Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-Finance MAIN ROAD BONGAIGAON BONGAIGAON BONGAIGAON ASSAM 783380 UDYAM AS 04 0001458 | BONGAIGAON | ASSAM | 783380 | ₹22.0 L | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹23.7 LAccepted-Finance | ₹23.7 L | L2 | Accepted-Finance Not L1 Bidder |
| 3 | L3₹24.0 LAccepted-Finance | ₹24.0 L | L3 | Accepted-Finance Not L1 Bidder |
| 4 | L4₹25.4 LAccepted-Finance | ₹25.4 L | L4 | Accepted-Finance Not L1 Bidder |
Tender Value
₹32.6 L
EMD Value
₹65,300
Closing Date
12 Jan 2026, 3:00 pmClosed
AGM (EME)
FCI RO Jaipur
Annual Repairs and Maintenance Contract of Various Electrical / Mechanical Services at FSD Ajmer,FSD Kishangarh,FSD Nagaur, FSD Pali, FSD Bhilwara and FSD Marwar Junction under Divisional Office Ajmer, Rajasthan
2025_FCI_891854_1
ROJ/ELECT/8/2025-26
Open Tender
Electrical Works
365 days
FSDs under DO Ajmer
Please refer tender documents
3 documents required · 3 mandatory
₹0
₹65,300
28 Apr 2026
30 Dec 2025
13 Jan 2026
30 Dec 2025
12 Jan 2026
30 Dec 2025
FSD Ajmer
Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules b) Electric Motors & Pumps for Water supply arrangement(Electrical points only) c) Air coolers Water cooler (Electrical points only) d) Water cooler (Electrical points only) e) Air conditioners (Electrical points only) f) Feeder pillars/LT/HT panels, MV/LT OH line maintenance g) Transformer (only electrical works) h)Switching (on/off) operations of DG Set (One wireman and One Khallasi for all working days in a week)
FSD Kishangarh
Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules b) Electric Motors & Pumps for Water supply arrangement (Electrical points only) c) Air coolers Water cooler (Electrical points only) d) Water cooler (Electrical points only) e) Air conditioners (Electrical points only) f) Feeder pillars/LT/HT panels, MV/LT OH line maintenance g) Transformer (only electrical works) h)Switching (on/off) operations of DG Set (One wireman and One Khallasi for four days in a week)
FSD Nagaur
Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules b) Electric Motors & Pumps for Water supply arrangement(Electrical points only) c) Air coolers Water cooler (Electrical points only) d) Water cooler (Electrical points only) e) Air conditioners (Electrical points only) f) Feeder pillars/LT/HT panels, MV/LT OH line maintenance g) Transformer (only electrical works) h)Switching (on/off) operations of DG Set (One wireman and One Khallasi for four days in a week)
FSD Pali
Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules b) Electric Motors & Pumps for Water supply arrangement(Electrical points only) c) Air coolers Water cooler (Electrical points only) d) Water cooler (Electrical points only) e) Air conditioners (Electrical points only) f) Feeder pillars/LT/HT panels, MV/LT OH line maintenance g) Transformer (only electrical works) h)Switching (on/off) operations of DG Set (One wireman and One Khallasi for four days in a week)
FSD Bhilwara
Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules b) Electric Motors & Pumps for Water supply arrangement(Electrical points only) c) Air coolers Water cooler (Electrical points only) d) Water cooler (Electrical points only) e) Air conditioners (Electrical points only) f) Feeder pillars/LT/HT panels, MV/LT OH line maintenance g) Transformer (only electrical works) h)Switching (on/off) operations of DG Set (One wireman and One Khallasi for four days in a week)
FSD Marwar Junction
Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules. a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules b) Electric Motors & Pumps for Water supply arrangement(Electrical points only) c) Air coolers Water cooler (Electrical points only) d) Water cooler (Electrical points only) e) Air conditioners (Electrical points only) f) Feeder pillars/LT/HT panels, MV/LT OH line maintenance g) Transformer (only electrical works) h)Switching (on/off) operations of DG Set (One wireman and One Khallasi for two days in a week)
Material
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(for Voltage grade 1100V as per IS:694)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(for Voltage grade 1100V as per IS:694)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (for Voltage grade 1100V as per IS:694 and ISI Marked) Group 'C'
Supplying 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.(Conforms to IEC 60947 Or IS/IEC 60898 )(as and when required and directed by engineer in charge as per the site requirement)
Single pole (10A/20A)
Single pole and neutral(25A/32A)
Supplying and fixing following rating four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement)
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement)
Supplying following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way SPN double door
Supplying following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4+12) way, TPN
Supplying 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(conforms to IS 8623, IEC 61439)(as and when required and directed by engineer in charge as per the site requirement)
Supply of 1200 mm sweep, ISI Marked induction motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 5.0, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374:2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement)
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI ≥ 80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Supplying of Pressure Die Cast 70 watt LED well glass with high efficacy of greater than or equal to 100 lumens / watt fitting with control gear housing, SPD 5 KV/10KV,IP 66 Protection with secondary optics lenses and IK07/08 Protection with heat resistance glass eye bolt provided for mounting purpose & wire guard 70 Watt etc. as required of confirming to IS and IEC codes on the platform of godown truss/ truss of the clamps wiring with 3 x 1.5 Sq mm PVC insulated / WP flexible copper conductor wire, painting the clamps including connections and dismantling the existing fittings etc. as reqd.(as and when required and directed by engineer in charge as per the site requirement)
Supplying of Pressure Die Cast 40 watt LED well glass with high efficacy of greater than or equal to 100 lumens / watt fitting with control gear housing, SPD 5 KV/10KV,IP 66 Protection with secondary optics lenses and IK07/08 Protection with heat resistance glass eye bolt provided for mounting purpose & wire guard 40 Watt etc. as required of confirming to IS and IEC codes on the platform of godown truss/ truss of the clamps wiring with 3 x 1.5 Sq mm PVC insulated / WP flexible copper conductor wire, painting the clamps including connections and dismantling the existing fittings etc. as reqd.(as and when required and directed by engineer in charge as per the site requirement)
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
45 Watt Street Light LED Fixture
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
200 watt LED Flood Light
Supply of the following XLPE power cable with PVC insulated and PVC Sheathed Armoured aluminiun conductor cable confirming to IS -7098 1.1 KV grade at site of work .(Conforming TO BIS/IS Codes)
2 X 10 sqmm
4 X 16 sqmm
4 X 25 sqmm
Credit item
Dismantled scraped MS conduit pipe of different sizes, DB’s, GI wire and clamps
Dismantled scraped PVC conduit pipe of different sizes, and clamps
Dismantled Lights and Fittings of all types
Dismantled Old copper wire
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.94 MB
DNITAjmer.pdf
Tender Documents • 2.18 MB
BOQ_937424.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid