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15mm bore, RCC cover slabs 50mm thick with 8mm dia CTD bars @ 140mm c/c both ways etc complete.
S&F in repair LED 70W edge series bldg security light fitting pressure die -cast housing with toughned glass and including LEDs with secondary optics and IP 66 protection complete all as specified and directed. Make : Bajaj cat part No. ENXT P 84L WH CR PC SD or equivalent in Philips/C&S/ Havells/Shakti
S&F in repair LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP 65 complete all as specified and directed. Make- Bajaj/ CG/Havells/Wipro/Halonix/C&S or equivalent.
S&F in repairs LED bollard 10W circular cast aluminium bollard with opaque diffuser 900 mm long complete all as specified and directed. Make : Bajaj/Shakti/Havells/Philips/C&S or equivalent.
S&F in repair decorative gate or garden light including 1x20 W LED lamp made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22base IP65 complete all as specified and directed. Make : Havells/Bajaj/CG/Philips/Shakti or equivalent.
S&F in repair LED panel 24 W, square surface mounted of size 1'x1' LED luminare with polymer diffuser including all accessories, complete all as specified and directed. Make : Havells/Bajaj/Shakti/ Wipro/C&S or equivalent
Taking down old defective/unserviceable tube light/down lighter/mirror light/gate light/bulk head/garden light/building street light of any size or type and fixing only LED light fittings of any type or size including making necessary connection complete all as specified and directed. (Note :LED Light fittings will be issued under Sch ‘B’ free for fixing only).
Taking down old defective/unserviceable MCB SPN/TPN of any size or type and fixing only MCB of any type or size including making necessary connection complete all as specified and directed. (Note:MCBs will be issued under Sch ‘B’ free for fixing only).
Supply and fixing in repair iSS LED Linear batten size 4' (Polymer) with smart sensor (auto dimmable) , 20 watt, 230 Volts, completed with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Shakti/Havells/Bajaj/Philips/ Wipro/ C&S/ or equivalent.
BROTECH
Raheel Enterprises
N P ENGINEERINGS
SRI GURUPRASAD INFRATECH
OM SAI ELECTRICALS AND HARDWARES
M/S. B G GAONKAR
HARSHITA MARINE SERVICES
M/S VERNEKAR AGENCIES
SIRI SALES AND SERVICES
K.G.SHANKER
SHRI MALLIKARJUN BATTERY AND ELECTRICAL WORKS
JAI SHREE GOPAL ELECTRICALS
H S krishna Electricals
Bidder Name
K.G.SHANKER
Raheel Enterprises
JAI SHREE GOPAL ELECTRICALS
SHRI MALLIKARJUN BATTERY AND ELECTRICAL WORKS
M/S VERNEKAR AGENCIES
SIRI SALES AND SERVICES
PEGASOS ENGINEER TRADERS
M/S. B G GAONKAR
OM SAI ELECTRICALS AND HARDWARES
BROTECH
H S krishna Electricals
HARSHITA MARINE SERVICES
SRI GURUPRASAD INFRATECH
N P ENGINEERINGS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .