Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-Finance NANGOLE TAL KAVATHE MAHANKAL DIST SANGLI | KAVATHE MAHANKAL | SANGLI | MAHARASHTRA | ₹23.9 L | L1 | Accepted-Finance VALID |
| 2 | L2₹24.4 LAccepted-Finance SANGLI TAL MIRAJ DIST SANGLI | SANGLI | MIRAJ | MAHARASHTRA | ₹24.4 L | L2 | Accepted-Finance VALID |
| 3 | L3₹24.9 LAccepted-Finance | ₹24.9 L | L3 | Accepted-Finance VALID |
Updated dates
Tender Value
₹24.0 L
EMD Value
₹24,000
Closing Date
11 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER B and C Z P SANGLI
EXECUTIVE ENGINEER B and C Z P SANGLI
IMPROV TO ROAD DHULGAON PIMPALWADI MANEWADI AGALGAON O D R 174 CH.8.400 and CONSR OF C D WORK TAL K MAHANKAL
2026_SANGL_1281933_1
39/2025-2026
Open Tender
Civil Works
180 days
SANGLI
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹24,000
13 May 2026
26 Feb 2026
13 Mar 2026
26 Feb 2026
11 Mar 2026
26 Feb 2026
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 2 / 153 Specification No : Bd.A.1 Spec. Page No : 259
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 6 / 153 Specification No : Bd.A.2 Spec. Page No : 259
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete. Item / Page No : 38 / 157 Specification No : Bd.A.12 Spec. Page No : 264
Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foundations including necessary form work, compacting and curring, excetra complete. (with reversible drum type mixer without Supervisory Control and Data Acquisition with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 4 / 81 Specification No : CD.3 Spec. Page No : 160 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.)with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 10 / 176 Specification No : Bd.E.4, B-7 Spec. Page No : 289-290, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Supplying hard murum / kankar at the road site, including conveying and stacking, excetra complete. Item / Page No : 29a / 25 Specification No : MORTH-408 Spec. Page No : 139-142
Spreading hard murum / soft murrum / gravel or kankar for side width, excetra complete. Item / Page No : 30 / 25 Specification No : MORTH-408 Spec. Page No : 139-142
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering, excetra complete. Item / Page No : 31 / 25 Specification No : MORTH-408 Spec. Page No : 139-142
Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 8 / 176 Specification No : Bd.E.4, B-7 Spec. Page No : 289-290, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cement concrete pipe confirming to Indian Standard 458:2003 non pressure class-2 of 900 milimetre diameter in proper line, level and slope including providng and fixing collars in cement mortar 1:2 and curing, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 11 / 81 Specification No : CD.7 Spec. Page No : 162
Providing dry rubble stone pitching 23 centimetre (about 9 inch) thick including all material, quarry spalls, labour, excetra complete. Item / Page No : 34 / 25 Specification No : MORTH-2504 Spec. Page No : ---
Providing and fixing streamlined M-20 grade reinforced cement concrete guard stone including mild steel bar reinforcement, excetra complete. Item / Page No : 27 / 82 Specification No : CD.20 Spec. Page No : 169
Providing and laying weep holes of 100 milimetre diameter asbestos cement / polyvinyl chloride pipes as per drawing for abutment, returns, return walls, excetra complete. Item / Page No : 37 / 132 Specification No : MORTH 2705, 2706 Spec. Page No : --- Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.10 MB
Tendernotice_2.pdf
PDF • 1.54 MB
BOQ_2205020.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid